• Title/Summary/Keyword: MRI Image

Search Result 941, Processing Time 0.032 seconds

Quantitative analysis of lumbar multifidus atrophy with low back pain patients using Magnetic Resonance Image (자기공명영상(MRI)을 통한 요통환자의 다열근 위축에 대한 정량적 분석)

  • Yang, Dae-Jung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.4
    • /
    • pp.615-621
    • /
    • 2010
  • Purpose : The purpose of this study was to compare chronic LBP patients and asymptomatic subjects on measures of multifidus size (cross-sectional area;CSA, thickness) and symmetry (proportional difference of relatively larger side to smaller side). Methods : Data were obtained from 12 asymptomatic subjects without a prior history of LBP (8 females, 4 males), and a retrospective audit was undertaken of records from 12 chronic low back pain patients (8 females, 4 males). CSA and Thickness of the lumbar multifidus muscles was measured from axial T1-weighted magnetic resonance images(MRI). Results : The results of the analysis showed that chronic LBP patients had significantly smaller multifidus CSA and thickness than asymptomatic subjects at L4-5 vertebral levels(p<.05). The asymmetry between sides was seen at L4- L5 vertebral level in patients with chronic low back pain presentations(p<.05). Conclusions : MRI provided a quantitative measure of change between asymptomatic subjects and chronic low back pain patients of multifidus muscle. MRI identified significant differences in cross-sectional area and thickness and helps to evaluate clinically and plan the treatment modalities of LBP.

Improved Perfusion Contrast and Reliability in MR Perfusion Images Using A Novel Arterial Spin Labeling

  • Jahng, Geon-Ho;Xioaping Zhu;Gerald Matson;Weiner, Michael-W;Norbert Schuff
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.341-344
    • /
    • 2002
  • Neurodegenerative disorders, like Alzheimer's disease, are often accompanied by reduced brain perfusion (cerebral blood flow). Using the intrinsic magnetic properties of water, arterial spin labeling magnetic resonance imaging (ASLMRI) can map brain perfusion without injection of radioactive tracers or contrast agents. However, accuracy in measuring perfusion with ASL-MRI can be limited because of contributions to the signal from stationary spins and because of signal modulations due to transient magnetic field effects. The goal was to optimize ASL-MRI for perfusion measurements in the aging human brain, including brains with Alzheimer's disease. A new ASL-MRI sequence was designed and evaluated on phantom and humans. Image texture analysis was performed to test quantitatively improvements. Compared to other ASL-MRI methods, the newly designed sequence provided improved signal to noise ratio improved signal uniformity across slices, and thus, increased measurement reliability. This new ASL-MRI sequence should therefore provide improved measurements of regional changes of brain perfusion in normal aging and neurodegenerative disorders.

  • PDF

Cerebral Infarction Model in Rat on Magnetic Resonance Imaging (흰 쥐의 뇌경색 병변에 대한 자기공명영상)

  • Jung, Ji-Sung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.55-58
    • /
    • 2011
  • It is important to study using experimental animals for research about stroke. Magnetic Resonance Imaging(MRI) is avaluable diagnosticmethods for stroke diagnosis. The purpose of this research is to know the Magnetic Resonance Imaging(MRI) and histopathological characteristics findings after induction of photothrombotic cerebral infarction in rat brain. Male Sprague-Dawley rats were anesthetized, Rose Bengal dye(20 mg/kg) was intravenously injected. The right sensonrimotor cortex of rat brain was exposed to cold light of 7 mm diameter at a position of 1 mm anterior and 3.5 mm lateral to bregma for 20 min. The post-infarction effects were monitored by T1 weighted and T2 weighted images of brain MRI. Histopathological changes were observed after Hematoxylin & Eosin staining. The lesion appeared clearly high signal intensity area on T2 weighted images(the major axis $7.04{\pm}0.11$ mm, the minor axis $3.08{\pm}0.04$ mm) and also H&E staining was same result. In conclusion, MRI was avaluable diagnostic methods for diagnosis and serial changes of stroke.

  • PDF

The Organ projection system using holographic lens (홀로렌즈를 이용한 장기 투영 시스템)

  • Kim, dong young;Kim, dong hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.83-85
    • /
    • 2017
  • Generally, the current organ projection systems are the MRI and the CT. The MRI and the CT, (MRI) allow the surgeon to see the internal organs without incising the human body. However, since the images generated by the machines are 2D, it is difficult for doctors to observe the internal organs in three dimension. In this paper, we develop the augmented projection system for internal organs by using the augmented reality technology. The developed system shows the internal organs of the body using a holographic lens as a stereoscopic image and allows for doctors to examine the internal organs in detail.

  • PDF

Effect of Antibacterial Film Containing Silver Ions on MRI (은(Ag)이온이 함유된 항균필름이 MRI에 미치는 영향)

  • Shin, Byeong Geun;Kim, Seong Hu;Ahn, Seong Min
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.219-224
    • /
    • 2021
  • The purpose of these experiments is often to scan infected patients with MRI. Therefore, it is to investigate whether the antibacterial film containing silver ions, which is a non-magnetic substance, affects magnetic resonance imaging. In this experiment, the ACR phantom was used, not the patient. The ACR phantom was wrapped in an antibacterial film and the SNR, CNR, sagittal localization image, and geometrical accuracy were compared before and after. The experiment was performed 10 times and the averaged values were compared. There were no significant differences in the results of all experiments. The FDA recommends removing metal and antibacterial film masks during MRI scans. The reason is that there was one case of injury with facial burns. When I touched the antibacterial film to check the fever during the 2 hour experiment, I did not feel any particular fever. In light of the experimental results, it would be helpful to use an antibacterial film when testing an infected patient. The reason is that there isn't a difference before and after the experiment of SNR, CNR, and sagittal localization images.

