• Title/Summary/Keyword: MRI Image

Search Result 941, Processing Time 0.031 seconds

Minimum-Power Design of Actively-Shielded Transverse Gradient Coils for MRI (MRI용 차폐된 X,Y-경사자계코일의 최소전력설계)

  • Lee, D.R.;Kim, S.K.;Yang, Y.J.;Lee, H.K.;Ahn, C.B.;Oh, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.307-309
    • /
    • 1996
  • A new design scheme of actively-shielded x,y-gradient coils for Magnetic Resonance Imaging(MRI) is proposed. An actively-shielded x-gradient coil has been designed as an example and the results are presented. In MRI, gradient coils are needed for spatial selection and position coding to obtain the position information of the NMR signal. They are usually switched on and off during imaging and the eddy current induced by the current switching usually degrades the final image quality To reduce or remove this kind of problems, the active shielding has been proposed few years ago. In this paper, a new design scheme for actively-shielded x,y-gradient coils, namely, a minimum-power design scheme using current-loop elements, has been proposed. Its utility in designing MRI gradient coils has been shown by using simulation. The design scheme seems to be useful for actively-shielded transverse gradient coils, even of non-cylindrical or of arbitrary-selected shapes.

  • PDF

Characteristics of Magnetic Resonance-Based Attenuation Correction Map on Phantom Study in Positron Emission Tomography/Magnetic Resonance Imaging System

  • Hong, Cheolpyo
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.189-193
    • /
    • 2020
  • An MR-based attenuation correction (MRAC) map plays an important role in quantitative positron emission tomography (PET) image evaluation in PET/magnetic resonance imaging (MRI) systems. However, the MRAC map is affected by the magnetic field inhomogeneity of MRIs. This study aims to evaluate the characteristics of MRAC maps of physical phantoms on PET/MRI images. Phantom measurements were performed using the Siemens Biograph mMR. The modular type physical phantoms that provide assembly versatility for phantom construction were scanned in a four-channel Body Matrix coil. The MRAC map was generated using the two-point Dixon-based segmentation method for whole-body imaging. The modular phantoms were scanned in compact and non-compact assembly configurations. In addition, the phantoms were scanned repeatedly to generate MRAC maps. The acquired MRAC maps show differently assigned values for void areas. An incorrect assignment of a void area was shown on a locally compact space between phantoms. The assigned MRAC values were distorted using a wide field-of-view (FOV). The MRAC values also differed after repeated scans. However, the erroneous MRAC values appeared outside of phantom, except for a large FOV. The MRAC map of the phantom was affected by phantom configuration and the number of scans. A quantitative study using a phantom in a PET/MRI system should be performed after evaluation of the MRAC map characteristics.

Algorithm for Classifiation of Alzheimer's Dementia based on MRI Image (MRI 이미지 기반의 알츠하이머 치매분류 알고리즘)

  • Lee, Jae-kyung;Seo, Jin-beom;Cho, Young-bok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.97-99
    • /
    • 2021
  • As the aging society continues in recent years, interest in dementia is increasing. Among them, Alzheimer's disease is a degenerative brain disease that accounts for the largest percentage of all dementia patients, with the medical community currently not offering clear prevention and treatment for Alzheimer's disease, and the importance of early treatment and early prevention is emphasized. In this paper, we intend to find the most efficient activation function by combining various activation functions centering on convolutional neural networks using MRI datasets of normal people and patients with Alzheimer's disease. In addition, it is intended to be used as a dementia classification modeling suitable for the medical field in the future through Alzheimer's dementia classification modeling.

