• Title/Summary/Keyword: MRI 영상

Search Result 1,880, Processing Time 0.03 seconds

Quantitative analysis of lumbar multifidus atrophy with low back pain patients using Magnetic Resonance Image (자기공명영상(MRI)을 통한 요통환자의 다열근 위축에 대한 정량적 분석)

  • Yang, Dae-Jung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.4
    • /
    • pp.615-621
    • /
    • 2010
  • Purpose : The purpose of this study was to compare chronic LBP patients and asymptomatic subjects on measures of multifidus size (cross-sectional area;CSA, thickness) and symmetry (proportional difference of relatively larger side to smaller side). Methods : Data were obtained from 12 asymptomatic subjects without a prior history of LBP (8 females, 4 males), and a retrospective audit was undertaken of records from 12 chronic low back pain patients (8 females, 4 males). CSA and Thickness of the lumbar multifidus muscles was measured from axial T1-weighted magnetic resonance images(MRI). Results : The results of the analysis showed that chronic LBP patients had significantly smaller multifidus CSA and thickness than asymptomatic subjects at L4-5 vertebral levels(p<.05). The asymmetry between sides was seen at L4- L5 vertebral level in patients with chronic low back pain presentations(p<.05). Conclusions : MRI provided a quantitative measure of change between asymptomatic subjects and chronic low back pain patients of multifidus muscle. MRI identified significant differences in cross-sectional area and thickness and helps to evaluate clinically and plan the treatment modalities of LBP.

Encoding Mechanisms of Spacing Effect: An event-related fMRI Study (간격효과의 부호화 기전: An event-related fMRI 연구)

  • Park Tae-jin
    • Korean Journal of Cognitive Science
    • /
    • v.16 no.4
    • /
    • pp.255-270
    • /
    • 2005
  • Memory for repeated items is better if they are repeated in a spaced than in a massed fashion (Sparing effect). To investigate the neural mechanisms of sparing effect and successful encoding, lags of repetition were manipulated at encoding stage in an event-related MU study. The behavioral data showed typical spacing effect on recognition judgment, and greater activity for items that were repeated in a spaced fashion than for items that were repeated in a massed fashion has been observed in dorsolateral frontal cortex(DLFC) and ventrolateral frontal cortex(VLFC) of left hemisphere. These conical regions also showed greater activity for novel items than for items that were repeated in a massed fashion. These findings suggest that sparing effect and its relevant successful encoding are attributed to higher level of attentional control and semantic processing.

  • PDF

The Approach Method for the Performance Comparison of Magnetic Resonance Imager (자기공명영상장치의 성능비교를 위한 접근방법)

  • Yi, Y.;Ju, H.Y.;Kim, I.Y.;Lee, M.W.;Ahn, C.B.;Oh, C.H.;Lee, H.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.75-78
    • /
    • 1997
  • In the accessment of the performance of a magnetic resonance imaging unit, there are many parameters to be measured. Such measured parameters are not often meaning by itself. Namely, it need to be compared with some standard. Since there is no gold standard MRI, only can be compared with a worldly renowned product. In this report, we attempted to compare a few MRI parameters for the accessment of the performance of 1 Tesla MRI unit which is domestically developed. Though we did not measure all the parameters related to hardware aspects and software aspects for the full comparison, there few parameters may elucidate some important aspects of MRI unit.

  • PDF

Acoustic Effects on fMRI : A Study on Auditory, Motor and Visual cortices (소음이 뇌기능 영상에 미치는 영향 : 청각, 운동, 시각 피질에 관한 연구)

  • Chung, S.C.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.71-74
    • /
    • 1997
  • MR acoustic sound or noise due to gradient pulsings has been one of the problems in MRI, both in patient scanning as well as in many areas of psychiatric and neuroscience research, such as brain fMRI. Especially in brain fMRI, sound noise is one of the serious noise sources which obscures the small signals obtainable from the subtle changes occurring in oxygenation status in the cortex and blood capillaries. Therefore, we have studied the effects of acoustic or sound noise arising in fMR imaging of the auditory, motor and visual cortices. The results show that the acoustical noise effects on motor and visual responses are opposite. That is, for the motor activity, it shows an increased total motor activation while for the visual stimulation, corresponding (visual) cortical activity has diminished substantially when the subject is exposed to a loud acoustic sound. Although the current observations are preliminary and require more experimental confirmation, it appears that the observed acoustic-noise effects on brain unctions, such as in the motor and visual cortices, are new observations and could have significant consequences in data observation and interpretation in future fMRI studies.

  • PDF

A Diagnostic Ultrasound Imaging System (초음파 영상진단장치)

  • Lee, Seong-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.3
    • /
    • pp.217-232
    • /
    • 1999
  • The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result. their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result. the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described.

  • PDF

Effect of Antibacterial Film Containing Silver Ions on MRI (은(Ag)이온이 함유된 항균필름이 MRI에 미치는 영향)

  • Shin, Byeong Geun;Kim, Seong Hu;Ahn, Seong Min
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.219-224
    • /
    • 2021
  • The purpose of these experiments is often to scan infected patients with MRI. Therefore, it is to investigate whether the antibacterial film containing silver ions, which is a non-magnetic substance, affects magnetic resonance imaging. In this experiment, the ACR phantom was used, not the patient. The ACR phantom was wrapped in an antibacterial film and the SNR, CNR, sagittal localization image, and geometrical accuracy were compared before and after. The experiment was performed 10 times and the averaged values were compared. There were no significant differences in the results of all experiments. The FDA recommends removing metal and antibacterial film masks during MRI scans. The reason is that there was one case of injury with facial burns. When I touched the antibacterial film to check the fever during the 2 hour experiment, I did not feel any particular fever. In light of the experimental results, it would be helpful to use an antibacterial film when testing an infected patient. The reason is that there isn't a difference before and after the experiment of SNR, CNR, and sagittal localization images.

