• Title/Summary/Keyword: MRI images

Search Result 1,011, Processing Time 0.037 seconds

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Preoperative Evaluation of Lower Rectal Cancer by Pelvic MR with and without Gel Filling (하부직장암 환자에서 초음파겔 삽입 전후의 골반 자기공명영상의 비교)

  • Kim, Dae Jung;Kim, Joo Hee;Lim, Joon Seok;Chung, Jae-Joon;Yu, Jeong-Sik;Kim, Myeong-Jin;Kim, Ki Whang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.323-331
    • /
    • 2014
  • Purpose : To assess the usefulness of rectal filling using ultrasonographic gel in patients with lower rectal cancer. Materials and Methods: Twenty five patients with lower rectal cancer were enrolled. High resolution pelvic MR was performed twice before and after gel filling. Independently and retrospectively, two radiologists reviewed each set of MR images using five-grade scales for sphincter involvement, CRM (circumferential resection margin) involvement and depiction of the tumor. Same two radiologists retrospectively performed consensus review of each set of MR images for tumor distance from the anal verge and T&N staging. Results: Tumor depiction scores from MR with gel filling were significantly higher than those of MR without distention (p<0.001). Compared to MR without distension, MR with gel filling had no significant differences in prediction of CRM or sphincter involvement (p>0.05). Distance from the anal verge was significantly different between MR with gel filling and rigid endoscopy ($6.8{\pm}1.6cm$ vs. $5.8{\pm}1.6cm$, p=0.001). There were no significant differences between pathological staging and MR staging with or without gel filling. Conclusion: MR with gel filling improved tumor depiction. And also MR with gel filling revealed same ability for the predictions of CRM or sphincter invasion in patients with lower rectal cancer, comparing with MR without gel filling.

Superior Labral Dimension of the Glenohumeral Joint on Direct MR Arthrography (MRA): Relationship with Presence of SLAP (Superior Labrum Anterior to Posterior) Lesion (직접 자기공명 견관절 조영술 상에서 상부 관절순의 크기: 상부 관절순 전후방 파열과의 관계)

  • Im, Tae Seong;Choi, Jung-Ah;Oh, Joo Han
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.193-199
    • /
    • 2014
  • Purpose : To evaluate the relationship between superior labral dimension of the glenohumeral joint on direct MRA and presence of SLAP lesion. Materials and Methods: IRB approval was obtained and informed consent was waived for this retrospective study. Direct MRA studies of the shoulder in 296 patients (300 shoulders) with arthroscopic surgery were analyzed by two radiologists blinded to the arthroscopic results, which were used as gold standard. One of the radiologists reviewed the images twice (session 1 and 2) for the evaluation of intra-observer variability. Transverse and longitudinal dimensions of superior labrum on coronal T1-weighted images were measured as base and height of the inverted triangular-shaped superior labrum and compared between patients with SLAP lesions vs. non-SLAP patients. Presence of meniscoid labrum was noted. Statistical analysis was done using unpaired t-test. Results: Among 279 patients (283 shoulders), 122 patients (43.1%) had SLAP lesions. The mean base/height of superior labrum in SLAP and non-SLAP patients measured on T1-weighted MR image were 8.8 mm / 5.2 mm, 8.5 mm / 4.9 mm for reader 1; 8.2 mm / 4.9 mm, 8.1 mm / 4.5 mm for session 1 of reader 2; 8.0 mm / 4.8 mm, 7.6 mm / 4.3 mm for session 2 of reader 2. In SLAP group, the mean labral height was larger than non-SLAP group with statistically significant difference (p<0.05). Fifteen patients (5.3%) had meniscoid labrum according to operation records. Conclusion: In patients with SLAP lesion, the height of the superior glenoid labrum on oblique coronal image of MRA was slightly larger than non-SLAP patients. A larger height of superior glenoid labrum may be associated with SLAP lesions.

