• Title/Summary/Keyword: MRI 영상

Search Result 1,880, Processing Time 0.028 seconds

Nonlinearity in the Somatosensory Cortex Response to Vibrotactile Stimulator in fMRI (기능성 자기공명영상에서 진동자극에 대한 감각피질의 비선형성)

  • Lee, Hyun-Sook
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.159-166
    • /
    • 2006
  • The nonlinearity of hemodynamic response in the somatosensory cortex was investigated with vibrotactile stimulation. The stimuli consisted of a train of 25 Hz, each tasting five different duration periods, 2 s, 4 s, 8 s 12 s, or 16 s with 20 sec periods of no vibration in a pseudo-random order. In order to understand the linearity on the change of stimulus duration for somatosensory cortex, two different tests- checking the linearity of system and finding the impulse response function from gamma-variate function were applied to analyze the hemodynamic response functions. They have produced nearly same results. The BOLD response in the somatosensory cortex Is nonlinear for stimuli of less than 8 seconds, but nearly linear for stimuli greater than 8 seconds. The amplitude, area, TTP, and FWHM as functions of the stimulus duration were calculated and showed a significant downward trend with Increasing stimulus duration for the amplitude and the area. It supports the ranges of nonlinearity are less than 8 seconds.

  • PDF

Comparative assessment of a 1.5T endorectal coil and a 3.0T phased-array coil available for prostate MRI (전립선 MRI에서 사용하는 1.5T 경직장 코일과 3.0T 위상 배열 코일의 성능 비교 평가)

  • Cho, Jae-Hwan
    • Journal of Digital Contents Society
    • /
    • v.11 no.3
    • /
    • pp.283-290
    • /
    • 2010
  • The effectiveness of 3.0T phase array coil images was tested by comparing signal-to-noise ratios for the same coil images relative to 1.5T endorectal coil images. Signal intensities were measured in the three regions of prostate, central and peripheral (right and left) after 40 patients with prostate cancer were imaged during the period between Jan. 2008 and Oct. 2009 with T2 W, T1 W, and DW images obtained respectively using endorectal coil on a 1.5T MR scanner and phase array coil on a 3.0T MR scanner. For quantitative analysis, comparisons of average SNRs for the same ROIs were made between groups scanned with a 1.5T and a 3.0T MR scanner. The signal-to-noise ratios were shown to increase more sharply when using a phase array coil at a 3.0T MR scanner compared to using an endorectal coil at a 1.5T MR scanner.

Neural Correlates of Faux Pas Detection: An fMRI Study (헛디딤 탐지의 신경 상관: 기능적 자기공명 영상 연구)

  • Park, Min;Lee, Seung-Bok;Yoon, Hyo-Woon;Ghim, Hei-Rhee
    • Korean Journal of Cognitive Science
    • /
    • v.21 no.1
    • /
    • pp.77-93
    • /
    • 2010
  • The aim of this study was to identify neural correlates underlying the detection of faux pas, a test of theory of mind (ToM), in Korean healthy adults. Using functional magnetic resonance imaging, we compared the brain activities associated with faux pas stories and the activities associated with control stories. Faux pas stories compared with the control stories produced activations bilaterally in the superior frontal gyrus (BA 9) and in the precuneus (BA 7). The left medial frontal gyrus (BA 9), the left superior temporal gyrus (BA 38), the left inferior temporal gyrus (BA 20) and the right inferior parietal lobule (BA 40), the right postcentral gyrus (BA 1), the right lingual gyrus (BA 18), the right transverse temporal gyrus (BA 41) were also activated. The orbitofrontal cortex and the amygdala were not found to be involved in the detection of faux pas. This result suggests that brain activations associated with ToM are dependent on the type of mental state drawn by the task.

