• Title/Summary/Keyword: MRI Image

Search Result 941, Processing Time 0.035 seconds

Software Implementation for 3D visualization of brain fiber tractography and high-resolution anatomical data

  • Oh, Jung-Su;Song, In-Chan;Ikhwan Cho;Kim, Jong-Hyo;Chang, Kee-Hyun;Park, Kwang-Suk
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.32-32
    • /
    • 2003
  • The purpose of paper is to implement a PC-based software for 3D visualization of brain fiber tractography and high-resolution anatomical data 서론: DTI (Diffusion tensor imaging) is a very useful noninvasive MRI technique for providing the direction and connectivity information of brain fiber tracts. Especially in patients with glioma, fiber tracts on the lesion side in the brain had varying degrees of displacement or disruption as a result of the tumor. Tract disruption resulted from direct tumor involvement, compression on the tract, and vasogenic edema surrounding the tumor. To combine information on fiber tracts surrounding turner with a high-resolution anatomical 3D image may be clinically useful for surgical planning. Therefore we implemented a software for visualizing both brain fiber tractography and anatomical data.

  • PDF

Software Implementation for 3D visualization of brain fiber tractography and high-resolution anatomical data

  • Oh, Jung-Su;Song, In-Chan;Ikhwan Cho;Kim, Jong-Hyo;Chang, Kee-Hyun;Park, Kwang-Suk
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.83-83
    • /
    • 2003
  • Purpose: The purpose of paper is to implement a PC-based software for 3D visualization of brain fiber tractography and high-resolution anatomical data introduction: DTI (Diffusion tensor imaging) is a very useful noninvasive MRI technique for providing the direction and connectivity information of brain fiber tracts. Especially in patients with glioma, fiber tracts on the lesion side in the brain had varying degrees of displacement or disruption as a result of the tumor. Tract disruption resulted from direct tumor involvement, compression on the tract, and vasogenic edema surrounding the tumor. To combine information on fiber tracts surrounding tumor with a high-resolution anatomical 3D image may be clinically useful for surgical planning. Therefore we implemented a software for visualizing both brain fiber tractography and anatomical data.

  • PDF

Segmentation and Visualization of Left Ventricle in MR Cardiac Images (자기공명심장영상의 좌심실 분할과 가시화)

  • 정성택;신일홍;권민정;박현욱
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.101-107
    • /
    • 2002
  • This paper presents a segmentation algorithm to extract endocardial contour and epicardial contour of left ventricle in MR Cardiac images. The algorithm is based on a generalized gradient vector flow(GGVF) snake and a prediction of initial contour(PIC). Especially. the proposed algorithm uses physical characteristics of endocardial and epicardial contours, cross profile correlation matching(CPCM), and a mixed interpolation model. In the experiment, the proposed method is applied to short axis MR cardiac image set, which are obtained by Siemens, Medinus, and GE MRI Systems. The experimental results show that the proposed algorithm can extract acceptable epicardial and endocardial walls. We calculate quantitative parameters from the segmented results, which are displayed graphically. The segmented left vents role is visualized volumetrically by surface rendering. The proposed algorithm is implemented on Windows environment using Visual C ++.

Splenic Hemochromatosis Incidentally Found on Tc-99m MDP Bone Scan in a Chronic Myelogenous Leukemia Patient who Received Bone Marrow Transplantation (골수 이식을 받은 만성 골수성 백혈병 환자의 Tc-99m MDP 골스캔에서 우연히 발견된 비장 Hemochromatosis)

  • Seo, Ji-Hyoung;Bae, Jin-Ho;Jeong, Sin-Young;Lee, Jae-Tae;Lee, Kyu-Bo;Ahn, Byeong-Cheol
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.109-110
    • /
    • 2004
  • Purpose: Tc-99m MDP bone scan was performed to evaluate a generalized bone pain in a 24-year-old male chronic myelogenous leukemia patient who received bone marrow transplantation at 7 months ago. The patient had received large amounts of blood transfusion for managing symptoms related to anemia. Bone scan revealed substantial splenic tracer uptake. Magnetic resonance image and laboratory evidence of hemochromatosis suggests that the presence of large quantities of iron in the spleen of this patient may have been responsible for the splenic uptake of the bone scanning agent. The authors report a case of splenic hemochromatosis incidentally found on Tc-99m MDP bone scan.

