• Title/Summary/Keyword: MRI Image

Search Result 941, Processing Time 0.024 seconds

Clear Cell Sarcoma of the Wrist: MRI Findings with Diffusion-Weighted Image and Histopathologic Correlation

  • Chung, Bo Yong;Lee, Seun Ah;Choi, Jung-Ah;Shim, Jung-Weon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.2
    • /
    • pp.136-139
    • /
    • 2016
  • Clear cell sarcoma is rare and difficult to diagnose. Herein, we present a case of clear cell sarcoma in the dorsum of the wrist with MRI findings, including diffusion-weighted imaging, and histopathologic correlation, which was initially diagnosed as giant cell tumor of tendon sheath.

An Unusual Case of Japanese Encephalitis Involving Unilateral Deep Gray Matter and Temporal Lobe on Diffusion-Weighted MRI

  • Seok, Hee Young;Lee, Dong Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.250-253
    • /
    • 2016
  • Acute Japanese encephalitis (JE) is an endemic viral infectious disease in various parts of Far East and Southeast Asian countries including Korea. Bilateral thalami are the most common involving sites in JE. Other areas including the basal ganglia, substantia nigra, red nucleus, pons, cerebral cortex and cerebellum may be also involved. We report an extremely unusual brain diffusion-weighted MR imaging (DWI) findings in a 53-year-old man with serologically proven JE involving unilateral deep gray matter and temporal lobe, which shows multifocal high signal intensities in left thalamus, left substantia nigra, left caudate nucleus and left medial temporal cortex on T2-weighted image and DWI with iso-intensity on apparent diffusion coefficient (ADC) map.

MAGNETIC RESONANCE ELECTRICAL IMPEDANCE TOMOGRAPHY

  • Kwon, Oh-In;Seo, Jin-Keun;Woo, Eung-Je;Yoon, Jeong-Rock
    • Communications of the Korean Mathematical Society
    • /
    • v.16 no.3
    • /
    • pp.519-541
    • /
    • 2001
  • Magnetic Resonance Electrical Impedance Tomography(MREIT) is a new medical imaging technique for the cross-sectional conductivity distribution of a human body using both EIT(Electrical Impedance Tomography) and MRI(Magnetic Resonance Imaging) system. MREIT system was designed to enhance EIT imaging system which has inherent low sensitivity of boundary measurements to any changes of internal tissue conductivity values. MREIT utilizes a recent CDI (Current Density Imaging) technique of measuring the internal current density by means of MRI technique. In this paper, a mathematical modeling for MREIT and image reconstruction method called the alternating J-substitution algorithm are presented. Computer simulations show that the alternating J-substitution algorithm provides accurate high-resolution conductivity images.

  • PDF

Bilateral Cortical Blindness Caused by Tentorial Herniation due to Brain Tumor

  • Jeon, Jee-Ho;Hwang, Hyung-Sik;Moon, Seung-Myung;Choi, Sun-Kil
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.6
    • /
    • pp.421-424
    • /
    • 2007
  • Two patients, one with glioblastoma multiforme [GM] in the right thalamus and the other with meningioma at the right frontal convexity, had suffered bilateral cortical blindness after transtentorial herniation. On one of those patients, bilateral cortical blindness had occurred due to acute obstructive hydrocephalus caused by GM and on the other patient, cortical blindness had developed after acute hemorrhage from meningioma. Bilateral occipital lobes of those patients showed signal change on the brain magnetic resonance image [MRI]. There were no ophthalmologic abnormalities on fundoscopy and ophthalmologic examination. After recovery of consciousness, cortical blindness was detected in both patients, and during gradual recovery period, visual function was slowly recovered. The pattern of visual evoked potential [VEP] at 7 weeks and 12 weeks after herniation was normalized gradually. Cortical blindness due to herniation was reversible, even though the high signals of bilateral visual cortex still existed on MRI 16 month later in case 2.