A Study of Changes of Inversion Time Effect on Brain Volume of Normal Volunteers (반전 시간의 변화가 정상인의 뇌 체적에 미치는 영향에 대한 고찰)

  • Kim, Ju Ho;Kim, Seong-Hu;Shin, Hwa Seon;Kim, Ji-Eun;Na, Jae Boem;Park, Kisoo;Choi, Dae Seob
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.286-293
    • /
    • 2013
  • Purpose : The objective of this study was to analyze the brain volume according to the brain image of healthy adults in the 20s taken with different inversion time (TI). Materials and Methods: Brain images of healthy adults in the 20 s were acquired using magnetization prepared rapid acquisition gradient echo (MPRAGE) pulse sequence with 1.5 mm thickness of pieces and four inversion times (1100 ms, 1000 ms, 900 ms, 800 ms). The acquired brain images were analyzed to measure the volume of white matter (WM), gray matter (GM), intracranial volume (ICV). The statistical difference according to brain volume and gender was analyzed for each TI. Results: The brain volume calculated using Freesurfer was WM$486.52{\pm}48.64cm^3$ and GM=$646.83{\pm}57.12cm^3$ in mean when adjusted by mean ICV=$1278.94{\pm}154.92cm^3$. Men's brain volume(WM, GM, ICV) was larger than women's brain volume. In the intrarater reliability test, all of the intraclass correlation coefficients were high (0.992 for WM, 0.988 for GM, and 0.997 for ICV). In the repeated measures analysis of variance, GM and ICV did not show a significant difference at each TI (GM p=0.143, ICV p=0.052), but WM showed a significant (p=0.001). In the linear structure relation analysis, all of the Pearson correlation coefficients were high. Conclusion: WM, GM, and ICV indicated high reliability and solid linear structure relations, but WM showed significant differences at each TI. The brain volume of healthy adults in the 20s could be used in comparison with that of patients for reference purposes and to predict the structural change of brain. It would be needed to conduct additional studies to examine the contract, SNR, and lesion detection ability according to variable TI.

A Study of Radiation Incidence Angle in Cervical Vertebra Anteroposterior(AP) Examination by Position (자세에 따른 목뼈 정면 입사각에 대한 연구)

  • Kwak, Jonghyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.2
    • /
    • pp.101-107
    • /
    • 2015
  • In anteroposterior radiation test for cervical vertebra, it is general that the incidence angle of X-ray is $15^{\circ}$ to $20^{\circ}$ degrees to head regardless of position. So this study suggests appropriate incidence angle of cervical vertebra depended on the position. From 1 January 2013 to 31 December 2013, cervical spine radiographys and magnetic resonance imaging was performed in 107 people who visited P Hospital located in Pusan. Among them, 39 people(men 24, women 15) were below 80 above 20 years old(average age 54 years) with normal cervical lordosis(normal $40^{\circ}{\pm}5^{\circ}$). In erect position, the incidence angle of cervical vertebra is measured from lateral radiographic images. And in supine position, it measured from MRI sagittal images. Results based on gender, the incidence angle of cervical vertebra in erect position was $25.9^{\circ}$ for men, women was $23.1^{\circ}$, showed statistically significant (p<0.05). And the angle in supine was $11.6^{\circ}$ for men, women was $12.6^{\circ}$, showed not statistically significant (p>0.05) An analysis of age group shows, the incidence angle of cervical vertebra in erect position was $24.6^{\circ}$ under 50, and $25.0^{\circ}$ over 50. The angle in supine was $12.0^{\circ}$ under 50, and $11.9^{\circ}$ over 50. And all of them showed not statistically significant (p>0.05). At all ages, the average of incidence angles in erect position were $24.8^{\circ}$, and the angle in supine was $12.0^{\circ}$, showed statistically significant (p<0.05). The cervical vertebra incidence angle for X-ray was $15^{\circ}$ to $20^{\circ}$ degrees to head in general. But, through the results, it is recommended that the angle is $24.8^{\circ}$ in erect and $12.0^{\circ}$ in supine position. It could be shown true anteroposterior(AP) view of cervical vertebra and accurate intervertebral fusion fixing devices.

