• Title/Summary/Keyword: MRI 영상

Search Result 1,880, Processing Time 0.034 seconds

Noise Level Evaluation According to Slice Thickness Change in Magnetic Resonance T2 Weighted Image of Multiple Sclerosis Disease (다발성 경화증 질환의 자기공명 T2 강조영상에서 단면 두께 변화에 따른 잡음 평가)

  • Hong, Inki;Park, Minji;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.327-333
    • /
    • 2021
  • Magnetic resonance imaging(MRI) uses strong magnetic field to image the cross-section of human body and has excellent image quality with no risk of radiation exposure. Because of above-mentioned advantages, MRI has been widely used in clinical fields. However, the noise generated in MRI degrades the quality of medical images and has a negative effect on quick and accurate diagnosis. In particular, examining a object with a detailed structure such as brain, image quality degradation becomes a problem for diagnosis. Therefore, in this study, we acquired T2 weighted 3D data of multiple sclerosis disease using BrainWeb simulation program, and used quantitative evaluation factors to find appropriate slice thickness among 1, 3, 5, and 7 mm. Coefficient of variation and contrast to noise ratio were calculated to evaluate the noise level, and root mean square error and peak signal to noise ratio were used to evaluate the similarity with the reference image. As a result, the noise level decreased as the slice thickness increased, while the similarity decreased after 5 mm. In conclusion, as the slice thickness increases, the noise is reduced and the image quality is improved. However, since the edge signal is lost due to overlapped signal, it is considered that selecting appropriate slice thickness is necessary.

Effects of Gadolinium Contrast agent on Bone Mineral Density Measurement using Dual Energy X-ray Absorptiometry (가돌리늄조영제가 이중에너지 X-선 흡수법을 이용한 골밀도검사에 미치는 영향)

  • Lee, Keun-Ohk;Lee, Min-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Radiographic contrast agents are used for diagnostic purposes and are one of the factors affecting measured values in bone density tests. They are absorbed into tissues and have an effect of increasing the measured values of bone density, so they are avoided as much as possible before performing a bone density test. MRI contrast agents, which have different physical properties and mechanisms of action than radiographic contrast agents, are based on gadolinium, a metal element. They have radiopacity characteristics, so MRI are generally performed prior to examination using radiation. The purpose of this study was to investigate the effects of MRI contrast agents on bone mineral density examination using dual energy X-ray absorption. Two types of gadolinium based MRI contrast agents were injected into an acrylic water tank for each volume, and the humanoid spine phantom was inserted and the BMD and T-score from (L1-L4) were analyzed by scanning a total of 30 times, 5 times for each injection type. The average value of the measured total (L1-L4) bone density for each of the two contrast agents was 0.952±0.052, 0.957±0.050, and 0.956±0.05g/㎠, respectively, for the Gadoterate Meglumine component 0mL, 7.5mL and 15mL, when the gadobutrol components were 0mL, 5mL, and 10mL, there was no statistically significant difference at all sites at 0.953±0.001, 0.954±0.001, and 0.945±0.001g/㎠, respectively(p>0.05). The average value of total T-score was -0.46±0.05, -0.4±0, -0.42±0.04 when the Gadoterate Meglumine component was 0mL, 7.5mL and 15mL, respectively. When the Gadobutrol ingredients were 0mL, 5mL and 10mL, there was no statistically significant difference in all areas, with -0.46±0.05, -0.46±0.05, and 0.5±0.00, respectively. In this experiment, the MRI contrast agent was found to have no effect on bone density tests, using the dual-energy X-ray absorption method. There is a limitation in that physical conditions such as kidney and health conditions etc. were not taken into consideration, so further clinical research is expected to be conducted in the future.

