• Title/Summary/Keyword: MRI Image

Search Result 941, Processing Time 0.027 seconds

A Study on Pathological Pattern Detection using the quasi-Bisymmetry of MRI DWI Brain Image (MRI 확산강조 뇌영상의 유사대칭성을 이용한 병변검출에 관한 연구)

  • Kim, S.H.;Lee, H.W.;Lee, J.W.;Jeong, W.G.;Gang, Ik-Tae;Lee, G.K.
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.4
    • /
    • pp.37-44
    • /
    • 2009
  • Stroke patients are the most in the cause of death among Koreans. Therefore, an accurate diagnosis of stroke is very important. But, it is the only way to diagnose strokes that the doctors see the MRI image and detect the pathological pattern. In this paper, we proposed the new method to detect the pathological pattern of a suspected stroke. We used the quasibi-symmetry of the MRI brain image in our new method. we detected pathological pattern applied the proposed method, and show the result.

  • PDF

Experimental Study of Chemical Shift Artifacts at 1.5T and 3.0T MRI using Gradient Echo Pulse Sequence (GE 펄스시퀀스을 이용한 1.5T와 3.0T MRI의 화학적 이동 인공물의 실험적 연구)

  • Cheol, Kweon Dae
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.531-537
    • /
    • 2016
  • An experimental study was to use the parameter to determine the MRI artifact of chemical shift that occurs in water and fats. Scanning the image according to the encoding parameter and the bandwidth and change in 1.5T and 3.0T MRI to the SNR, we compared the CNR. In the image was confirmed that the occurrence of artefacts in the chemical shift of the water and oil. 3.0T more image artifacts in the 1.5T was confirmed that the relatively reduced. The width of the bandwidth it could be confirmed that according to the honeycombs artifacts decrease. Therefore, in order to reduce the artifacts in the MRI scan of the chemical shift runners weak field strength, is thought to be appropriate to widen the width of the bandwidth.

Application of MRI in dentistry: Radiation free image (치과 임상에서 MRI의 활용)

  • Jeon, Kug Jin
    • The Journal of the Korean dental association
    • /
    • v.57 no.11
    • /
    • pp.700-707
    • /
    • 2019
  • On account of the dentistry mainly deals with hard tissues such as teeth and bones, CBCT and CT are common imaging modality in clinics. Recently, insurance coverage of MRI has been extended to head and neck region. In addition, unlike CBCT or CT, ionizing radiation is not used, the demand for MRI is gradually increasing in dentistry. Even though, many dentists still think that MRI is a difficult diagnostic tool and they are not confident when to use it. Therefore, the objective of this manuscript is to help the dental clinicians to access easily on MRI by introducing the overview, application and precautions of this imaging tool.

  • PDF

Neuroactivation studies using Functional Brain MRI (기능적 자기공명영상을 이용한 뇌활성화 연구)

  • Chung, Kyung-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.1
    • /
    • pp.63-72
    • /
    • 2003
  • Functional MRI (fMRI) provides an indirect mapping of cerebral activity, based on the detection of the local blood flow and oxygenation changes following neuronal activity (Blood Oxygenation Level Dependent). fMRI allows us to study noninvasively the normal and pathological aspects of functional cortical organization. Each fMRI study compares two different states of activity. Echo-Planar Imaging is the technique that makes it possible to study the whole brain at a rapid pace. Activation maps are calculated from a statistical analysis of the local signal changes. fMRI is now becoming an essential tool in the neurofunctional evaluation of normal volunteers and many neurological patients as well as the reference method to image normal or pathologic functional brain organization.

Acquisition and Interpretation Guidelines of Breast Diffusion-Weighted MRI (DW-MRI): Breast Imaging Study Group of Korean Society of Magnetic Resonance in Medicine Recommendations

  • Kang, Bong Joo;Kim, Min Jung;Shin, Hee Jung;Moon, Woo Kyung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.26 no.2
    • /
    • pp.83-95
    • /
    • 2022
  • The purpose of this study was to establish and provide guidelines for the standardized acquisition and interpretation of diffusion-weighted magnetic resonance imaging (DW-MRI) to improve the image quality and reduce the variability of the results interpretation. The standardized protocol includes the use of high-resolution DW-MRI with advanced techniques and post-processing. The aim of the protocol is to increase the effectiveness of the medical image information exchange involved in the construction, activation, and exchange of clinical information for healthcare use. An organized interpretation form could make DW-MRIs' interpretation easier and more familiar. Herein, the authors briefly review the basic principles, optimized image acquisition, standardized interpretation guidelines, false negative and false positive cases of DW-MRI, and provide a standard interpretation form and examples of various cases to help users become more familiar with the DW-MRI.

Improving Image Quality of MRI using Frequency Filter (Frequency Filter를 사용한 MRI 영상 화질의 향상)

  • Kim, Dong-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.309-315
    • /
    • 2009
  • Image reconstruction of Inverse Fourier Transform after Frequency Domain Data is filtered applies to Image signal acquired from MR. There are various kinds of image processing techniques; image preprocessing, image reconstruction, image compression, image restoration image mixture, noise and artifact elimination, and image quality improvement. In this paper, optimum filter applicable to diagnosis in clinic by comparing and analyzing the characteristics of the filter will be explained. Fermi-Dirac filter will improve the image quality better than the previous MR image.