Diagnosis Atherosclerosis Model Using Radiomics Approach in Carotid Vessel MRI (경동맥 혈관 MRI에서 라디오믹스를 이용한 동맥경화증 진단 모델)

  • Kim, Jong-hun;Park, Hyunjin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.289-290
    • /
    • 2022
  • Arteriosclerosis is a disease in which the carotid vessel wall becomes thick, and it is important to monitor the thickness of the vessel wall for diagnosis. In this study, we propose a model for extracting 324 radiomics features from carotid MRI images and diagnosing arteriosclerosis using machine learning techniques. We learned a total of four classification models: logistic regression, support vector machine, random forest, and XGBoost through radiomics features. XGBoost model, which showed the highest performance in 5-fold cross-validation, shows the results of accuracy 0.9023, sensitivity 0.9517, specificity 0.8035, AUC 0.8776.

  • PDF

MR Imaging of Congenital Heart Diseases in Adolescents and Adults

  • Yeon Hyeon Choe;I-Seok Kang;Seung Woo Park;Heung Jae Lee
    • Korean Journal of Radiology
    • /
    • v.2 no.3
    • /
    • pp.121-131
    • /
    • 2001
  • Echocardiography and catheterization angiography suffer certain limitations in the evaluation of congenital heart diseases in adults, though these are overcome by MRI, in which a wide field-of view, unlimited multiplanar imaging capability and three-dimensional contrast-enhanced MR angiography techniques are used. In adults, recently introduced fast imaging techniques provide cardiac MR images of sufficient quality and with less artifacts. Ventricular volume, ejection fraction, and vascular flow measurements, including pressure gradients and pulmonary-to-systemic flow ratio, can be calculated or obtained using fast cine MRI, phase-contrast MR flow-velocity mapping, and semiautomatic analysis software. MRI is superior to echocardiography in diagnosing partial anomalous pulmonary venous connection, unroofed coronary sinus, anomalies of the pulmonary arteries, aorta and systemic veins, complex heart diseases, and postsurgical sequelae. Biventricular function is reliably evaluated with cine MRI after repair of tetralogy of Fallot, and Senning's and Mustard's operations. MRI has an important and growing role in the morphologic and functional assessment of congenital heart diseases in adolescents and adults.

  • PDF

Practical Considerations of Arterial Spin Labeling MRI for Measuring the Multi-slice Perfusion in the Human Brain (스핀 라벨링 자기공명영상을 이용한 사람 뇌에서의 뇌 관류영상의 현실적 문제점을 향상 시키는 방법 연구)

  • Jahng, Geon-Ho
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • In this work practical considerations of a pulsed arterial spin labeling MRI are presented to reliable multi-slice perfusion measurements In the human brain. Three parameters were considered in this study. First, In order to improve slice profile and Inversion efficiency of a labeling pulse a high power Inversion pulse of adiabatic hyperbolic secant was designed. A $900^{\circ}$ rotation of the flip angle was provided to make a good slice profile and excellent Inversion efficiency. Second, to minimize contributions of a residual magnetization be4ween Interleaved scans of control and labeling we tested three different conditions which were applied 1) only saturation pulses, 2) only spotter gradients, and 3) combinations of saturation pulses and spotter gradients Applications of bo4h saturation pulses and spoiler gradients minimized the residual magnetization. Finally, to find a minimum gap between a tagged plane and an imaging plane we tested signal changes of the subtracted image between control and labeled Images with varying the gap. The optimum gap was about 20mm. In conclusion, In order to obtain high quality of perfusion Images In human brain It Is Important to use optimum parameters. Before routinely using In clinical studios, we recommend to make optimizations of sequence parameters.

  • PDF

Classification of Magnetic Resonance Imagery Using Deterministic Relaxation of Neural Network (신경망의 결정론적 이완에 의한 자기공명영상 분류)

  • 전준철;민경필;권수일
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.137-146
    • /
    • 2002
  • Purpose : This paper introduces an improved classification approach which adopts a deterministic relaxation method and an agglomerative clustering technique for the classification of MRI using neural network. The proposed approach can solve the problems of convergency to local optima and computational burden caused by a large number of input patterns when a neural network is used for image classification. Materials and methods : Application of Hopfield neural network has been solving various optimization problems. However, major problem of mapping an image classification problem into a neural network is that network is opt to converge to local optima and its convergency toward the global solution with a standard stochastic relaxation spends much time. Therefore, to avoid local solutions and to achieve fast convergency toward a global optimization, we adopt MFA to a Hopfield network during the classification. MFA replaces the stochastic nature of simulated annealing method with a set of deterministic update rules that act on the average value of the variable. By minimizing averages, it is possible to converge to an equilibrium state considerably faster than standard simulated annealing method. Moreover, the proposed agglomerative clustering algorithm which determines the underlying clusters of the image provides initial input values of Hopfield neural network. Results : The proposed approach which uses agglomerative clustering and deterministic relaxation approach resolves the problem of local optimization and achieves fast convergency toward a global optimization when a neural network is used for MRI classification. Conclusion : In this paper, we introduce a new paradigm to classify MRI using clustering analysis and deterministic relaxation for neural network to improve the classification results.

  • PDF