  • PDF

Pictorial Review of Mediastinal Masses with an Emphasis on Magnetic Resonance Imaging

  • Jin Wang Park;Won Gi Jeong;Jong Eun, Lee;Hyo-jae Lee;So Yeon Ki;Byung Chan Lee;Hyoung Ook Kim;Seul Kee Kim;Suk Hee Heo;Hyo Soon Lim;Sang Soo Shin;Woong Yoon;Yong Yeon Jeong;Yun-Hyeon Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.1
    • /
    • pp.139-154
    • /
    • 2021
  • Magnetic resonance imaging (MRI) has become a crucial tool for evaluating mediastinal masses considering that several lesions that appear indeterminate on computed tomography and radiography can be differentiated on MRI. Using a three-compartment model to localize the mass and employing a basic knowledge of MRI, radiologists can easily diagnose mediastinal masses. Here, we review the use of MRI in evaluating mediastinal masses and present the images of various mediastinal masses categorized using the International Thymic Malignancy Interest Group's three-compartment classification system. These masses include thymic hyperplasia, thymic cyst, pericardial cyst, thymoma, mediastinal hemangioma, lymphoma, mature teratoma, bronchogenic cyst, esophageal duplication cyst, mediastinal thyroid carcinoma originating from ectopic thyroid tissue, mediastinal liposarcoma, mediastinal pancreatic pseudocyst, neurogenic tumor, meningocele, and plasmacytoma.

A fMRI study on the cerebral activity induced by Electro-acupuncture on Zusanli(St36) (족삼리(足三里)(St36)의 전침자극(電鍼刺戟)이 fMRI상 뇌활성(腦活性) 변화(變化)에 미치는 영향(影響))

  • Kim, Young-il;Kim, Young-hwa;Lim, Yun-kyoung;Lee, Hyen;Lee, Byung-ryul;Kim, Yeon-jin
    • Journal of Acupuncture Research
    • /
    • v.20 no.5
    • /
    • pp.133-150
    • /
    • 2003
  • Objective: Recently. many studies have showed the evidences of the effect of the Electro-acupuncture treatment through scientific. Methods : One of these methods is functional MRI. We performed electro-acupuncture on Zusanli(St36) and observed the change of brain activation using fMRI. Zusanli(St36) is located on the lateral side of the lower leg. 3 cun(寸) inferior to the Patella of the lower border. Theoretically and clinically. this point has been considered very important for gynecological disorders. spleen and stomach disorders. and psychological disorders. To see the effects of electro-acupuncture stimulation on Zusanli(St36). the experiment was carried out on twelve healthy volunteers. using the gradient echo sequence with the 3.0T whole-body fMRI system(ISOL). After the needle insertion on right Zusanli(St36). 2 Hz of electric stimulation was given for 30 seconds. repeated five times. with 30 seconds' intervals. The Image analysis including motion correction. talairach transformation, and smoothing was done with SPM99. Results ad conclusion : The electro-acupuncture stimulation on Zusanli(St36) activates Brodmann Area 6, 13, 2, 19, 21, 22, 39, 40, 38, 3which indicates the pathways of the electro-acupuncture stimulation on Zusanli(St36) and the possibility of the relationship of the electro-acupuncture stimulation on Zusanli(St36) with autonomic nervous system, internal organic system.

  • PDF

A fMRI study on the cerebral activity induced by Electro-acupuncture on Taichong(Liv3) (태충(太衝)(Liv3)의 전침자극(電鍼刺戟)이 fMRI상 뇌활성(腦活性) 변화(變化)에 미치는 영향(影響))

  • Ha, Chi-hong;Lee, Hyun;Lim, Yun-kyoung;Hong, Kwon-eui;Lee, Byung-ryul;Kim, Yeon-jin
    • Journal of Acupuncture Research
    • /
    • v.20 no.5
    • /
    • pp.187-207
    • /
    • 2003
  • Objective: Recently, many studies have showed the evidences of the effect of the acupuncture treatment through scientific methods. One of these methods is functional MRI. We performed electro-acupuncture on Liv3 and observed the change of brain activation using fMRI. Methods: To see the effect of electro-acupuncture stimulation on Liv3. the experiment was carried out on 12 healthy volunteers. using the gradient echo sequence with the 3.0T whole-body MRI system(ISOL). After the needle insertion on right Liv3. 2 Hz of electric stimulation was given for 30 seconds. repeated five times. with 30 seconds' intervals. The Image analysis including motion correction, talairach transformation. and smoothing was done with SPM99. Results : 1. Group averaged brain activation induced by bilateral electro-acupuncture stimulation on Liv3 activates Brodman Area 6, 13, 18, 19, 22, 31, 39, 44, 2. Group averaged brain deactivation induced by bilateral Electro-acupuncture stimulation on Liv3 activates Brodman Area 4, 6, 9, 19, 36, 37, 39. 3. Group averaged brain activation induced by unilateral(right side) electro-acupuncture stimulation on Liv3 activates Brodman Area 2, 3, 6, 9, 10, 22, 40, 42, 43. 4. Group averaged brain deactivation induced by unilateral(right side) electro-acupuncture stimulation on Liv3 activates Brodman Area 6, 18, 19, 28, 30, 31, 35, 37. 5. Brain region activated by motor stimulation activates Brodman Area 4, 6, 13, 19, 42.

