• Title/Summary/Keyword: MRI Images

Search Result 924, Processing Time 0.024 seconds

A Study of the Capsuloligamentous Anatomy of the Glenohumeral Joint Using Magnetic Resonance Imaging and Three-Dimensional Imaging. Dynamic In Vivo Study (자기공명 영상 및 3차원 영상을 이용한 견관절 관절낭-인대의 해부학적 연구. 역동학적 생체연구)

  • Park Tae-Soo;Choi Il-Yong;Joo Kyung-Bin;Kim Sun-Il;Kim Jun-Sic;Paik Doo-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.2
    • /
    • pp.154-158
    • /
    • 2000
  • Purpose : The purpose of this study is to demonstrate changes in the orientation ortho glenohumeral ligaments(GHL) in different degrees of abduction and rotation of the normal healthy individuals. Materials and Methods : Saline Magnetic Resonance(MR) arthrography of nine consecutive shoulders of normal healthy adults were checked. At that time, MR images were obtained in three different positions of abduction and external rotation($0^{\circ}C\;and\;0^{\circ},\;45^{\circ}C\;and\;25^{\circ}C,\;90^{\circ}$ and maximum, respectively). From a series of consecutive MRI, three-dimensional images were reconstructed after detecting the location of the middle glenohumeral ligament(MGHL) and the inferior glenohumeral ligament(IGHL) using workstation computer. Results : The shape of the MGHL was taken in double curved, and straight, and finally curved again in three different positions of the shoulder in sequence. On the other hand, the shape of the IGHL was obliquely positioned, and curvilinear, and finally straight and extended at lower part of the anterior surface of the humeral head. Conclusions : At $45^{\circ}$ of abduction and $25^{\circ}$ of external rotation, and at $90^{\circ}$ of abduction and maximal external rotation of the shoulder, the MGHL and the IGHL had the role of the most important static stabilizer of the glenohumeral joint repectively.

  • PDF

Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance (반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.581-588
    • /
    • 2019
  • MRI is superior when contrasted to help the organization generate artifacts resolution, but also affect the diagnosis and create a image that can not be read. Metal is inserted into the tooth, it is necessary to often be inhibited in imaging by causing the geometric distortion due to the majority and if the difference between the magnetic susceptibility of a ferromagnetic material or paramagnetic reducing them. The purpose of this study is to conduct a metal artefact in accordance with the analysis using a diamagnetic material. The magnetic material include a wire for the orthodontic bracket and a stainless steel was used as a diamagnetic material was used copper, zinc, bismuth. Testing equipment is sequenced using 1.5T, 3T was used was measured using a SE, TSE, GE, EPI. A self-produced phantom material was used for agarose gel (10%) to a uniform signal artifacts causing materials are stainless steel were tested by placing in the center of the phantom and cover inspection of the positive cube diamagnetic material of 10mm each length.After a measurement artefact artifact zone settings area was calculated using the Wand tool After setting the Low Threshold value of 10 in the image obtained by subtracting images, including magnetic material from a pure tool phantom images using Image J. Metal artifacts occur in stainless steel metal artifact reduction was greatest in the image with the bismuth diamagnetic materials of copper and zinc is slightly reduced, but the difference in degree will not greater. The reason for this is thought to be due to hayeotgi offset most of the susceptibility in bismuth diamagnetic susceptibility of most small ferromagnetic. Most came with less artifacts in image of bismuth in both 1.5T and 3T. Sequence-specific artifact reduction was most reduced artifacts from the TSE 1.5T 3T was reduced in the most artifacts from SE. Signal-to-noise ratio was the lowest SNR is low, appears in the implant, the 1.5T was the Implant + Bi Cu and Zn showed similar results to each other. Therefore, the results of artifacts variation of diamagnetic material, magnetic susceptibility (${\chi}$) is the most this shows the reduced aspect lower than the implant artificial metal artifacts criteria in the video using low bismuth susceptibility to low material the more metal artifacts It was found that the decrease. Therefore, based on the study on the increase, the metal artifacts reduction for the whole, as well as dental prosthesis future orthodontic materials in a way that can even reduce the artifact does not appear which has been pointed out as a disadvantage of the solutions of conventional metal artifact It is considered to be material.