A Study of the Capsuloligamentous Anatomy of the Glenohumeral Joint Using Magnetic Resonance Imaging and Three-Dimensional Imaging. Dynamic In Vivo Study (자기공명 영상 및 3차원 영상을 이용한 견관절 관절낭-인대의 해부학적 연구. 역동학적 생체연구)

  • Park Tae-Soo;Choi Il-Yong;Joo Kyung-Bin;Kim Sun-Il;Kim Jun-Sic;Paik Doo-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.2
    • /
    • pp.154-158
    • /
    • 2000
  • Purpose : The purpose of this study is to demonstrate changes in the orientation ortho glenohumeral ligaments(GHL) in different degrees of abduction and rotation of the normal healthy individuals. Materials and Methods : Saline Magnetic Resonance(MR) arthrography of nine consecutive shoulders of normal healthy adults were checked. At that time, MR images were obtained in three different positions of abduction and external rotation($0^{\circ}C\;and\;0^{\circ},\;45^{\circ}C\;and\;25^{\circ}C,\;90^{\circ}$ and maximum, respectively). From a series of consecutive MRI, three-dimensional images were reconstructed after detecting the location of the middle glenohumeral ligament(MGHL) and the inferior glenohumeral ligament(IGHL) using workstation computer. Results : The shape of the MGHL was taken in double curved, and straight, and finally curved again in three different positions of the shoulder in sequence. On the other hand, the shape of the IGHL was obliquely positioned, and curvilinear, and finally straight and extended at lower part of the anterior surface of the humeral head. Conclusions : At $45^{\circ}$ of abduction and $25^{\circ}$ of external rotation, and at $90^{\circ}$ of abduction and maximal external rotation of the shoulder, the MGHL and the IGHL had the role of the most important static stabilizer of the glenohumeral joint repectively.

  • PDF

Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance (반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.581-588
    • /
    • 2019
  • MRI is superior when contrasted to help the organization generate artifacts resolution, but also affect the diagnosis and create a image that can not be read. Metal is inserted into the tooth, it is necessary to often be inhibited in imaging by causing the geometric distortion due to the majority and if the difference between the magnetic susceptibility of a ferromagnetic material or paramagnetic reducing them. The purpose of this study is to conduct a metal artefact in accordance with the analysis using a diamagnetic material. The magnetic material include a wire for the orthodontic bracket and a stainless steel was used as a diamagnetic material was used copper, zinc, bismuth. Testing equipment is sequenced using 1.5T, 3T was used was measured using a SE, TSE, GE, EPI. A self-produced phantom material was used for agarose gel (10%) to a uniform signal artifacts causing materials are stainless steel were tested by placing in the center of the phantom and cover inspection of the positive cube diamagnetic material of 10mm each length.After a measurement artefact artifact zone settings area was calculated using the Wand tool After setting the Low Threshold value of 10 in the image obtained by subtracting images, including magnetic material from a pure tool phantom images using Image J. Metal artifacts occur in stainless steel metal artifact reduction was greatest in the image with the bismuth diamagnetic materials of copper and zinc is slightly reduced, but the difference in degree will not greater. The reason for this is thought to be due to hayeotgi offset most of the susceptibility in bismuth diamagnetic susceptibility of most small ferromagnetic. Most came with less artifacts in image of bismuth in both 1.5T and 3T. Sequence-specific artifact reduction was most reduced artifacts from the TSE 1.5T 3T was reduced in the most artifacts from SE. Signal-to-noise ratio was the lowest SNR is low, appears in the implant, the 1.5T was the Implant + Bi Cu and Zn showed similar results to each other. Therefore, the results of artifacts variation of diamagnetic material, magnetic susceptibility (${\chi}$) is the most this shows the reduced aspect lower than the implant artificial metal artifacts criteria in the video using low bismuth susceptibility to low material the more metal artifacts It was found that the decrease. Therefore, based on the study on the increase, the metal artifacts reduction for the whole, as well as dental prosthesis future orthodontic materials in a way that can even reduce the artifact does not appear which has been pointed out as a disadvantage of the solutions of conventional metal artifact It is considered to be material.