Comparison of Differences in Subcortical between Men and Women in their Seventies (70대의 성별에 따른 피질하부 차이 비교)

  • Ahn, Beyung-Ju;Park, Hye-Mi;Kim, Joo-Yeon;Lee, Jeong-hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.585-595
    • /
    • 2020
  • Magnetic resonance imaging(MRI) has become an important technique for examining changes in human brain structure with neurological disorders. Brain development is a very complex process, and is affected by neurogenesiss and genetic programs. As age increases, structures of the brain change, which can contribute to the formation of brain diseases. Among the various factors, Gender is one of the greatest influential factors that affect the development of a healthy brain. The images were analyzed through various programs found in FSL such as SIENAX, FIRST, and Vertex analysis. Our results show that significant gender-related differences in subcortical areas were observed at the particular age group. The magnitude of these differences between gender and volume varied depending on the area investigated. In this study, we used more advanced 3T MRI for the structural analysis of subcortical structures between each gender. In addition, Vertex Analysis was used to visualize the volumetric differences in subcortical structures between each gender. This study is limited to groups in their 70s, therefore, further studies are needed for wider age groups.

A case of megalencephalic leukoencephalopathy with subcortical cysts (피질하 낭종을 동반한 거대뇌성 백질뇌병증 1예)

  • Park, Eun Young;Kim, Young Ok;Kim, Ji Youn;Yeo, Chae Young;Baek, Hee Jo;Kim, Chan Jong;Kim, Eun Young;Woo, Young Jong
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.12
    • /
    • pp.1342-1345
    • /
    • 2008
  • Megalencephalic leukoencephalopathy with subcortical cysts (MLC) is a rare white matter disorder, first described in the early 1990s. The brain in patients with MLC appears swollen on MRI, with diffuse white matter abnormalities; in addition, there is an invariable presence of subcortical cysts, primarily in the anterior temporal region sparing the deep white matter, basal ganglia, thalami, and cerebellum. Patients with MLC present with macrocephaly and neurological abnormalities such as motor deterioration, ataxia, spasticity, and cognitive deficits. We report a twenty-month-old boy who presented with seizures and macrocephaly, delay in development, and abnormal brain MRI findings compatible with the diagnosis of MLC. The brain MRI revealed bilateral hypersignal intense subcortical white matter regions in the frontal, temporal, and parietal lobes on T2-weighted images, which were not yet associated with cystic changes. During follow-up, the frequency of seizures decreased after anticonvulsant medication was started, but the head circumference remained above the 97th percentile, and the patient continued to have developmental delay.

Analysis of Endcap Effect for MRI Birdcage RF Coil by FDTD Method (FDTD 방법을 이용한 MRI Birdcage RF Coil의 Endcap 효과 분석)

  • Chung Sung-Taek;Park Bu-Sik;Shin Yoon-Mi;Kwak June-Sik;Cho Jong-Woon;Kim Kyoung-Nam
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.137-143
    • /
    • 2003
  • Purpose : B1 field of birdcage RF (radiofrequency) coil that is used most for brain imaging in magnetic resonance imaging (MRI) decreases toward endring from the coil center. We investigated how much RE B1 homogeneity effect the endcap shield brings form the coil center as it towards to endcap region. Materials and Methods : We compared RF B1 field distribution by each finite difference time domain (EDTD) simulations for lowpass, highpass and hybrid birdcage RF coils. We selected the highpass birdcage RF coil that was the highest RF B1 field condition as simulation result, and studied how much RF B1 homogeneity effect was occurred when endcap shield was applied to endring area. Results : B1 field of the highpass birdcage RF coil was higher than other birdcage RF coil types as simulation result. However, the RF B1 homogeneity was lower than other coil types. RE B1 field of highpass birdcage RF coil with endcap shield is similar with RF B1 field of hybrid birdcage RF coil and the overall RE B1 homogeneity in sagittal direction was better. Conclusion In this paper, proposed method can apply improving RF B1 homogeneity of RF coil in clinical examination.