  • PDF

MR Images of Infarction of Wandering Spleen Associated with Intestinal Non-rotation (장 회전 이상과 함께 발생한 부유비장 경색의 자기공명영상에서의 소견: 증례 보고)

  • Kim, Eugene;Kim, Mi Young;Kim, Yeo Ju;Kim, Youn Jeong;Kim, Woo Chul;Suh, Chang Hae;Choi, Suk Jin;Cho, Jae Sung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.253-257
    • /
    • 2014
  • Wandering spleen is a rare clinical condition caused by lax splenic suspensory ligaments. The laxity of ligaments causes torsion of splenic vascular pedicle. CT scan of a 7-year-old girl with abdominal pain showed a non-enhancing lobular mass in lower abdomen. Small bowel loops were located at the right-sided abdomen and colonic loops at the left-sided abdomen. MRI scan showed non-enhancing heterogeneous mass with twisted vascular pedicle. To our knowledge, only a few cases have been reported about wandering spleen diagnosed on MRI.

A Case of Tuberculous Meningoencephalitis Presenting as Prominent Psychotic Features (현저한 정신증상으로 발현된 결핵성 뇌수막뇌염 1예)

  • Yu, Hyun-Jung;Oh, Jee-Young;Kim, Jee-Hyun;Kim, Jung-Eun;Park, Kee-Duk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.6
    • /
    • pp.603-608
    • /
    • 2001
  • Intracranial vasculitis is a rare and disastrous complication of tuberculous meningitis if not treated properly. Focal neurologic deficits according to the vessels involved are common manifestation. Here, we report a 29-year-old man who suffered abrupt, bizarre behavioral changes caused by vasculitis complicating tuberculous meningoencephalitis. The diagnosis of tuberculous meningitis is based upon both the CSF findings and a chest X-ray. His systemic symptoms disappeared by after being administered antituberculous medication but various psychotic features such as hypersomnia, hyperphagia and aggressive behavior continued. A brain MRI showed multiple small parenchymal tuberculous nodules, and the brain MR angiography revealed a narrowing of the proximal middle cerebral arteries and a reduced visualization of the cerebral vessels, suggesting widespread vasculitis. Intravenous dexamethasone successfully ameliorated his behavioral changes. In addition both the follow up brain MRI and angiography showed a normalization of the previous findings.

  • PDF

The Evaluation about the Information Fidelity in the External Image Information Input - Using DICOM Validation Tool - (외부영상정보 입력 시 DICOM정보 충실성에 대한 평가 - DICOM Validation Tool 이용 -)

  • Lee, Song-Woo;Lee, Ho-Yeon;Do, Ji-Hoon;Jang, Hye-Won
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.33-38
    • /
    • 2011
  • Now a days, there's many change over for PACS among the most of hospital and it standard for DICOM 3.0. These kind of using of DICOM 3.0 improves increasing of medical imaging exchange and service for patient. However, there's some problems of compatibility caused during carry out CD and DVD from hospital. For this reason, this thesis analyzed patients image targeting those storages requested to hospitals in Seoul by using Validation Toolkit which is recommended from KFDA. The analyze type is like this. Make 100 data, total 500, each of MRI CT Plain x-ray Ultrasound PET-CT images and analyzed type of error occurred and loyalty of information. If express percentage of error occurred statistically, we can get a result as follows MRI 5%, Plain x-ray 11%, CT 18%, US 25%, PET-CT 30%. The reson why percentage of error occurred in PET-CT is because of imperfective support and we could notice that we weren't devoted to information. Even though, PET-CT showed highest percentage of error occurred, currently DICOM data improved a lot compare to past. Moreover, it should be devoted to rule of IHE TOOL or DICOM. In conclusion, we can help radiographer to analyze information of image by providing clues for solving primary problem and further more, each of PACS company or equipment company can enhance fidelity for following standard of image information through realizing the actual problem during transfer of image information.