Consideration of the Usefulness of 18F-FET Brain PET/CT in Brain Tumor Diagnosis (뇌종양진단에 있어 18F-FET Brain PET/CT의 유용성에 대한 고찰)

  • Kyu-Ho Yeon; Jae-Kwang Ryu
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.41-47
    • /
    • 2024
  • Purpose: 18F-FET, a radiopharmaceutical based on a Tyrosine amino acid derivative using the Sodium-Potassium Pump-independent Transporter (System L) for non-invasive evaluation of primary, recurrent, and metastatic brain tumors, exhibits distinct characteristics. Unlike the widely absorbed 18F-FDG in both tumor and normal brain tissues, 18F-FET demonstrates specific uptake only in tumor tissue while almost negligible uptake in normal brain tissue. This study aims to compare and evaluate the usefulness of 18F-FDG and 18F-FET Brain PET/CT quantitative analysis in brain tumor diagnosis. Materials and Methods: In 46 patients diagnosed with brain gliomas (High Grade: 34, Low Grade: 12), Brain PET/CT scans were performed at 40 minutes after 18F-FDG injection and at 20 minutes (early) and 80 minutes (delay) after 18F-FET injection. SUVmax and SUVpeak of tumor areas corresponding to MRI images were measured in each scan, and the SUVmax-to-SUVpeak ratio, an indicator of tumor prognosis, was calculated. Differences in SUVmax, SUVpeak, and SUVmax-to-SUVpeak ratio between 18F-FDG and 18F-FET early/delay scans were statistically verified using SPSS (ver.28) package program. Results: SUVmax values were 3.72±1.36 for 18F-FDG, 4.59±1.55 for 18F-FET early, and 4.12±1.36 for 18F-FET delay scans. The highest SUVmax was observed in 18F-FET early scans, particularly in HG tumors (4.85±1.44), showing a slightly more significant difference (P<0.0001). SUVpeak values were 3.33±1.13 for 18F-FDG, 3.04±1.11 for 18F-FET early, and 2.80±0.96 for 18F-FET delay scans. The highest SUVpeak was in 18F-FDG scans, while the lowest was in 18F-FET delay scans, with a more significant difference in HG tumors (P<0.001). SUVmax-to-SUVpeak ratio values were 1.11±0.09 for 18F-FDG, 1.54±0.22 for 18F-FET early, and 1.48±0.17 for 18F-FET delay scans. This ratio was higher in 18F-FET scans for both HG and LG tumors (P<0.0001), but there was no statistically significant difference between 18F-FET early and delay scans. Conclusion: This study confirms the usefulness of early and delay scans in 18F-FET Brain PET/CT examinations, particularly demonstrating the changes in objective quantitative metrics such as SUVmax, SUVpeak, and introducing the SUVmax-to-SUVpeak ratio as a new evaluation metric based on the degree of tumor malignancy. This is expected to further contributions to the quantitative analysis of Brain PET/CT images.

The evaluation of the feasibility about prostate SBRT by analyzing interfraction errors of internal organs (분할치료간(Interfraction) 내부 장기 움직임 오류 분석을 통한 전립선암의 전신정위적방사선치료(SBRT) 가능성 평가)

