• Title/Summary/Keyword: MRI 영상

Search Result 1,880, Processing Time 0.035 seconds

CT and MRI Findings of Low-Flow Mediastinal Vascular Malformation: A Case Report (종격동에 발생한 저혈류성 혈관 기형의 영상 소견: 증례 보고)

  • Hanlim Song;Mi Sook Lee;Soo-yeon Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.204-209
    • /
    • 2024
  • Mediastinal vascular malformations are rare and their diagnosis can be challenging. Imaging is vital for diagnosing mediastinal vascular malformations and can help avoid unnecessary invasive procedures. Herein, we report the detailed CT and MRI findings of a rare low-flow mediastinal vascular malformation in an asymptomatic 63-year-old male.

Transcranial radiograph and magnetic resonance imaging in the evaluation of osseous changes of the temporomandibular joint (경두개방사선사진과 자기공명영상을 이용한 측두하악관절 골변화에 관한 연구)

  • Cho Su-Beom;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.32 no.2
    • /
    • pp.99-105
    • /
    • 2002
  • Purpose: To evaluate the diagnostic accuracy of transcranial radiographs and magnetic resonance imaging (MRI) of the temporomandibular joint (TMJ) in the assessment of osseous changes of the condylar head and articular eminence. Materials and Methods: Osseous changes of the TMJ were evaluated in forty-three patients. Osseous changes of the condylar head and articular eminence were observed in 41 joints and 64 joints, respectively on transcranial radiographs, and 48 joints and 59 joints, respectively on MRI. Results: The flattening, sclerosis, erosion, and osteophyte formation of the condylar heads were observed in 36.6%, 43.9%, 12.2%, and 7.3%, respectively on transcranial radiographs compared with 35.4%, 20.8%, 37.5%, and 6.3%, respectively on MRI. While, the flattening, sclerosis, and erosion of the articular eminences were observed in 26.6%, 67.2%, and 6.2%, respectively on transcranial radiographs compared with 32.2%, 59.3%, and 8.5%, respectively on MRI. Conclusion: There were no statistical differences between transcranial radiographs and MRI scans in the detection of osseous changes of the TMJ. However, MRI scans were superior to the transcranial radiographs in the detection of erosion of the condylar head (p<0.01).

  • PDF

FDTD Modeling of the Korean Human Head using MRI Images (MRI 영상을 이용한 한국인 인체 두부의 FDTD 모델링)

  • 이재용;명노훈;최명선;오학태;홍수원;김기회
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.4
    • /
    • pp.582-591
    • /
    • 2000
  • In this paper, the Finite-Difference Time-Domain(FDTD) modeling method of the Korean human head is introduced to calculate electromagnetic energy absorption for the human head by mobile phones. After MRI scanning data is obtained, 2 dimensional(2D) segmentation is done from the 2D MRI image data by the semi-automatic method. Then, 3D dense segmentation data with $1mm\times1mm\times1mm$ is constructed from the 2D segmentation data. Using the 3D segmentation data, coarse FDTD models of human head that is tilted arbitrarily to model the condition of tilted usage of mobile phone.

  • PDF

Magnetic resonance imaging findings of the retrodiskal tissue in TMJ internal derangement (측두하악관절 내장증에서의 관절원판 후조직의 자기공명영상)

  • Cho Bong-Rae
    • Imaging Science in Dentistry
    • /
    • v.33 no.2
    • /
    • pp.63-70
    • /
    • 2003
  • Purpose: To describe the MRI findings of the retrodiskal tissue in patients presenting with TMJ internal derangement and to correlate these findings with clinical and other MRI manifestations. Materials and Methods: One hundred eighteen joints of 63 patients with TMJ internal derangement were examined by MRI. Tl-weighted sagittal MR images taken in both closed- and open-mouth were evaluated for the presence of demarcation between disk and retrodiskal tissue, the presence of low signal intensity, and the depiction of the temporal part of the posterior attachment. The results were correlated with the duration of TMJ internal derangement, the presence of pain, and other MRI findings, including the type of internal derangement, the extent of disk displacement, the degree of disc deformation, and the presence of osteoarthrosis. Results: A significant relationship between the presence of low signal intensity in the retrodiskal tissue and other MRI findings was determined. Low signal intensity on the open-mouth view was observed more frequently in patients with disc displacement without reduction, severe disc displacement and deformation, and osteoarthrosis (p<0.05). The demarcation between disk and retrodiskal tissue, and the depiction of the temporal part of the posterior attachment(TPA) were correlated neither with clinical, nor with other MRI findings. Conclusion: This study suggests that low signal intensity in the retrodiskal tissue on open-mouth MR image can be indicative of advanced stages of disk displacement.

