• Title/Summary/Keyword: MRI contrast

Search Result 504, Processing Time 0.028 seconds

Usefulness of High-B-value Diffusion - Weighted MR Imaging for the Pre-operative Detection of Rectal Cancers (B-values 변환 자기공명영상: 국소 직장암 수술 전 검출을 위한 적합한 b-value 유용성)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Lee, Sun-Yeob;Park, Cheol-Soo;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.683-690
    • /
    • 2009
  • The purpose of this study is to evaluate the usefulness of high-b-values diffusion weighted magnetic resonance imaging for the preoperative detection of focal rectum cancers. 60patients with diffusion weighted imaging were evaluated for the presence of rectal cancers. Forty were male and twenty were female, and their ages ranged from 38 to 71 (mean, 56) years. Used equipment was 1.5Tesla MRI((GE, General Electric Medical System, Excite HD). Examination protocols were used the fast spin echo T2, T1 weighted imaging. All examination protocols were performed by the same location with diffusion weighted imaging for accuracy detection. The b-values used in DWI were 250, 500, 750, 1000. 1500, 2000$(s/mm^2)$. The rectum, bladder to tumor contrast-to-noise ratio (CNR) of MR images were quantitativlely analyzed using GE software Functool tool, four experienced radiologists and three radiotechnologists qualitatively evaluated image quality in terms of image artifacts, lesion conspicuity and rectal wall. These data were analysed by using ANOVA and Freedman test with each b-value(p<0.05). Contrast to noise ratio of rectum, bladder and tumor in b-value 1000 were 27.21, 24.44, respectively(p<0.05) and aADC value was $0.73\times10^{-3}$. As a qualitative analysis, the conspicuity and discrimination from the rectal wall of lesions were high results as $4.0\pm0.14$, $4.4\pm0.16$ on b-value 1000(p<0.05), image artifacts were high results as $4.8\pm0.25$ on b-value 2000(p<0.05). In conclusion, DWI was provided useful information with depicting the pre-operative detection of rectal cancers, High-b-value 1000 image was the most excellent DWI value.

A Study on Usefulness of Specific Agents with Liver Disease at MRI Imaging: Comparison with Ferucarbotran and Gd-EOB-DTPA Contrast Agents (간 병변 특이성 조영제 자기공명영상에 대한 연구: Ferucarbotran과 Gd-EOB-DTPA 조영제의 비교)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Park, Cheol-Soo;Lee, Sun-Yeob;Choi, Yong-Seok
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.235-243
    • /
    • 2009
  • The purpose of this experiment is to know the relation of the detection and characterization of liver's diseases as comparison of finding at MR imaging using a Ferucarbotran (SPIO) and Gd-EOB-DTPA (Primovist) agents in diffuse liver disease. A total of 50 patients (25 men and 25 women, mean age: 50 years) with liver diseases were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) "with 8 Ch body coil for comparison of diseases and contrast's uptake relation, which used the LAVA, MGRE." All images were performed on the same location with before and after Ferucarbotran and Gd-EOB-DTPA administrations (p<0.05). Contrast to noise ratio of Ferucarbotran and Gd-EOB-DTPA in the HCC were $3.08{\pm}0.12$ and $7.00{\pm}0.27$ with MGRE and LAVA pulse sequence, $3.62{\pm}0.13$ and $2.60{\pm}0.23$ in the hyper-plastic nodule, $1.70{\pm}0.09$ and $2.60{\pm}0.23$ in the meta, $2.12{\pm}0.28$ and $5.86{\pm}0.28$ in the FNH, $4.45{\pm}0.28$ and $1.73{\pm}0.02$ in the abscess and ANOVA test was used to evaluate the diagnostic performance of each disease (p<0.05). In conclusions, two techniques were well demonstrated with the relation of the detection and characterization of liver's diseases.