Convolutional Neural Network-based Iris Lesion Classification Algorithm (CNN기반 알츠하이머 치매 중증도 판별 알고리즘 오차 검증)

  • Kim, June-Gyeom;Seo, Jin-Beom;Cho, Young-Bok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.100-101
    • /
    • 2021
  • In Korea, which has entered an aging society, 87% of the elderly population suffers from chronic diseases such as dementia and stroke, of which Alzheimer's dementia accounts for 71.3% of all dementia. In this paper, labeling verification was performed to review the error problem of deep learning results divided by Alzheimer's dementia MRI image into three stages.

  • PDF

Single Centre Experience on Decision Making for Mechanical Thrombectomy Based on Single-Phase CT Angiography by Including NCCT and Maximum Intensity Projection Images - A Comparison with Magnetic Resonance Imaging after Non-Contrast CT

  • Kim, Myeong Soo;Kim, Gi Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.2
    • /
    • pp.188-201
    • /
    • 2020
  • Objective : The purpose of this study was to suggest that computed tomography angiography (CTA) is valuable as the only preliminary examination for mechanical thrombectomy (MT). MT after single examination of CTA including noncontrast computed tomography (NCCT) and maximum intensity projection (MIP) improves door-to-puncture time as well as results in favorable outcomes. Methods : A total of 157 patients who underwent MT at Dong Kang Medical Center from April 2015 to March 2019 were divided into two groups based on the examination performed prior to MT : CTA group who underwent CTA with NCCT and MIP, and NCCT+magnetic resonance image (MRi) group who underwent MRI including perfusion images after NCCT. In the two groups, time to CTA imaging or NCCT+MRi imaging after symptom onset, and time to arterial puncture and reperfusion were characterized as time-related outcomes. The evaluation of vascular recanalization after MT was defined as a modified thrombolysis in cerebral infarction (mTICI) scale. National Institutes of Health Stroke Scale (NIHSS) was assessed at the time of the visit to the emergency room and modified Rankin Scale (mRS) was assessed after 90 days. Results : Typically, there were 34 patients in the CTA group and 33 patients in the NCCT+MRi group. A significantly shorter delay for door-to-puncture time was observed (mean, 86±22.1 vs. 176±47.5 minutes; <0.01). Also, a significantly shorter door-to-imege time in the CTA group was observed (mean, 13±6.8 vs. 93±30.8 minutes; p<0.01). Moreover, a significantly shorter onset-to-puncture time was observed (mean, 195±128.0 vs. 314±157.6 minutes; p<0.01). Reperfusion result of mTICI ≥2b was 100% (34/34) in the CTA group and 94% (31/33) in the NCCT+MRi group, and mTICI 3 in 74% (25/34) in the CTA group and 73% (24/33) in the NCCT+MRi group. Favorable functional outcomes (mRS score ≤2 at 90 days) were 68% (23/34) in the CTA group and 60% (20/33) in the NCCT+MRi group. Conclusion : A single-phase CTA including NCCT and MIP images was performed as a single preliminary examination, which led to a reduction in the time of the procedure and resulted in good results of prognosis. Consequently, it is concluded that this method is of sufficient value as the only preliminary examination for decision making.

Current Status of Imaging Physics & Instrumentation In Nuclear Medicine (핵의학 영상 물리 및 기기의 최신 동향)

  • Kim, Hee-Joung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.83-87
    • /
    • 2008
  • Diagnostic and functional imaging device have been developed independently. The recognition that combining of these two devices can provide better diagnostic outcomes by fusing anatomical and functional images. The representative examples of combining devices would be PET/CT and SPECT/CT. Development and their applications of animal imaging and instrumentation have been very active, as new drug development with advanced imaging device has been increased. The development of advanced imaging device resulted in researching and developing for detector technology and imaging systems. It also contributed to develop a new software, reconstruction algorithm, correction methods for physical factors, image quantitation, computer simulation, kinetic modeling, dosimetry, and correction for motion artifacts. Recently, development of MRI and PET by combining them together was reported. True integration of MRI and PET has been making the progress and their results were reported. The recent status of imaging and instrumentation in nuclear medicine is reported in this paper.