  • PDF

Diagnostic Reliability & Case Reports Of The Dynamic MRI For Temporomandibular Joint Disease (악관절증의 진단을 위한 역동적 자기공명 영상의 이용 및 증례)

  • Park, Jin-Ho;Chin, Byung-Rho;Byun, Woo-Mok
    • Journal of Yeungnam Medical Science
    • /
    • v.12 no.1
    • /
    • pp.141-148
    • /
    • 1995
  • The Magnetic resonance imaging has been used widely to evaluate the disk position without any interruption of the TMJ structures, and the dynamic MRI presenting computed serial imaging or the video-recorded simulation images is thought to be very effective to evaluate the disk position under function. This is to study the correlation between the clinical diagnosis and the findings of dynamic MRI for diagnosis of internal derangement of the 7 patients were examined clinically, and the movement of TMJ meniscus was reviewed in the dynamic MRI. MRI was very reliable to diagnose the amount of anterior displacement of articular disc, the structural abnormality of temporomandibular joint, the cause of functional limitation, and to differentiate the muscle related pain & dysfunction.

  • PDF

A Study on Magnetic Resonance Imaging Scan to Measure Bacterial Contamination and Disinfection of Equipment Status (자기공명영상(MRI)검사 장비의 세균오염도 측정 및 소독 실태에 관한 연구)

  • Lim, Chung-Hwan;Jeung, Seung-Woon;Kim, Eung-Hee
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2013.05a
    • /
    • pp.213-214
    • /
    • 2013
  • 본 연구는 밀폐된 공간과 다른 검사보다 시간이 오래 걸리는 자기공영상(MRI)검사 장비에서 환자와의 접촉이 많은 Head coil, Block, 밀폐된 공간인 Bore 등의 세균오염도를 측정 및 세균의 종류를 파악하고, 설문을 통하여 감염관리 실태를 파악하고 자기공명영상(MRI)장비의 소독 상태를 파악함으로써 환자의 병원감염에 대한 인식의 개선과 소독의 중요성을 제시하고자 한다.

  • PDF

Understanding of Perfusion MR Imaging (관류자기공명영상의 이해)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.1
    • /
    • pp.27-31
    • /
    • 2013
  • Perfusion MR imaging is how to use exogenous and endogenous contrast agent. Exogenous perfusion MRI methods which are dynamic susceptibility contrast using $T2^*$ effect and dynamic contrast-enhanced using T1 weighted image after injection contrast media. An endogenous perfusion MRI method which is arterial spin labeling using arterial blood flow in body. In order to exam perfusion MRI in human, technical access are very important according to disease conditions. For instance, dynamic susceptibility contrast is used in patients with acute stroke because of short exam time, while dynamic susceptibility contrast or dynamic contrast enhancement provides the various perfusion information for patients with tumor, vascular stenosis. Arterial spin labeling is useful for children, women who are expected to be pregnant. In this regard, perfusion MR imaging is required to understanding, and the author would like to share information with clinical users

  • PDF

A Study on the Measurement of Bacterial Contamination of MRI Examination Equipment and Disinfection Conditions (자기공명영상검사장비의 세균오염도 측정 및 소독에 관한 연구)

  • Jeung, Seung-Woon;Lim, Chung-Hwan;You, In-Gyu
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.665-672
    • /
    • 2013
  • In radiology department, where patients with a variety of diseases receive their tests, there is a large possibility of cross contamination of nosocomial infection. Magnetic resonance imaging (MRI) tests take particularly more time than other tests do, which increases the possibility of being exposed to cross contamination. Therefore, this research examines the status of MRI equipment sterilization and investigates the bacterial distribution on head coils, which have the most frequent contact with patients, patient fixation blocks, and bores, which are confined spaces. The status of MRI equipment disinfection was examined by a survey targeting 150 employees, and the distribution of bacteria was measured in ten medical facilities. The result of bacterial distribution tests on MRI equipment showed various bacteria, including Staphylococcus, Acinetobacter, Sphingomona, Pantoea agglomeranss, Micrococcus, Bacillus, Saprophyticus, Brevundimona, and Myroidesspecies. The result of examining the stat us of MRI room disinfection showed that the disinfections of the head coil, block, and bore were implemented well, and the largest proportion was carried out once a day in the morning. The time and implementation of disinfection by the disinfection manager showed that they were implemented well when the manager was the MRI room examiner. The disinfection after examining a patient using an appropriate disinfectant is mandatory to prevent cross contamination.