  • PDF

A fMRI study on the cerebral activity induced by Electro-acupuncture on Sp9(Yinlingquan) (음릉천(陰陵泉)(Sp9)의 전침자극(電鍼刺戟)이 functional MRI상 뇌활성(腦活性) 변화(變化)에 미치는 영향(影響))

  • Kim, Jeong-ho;Lee, Hyun;Lim, Yun-kyoung;Hong, Kwon-eui;Lee, Byung-ryul;Kim, Yeon-jin
    • Journal of Acupuncture Research
    • /
    • v.20 no.4
    • /
    • pp.114-133
    • /
    • 2003
  • Objective : The meridian theory in oriental medicine explains that Sp9(Yinlingquan) has been considered very important for gynecological disorders, spleen and stomach disorders, and water metabolic disorders. Functional MRI is the best method of showing the evidences of the effect of the Electro-acupuncture treatment through scientific methods. On this supposition, Electro-acupuncture stimulation on Sp9(Yinlingquan) was carried out on six healthy volunteers, using the gradient echo sequence with the 3.0T whole-body MRI system(ISOL). Methods : Electro-acupuncture stimulation on Sp9(Yinlingquan), the experiment was carried out on six healthy volunteers, using the gradient echo sequence with the 3.0T whole-body MRI system(ISOL). After the needle insertion on right Sp9(Yinlingquan), 2Hz of electric stimulation was given for 30 seconds, repeated five times, with 30 seconds' intervals. The Image analysis including motion correction, talairach transformation, and smoothing was done using SPM99. Results : The electro-acupuncture stimulation on Sp9(Yinlingquan) activates Brodmann Area 13, 19, 22, 39, 40, 47 which may be the central pathways of the electro-acupuncture stimulation on Sp9(Yinlingquan). We also hypothesize that those brain areas may be directly or indirectly related with the mechanism of the effect of electro-acupuncture stimulation on Sp9(Yinlingquan).

  • PDF

Accelerated Resting-State Functional Magnetic Resonance Imaging Using Multiband Echo-Planar Imaging with Controlled Aliasing

  • Seo, Hyung Suk;Jang, Kyung Eun;Wang, Dingxin;Kim, In Seong;Chang, Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.4
    • /
    • pp.223-232
    • /
    • 2017
  • Purpose: To report the use of multiband accelerated echo-planar imaging (EPI) for resting-state functional MRI (rs-fMRI) to achieve rapid high temporal resolution at 3T compared to conventional EPI. Materials and Methods: rs-fMRI data were acquired from 20 healthy right-handed volunteers by using three methods: conventional single-band gradient-echo EPI acquisition (Data 1), multiband gradient-echo EPI acquisition with 240 volumes (Data 2) and 480 volumes (Data 3). Temporal signal-to-noise ratio (tSNR) maps were obtained by dividing the mean of the time course of each voxel by its temporal standard deviation. The resting-state sensorimotor network (SMN) and default mode network (DMN) were estimated using independent component analysis (ICA) and a seed-based method. One-way analysis of variance (ANOVA) was performed between the tSNR map, SMN, and DMN from the three data sets for between-group analysis. P < 0.05 with a family-wise error (FWE) correction for multiple comparisons was considered statistically significant. Results: One-way ANOVA and post-hoc two-sample t-tests showed that the tSNR was higher in Data 1 than Data 2 and 3 in white matter structures such as the striatum and medial and superior longitudinal fasciculus. One-way ANOVA revealed no differences in SMN or DMN across the three data sets. Conclusion: Within the adapted metrics estimated under specific imaging conditions employed in this study, multiband accelerated EPI, which substantially reduced scan times, provides the same quality image of functional connectivity as rs-fMRI by using conventional EPI at 3T. Under employed imaging conditions, this technique shows strong potential for clinical acceptance and translation of rs-fMRI protocols with potential advantages in spatial and/or temporal resolution. However, further study is warranted to evaluate whether the current findings can be generalized in diverse settings.