3-Dimensional Model Simulation Craniomaxillofacial Surgery using Rapid Prototyping Technique (신속 조형 기술로 제작된 인체모형을 이용한 술전 모의 두개악안면성형수술)

  • Jung, Kyung In;Baek, Rong-Min;Lim, Joo Hwan;Park, Sung Gyu;Heo, Chan Yeong;Kim, Myung Good;Kwon, Soon Sung
    • Archives of Plastic Surgery
    • /
    • v.32 no.6
    • /
    • pp.796-797
    • /
    • 2005
  • In plastic and reconstructive craniomaxillofacial surgery, careful preoperative planning is essential to get a successful outcome. Many craniomaxillofacial surgeons have used imaging modalities like conventional radiographs, computed tomography(CT) and magnetic resonance imaging(MRI) for supporting the planning process. But, there are a lot of limitations in the comprehension of the surgical anatomy with these modalities. Medical models made with rapid prototyping (RP) technique represent a new approach for preoperative planning and simulation surgery. With rapid prototyping models, surgical procedures can be simulated and performed interactively so that surgeon can get a realistic impression of complex structures before surgical intervention. The great advantage of rapid prototyping technique is the precise reproduction of objects from a 3-dimensional reconstruction image as a physical model. Craniomaxillofacial surgeon can establish treatment strategy through preoperative simulation surgery and predict the postoperative result.

Bilateral Shoulder Involvement with Mirror Image Lesion -An Arthroscopic Study in Overhead Workers (양측 견관절을 침범한 거울 병변 -머리 위의 작업을 하는 근로자 대상 관절경적 연구)

  • Moon, Young-Lae;Lee, Chul-Gab;Kim, Jong-Sik
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.1
    • /
    • pp.68-72
    • /
    • 2006
  • Purpose: To demonstrate arthroscopically the presence of bilateral shoulder "mirror lesions" due to overhead work. Materials and Methods: A cross-sectional study was performed in a historical cohort of 10 male tire plant workers who underwent MRI studies of both shoulders. Bilateral intraarticular shoulder pathology was diagnosed by magnetic resonance imaging and confirmed by arthroscopy. "Mirror lesions" were defined as similar pathology between an individual patient's two shoulders. Results: We report on ten patients who had bilateral "mirror lesions." The most common mirror lesions were tears of the rotator cuff. Most patients (7 of 10) had more than one mirror lesion in their shoulders. There were two bilateral full thickness tears involving the supraspinatus and infraspinatus, four bilateral partial thickness supraspinatus tears, six bilateral partial or upper corner lesion complete subscapularis tears, and one bilateral complete supraspinatus tear. Conclusion: Occupational overhead work with simultaneous use of both arms is associated with bilateral shoulder lesions verified by arthroscopy. By demonstrating the work-related bilateral shoulder involvement, this study suggests an etiopathogenesis for these lesions and provides rational for developing worksite prevention strategies.

Implementation of an Algorithm for Image Mapping of the Cerebral Perfusion Parameters using the Gamma-Variate Curve Fitting (Gamma-Variate 곡선 정합을 이용한 뇌관류 파라미터의 영상 Mapping 알고리즘 구현)

  • 이상민;강경훈;김재형;이건기;신태민
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.157-163
    • /
    • 2000
  • 최근 MR영상을 허혈성 뇌졸중의 초급성기에 뇌조직의 관류 이상을 조기에 진단하려는 연구들이 진행되고 있으나 아직 일반적인 진단용 소프트웨어만 있을 뿐 영상 자료를 후처리하여 뇌조직의 구조 및 기능적인 정보를 제공하는 mapping 영상을 특수 소프트웨어는 실용화되어 있지 않다. 본 논문에서는 Gamma-variate 곡선 정합을 이용한 뇌관류 파라미터 영상 mapping의 알고리즘 구현에 관해 연구하였다. 관류 MR영상의 각 화소마다 측정된 시간에 따른 신호강도의 변화 곡선은 비선형적이어서 뇌관류에 관한 여러 가지 혈역학적 변수들을 보다 정확하게 계산할 수 없었다. 그래서 수렴속도가 빠르고 안정성이 높은 비선형 최적화 알고리즘인 Levenberg-Marquardt 알고리즘(LMA)을 활용하였다. 즉 시간에 따른 신호강도의 변화 곡선을 Gamma-variate 함수를 이용하여 곡선 정합한 후, CBV, MTT, CBF, TTP, BAT, MS의 여러 가지 혈역학적 변수를 LMA에 의해 계산하였다. 그 결과로 관류 MR영상으로부터 얻은 mapping 영상은 초급성 허혈성 뇌졸중에서 관류에 관한 혈역학적 변화를 평가함으로써 나중에 생길 뇌경색의 범위를 예견하는 데에 유용하였다.