  • PDF

The Synthesis and MR Properties of New Macromolecular MR Contrast Agent (새로운 거대분자 MR 조영제의 합성 및 MR 특성에 관한 연구)

  • 장용민;장영환;황문정;박현정;전경녀;이종민;배경수;강봉석
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.35-40
    • /
    • 2002
  • Purpose : To evaluate the NMR relaxation properties and imaging characteristics of tissue-specificity for a newly developed macromolecular MR agent. Materials and methods : Phthalocyanine (PC) was chelated with paramagnetic ion, Mn.2.01g (5.2 mmol) of Phthalocyanine was mixed with 0.37g (1.4 mmol) of Mn chloride at $310^{\circ}C$ for 36 hours and then purified by chromatography (CHC13/CH3OH 98/2 v/v, Rf, 0.76) to obtain 1.04g (46%) of MnPC (molecular weight= 2000d). The $T1}T2$ relaxivity of MnPC was measured in 1.5T(64 MHz) MR using 0.1 mM MnPC. The MR image characteristics of MnPC was evaluated using spin-echo (TR/TE=500/14 msec) and gradient-echo (FLASH) (TR/TE=80/4 msec, flip angle=60) techniques in 1.57 MR scanner. The images of rabbit liver were obtained every 10 minutes up to 4 hours. To study the effect of concentration on image, 20 mM, 50 mM, 100 mM of MnPC were tested. Results : The relaxivities of MnPC at 1.5T(64MHz) were Rl=7.28 $mM^{-1}S^{-1},{\;}R2=55.56mM^{-1}S^{-1}$. Compared to the values of Gd-DTPA (Rl[=4.8 $mM^{-1}S^{-1})$], R2[=5.2 $mM^{-1}S^{-1}])$]), both T1/T2 relaxivities of MnPC were higher than those of Gd-DTPA. For both of SE and FLASH techniques, the contrast enhancement reached maximum at 10 minutes after bolus injection and the enhancement continued for more than 2 hours. When compared with small molecular weight liver agents such as Gd-EOB-DTPA, Gd-BOPTA and MnDPDP, MnPC was characterized by more prolonged enhancement time. The time course of MR images also revealed biliary excretion of MnPC. Conclusion : We developed a new macromolecular MR agent, MnPC. The relaxivities of MnPC were higher than those of small molecular weight Gd-chelate. Hepatic uptake and biliary excretion of MnPC suggests that this agent is a new liver-specific MR agent.

  • PDF

The Comparative Analysis Study and Usability Assessment of Fat Suppressed 3D T2* weighted Technique and Fat Suppressed 3D SPGR Technique when Examining MRI for Knee Joint Cartilage Assesment (슬관절 연골 평가를 위한 자기공명영상 검사 시 지방 신호 억제 3D T2* Weighted 기법과 지방 신호 억제 3D SPGR 기법의 비교 및 유용성 평가)

  • Kang, Sung-Jin
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.6
    • /
    • pp.219-225
    • /
    • 2016
  • In this study, for assessment of degenerative knee joint cartilage disease we acquired images by fat suppressed 3D spoiled gradient recalled (SPGR) and fat suppressed 3D $T2^*$ weighted imaging techniques. To do a quantitative evaluation, the knee joint cartilage was divided into medial femoral cartilage (MFC), medial tibial cartilage (MTC), lateral femoral cartilage (LFC), lateral femoral cartilage (LFC) and patella cartilage (Pat) to measure their respective signal intensity values, signal-to-noise ratio, and contrast-to-noise ratio. As for the measured values, statistical significance between two techniques was verified by using Mann-Whitney U-Test. To do a qualitative evaluation, two radiologists have examined images by techniques after which image artifact, cartilage surface, tissue contrast, and depiction of lesion distinguishing were evaluated based on 4-point scaling (1: bad, 2: appropriate, 3: good, 4: excellent), and based on the result, statistical significance was verified by using Kappa-value Test. 3.0T MR system and HD T/R 8ch knee array coil were used to acquire images. As a result of a quantitative analysis, based on SNR values measured by using two imaging techniques, MFC, LFC, LTC, and Pat showed statistical significance (p < 0.05), but MTC did not (p > 0.05). As a result of verifying statistical significance for measured CNR value, MFC, LFC, and Pat showed statistical significance (p < 0.05), while MTC and LTC did not show statistical significance (p > 0.05). As a result of a qualitative analysis, by comparing mean values for evaluated image items, 3D $T2^*$ weighted Image has indicated a slightly higher value. As for conformance verification between the two observers by using Kappa-value test, all evaluated items have indicated statistically significant results (p < 0.05). 3D $T2^*$ weighted technique holds a clinical value equal to or superior to 3D SPGR technique with respect to evaluating images, such as distinguishing knee joint cartilages, comparing nearby tissues contrast, and distinguishing lesions.