  • PDF

Quantitative Analysis of Modified Fermi-Direc Filter applied to Clinical MR Image (임상 MR영상에 적용된 변형 Fermi-Direc필터의 정량적 평가)

  • Kim, Ki-Hong;Kim, Dong-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.225-230
    • /
    • 2009
  • Filtering has been used to improve the image quality not only in MRI but in most image processing fields. In this paper, modified Fermi-Direc filter was transformed in various shapes, and then the optimum shape was designed. In addition, Newly made filter was applied in real clinic, which showed the obvious improvement in image quality. In conclusion, filtered image was superior to original image in contrast and sharpness. Then, this was proved by the histogram of R, G, B channel used for the quantitative analysis.

Primary Central Nervous System Involvement in Peripheral T-Cell Lymphoma: A Case Report (원발성 중추신경계 말초 T 세포성 림프종: 증례 보고)

  • Seung Hee Byun;Da Mi Kim;In Ho Lee;Chang June Song;Kyung Hwan Kim;Song Yi Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.255-260
    • /
    • 2021
  • Primary central nervous system T-cell lymphoma (PCNSTL) is an extremely rare type of brain tumor. There are only few reports on the imaging findings of patients with PCNSTL. Herein, we report the imaging findings of a patient with peripheral T-cell lymphoma-not otherwise specified that presented with numerous small nodular and patchy strongly enhancing lesions on MRI.

Perfusion Impairment in Infantile Autism on Brain SPECT Using Tc-99m ECD : Comparison with MR Findings (유아 자폐증 환아에서의 Tc-99m ECD를 이용한 뇌 단일 광전자 방출 전산화 단층 촬영술상의 관류 저하: 자기 공명 영상과의 비교 분석)

  • Ryu, Young-Hoon;Lee, Jong-Doo;Yoon, Pyeong-Ho;Kim, Dong-Ik;Oh, Young-Taik;Lee, Sun-Ah;Lee, Ho-Bun;Shin, Yee-Jin;Lee, Byung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.320-329
    • /
    • 1997
  • Neuroanatomic substrate of autism has been the subjects of continuing investigation. Because previous studies had not demonstrated consistent and specific neuroimaging findings in autism and most studies comprised adults and school-aged children, we performed a retrospective review in search of common functional and anatomical abnormalities with brain SPECT using Tc-99m ECD and correlative MRI The patient population was composed of 18 children aged 28 to 89 months(mean age : 55 months) who met the diagnostic criteria of autism as defined in the DSM-IV and CARS. Brain SPECT was performed after intravenous injection of 185-370MBq of Tc-99m ECD using brain dedicated annular crystal gamma camera. MRI was performed in all patients including T1, T2 axial and T1 sagittal sequences. SPECT data were visually assessed. Thirteen patients had abnormal SPECT scan revealing focal areas of decreased perfusion. Decreased perfusion of cerebellar vermis(12/18), cerebellar hemisphere(11/18), thalami(13/18), basal ganglia(4/18), posterior parietal(7/18), and temporal(4/18) area were noted on brain SPECT. Whereas, only 3 patients had abnormal MR findings which were subtle volume loss of parieto-occipital white matter in 3 and mild thinning of posterior body of corpus callosum in 2 and slightly decreased volume of cerebellar vermis in 1. Comparison of the numbers of abnormal findings revealed that regional cerebral blood flow (rCBF) abnormalities seen on SPECT were more numerous than anatomical abnormalities seen on MRI. In conclusion, extensive perfusion impairment involving cerebellum, thalami and parietal lobe were found in this study. SPECT may be more sensitive in reflecting pathophysiology of autism than MRI. However, further studies are mandatory to determine the significance of thalamic and parietal perfusion impairment in autism.

