• Title/Summary/Keyword: MRI 영상

Search Result 1,880, Processing Time 0.033 seconds

Tumor Margin Infiltration in Soft Tissue Sarcomas: Prediction Using 3T MRI Texture Analysis (연조직 육종의 종양 가장자리 침윤: 3T 자기공명영상 텍스처 분석을 통한 예측)

  • Minji Kim;Won-Hee Jee;Youngjun Lee;Ji Hyun Hong;Chan Kwon Jung;Yang-Guk Chung;So-Yeon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.112-126
    • /
    • 2022
  • Purpose To determine the value of 3 Tesla (T) MRI texture analysis for predicting tumor margin infiltration in soft tissue sarcomas. Materials and Methods Thirty-one patients who underwent 3T MRI and had a pathologically confirmed diagnosis of soft tissue sarcoma were included in this study. Margin infiltration on pathology was used as the gold standard. Texture analysis of soft tissue sarcomas was performed on axial T1-weighted images (WI) and T2WI, fat-suppressed contrast-enhanced (CE) T1WI, diffusion-weighted images (DWI) with b-value of 800 s/mm2, and apparent diffusion coefficient (ADC) was mapped. Quantitative parameters were compared between sarcomas with infiltrative margins and those with circumscribed margins. Results Among the 31 patients with soft tissue sarcomas, 23 showed tumor margin infiltration on pathology. There were significant differences in kurtosis with the spatial scaling factor (SSF) of 0 and 6 on T1WI, kurtosis (SSF, 0) on CE-T1WI, skewness (SSF, 0) on DWI, and skewness (SSF, 2, 4) on ADC between sarcomas with infiltrative margins and those with circumscribed margins (p ≤ 0.046). The area under the receiver operating characteristic curve based on MR texture features for identification of infiltrative tumor margins was 0.951 (p < 0.001). Conclusion MR texture analysis is reliable and accurate for the prediction of infiltrative margins of soft tissue sarcomas.

Automatic fusion of T2-weighted image and diffusion weighted image in pelvis MRI (골반 T2강조 MR 영상과 확산강조 MR 영상 간 자동 융합)

  • Kang, Hye-Won;Jung, Ju-Lip;Hong, Helen;Hwang, Sung-Il
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06c
    • /
    • pp.359-361
    • /
    • 2012
  • 본 논문은 T2강조 MR 영상과 확산강조 MR 영상의 강체 정합을 통해 크기, 위치, 회전 변환 왜곡을 보정하여 자궁내막암의 위치를 자동으로 찾는 방법을 제안한다. 영상해상도와 밝기값 분포가 서로 다른 두 영상간 정합의 정확성을 향상시키기 위해 잡음을 제거하고 두 영상의 밝기값 신호 분포의 유사성을 강화시킨다. 유사성이 향상된 두 영상의 크기, 위치, 회전 변환 왜곡을 보정하기 위해 정규화 상호정보를 최대화 하는 강체 정합을 반복적으로 수행한다. 정합된 영상에서 악성 종양을 쉽게 판별 할 수 있도록 현상확상계수지도를 컬러맵으로 생성하여 T2강조 MR 영상에서 얻은 종양의 후보군에 매핑하여 T2강조 MR 영상과 융합한다. 실험을 위하여 최적화 반복 과정에 따른 정규화 상호정보 수치 수렴 과정을 확인하고, 융합 후 종양 영역이 매핑되는 것을 육안평가를 통해 분석하였다. 제안방법을 통하여 T2강조 MR 영상과 확산강조 MR 영상을 융합함으로써 종양의 위치를 자동으로 파악하고 자궁내막암의 병기를 확정하는 용도로 활용할 수 있다.

Effects of Magnetic Resonance Imaging on the Human Body : Analysis of differences according to Dental Implant Material (자기공명영상이 인체에 미치는 영향 : 치아임플란트 재료에 따른 차이 분석)

  • Choe, Dea-yeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.481-489
    • /
    • 2018
  • In MRI examination, when irradiating the human body with RF Pulse to acquire images, the portion of the irradiated RF Pulse energy is absorded into the human body, and this will affect the temperature of the human body. If a metal is inserted into the human body even if the same RF Pulse energy is applied, the SAR value increases and the body temperature changes due to the increase in the electromagnetic wave conductivity of the metal. So we measure and compared with the change in the SAR and temperature in the implant material of the dental implant in Brain MRI examinations. Experiments were performed on a human head model using a 64MHz and 128 MHz RF Pulse frequency generated by a 3.0 Tesla MRI apparatus. And then changed material of dental implants to Titanium and $Al_2O_3$. Using the XFDTD program, the changes in SAR and body temperature around the head were examined. When with Titanium the SAR value and temperature of Brain increased, but with $Al_2O_3$ showed lower SAR and temperature as compared with Titanium. The dental implants were low in SAR and temperature of the head in $Al_2O_3$, which are electrical insulators with low electrical conductivity, compared to Titanium, which is an electrical conductor. It is necessary to study the biologic effect of patient with brain MRI when titanium dental implant material is inserted in the future. Because the maximum value of SAR is much higher than the limit when dental implant material is Titanium. In addition, it is necessary to use an implant of $Al_2O_3$ material to reduce the SAR value and temperature of the Brain in Brain MRI examination.