Tc-99m ECD Brain SPECT in MELAS Syndrome and Mitochondrial Myopathy: Comparison with MR findings (MELAS 증후군과 미토콘드리아 근육병에서의 Tc-99m ECD 뇌단일 광전자방출 전산화단층촬영 소견: 자기공명영상과의 비교)

  • Park, Sang-Joon;Ryu, Young-Hoon;Jeon, Tae-Joo;Kim, Jai-Keun;Nam, Ji-Eun;Yoon, Pyeong-Ho;Yoon, Choon-Sik;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.490-496
    • /
    • 1998
  • Purpose: We evaluated brain perfusion SPECT findings of MELAS syndrome and mitochondrial myopathy in correlation with MR imaging in search of specific imaging features. Materials and Methods: Subjects were five patients (four females and one male; age range, 1 to 25 year) who presented with repeated stroke-like episodes, seizures or developmental delay or asymptomatic but had elevated lactic acid in CSF and serum. Conventional non-contrast MR imaging and Tc-99m-ethyl cysteinate dimer (ECD) brain perfusion SPECT were Performed and imaging features were analyzed. Results: MRI demonstrated increased T2 signal intensities in the affected areas of gray and white matters mainly in the parietal (4/5) and occipital lobes (4/5) and in the basal ganglia (1/5), which were not restricted to a specific vascular territory. SPECT demonstrated decreased perfusion in the corresponding regions of MRI lesions. In addition, there were perfusion defects in parietal (1 patient), temporal (2), and frontal (1) lobes and basal ganglia (1) and thalami (2). In a patient with mitochondrial myopathy who had normal MRI, decreased perfusion was noted in left parietal area and bilateral thalami. Conclusion: Tc-99m ECD SPECT imaging in patients with MELAS syndrome and mitochondrial myopathy showed hypoperfusion of parieto-occipital cortex, basal ganglia, thalamus and temporal cortex, which were not restricted to a specific vascular territory. There were no specific imaging features on SPECT. The significance of abnormal perfusion on SPECT without corresponding MR abnormalities needs to be evaluated further in larger number of patients.

  • PDF

Transient Splenial Lesions in the Splenium of Corpus Callosum in Seven Patients: MR Findings and Clinical Correlations (뇌량 팽대의 일과성 병변: 7명의 환자에서의 자기공명 영상소견과 임상 양상의 연관성)