The evaluation of the feasibility about prostate SBRT by analyzing interfraction errors of internal organs (분할치료간(Interfraction) 내부 장기 움직임 오류 분석을 통한 전립선암의 전신정위적방사선치료(SBRT) 가능성 평가)

  • Hong, soon gi;Son, sang joon;Moon, joon gi;Kim, bo kyum;Lee, je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.179-186
    • /
    • 2016
  • Purpose : To figure out if the treatment plan for rectum, bladder and prostate that have a lot of interfraction errors satisfies dosimetric limits without adaptive plan by analyzing MR image. Materials and Methods : This study was based on 5 prostate cancer patients who had IMRT(total dose: 70Gy) Using ViewRay MRIdian System(ViewRay, ViewRay Inc., Cleveland, OH, USA) The treatment plans were made on the same CT images to compare with the plan quality according to adaptive plan, and the Eclipse(Ver 10.0.42, Varian, USA) was used. After registrate the 5 treatment MR images to the CT images for treatment plan to analyze the interfraction changes of organ, we measured the dose volume histogram and the changes of the absolute volume for each organ by appling the first treatment plan to each image. Over 5 fractions, the total dose for PTV was $V_{36.25}$ Gy $${\geq_-}$$ 95%. To confirm that the prescription dose satisfies the SBRT dose limit for prostate, we measured $V_{100%}$, $V_{95%}$, $V_{90%}$ for CTV and $V_{100%}$, $V_{90%}$, $V_{80%}$ $V_{50%}$ of rectum and bladder. Results : All dose average value of CTV, rectum and bladder satisfied dose limit, but there was a case that exceeded dose limit more than one after analyzing the each image of treatment. After measuring the changes of absolute volume comparing the MR image of the first treatment plan with the one of the interfraction treatment, the difference values were maximum 1.72 times at rectum and maximum 2.0 times at bladder. In case of rectum, the expected values were planned under the dose limit, on average, $V_{100%}=0.32%$, $V_{90%}=3.33%$, $V_{80%}=7.71%$, $V_{50%}=23.55%$ in the first treatment plan. In case of rectum, the average of absolute volume in first plan was 117.9 cc. However, the average of really treated volume was 79.2 cc. In case of CTV, the 100% prescription dose area didn't satisfy even though the margin for PTV was 5 mm because of the variation of rectal and bladder volume. Conclusion : There was no case that the value from average of five fractions is over the dosimetric limits. However, dosimetric errors of rectum and bladder in each fraction was significant. Therefore, the precise delivery is needed in case of prostate SBRT. The real-time tracking and adaptive plan is necessary to meet the precision delivery.

  • PDF

Usefulness of High-B-value Diffusion - Weighted MR Imaging for the Pre-operative Detection of Rectal Cancers (B-values 변환 자기공명영상: 국소 직장암 수술 전 검출을 위한 적합한 b-value 유용성)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Lee, Sun-Yeob;Park, Cheol-Soo;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.683-690
    • /
    • 2009
  • The purpose of this study is to evaluate the usefulness of high-b-values diffusion weighted magnetic resonance imaging for the preoperative detection of focal rectum cancers. 60patients with diffusion weighted imaging were evaluated for the presence of rectal cancers. Forty were male and twenty were female, and their ages ranged from 38 to 71 (mean, 56) years. Used equipment was 1.5Tesla MRI((GE, General Electric Medical System, Excite HD). Examination protocols were used the fast spin echo T2, T1 weighted imaging. All examination protocols were performed by the same location with diffusion weighted imaging for accuracy detection. The b-values used in DWI were 250, 500, 750, 1000. 1500, 2000$(s/mm^2)$. The rectum, bladder to tumor contrast-to-noise ratio (CNR) of MR images were quantitativlely analyzed using GE software Functool tool, four experienced radiologists and three radiotechnologists qualitatively evaluated image quality in terms of image artifacts, lesion conspicuity and rectal wall. These data were analysed by using ANOVA and Freedman test with each b-value(p<0.05). Contrast to noise ratio of rectum, bladder and tumor in b-value 1000 were 27.21, 24.44, respectively(p<0.05) and aADC value was $0.73\times10^{-3}$. As a qualitative analysis, the conspicuity and discrimination from the rectal wall of lesions were high results as $4.0\pm0.14$, $4.4\pm0.16$ on b-value 1000(p<0.05), image artifacts were high results as $4.8\pm0.25$ on b-value 2000(p<0.05). In conclusion, DWI was provided useful information with depicting the pre-operative detection of rectal cancers, High-b-value 1000 image was the most excellent DWI value.