Imaging Anatomy of Waldeyer's Ring and PET/CT and MRI Findings of Oropharyngeal Non-Hodgkin's Lymphoma

  • Zhang, Chun-Xing;Liang, Long;Zhang, Bin;Chen, Wen-Bo;Liu, Hong-Jun;Liu, Chun-Ling;Zhou, Zheng-Gen;Liang, Chang-Hong;Zhang, Shui-Xing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3333-3338
    • /
    • 2015
  • Background: This study was conducted to analyze positron emission tomography (PET) / computed tomography (CT) and magnetic resonance imaging (MRI) performance with oropharyngeal non-Hodgkin's lymphoma (ONHL).Materials and Methods: The complete image data of 30 ONHL cases were analyzed, all patients were performed PET / CT and MRI examination before the treatment, with the time interval of these two inspections not exceeding 14 days. The distribution, morphology, MRI signal characteristics, enhancement feature, standardized uptake value (SUV) max value and lymph node metastasis way of the lesions were analyzed. Results: Among the 30 cases, 23 cases were derived from the B-cell (76.7%), 5 cases were derived from the peripheral T cells (16.7%) and 2 cases were derived from the NK/T cells (6.7%). 19 cases exhibited the palatine tonsil involvement (63.3%). As for the lesion appearance, 10 cases appeared as mass, 8 cases were the diffused type and 12 cases were the mixed type. 25 cases exhibited the SUVmax value of PET / CT primary lesions as 11 or more (83.3%). MRI showed that all patients exhibited various degrees of parapharyngeal side-compressed narrowing, but MRI still exhibited the high-signal fat, and the oropharyngeal mucosa was intact. 25 cases were associated with the neck lymph node metastasis, among who 22 cases had no necrosis in the metastatic lymph nodes, while the rest 3 cases exhibited the central necrosis in the metastatic lymph nodes. Conclusions: PET / CT and MRI have important value in diagnosing and determining the lesion extent of ONHL.

Improvement of High Permittivity Pads for Areas with Generally Low Signal Sensitivity at 7T MRI (7T MRI에서 일반적으로 신호 감도가 낮은 영역에 대한 고유전율 패드 개선)

  • Yong-Tae, Kim;Hyeon-Man, Baek
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.761-769
    • /
    • 2022
  • Pads with high dielectric materials have been used in a variety of applications to locally improve the field sensitivity and homogeneity of RF pulses in clinical MRI studies. In this study, we aimed to improve such pads in consideration of the practical problems associated with the application of actual clinical images. A high permittivity pad to increase the attenuated B1 field strength was fabricated and tested in 7T MRI. Sim4Life simulation and experimental results show stronger and relatively uniform B1 near field. In order to improve the image quality in the whole cerebellum, known as a region with low sensitivity, a guide was made to reduce the mechanical change of the pad. In order to improve the wearing comfort, the pad was designed by dividing it into upper and lower parts. The facial pad showed an overall signal increase effect in areas such as the turbinate in the nasal cavity. Signal increase was expected in areas such as the frontal lobe and eyes, but the effect was either insignificant or it was difficult to see the effect in the imaging protocol. In conclusion, this paper showed a cerebellar-optimized pad with an improved nasal signal while maintaining its effectiveness.

Multi-modality MEdical Image Registration based on Moment Information and Surface Distance (모멘트 정보와 표면거리 기반 다중 모달리티 의료영상 정합)

  • 최유주;김민정;박지영;윤현주;정명진;홍승봉;김명희
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.3_4
    • /
    • pp.224-238
    • /
    • 2004
  • Multi-modality image registration is a widely used image processing technique to obtain composite information from two different kinds of image sources. This study proposes an image registration method based on moment information and surface distance, which improves the previous surface-based registration method. The proposed method ensures stable registration results with low registration error without being subject to the initial position and direction of the object. In the preprocessing step, the surface points of the object are extracted, and then moment information is computed based on the surface points. Moment information is matched prior to fine registration based on the surface distance, in order to ensure stable registration results even when the initial positions and directions of the objects are very different. Moreover, surface comer sampling algorithm has been used in extracting representative surface points of the image to overcome the limits of the existed random sampling or systematic sampling methods. The proposed method has been applied to brain MRI(Magnetic Resonance Imaging) and PET(Positron Emission Tomography), and its accuracy and stability were verified through registration error ratio and visual inspection of the 2D/3D registration result images.