  • Hong, soon gi;Son, sang joon;Moon, joon gi;Kim, bo kyum;Lee, je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.179-186
    • /
    • 2016
  • Purpose : To figure out if the treatment plan for rectum, bladder and prostate that have a lot of interfraction errors satisfies dosimetric limits without adaptive plan by analyzing MR image. Materials and Methods : This study was based on 5 prostate cancer patients who had IMRT(total dose: 70Gy) Using ViewRay MRIdian System(ViewRay, ViewRay Inc., Cleveland, OH, USA) The treatment plans were made on the same CT images to compare with the plan quality according to adaptive plan, and the Eclipse(Ver 10.0.42, Varian, USA) was used. After registrate the 5 treatment MR images to the CT images for treatment plan to analyze the interfraction changes of organ, we measured the dose volume histogram and the changes of the absolute volume for each organ by appling the first treatment plan to each image. Over 5 fractions, the total dose for PTV was $V_{36.25}$ Gy $${\geq_-}$$ 95%. To confirm that the prescription dose satisfies the SBRT dose limit for prostate, we measured $V_{100%}$, $V_{95%}$, $V_{90%}$ for CTV and $V_{100%}$, $V_{90%}$, $V_{80%}$ $V_{50%}$ of rectum and bladder. Results : All dose average value of CTV, rectum and bladder satisfied dose limit, but there was a case that exceeded dose limit more than one after analyzing the each image of treatment. After measuring the changes of absolute volume comparing the MR image of the first treatment plan with the one of the interfraction treatment, the difference values were maximum 1.72 times at rectum and maximum 2.0 times at bladder. In case of rectum, the expected values were planned under the dose limit, on average, $V_{100%}=0.32%$, $V_{90%}=3.33%$, $V_{80%}=7.71%$, $V_{50%}=23.55%$ in the first treatment plan. In case of rectum, the average of absolute volume in first plan was 117.9 cc. However, the average of really treated volume was 79.2 cc. In case of CTV, the 100% prescription dose area didn't satisfy even though the margin for PTV was 5 mm because of the variation of rectal and bladder volume. Conclusion : There was no case that the value from average of five fractions is over the dosimetric limits. However, dosimetric errors of rectum and bladder in each fraction was significant. Therefore, the precise delivery is needed in case of prostate SBRT. The real-time tracking and adaptive plan is necessary to meet the precision delivery.

  • PDF

Usefulness of High-B-value Diffusion - Weighted MR Imaging for the Pre-operative Detection of Rectal Cancers (B-values 변환 자기공명영상: 국소 직장암 수술 전 검출을 위한 적합한 b-value 유용성)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Lee, Sun-Yeob;Park, Cheol-Soo;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.683-690
    • /
    • 2009
  • The purpose of this study is to evaluate the usefulness of high-b-values diffusion weighted magnetic resonance imaging for the preoperative detection of focal rectum cancers. 60patients with diffusion weighted imaging were evaluated for the presence of rectal cancers. Forty were male and twenty were female, and their ages ranged from 38 to 71 (mean, 56) years. Used equipment was 1.5Tesla MRI((GE, General Electric Medical System, Excite HD). Examination protocols were used the fast spin echo T2, T1 weighted imaging. All examination protocols were performed by the same location with diffusion weighted imaging for accuracy detection. The b-values used in DWI were 250, 500, 750, 1000. 1500, 2000$(s/mm^2)$. The rectum, bladder to tumor contrast-to-noise ratio (CNR) of MR images were quantitativlely analyzed using GE software Functool tool, four experienced radiologists and three radiotechnologists qualitatively evaluated image quality in terms of image artifacts, lesion conspicuity and rectal wall. These data were analysed by using ANOVA and Freedman test with each b-value(p<0.05). Contrast to noise ratio of rectum, bladder and tumor in b-value 1000 were 27.21, 24.44, respectively(p<0.05) and aADC value was $0.73\times10^{-3}$. As a qualitative analysis, the conspicuity and discrimination from the rectal wall of lesions were high results as $4.0\pm0.14$, $4.4\pm0.16$ on b-value 1000(p<0.05), image artifacts were high results as $4.8\pm0.25$ on b-value 2000(p<0.05). In conclusion, DWI was provided useful information with depicting the pre-operative detection of rectal cancers, High-b-value 1000 image was the most excellent DWI value.