  • PDF

Projection-type Fast Spin Echo Imaging (프로젝션 타입 고속 스핀 에코 영상)

  • 김휴정;김치영;김상묵;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.42-51
    • /
    • 2000
  • Purpose: Projection-type Fast Spin Echo (PFSE) imaging is robust to patient motion or flow related artifact compared to conventional Fast Spin Echo (FSE) imaging, however, it has difficulty in controlling $T_2$ contrast. In this paper, Tz contrast in the PFSE method is analyzed and compared with those of the FSE method with various effective echo times by computer simulation. The contrasts in the FSE and PFSE methods are also compared by experiments with volunteers. From the analysis and simulation, it is shown that ${T_2}-weighted$ images can well be obtained by the PFSE method proposed. Materials and methods: Pulse sequence for the PFSE method is implemented at a 1.0 Tesla whole body MRI system and $T_2$ contrasts in the PFSE and FSE methods are analyzed by computer simulation and experiment with volunteers. For the simulation, a mathematical phantom composed of various $T_2$ values is devised and $T_2$ contrast in the reconstructed image by the PFSE is compared to those by the FSE method with various effective echo times. Multi-slice ${T_2}-weighted$ head images of the volunteers obtained by the PFSE method are also shown in comparison with those by the FSE method at a 1.0 Tesla whole body MRI system. Results: From the analysis, $T_2$ contrast by the PFSE method appears similar to those by the FSE method with the effective echo time in a range of SO-lOOms. Using a mathematical phantom, contrast in the PFSE image appears close to that by the FSE method with the effective echo time of 96ms. From experiment with volunteers, multi-slice $T_2-weighted$ images are obtained by the PFSE method having contrast similar to that of the FSE method with the effective echo time of 96ms. Reconstructed images by the PFSE method show less motion related artifact compared to those by the FSE method. Conclusion: The projection-type FSE imaging acquires multiple radial lines with different angles in polar coordinate in k space using multiple spin echoes. The PFSE method is robust to patient motion or flow, however, it has difficulty in controlling $T_2$ contrast compared to the FSE method. In this paper, it is shown that the PFSE method provides good $T_2$ contrast (${T_2}-weighted$ images) similar to the FSE method by both computer simulation and experiments with volunteers.

  • PDF

The Relationship between Neural Foraminal Stenosis and Imaging Features of Lumbar Spine MRI in Patients Older Than 60 Years with Lumbar Radiculopathy (요추신경근병증이 있는 60세 이상의 환자에서 신경공 협착과 자기공명영상 평가를 통한 인자와의 상관관계)

  • Kyeyoung Lee;Hee Seok Jeong;Chankue Park;Maeran Kim;Hwaseong Ryu;Jieun Roh;Jeong A Yeom;Jin Hyeok Kim;Tae Un Kim;Chang Ho Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.862-875
    • /
    • 2021
  • Purpose To investigate the MRI features associated with neural foraminal stenosis (NFS) in patients older than 60 years with lumbar (L) radiculopathy. Materials and Methods This study included 133 retrospectively selected patients older than 60 years with lumbar radiculopathy who had undergone a lumbar spine MRI (from January 2018 to April 2018). For L4/L5 and L5/sacral (S)1 levels, NFS was reviewed blindly by two radiologists. Spondylolisthesis, retrolisthesis, disc height loss, disc bulging/herniation/central canal stenosis, ligamentum flavum thickening, and facet hypertrophy were evaluated separately for the NFS and non-NFS groups, and they were compared using univariate and multivariate analyses. Results The univariate analysis revealed that disc height loss (p = 0.006) was associated with NFS for L4/L5. For L5/S1, both spondylolisthesis (p = 0.005) and facet hypertrophy (p = 0.006) were associated with NFS. The multivariate logistic analysis revealed that disc height loss was associated with NFS for L4/L5 [odds ratio (OR) = 4.272; 95% confidence interval (CI) 1.736-10.514]. For L5/S1, spondylolisthesis (OR = 3.696; 95% CI 1.297-10.530) and facet hypertrophy (OR = 6.468; 95% CI 1.283-32.617) were associated with NFS. Conclusion Disc height loss was associated with NFS for L4/L5 and spondylolisthesis and facet hypertrophy were associated with NFS for L5/S1.