  • PDF

Charcot Spinal Arthropathy with Extensive Vertebral Body Destruction and Cerebrospinal Fluid Collection: A Case Report Mimicking Infective Spondylitis (척추체의 광범위한 파괴와 뇌척수액 축적이 동반된 샤르코 척추 관절병증: 감염성 척추염과 유사한 소견을 보이는 증례보고)

  • Cho, Kyu-Jung;Kim, Yeo-Ju;Kim, Young-Tae;Youn, Yung-Hun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.4
    • /
    • pp.348-353
    • /
    • 2020
  • A 68-year-old man presented with a bed sore with pus discharge on lower back. Radiographs showed extensive destruction of the L4 vertebral body. Magnetic resonance imaging (MRI) showed fluid collection with an enhanced wall at the defect of the L4 vertebral body extending into both psoas muscles. The primary diagnosis was neuropathic spondylopathy, but infective spondylitis was not ruled out. Initially, he was treated with antibiotics for two weeks. A follow-up MRI showed no improvement of the abscess, so surgical exploration was done. Charcot spinal arthropathy resulted in extensive vertebral body destruction that may be similar to infectious spondylitis, particularly in the case with fluid accumulation due to rupture of dura.

Salt and Pepper Noise Removal Algorithm based on Euclidean Distance Weight (유클리드 거리 가중치를 기반한 Salt and Pepper 잡음 제거 알고리즘)

  • Chung, Young-Su;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.11
    • /
    • pp.1637-1643
    • /
    • 2022
  • In recent years, the demand for image-processing technology in digital marketing has increased due to the expansion and diversification of the digital market, such as video, security, and machine intelligence. Noise-processing is essential for image-correction and reconstruction, especially in the case of sensitive noises, such as in CT, MRI, X-ray, and scanners. The two main salt and pepper noises have been actively studied, but the details and edges are still unsatisfactory and tend to blur when there is a lot of noise. Therefore, this paper proposes an algorithm that applies a weight-based Euclidean distance equation to the partial mask and uses only the non-noisy pixels that are the most similar to the original as effective pixels. The proposed algorithm determines the type of filter based on the state of the internal pixels of the designed partial mask and the degree of mask deterioration, which results in superior noise cancellation even in highly damaged environments.

개인용 컴퓨터를 이용한 뇌 합성영상에 대한 재구성

  • Min, Hyeong-Gi;Nam, Sang-Hui
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.3 no.1
    • /
    • pp.110-118
    • /
    • 1997
  • Recently, to make a diagnosis of the patient different X-Ray examinations are used. To name a few, Computed Tomography(CT). Magnetic Resonance Image(MRI) Single Photon Emission Computed Tomography(SPET) and Positron Emission Tomography(PET). But diagnosticians face difficulties sometimes when they make a diagnosis with images from those examinations. One of the problem is whether the Lesions of the patient is captured in the image correctly. Another one is whether the images are taken with same angle. in this paper, a study 9 on the method to obtain the hybrid image from the different images to different examinations. The procedure done in this paper is described as future study. Although small errors in position between images would occurred, this method more useful as it does not make patients in convenient. To reconstruct a image, some images are scanned by scanner and stored to personal computer for further image processing with Aldus photostyler program. The method to generate a sharpened image are also described.

  • PDF

Pre-evaluation of Non-alcoholic Fatty Liver Disease Model Using Micro-MRI: For Big Data Application (비알콜성 간 질환 동물모델 영상 빅 데이터 구축을 위한 영상데이터 수집 및 사전평가)

  • Lee, Gi-Taek;Jun, Hong Young;Kim, Tae-Hoon;Jang, Mi Yeon;Kim, Dae Won;Yoon, Kwon-Ha
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.04a
    • /
    • pp.982-983
    • /
    • 2017
  • 본 연구는 최근 문제가 되고 있는 비알콜성 간 질환에 대한 빅 데이터의 사전 데이터를 만들기 위해 마우스에서 고지방 식이와 Streptozotocin ((STZ)로 모델을 제작하였고, 당뇨와 비만 정도를 측정하여 질환발생 정도를 확인하였다. 또한, MR영상의 지속적인 촬용으로 질환발생과정에 대해 3D분석 소프트웨어로 평가되었다.