A Study on Usefulness of Specific Agents with Liver Disease at MRI Imaging: Comparison with Ferucarbotran and Gd-EOB-DTPA Contrast Agents (간 병변 특이성 조영제 자기공명영상에 대한 연구: Ferucarbotran과 Gd-EOB-DTPA 조영제의 비교)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Park, Cheol-Soo;Lee, Sun-Yeob;Choi, Yong-Seok
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.235-243
    • /
    • 2009
  • The purpose of this experiment is to know the relation of the detection and characterization of liver's diseases as comparison of finding at MR imaging using a Ferucarbotran (SPIO) and Gd-EOB-DTPA (Primovist) agents in diffuse liver disease. A total of 50 patients (25 men and 25 women, mean age: 50 years) with liver diseases were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) "with 8 Ch body coil for comparison of diseases and contrast's uptake relation, which used the LAVA, MGRE." All images were performed on the same location with before and after Ferucarbotran and Gd-EOB-DTPA administrations (p<0.05). Contrast to noise ratio of Ferucarbotran and Gd-EOB-DTPA in the HCC were $3.08{\pm}0.12$ and $7.00{\pm}0.27$ with MGRE and LAVA pulse sequence, $3.62{\pm}0.13$ and $2.60{\pm}0.23$ in the hyper-plastic nodule, $1.70{\pm}0.09$ and $2.60{\pm}0.23$ in the meta, $2.12{\pm}0.28$ and $5.86{\pm}0.28$ in the FNH, $4.45{\pm}0.28$ and $1.73{\pm}0.02$ in the abscess and ANOVA test was used to evaluate the diagnostic performance of each disease (p<0.05). In conclusions, two techniques were well demonstrated with the relation of the detection and characterization of liver's diseases.

  • PDF

Detection of Hepatic Lesion: Comparison of Free-Breathing and Respiratory-Triggered Diffusion-Weighted MR imaging on 1.5-T MR system (국소 간 병변의 발견: 1.5-T 자기공명영상에서의 자유호흡과 호흡유발 확산강조 영상의 비교)

  • Park, Hye-Young;Cho, Hyeon-Je;Kim, Eun-Mi;Hur, Gham;Kim, Yong-Hoon;Lee, Byung-Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.22-31
    • /
    • 2011
  • Purpose : To compare free-breathing and respiratory-triggered diffusion-weighted imaging on 1.5-T MR system in the detection of hepatic lesions. Materials and Methods: This single-institution study was approved by our institutional review board. Forty-seven patients (mean 57.9 year; M:F = 25:22) underwent hepatic MR imaging on 1.5-T MR system using both free-breathing and respiratory-triggered diffusion-weighted imaging (DWI) at a single examination. Two radiologists retrospectively reviewed respiratory-triggered and free-breathing sets (B50, B400, B800 diffusion weighted images and ADC map) in random order with a time interval of 2 weeks. Liver SNR and lesion-to-liver CNR of DWI were calculated measuring ROI. Results : Total of 62 lesions (53 benign, 9 malignant) that included 32 cysts, 13 hemangiomas, 7 hepatocellular carcinomas (HCCs), 5 eosinophilic infiltration, 2 metastases, 1 eosinophilic abscess, focal nodular hyperplasia, and pseudolipoma of Glisson's capsule were reviewed by two reviewers. Though not reaching statistical significance, the overall lesion sensitivities were increased in respiratory-triggered DWI [reviewer1: reviewer2, 47/62(75.81%):45/62(72.58%)] than free-breathing DWI [44/62(70.97%):41/62(66.13%)]. Especially for smaller than 1 cm hepatic lesions, sensitivity of respiratory-triggered DWI [24/30(80%):21/30(70%)] was superior to free-breathing DWI [17/30(56.7%):15/30(50%)]. The diagnostic accuracy measuring the area under the ROC curve (Az value) of free-breathing and respiratory-triggered DWI was not statistically different. Liver SNR and lesion-to-liver CNR of respiratory-triggered DWI ($87.6{\pm}41.4$, $41.2{\pm}62.5$) were higher than free-breathing DWI ($38.8:{\pm}13.6$, $24.8{\pm}36.8$) (p value < 0.001, respectively). Conclusion: Respiratory-triggered diffusion-weighted MR imaging seemed to be better than free-breathing diffusion-weighted MR imaging on 1.5-T MR system for the detection of smaller than 1 cm lesions by providing high SNR and CNR.