  • Park, Ju Young;Lee, In Ho;Song, Chang June;Hwang, Hee Youn
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose : The purpose of this study is to correlate the imaging findings and the clinical findings in patients with transient splenial lesions (TSL). Materials and Methods: Total of 7 patients (M: F = 4: 3; age range 11 - 38 years, mean age 25.5 years) were studied between November 2006 and April 2011. The MRI findings and clinical findings in all patients were retrospectively reviewed. The location, MR signal intensity, restricted diffusion, enhancement pattern and reversibility from the follow up images were reviewed. Clinical features were reviewed with respect to the presented symptoms, signs, treatment and outcome. Results: The lesions were located in the splenium of corpus callosum in all patients. All lesions showed high signal intensity on diffusion weighted imaging (DWI), and six patients showed restricted diffusion on the apparent diffusion coefficient (ADC) map. ADC map was not available in one patient. All lesions (n = 7) showed high signal intensity on the T2 weighted image (T2WI). Five of the patients (71.4%) with follow up images (range 7 - 34 days) showed complete resolution of focal high signal intensity on DWI, with recovery of ADC values as well as T2WI. After contrast media administration, none of the lesions showed any enhancements. All lesions with various etiologies including TB medication were developed in younger age patients and showed reversibility after the acceptable period of minimum 7 days with conservative treatment. Conclusion: All TSL showed nonspecific imaging findings, including restricted diffusion on DWI and ADC map on the initial images. However, reversibility of the lesions and the young age preference can be a characteristic finding of TSL with acceptable period of minimum 7 days. In addition, to keep it in mind that various etiologies including TB medication may cause TSL, is important for radiologists as well as clinicians.

A Study on the Image Quality According to the Change of Flip Angle in Flow-Related Enhancement Magnetic Resonance Angiography (유속증강 자기공명혈관조영술에서 숙임각 변화에 따른 영상의 질 연구)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.201-208
    • /
    • 2018
  • The purpose of this study was to investigate the optimal flip angle by measuring the SNR and CNR according to the angle of changes of the MRI technique using the Image J program. A total of 30 normal volunteers were assessed by using a 1.5T magnetic resonance imaging system (Philips, Medical System, Achieva). For the MRI angiography, we set the region of interest in four regions and evaluated the SNR and CNR. The statistical significance of SNR and CNR was calculated by one-way ANOVA using quantitative analysis at five different positions. The Bonferroni method was used for post-hoc analyzes. Statistical significance was determined by using ANOVA analysis at p<0.05 and Bonferroni method was used as a post-hoc analysis. The results of this study, the measurement values of ACA(SNR:$876.59{\pm}14.22$, CNR:$1999.7{\pm}12.5$), PCA(SNR:$863.48{\pm}13.29$, CNR:$1870.18{\pm}12.56$), ICA(SNR:$1116.87{\pm}08.34$, CNR:$2979.37{\pm}14.69$) and MCA(SNR:$848.66{\pm}15.25$, CNR:$2199.25{\pm}13.48$) were obtained with the high signal intensity at $25^{\circ}$(p<0.05). The values of a1, a2, a3, p1, p2, p3, m1, m2 and m3 were also the same (p<0.05). Post-hoc analysis results, There was a statistically significant difference (p=0.000) between $10^{\circ}$, $15^{\circ}$, $20^{\circ}$ on the $25^{\circ}$ reference for the flip angle, but no significant results were obtained with $30^{\circ}$(p<0.05). In concision, because the signal intensity decreased at $30^{\circ}$, this study revealed that the optimal flip angles were $25^{\circ}$ in cerebrovascular MR angiography.

Study of the Difference in Residual Amounts according to the Method of Securing Intravenous Injections and the Dose of Physiological Saline during 18F-FDG Administration (18F-FDG 투여 시 정맥주사 확보 방법 및 생리식염수 용량에 따른 잔류량의 차이에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.95-102
    • /
    • 2022
  • This study compares the difference between the remaining amount in syringes according to injection method and the dose of physiological saline when the radiopharmaceutical 18F-FDG isotope is injected into patients who visited the hospital for PET examination. After performing a CT or MRI using a contrast medium when 18F-FDG was injected into 40 patients who came to the hospital for PET examination without removing the 3-way, the radioactivity remaining in the syringe and the 3-way was measured and the dose of radioactivity confirmed. At this time, 20 patients were divided into different dose groups of physiological saline. Another injection method was used to compare the remaining amount of the syringe and the difference in the remaining amount according to the amount of physiological saline when the injection was performed with an extension. After an injection of 18F-FDG, the actual administered dose was confirmed by measuring the radioactivity remaining in the syringe and the 3-way or extension with a calibrator. As a result of measuring the radioactivity of the syringe before administering the radiopharmaceutical and the radioactivity of the syringe and the 3-way or extension after administration, the 3-way injection method in 10 cc's of physiological saline had the lowest residual amount. The remaining amount increased in the order of the extension to 10 cc's of saline and the 3-way to 5 cc's of saline. Likewise, the 5 cc's saline solution and the extension injection method demonstrated the highest residual amounts. The residual difference with the lowest level of remaining injection method was found to be 0.053 mCi. It was found that in a PET examination, by considering the radioactivity remaining in the 3-way and extension and by adjusting the dose of physiological saline, if the intended dose to be administered to the actual patient is determined, it is possible to administer the radiopharmaceutical to the patient more accurately.