MR-Guided Targeted Prostate Biopsy from Radiologists' Perspective (영상의학과 의사의 시각에서 본 자기공명영상 기반 전립선 표적 생검)

  • So-Yeon Kim;Kye Jin Park
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1220-1232
    • /
    • 2023
  • The prostate cancer diagnosis has traditionally been based on a systematic biopsy method in which tissue samples are randomly obtained from the prostate 10-12 sites. However, there are concerns as the method can fail to diagnose all prostate cancers or lead to over-detection of clinically insignificant cancers. MRI-guided prostate targeted biopsy has been proposed to address these shortcomings. This method involves identifying suspicious lesions using MRI and performing targeted biopsies under ultrasound or MRI guidance. We review the methods of MRI-based targeted biopsy and discuss recent guidelines and trends in prostate cancer diagnosis.

RECEMT DEVELOPMENTS IN REAL-TIME MRI

  • Riederer, Stephen J.
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.67-72
    • /
    • 2002
  • Real-time techniques are motivated by a number of factors including the potential for direct acquisition of diagnostic quality images, facilitation of patient-specific imaging parameters, and reduced examination time. Real-time MRI includes not only a rapid pulse sequence but also high speed image reconstruction and easy interactivity. The frame rate of the real-time technique used should be matched to the physiological timeframes under study. Principal applications thusfar have been in localization, fluoroscopic triggering, guidance of other processes, and potentially in the generation of diagnostic images of moving structures.

  • PDF

Changes on MRI(Magnetic Resonance Imaging) in Cervical Disc Herniations Treated with Oriental Medical Therapy (한의학적 치료법으로 호전된 경추 추간판 탈출증 환자에서의 영상의학적 변화)

  • Kim, Ki-Yuk;Kim, Wu-Young;Han, Sang-Yup;Lee, Hyun-Jong;Kim, Ki-Ju;Jeong, Da-Un;Moon, Tae-Woong;Kim, Chang-Youn
    • Journal of Acupuncture Research
    • /
    • v.26 no.4
    • /
    • pp.71-77
    • /
    • 2009
  • Objectives : The aim of this study is to investigate radiological changes in cervical disc herniation after oriental medical treatment. Methods : 9 patient diagnosed as cervical disc herniation by MRI were treated with oriental medical treatment and underwent a follow up MRI study. Results & Conclusions : Comparison of initial MRI with follow-up MRI showed that 2 of the herniations dimensions decreased between 1% and 25%, 1 decreased between 26% and 50%, 5 decreased between 50% and 75%. The mean disc herniation dimensions decrease was 40% in 9 patients. Comparison of initial MRI with follow-up MRI showed that 4 of the herniations diameter decreased between 1% and 25%, 2 decreased between 26% and 50%, 3 decreased between 50% and 75%. The mean disc herniation diameter decrease was 36% in 9 patients.

  • PDF

A Case Study on the MRI Profitability of a General Hospital (한 종합병원의 MRI 채산성 사례 연구)

  • Kang, Chang-Yeol;Song, Sung-Ho;Lim, Kyeong-Tae
    • The Korean Journal of Health Service Management
    • /
    • v.4 no.1
    • /
    • pp.145-156
    • /
    • 2010
  • The purpose of this study is one of high price medical equipment wished to grasp propriety factor about the MRI introduction, analyzing payability through cost accounting into compensation. It was investigated from January 1 to December 31, 2007 about the MRI of a General Hospital. Expectation availability was 23.2 cases, but actual availability did achievement more than 196.1% with 45.5 items. It is estimated that there are a lot of occurrence cases because great reasons that actual availability increases more than expectation availability is excellent resolving power than a CT, and is device that prefer to reason back that radiation damage is less in person body. The followings show the main results of this study. 1. The MRI was construed in order of cost accounting, wave and personnel expenses 45.4%, administrative expenses 53.0%, and material costs 1.6%. 2. According to CVP (Cost-volume-profit) analysis, BEP (Break Even Point) profit is 173,931,428 won for 11 months, and break even usage number of items are 37.5 cases, and separation usage number of items were confirmed by 1.4 cases. Therefore, was construed that can achieve BEP within 11 months though usage number of items keeps 1.4 items day to create the MRI's hospital operation profit. 3. Estimated limit profitability appears high by 96.7%, exceed fixed charges even if when is non-benefit and when it is benefit consider variable, is judged that the MRI's addition induction helps in hospital management enhancing earning rates.

An effectiveness of multitransmit parallel technique on scan time reduction in hip joint MRI (고관절 자기공명영상 검사 시 multitransmit 기법의 적용에 따른 검사시간 단축의 유용성)

  • Choi, Kwan-Woo;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.103-108
    • /
    • 2016
  • This study examined the effectiveness of the multitransmit parallel technique on the MRI scan time reduction by removing the dielectric effect. The T1 and T2 weighted images of the patients' hip joint were acquired with and without a multitransmit technique. The ROIs were located in the head of femur and iliopsoas muscle. The SNR, CNR and scan time were measured and compared. There was no difference in the images with and without multitransmit. In contrast, the acquisition time was decreased by 42.8% in T1WI and 49.7% in T2WI. In conclusion, this study demonstrated that significant scan time reductions can be accomplished without any differences in the image quality in hip joint MRI by applying the multitransmit parallel technique. Furthermore, the multitranstmit technique is useful in other body parts to resolve the long scan time of an MRI examination.