  • PDF

Effects of NEX on SNR and Artifacts in Parallel MR Images Acquired using Reference Scan

  • Heo, Yeong-Cheol;Lee, Hae-Kag;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.422-427
    • /
    • 2013
  • The aim of this study was to investigate effects of the number of acquisitions (NEX) on signal-to-noise (SNR) and artifacts in SENSE parallel imaging of magnetic resonance imaging (MRI). 3.0T MR System, 8 Channel sensitivity encoding (SENSE) head coils were used along with an in-vivo phantom. Reference sequence of 3D fast field echo (FFE) was consisted of NEX values of 2, 4, 6, 8, 10 and 12. The T2 turbo spin echo (TSE) sequence used for exams achieved SENSE factors of 1.2, 1.5, 1.8, 2.0, 2.2, 2.5, 2.8, 3.0, 3.2, 3.5, 3.8 and 4.0. Exams were conducted five times for each SENSE factor to measure signal intensity of the object, the posterior phase-encode direction and frequency direction. And SNR was calculated using mean values. SENSE artifacts were identified as background signal intensity in the phase-encoded direction using MRIcro. It was found that SNR increased but SENSE artifacts reduced with NEX of 4, 8 and 12 when the NEX increased in reference scan. It is therefore concluded that image quality can be improved with NEX of 4, 8 and 12 for reference scanning.

Evaluation of Modified Turbo Spin Echo Technique Compared with Double Inversion Recovery Technique in Acquisition of Black Blood Brain Vessel Image

  • Choi, Kwan-Woo;Lee, Ho-Beom;Na, Sa-Ra;Son, Soon-Yong
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.148-152
    • /
    • 2016
  • The main goal was to evaluate effectiveness of a modified TSE sequence compared with DIR (double inversion recovery) sequence in acquisition of fast flow brain vessel images using signal void effect. 32 healthy volunteers (10 men and 22 women; mean age of 31 years; ranging between 28-43 years) who underwent black blood DIR sequence (group A) and the modified TSE sequence (group B) were enrolled in our study. Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of the internal carotid arteries' lumen were compared in T1 and T2 weighted images for both group A and B. The images obtained from group B showed lower SNR values in internal carotid artery than the group A in both of the T1 and T2 weighted images (11.49% and 13.66% respectively). While the CNR values were higher in the group B than the group A in both of the T1 and T2 weighted images (8.69% and 7.55 % respectively). The qualitative score of all categories were not significantly different between the two groups. Furthermore approximately 49% of the total scan time was reduced from group B. Our study is to shorten the scanning time and minimize the inconveniences of the patients in acquisition of the black blood images of brain by using the signal void effect in the modified TSE technique while keeping the diagnostic value of the test.

Usefulness of the Technique of Collecting Signals by Selecting Elements from RF Receive Phase Array Coil in Magnetic Resonance Imaging (자기공명영상검사 시 Array coil에서 element를 선택하여 신호를 수집하는 기법의 유용성)

  • Choi, Kwan-Woo;Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.6
    • /
    • pp.461-466
    • /
    • 2018
  • In this study, we investigated the signal intensity changes by activating all and partially selected coil elements as a way to increase the SNR in a single region MR imaging. Two cylindrical fluid phantoms were placed side by side in a phase array coil and MRI scans were repeated by turning on the entire elements and selected elements. As a result, on both of the T1 and T2 weighted images signal intensities were significantly increased by 5.49% and 14.64%, respectively. In conclusion, if only a single region was to be imaged, selecting appropriate elements and collecting signals only from them could easily improve image qualities and signal intensities.