Local Shape Analysis of the Hippocampus using Hierarchical Level-of-Detail Representations (계층적 Level-of-Detail 표현을 이용한 해마의 국부적인 형상 분석)

  • Kim Jeong-Sik;Choi Soo-Mi;Choi Yoo-Ju;Kim Myoung-Hee
    • The KIPS Transactions:PartA
    • /
    • v.11A no.7 s.91
    • /
    • pp.555-562
    • /
    • 2004
  • Both global volume reduction and local shape changes of hippocampus within the brain indicate their abnormal neurological states. Hippocampal shape analysis consists of two main steps. First, construct a hippocampal shape representation model ; second, compute a shape similarity from this representation. This paper proposes a novel method for the analysis of hippocampal shape using integrated Octree-based representation, containing meshes, voxels, and skeletons. First of all, we create multi-level meshes by applying the Marching Cube algorithm to the hippocampal region segmented from MR images. This model is converted to intermediate binary voxel representation. And we extract the 3D skeleton from these voxels using the slice-based skeletonization method. Then, in order to acquire multiresolutional shape representation, we store hierarchically the meshes, voxels, skeletons comprised in nodes of the Octree, and we extract the sample meshes using the ray-tracing based mesh sampling technique. Finally, as a similarity measure between the shapes, we compute $L_2$ Norm and Hausdorff distance for each sam-pled mesh pair by shooting the rays fired from the extracted skeleton. As we use a mouse picking interface for analyzing a local shape inter-actively, we provide an interaction and multiresolution based analysis for the local shape changes. In this paper, our experiment shows that our approach is robust to the rotation and the scale, especially effective to discriminate the changes between local shapes of hippocampus and more-over to increase the speed of analysis without degrading accuracy by using a hierarchical level-of-detail approach.

Usefulness about BSGI (Breast Specific Gamma Imaging) in Breast Cancer Patients (유방암 환자에서 Breast Specific Gamma Imaging (BSGI)의 유용성)

  • Cho, Yong-Gwi;Pyo, Seong-Jae;Kim, Bong-Su;Shin, Chea-Ho;Cho, Jin-Woo;Yeo, Ji-Yeon;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.92-101
    • /
    • 2009
  • Purpose: Scintimammography is one of the screening tests for the early diagnosis of breast cancer. It has been widely accepted as very useful in assessing masses that have not been detected in breast scanning. This method is highly sensitive and specific with respect to the diagnosis of primary and relapsing breast cancer. It has some difficulties, however, in detecting tumors sized 1 cm and below due to the radioactivity around the breast and the geometrical structure of the equipment. The recent introduction of high-resolution Breast-specific Gamma Imaging (BSGI) has made it possible to more accurately discriminate between malignant and benign tumors than with any other test method. Thus, the possibility of an unnecessary biopsy being performed has decreased. The purpose of this study was to examine the diagnostic capacity of mammography, breast sonography, and scintimammography, which are used for the early diagnosis of known breast cancer, and of BSGI, and to evaluate the skillfulness of radiologists. Materials and Methods: The 53 volunteers participants who had no clinical manifestation of breast cancer underwent the BSGI in February 2009. In the BSGI procedure, scanning images were obtained from the craniocaudal projection (CC) and the mediolateral Oblique projection (MLO), as well as from the additional $80{\times}80$-matrix-sized views at various angles in the Present Time method, 10 minutes after the 25 mCi $^{99m}Tc$-MIBI was injected. Results: The results of the BSGI showed that two participants had masses in their breast tissue. As the results of the diagnosis of four participants were not clear, they were retested and the results of the second test were negative. The results of the clinical screening test for breast cancer showed that the sensitivity of BSGI, scintimammography, mammography, and breast sonography was 86.5%, 77.8%, 85~90%, and 66.7%, respectively, and that their specificity was 92.4%, 84.2%, 20~42%, and 68%, respectively. Conclusion: The autodiagnosis and breast cancer screening test are needed for the early diagnosis of breast cancer. It was not easy, however, to accurately determine the presence of a mass in the breast using the existing breast cancer screening test. The patients with unclear test findings were made to undergo a histologic biopsy for a more accurate diagnosis. It is expected that the BSGI can provide useful information for the early diagnosis of breast cancer and of primary breast cancer, and will reduce the performance of unnecessary biopsies because of its higher sensitivity and specificity than existing breast cancer screening tests.

  • PDF

Sequential 1H MR Spectroscopy(MRS) Studies of Kaolin-Induced Hydrocephalic Cat Brain (Kaolin 유발 고양이 수두증 모델에서 양자 자기공명 분광상의 경시적 변화)