Visualization Scheme for Query Result of Medical Image Using 3D Block Metaphor (3차원 블록 메타포어를 이용한 의료 영상의 질의 결과 시각화 방안)

  • 최용화;엄기현
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2000.11a
    • /
    • pp.73-76
    • /
    • 2000
  • 본 논문은 의료 영상 검색 시스템에서 뇌 MRI 이미지 데이터베이스에서 사용자의 질의를 만족하는 질의 결과 집합에 대한 시각화 방안을 제안한다. 한 환자의 뇌 MRI 이미지를 검색 결과로 제시할 경우 종류별, 방향별로 다양하고 여러 환자의 경우에는 그 양이 더욱 방대해진다. 이러한 뇌 MRI 이미지를 공간 제약적인 화면에 표현하는데는 한계가 있다. 따라서 본 논문에서는 질의 결과를 제시할 대 유사도가 높은 순서로 나열하고, 사용자 요구에 따른 관련 이미지를 종류와 방향별로 제시하여 이미지 조작을 가능하게 한다. 도한, 제시된 뇌 MRI 이미지를 효율적으로 브라우징할 수 있도록 3차원 블록 메타포어를 이용한 시각화 인터페이스를 통하여 공간 활용도의 향상과 사용자 인터페이스의 편의성 및 인지도를 증진한다.

  • PDF

High-resolution Spiral-scan Imaging at 3 Tesla MRI (3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상)

  • Kim, P.K.;Lim, J.W.;Kang, S.W.;Cho, S.H.;Jeon, S.Y.;Lim, H.J.;Park, H.C.;Oh, S.J.;Lee, H.K.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.108-116
    • /
    • 2006
  • Purpose : High-resolution spiral-scan imaging is performed at 3 Tesla MRI system. Since the gradient waveforms for the spiral-scan imaging have lower slopes than those for the Echo Planar Imaging (EPI), they can be implemented with the gradient systems having lower slew rates. The spiral-scan imaging also involves less eddy currents due to the smooth gradient waveforms. The spiral-scan imaging method does not suffer from high specific absorption rate (SAR), which is one of the main obstacles in high field imaging for rf echo-based fast imaging methods such as fast spin echo techniques. Thus, the spiral-scan imaging has a great potential for the high-speed imaging in high magnetic fields. In this paper, we presented various high-resolution images obtained by the spiral-scan methods at 3T MRI system for various applications. Materials and Methods : High-resolution spiral-scan imaging technique is implemented at 3T whole body MRI system. An efficient and fast higher-order shimming technique is developed to reduce the inhomogeneity, and the single-shot and interleaved spiral-scan imaging methods are developed. Spin-echo and gradient-echo based spiral-scan imaging methods are implemented, and image contrast and signal-tonoise ratio are controlled by the echo time, repetition time, and the rf flip angles. Results : Spiral-scan images having various resolutions are obtained at 3T MRI system. Since the absolute magnitude of the inhomogeneity is increasing in higher magnetic fields, higher order shimming to reduce the inhomogeneity becomes more important. A fast shimming technique in which axial, sagittal, and coronal sectional inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the inhomogeneity map is applied. For phantom and invivo head imaging, image matrix size of about $100{\times}100$ is obtained by a single-shot spiral-scan imaging, and a matrix size of $256{\times}256$ is obtained by the interleaved spiral-scan imaging with the number of interleaves of from 6 to 12. Conclusion : High field imaging becomes increasingly important due to the improved signal-to-noise ratio, larger spectral separation, and the higher BOLD-based contrast. The increasing SAR is, however, a limiting factor in high field imaging. Since the spiral-scan imaging has a very low SAR, and lower hardware requirements for the implementation of the technique compared to EPI, it is suitable for a rapid imaging in high fields. In this paper, the spiral-scan imaging with various resolutions from $100{\times}100$ to $256{\times}256$ by controlling the number of interleaves are developed for the high-speed imaging in high magnetic fields.

  • PDF