Canine MR Images from 3T Active-Shield MRI System (3T 능동차폐형 자기공명영상 장비로부터 얻어진 개의 자기공명영상)

  • Choe, Bo-Young;Park, Chi-Bong;Kang, Sei-Kwon;Chu, Myoung-Ja;Kim, Euy-Neyng;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.113-124
    • /
    • 2001
  • For veterinary imaging diagnosis, we obtained MR images of the canine brain, spine, kidney and pelvis from 3T MRI system which was equipped with the world first 3T active shield magnet. Spin echo (SE) and fast Spin Echo (FSE) images were obtained from the canine brain, spine, kidney and pelvis of normal and sick dogs using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. In addition, we employed a homemade saddle shaped RF coil. Typical common acquisition parameters were as follows: matrix=512$\times$512, field of view (FOV)=20cm, slice thickness=3 w, number of excitations (NEX)=1. For T1-weighted MR images, we used TR=500 ms, TE=10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE=108 ms. Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.57 system. The high resolution images acquired in this study represent more than a 4-fold increase in in-plane resolution relative to conventional images obtained with a 20 cm field of view and a 5 mm slice thickness. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter The present results demonstrate that the MR images from 3T system could provide better diagnostic quality of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods. Moreover, MRI technique could begin to apply for veterinary medicine in Korea.

  • PDF

"세계적인 뇌과학 R&D 기지 만들터"

  • Sim, Jae-U
    • The Science & Technology
    • /
    • no.9 s.424
    • /
    • pp.20-22
    • /
    • 2004
  • "이제 미지의 영역은 뇌뿐입니다. 영상장치의 수준에 따라 각국의 연구성과는 달라질 겁니다." PET(양전자 방출 단층촬영 장치)를 세계 최초로 개발, 뇌영상 연구분야의 세계 3대 석학 가운데 한 사람으로 꼽히는 UC어바인 조장희(68) 교수는 쩌렁쩌렁한 목소리에 기백이 넘쳤다. 고희를 앞둔 나이가 무색할 정도였다. 한국과학기술원과 광주과학기술원의 초빙 석좌교수 시절(1978~98년)의 거침없는 성격은 변함이 없었고, 뇌과학의 미래에 대한 그의 확신은 여전했다. 조 교수는 자신의 마지막 연구 인생을 조국에서 불태울 수 있는 기회를 잡았다. 가천의대가 조 교수를 영입해 370억 원을 들여 최첨단 뇌과학연구소를 세우기로 한 것이다. 조 교수에게는 15년간 연봉 30만 달러를 보장하는 파격적인 조건을 제시했다. 조 교수가 맡게 될 뇌과학영상연구소는 뇌 속에서 벌어지는 미세한 현상을 손바닥 보듯 들여다볼 수 있는 방법과 장치를 개발하게 된다. 가장 우선적인 목표는 MRI(자기공명 영상장치)와 PET를 합친 영상장치의 세계 최초 개발이다.

  • PDF

Designing boundary detector of the object on SSM (통계 지식 기반(SSM)에서 대상 물체의 경계 검출기 설계)

  • Yoo, Sang-Jin;Park, Jong-Koo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.11a
    • /
    • pp.511-514
    • /
    • 2003
  • 본 연구는 입력된 영상으로부터 특정한 형태를 이루고 있는 대상 물체를 추출함에 있어, 처리에 소요되는 시간 비용(Time cost)을 줄이는 것을 목적으로 하고 있다. 이를 위하여 특정 관심 지역(Region of Interest)이나 대상 물체(Tareet object)의 경계 검출(Boundary detection)을 하는 과정에 통계학적 수치자료(SSM : Statistical Shape Model)를 사용한 접근법을 이용하였다. 또한, 향후 연구 방향인 의료 영상해석(Medical image analysis)으로의 확장성을 고려, 의료 영상 해석에 많이 사용되어지는 MRI, CT, X-Ray 이미지가 Gray level 영상이라는 것을 감안하여 Gray level 영상을 연구 대상으로 삼았다.