  • Kim, Myung Jin;Hwang, Sung Kyoo;Hwang, Jeong Hyun;Chang, Yongmin;Kim, Yong Sun;Kim, Seung Lae
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.11
    • /
    • pp.1421-1428
    • /
    • 2000
  • Objectives : The aim of this study is to evaluate the sequential metabolic changes in experimental hydrocephalus and the clinical applicability to the diagnosis and prognosis of hydrocephalus using proton MR spectroscopy. Methods : Hydrocephalus was experimentally induced in 30 cats(2-3kg body weight) by injecting 1ml of sterile kaolin suspension(250mg/ml) into the cisterna magna. Proton MRS was performed with a 1.5 T MRI/MRS unit (Vision Plus, Siemens) at pre-treatment and at 1, 3, 7, 14, 21, and 28 days after the kaolin injection. PRESS(TR/TE=1500/270msec) technique was employed. The major metabolites which include N-acetyl aspartate (NAA), creatine(Cr), choline(Cho), and lactate(Lac) were quantitatively analyzed and the relative concentrations ratios were evaluated. Multislice $T_2$-weighted images were also obtained using fast spin echo sequence(TR/TE= 2500/96msec) to monitor the morphologic changes along with progression of hydrocephalus. Results : Hydrocephalus was successfully induced in all 30 cats. Twenty five cats died within 3 days and one at the end of the second week. In all animals, the NAA/Cr ratios initially decreased during the acute stage. In 4 surviving cats, the NAA/Cr ratios initially decreased during the acute stage(<14 days) and then gradually increased to the prekaolin level as follows : pre-kaolin($1.49{\pm}0.04$), day 1($1.11{\pm}0.07$), day 7($1.17{\pm}0.04$), day 14($1.40{\pm}0.03$), day 21 ($1.46{\pm}0.06$), day 28($1.43{\pm}0.03$). These levels were relatively well correlated with the symptomatologic improvement. Lactate peak, which reflects the evidence of ischemia, did not appear throughout the entire period except in one case which expired at the end of the second week. Conclusions : The NAA/Cr ratio of the sequential proton MRS in kaolin-induced hydrocephalic cats reflects a metabolic aspect of the hydrocephalus at each stage. A decreased NAA level at the early stage is from both neuronal and axonal damage which may provide diagnostic information in the acute stage of hydrocephalus. In addition, the initial fall of NAA/Cr ratio and recovery in the late stage, when no lactate peak emerges, may suggest that the main insult of the parenchyma is not to the neuron itself but to the axon, which may be related to a good prognosis. However, emergence of the lactate peak and unrecoverable NAA/Cr at the end of the acute phase may be a poor prognostic factor. In the chronic stage, recovery of NAA/Cr ratio may provide a diagnostic clue for the differentiation between hydrocephalus and cortical atrophy.

  • PDF

The Effect of Nuclear Overhauser Enhancement in Liver and Heart $^{31}P$ NMR Spectra Localized by 2D Chemical Shift Technique (이차원 화학변위 기법을 이용한 간 및 심장 $^{31}P$ 자기공명분광에서의 Nuclear Overhauser 효과에 대한 연구)

  • Ryeom Hun-Kyu;Lee Jongmin;Kim Yong-Sun;Lee Sang-Kwon;Suh Kyung-Jin;Bae Sung-Jin;Chang Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.94-99
    • /
    • 2004
  • Purpose : To investigate the signal enhancement ratio by NOE effect on in vivo $^{31}P$ MRS in human heart muscle and liver. we also evaluated the enhancement ratios of different phosphorus metabolites, which are important in 31P MRS for each organ. Materials and Methods : Ten normal subjects (M:F = 8:2, age range = 24-32 yrs) were included for in vivo $^{31}P$ MRS measurements on a 1.5 T whole-body MRI/MRS system using $^1H-^{31}P$ dual tuned surface coil. Two-dimensional Chemical Shift Imaging (2D CSI) pulse sequence for $^{31}P$ MRS was employed in all $^{31}P$ MRS measurements. First, $^{31}P$ MRS performed without NOE effect and then the same 2D CSI data acquisitions were repeated with NOE effect. After postprocessing the MRS raw data in the time domain, the signal enhancements in percent were estimated from the major metabolites. Results : The calculated NOE enhancement for liver $^{31}P$ MRS were $\alpha-ATP\;(7\%),\;\beta-ATP\;(9\%),\;\gamma-ATP\;(17\%),\;Pi\;(1\%),\;PDE\;(19\%)$ and $PME\;(31\%)$. Because there is no creatine kinase activity in liver, PCr signal is absent. For cardiac $^{31}P$ MRS, whole body coil gave better scout images and thus better localization than surface coil. In $^{31}P$cardiac multi-voxel spectra, DPG signal increased from left to right according to the amount of blood included. The calculated enhancement for cardiac $^{31}P$ MRS were : $\alpha-ATP\;(12\%),\;\beta-ATP\;(19\%),\;\gamma-ATP\;(30\%),\;PCr\;(34\%),\;Pi\;(20\%),\;(PDE)\;(51\%),\;and\;DPG\;(72\%)$. Conclusion : Our results revealed that the NOE effect was more pronounced in heart muscle than in liver with different coupling to 1H spin system and thus different heteronuclear cross-relaxation.

  • PDF