LI-RADS Treatment Response versus Modified RECIST for Diagnosing Viable Hepatocellular Carcinoma after Locoregional Therapy: A Systematic Review and Meta-Analysis of Comparative Studies (국소 치료 후 잔존 간세포암의 진단을 위한 LI-RADS 치료 반응 알고리즘과 Modified RECIST 기준 간 비교: 비교 연구를 대상으로 한 체계적 문헌고찰과 메타분석)

  • Dong Hwan Kim;Bohyun Kim;Joon-Il Choi;Soon Nam Oh;Sung Eun Rha
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.331-343
    • /
    • 2022
  • Purpose To systematically compare the performance of liver imaging reporting and data system treatment response (LR-TR) with the modified Response Evaluation Criteria in Solid Tumors (mRECIST) for diagnosing viable hepatocellular carcinoma (HCC) treated with locoregional therapy (LRT). Materials and Methods Original studies of intra-individual comparisons between the diagnostic performance of LR-TR and mRECIST using dynamic contrast-enhanced CT or MRI were searched in MEDLINE and EMBASE, up to August 25, 2021. The reference standard for tumor viability was surgical pathology. The meta-analytic pooled sensitivity and specificity of the viable category using each criterion were calculated using a bivariate random-effects model and compared using bivariate meta-regression. Results For five eligible studies (430 patients with 631 treated observations), the pooled per-lesion sensitivities and specificities were 58% (95% confidence interval [CI], 45%-70%) and 93% (95% CI, 88%-96%) for the LR-TR viable category and 56% (95% CI, 42%-69%) and 86% (95% CI, 72%-94%) for the mRECIST viable category, respectively. The LR-TR viable category provided significantly higher pooled specificity (p < 0.01) than the mRECIST but comparable pooled sensitivity (p = 0.53). Conclusion The LR-TR algorithm demonstrated better specificity than mRECIST, without a significant difference in sensitivity for the diagnosis of pathologically viable HCC after LRT.

A study on image distortion improvement using silicon device in thyroid diffusion MRI images (갑상선의 확산강조영상 검사 시 실리콘 이용한 뒤틀림 감소에 관한 연구)

  • Choi, Kwan-Woo;Seo, Dae-Keon;Lee, Ho-Beom;Goh, Hee-Jin;Na, Sa-Ra;Han, Dong-Kyoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4380-4386
    • /
    • 2014
  • This study was conducted to minimize the imaging distortion by reducing the differences in susceptibility between the tissue and air surrounding it while performing a thyroid diffusion imaging procedure. The study group was composed of 23 healthy adults. Thyroids with many distortions near the air, larynx, and trachea were chosen to test and evaluate the diffusion imaging difference between before and after an application of silicon. As a result, there was reduced distortion with silicon application, and the differences decreased from 30% to 10%. According to One-way ANOVA and Duncan's post-hoc test, there were no significant differences between imaging with a silicon application and T2 imaging of the surface area, which was the standard image. In conclusion, this study presented a radical improvement in reducing the distortions in imaging by compensating for an uneven tissue surface near air without affecting the magnetic resonance contrast and complicating the imaging processes.