  • PDF

Effect of Metals used in Orthopedic on Magnetic Resonance Imaging II (정형 보철용 금속이 자기공명영상에 미치는 영향 II)

  • Kim, Hyeong-Gyun;Choi, Seong-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.5
    • /
    • pp.115-120
    • /
    • 2012
  • Metals used orthopedic in human magnetic resonance imaging scan of the metal to be inserted, The information to users about the image distortion is to propose a basis for judgment. Metals used orthopedic on Stainless, Titanium and Clip using ferromagnetic artifacts and distortion of the image were measured. Using Phantom "Effect of Metals used in Orthopedic on Magnetic Resonance ImagingI" pig in a paper subsequently was carried out using the same bone. Experimental results using a pure Titanium is a relatively high diagnostic value was found that.

Dissociation of the semantic and syntactic processing reflected on fMRI in Korean sentences (기능적 자기공명영상에 나타난 한글 의미.통사 문장 처리의 해리)

  • 이홍재;이동훈;남기춘;이은정;문찬홍;유재옥;나동규
    • Proceedings of the Korean Society for Cognitive Science Conference
    • /
    • 2000.06a
    • /
    • pp.405-410
    • /
    • 2000
  • 본 연구에서는 기능적 자기공명영상을 이용하여 한글 문장의 의미와 통사 처리에 관한 뇌의 활성화 양상을 비교함으로써 한글문장 이해의 과정에 대한 신경해부학적 증거를 찾고자하였다. 6명의 자원자를 대상으로 문장진위판다과제를 이용하여 활성화를 유도하였다. 1.5T 초전도 자기공명영상 장치에서 EPI로 BOLD 기법을 이용하여 기능적 영상을 얻었으며, 영상 후 처리는 SPM99 분석 프로그램을 이용하였다. 의미관련·통사관련 문장 모두 좌·우 전두회(frontal gyrus) 영역에서 활성화되었다. 의미와 통사처리 영역을 구분하기 위하여 감산법을 적용한 결과, 의미처리는 좌반구의 중측두회(middle temporal gyrus) 영역에서, 통사처리는 우반구의 하전두회(BA44) 부위에서 더 많이 활성화되었다. 의미처리에서 더 우세한 성향을 띠는 부위로 밝혀진 중측두회 영역은 의미처리시에 활성화되는 영역으로 보고하는 기존의 연구와 일치하는 결과이다. 의미와 통사 문장처리시의 뇌 활성화 양상은 뇌의 여러 영역에서 중첩되어 있기는 하지만, 특정영역에서의 차이를 보이고 있으므로, 의미와 통사처리기는 다른 기전(mechanism)에 의해서 일어남을 시사해 준다.

  • PDF

The Evaluation of Image Quality using Time of Flight in Intracranial Magnetic Resonance Imaging : Comparison with 1.5 T and 3.0 T (뇌혈관 자기공명영상에서 Time-of-flight(TOF) 기법을 이용한 영상의 질 평가: 1.5 T 와 3.0 T 자기공명영상 비교)

  • Goo, Eunhoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.43-48
    • /
    • 2015
  • Intracrnial 3D TOF MR angiography was performed in 30 normal volunteers with both 1.5 and 3.0 T MRI system with high resolutions. Used Voxel sizes were $0.39{\times}0.39{\times}0.2$(1.5 T) and $0.19{\times}0.19{\times}0.35$(3.0 T), respectively. High image quality and depiction of small vessel branches were equality demonstrated with 1.5 T and 3.0 T HR TOF MRA(p<0.05). Intracranial high resolution TOF MRA with 1.5 T and 3.0 T provides high diagnostic information with having merits and demerits in depiction of vascular branches.

  • PDF

Gamma-Variate Function을 이용한 관류강조영상(Perfusion MRI) 프로그램 개발 및 평가

  • 백현만;김대원;정성택;박민석;류완석;최환준;최보영
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.128-128
    • /
    • 2002
  • 목적: Gamma-Variate Function을 이용하여 뇌 관류에 관련하는 새로운 재구성 영상 (CBV, CBF, MTT, TTP, BAT)을 산출할 수 있는 프로그램을 개발 및 평가 대상 및 방법: 뇌 관류와 관련한 정량적인 재구성 영상(CBV, CBF, MTT, TTP, BAT)을 얻기 위하여 Gamma-Variate Function을 이용한 Post-processing 프로그램을 개발하였다. 자기공명영상은 1.5T & 3.0T Magnum (Medinus Co., Ltd.)을 사용하였으면, 개발된 프로그램 평가를 위해 스핀에코 -EPI 펄스시퀀스(TR 2000 ms, TE 80 ms, FOV 260 mm, matrix 92$\times$128)를 사용하여 관류강조영상을 획득하였다.

  • PDF