Fast Real-Time Cardiac MRI: a Review of Current Techniques and Future Directions

  • Wang, Xiaoqing;Uecker, Martin;Feng, Li
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.252-265
    • /
    • 2021
  • Cardiac magnetic resonance imaging (MRI) serves as a clinical gold-standard non-invasive imaging technique for the assessment of global and regional cardiac function. Conventional cardiac MRI is limited by the long acquisition time, the need for ECG gating and/or long breathhold, and insufficient spatiotemporal resolution. Real-time cardiac cine MRI refers to high spatiotemporal cardiac imaging using data acquired continuously without synchronization or binning, and therefore of potential interest in overcoming the limitations of conventional cardiac MRI. Novel acquisition and reconstruction techniques must be employed to facilitate real-time cardiac MRI. The goal of this study is to discuss methods that have been developed for real-time cardiac MRI. In particular, we classified existing techniques into two categories based on the use of non-iterative and iterative reconstruction. In addition, we present several research trends in this direction, including deep learning-based image reconstruction and other advanced real-time cardiac MRI strategies that reconstruct images acquired from real-time free-breathing techniques.

Evaluation of the Noise Power Spectrum by Using American College of Radiology Phantom for Magnetic Resonance Imaging (자기공명영상에서 ACR 팬텀을 이용한 잡음전력스펙트럼 평가)

  • Jung-Whan Min;Hoi-Woun Jeong
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.21-28
    • /
    • 2024
  • This study was purpose to quantitative evaluation of comparison of the image intensity uniformity and noise power spectrum (NPS) by using American college of radiology (ACR) phantom for magnetic resonance imaging (MRI). The MRI was used achiva 3.0T MRI and discovery MR 750, 3.0T, the head and neck matrix shim SENSE head coil were 32 channels receive MR coil. The MRI was used parameters of image sequence for ACR standard and general hospital. NPS value of the ACR standard T2 vertical image in GE equipment was 7.65E-06 when the frequency was 1.0 mm-1. And the NPS value of the ACR hospital T1 region of interest (ROI) 9 over all vertical image in Philips equipment was 9E-08 when the frequency was 1.0 mm-1 and the NPS value of the hospital T2 ROI 9 over all vertical image in Philips equipment was 1.06E-07 when the frequency was 1.0 mm-1. NPS was used efficiently by using a general hospital vertical sequence more than the standard vertical sequence method by using the ACR phantom. Furthermore NPS was the quantitative quality assurance (QA) assessment method for noise and image intensity uniformity characteristics was applied mutatis mutandis, and the results values of the physical imaging NPS of the 3.0T MRI and ACR phantom were presented.

Evaluation of Tendency for Characteristics of MRI Brain T2 Weighted Images according to Changing NEX: MRiLab Simulation Study (자기공명영상장치의 뇌 T2 강조 영상에서 여기횟수 변화에 따른 영상 특성의 경향성 평가: MRiLab Simulation 연구)

  • Kim, Nam Young;Kim, Ju Hui;Lim, Jun;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.9-14
    • /
    • 2021
  • Recently, magnetic resonance imaging (MRI), which can acquire images with good contrast without exposure to radiation, has been widely used for diagnosis. However, noise that reduces the accuracy of diagnosis is essentially generated when acquiring the MR images, and by adjusting the parameters, the noise problem can be solved to obtain an image with excellent characteristics. Among the parameters, the number of excitation (NEX) can acquire images with excellent characteristics without additional degradation of image characteristics. In contrast, appropriate NEX setting is required since the scan time increases and motion artifacts may occur. Therefore, in this study, after fixing all MRI parameters through the MRiLab simulation program, we tried to evaluate the tendency of image characteristics according to changing NEX through quantitative evaluation of brain T2 weighted images acquired by adjusting only NEX. To evaluate the noise level and similarity of the acquired image, signal to noise ratio (SNR), contrast to noise ratio (CNR), root mean square error (RMSE) and peak signal to noise ratio (PSNR) were calculated. As a result, both noise level and similarity evaluation factors showed improved values as NEX increased, while the increasing width gradually decreased. In conclusion, we demonstrated that an appropriate NEX setting is important because an excessively large NEX does not affect image characteristics improvement and cause motion artifacts due to a long scan.

Adaptation of Wavelet Algorithm for Obtaining a Human Brain's Function Map (뇌의 기능적 영역 추출을 위한 Wavelet 변환 알고리즘의 적용)

  • 이상민;장두봉;김동희;김광열;이건기;신태민
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.203-206
    • /
    • 2001
  • The fMRI which can express the function of brain as MR image is now being studied. The study on the functional image has usually been performed with the MRI in 4 tesla class in goneral, but if gradient echo imaging method could be used, it might make the most of what it has with the MRI in 1.5 tesla class. However, the lack of adequate image post-processing software prevents it from being used as widely as it could be. For the image post-processing algorithm of the functional image, subtraction method and several statistical methods are used with continuous introduction of new method recently. In this paper, we suggest adaptation of wavelet algorithm for obtaining a more reliable brain function map.

  • PDF