Effects of through the intercom during MRI Scans on Patient Anxiety and Intentional Contact (MRI 검사 시 방송을 통한 의도적 접촉이 환자 불안에 미치는 영향)

  • Kim, Sang-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.1
    • /
    • pp.294-299
    • /
    • 2013
  • This study has investigated the effect of intentional contact through the intercom during MRI scans on the decrease of anxiety in patients. The results obtained through the test group and control group are as follows. 1. The homogeneity of the anxiety score before the scan between the two groups was not acknowledged, hence a significant result could not be deduced. 2. Intentional contact through the intercom displayed decreasing results rational discomfort (t=-2.214, p=.031). 3. Intentional contact through the intercom displayed decreasing results of (t=-3.722, p=.000), and fear (t=-2.74, p=.009). 4. Intentional contact through the intercom displayed decreasing results of heart rate (t=-4.180, p=.000). In conclusion, the attempt to perform MRI scans with intentional contact through the intercom did not display significant effect on the blood pressure of the subject after the scan, however, displayed a decrease in objective and rational discomfort, as well as the heart rate, another vital sign. Accordingly, it is judged that intentional contact through the intercom can be used as an effective substitutive treatment method in patient care and test, as it relieves psychological tension in the patient and allows the patient to feel stability.

fMRI study on the cerebral activity induced by Electro-acupuncture on Sanyinjiao(Sp6) (삼음교(三陰交)(Sp6) 전침자극(電針刺戟)이 fMRI상 뇌활성변화(腦活性變化)에 미치는 영향(影響))

  • Hong, Kwon-eui;Lee, Byung-ryul;Lee, Hyun;Yim, Yun-kyoung;Kim, Yun-jin
    • Journal of Acupuncture Research
    • /
    • v.20 no.3
    • /
    • pp.86-103
    • /
    • 2003
  • Objective : Recently, many studies have showed the evidences of the effect of the acupunture treatment through scientific methods. One of these methods is functional MRI. We performed electro-acupunture on Sp6 and observed the changes of brain activation using fMRI. Methods : To see the effect of electro-acupunture stimulation on Sp6, the experiment was carried out on 12 healthy volunteers, using the gradient echo sequence with the 3.0T whole-body MRI system(ISOL). After the needle insertion on right Sp6, 2Hz of electric stimulation was given for 30 seconds, repeated five times, with 30 seconds' intervals. The Image analysis including motion correction, talairach transformation, and smoothing was done with SPM99. Results : 1. Group averaged brain activation induced by bilateral eletro-acupunture stimulation on Sp6 activates Brodman Area 3, 7, 13. 2. Group averaged brain deactivation induced by bilateral eletro-acupunture stimulation on Sp6 activates Brodman Area 6, 38, 47. 3. Group averaged brain activation induced by unilateral(right side) eletro-acupunture stimulation on Sp6 activates Brodman Area 5, 6, 13, 17, 18, 19, 31, 38, 40 ptoms, back pain(32.5%) was the 4. Group averaged brain deactivation induced by unilateral(right side) eletro-acupunture stimulation on Sp6 activates Brodman Area 3, 4, 18, 21, 36, 38, 39. 5. Brain region activated by motor stimulation activates Brodman Area 3, 4, 6, 18, 19.

  • PDF