• Title/Summary/Keyword: MRA2

Search Result 169, Processing Time 0.02 seconds

Evaluation of Barley Bran Sauce Aroma by Multiple Regression Analysis

  • Choi, Ung-Kyu
    • Food Science and Biotechnology
    • /
    • v.14 no.5
    • /
    • pp.656-660
    • /
    • 2005
  • The relationship between the gas chromatographic (GC) patterns of sauce made of barley bran and ranked order in sensory analysis was investigated by multiple regression analysis (MRA). Most of the 42 barley bran sauce samples comprised about 34 peaks, in which the content of 9, 12-octadecanoic acid methyl ester was the highest, followed by those of 2-furanmethanol and 2-furancarboxaldehyde. It is difficult to estimate the aroma quality of barley bran sauce samples on the basis of only one peak. The 34 aroma compounds of the 42 samples were analyzed by an MRA model featuring six transformations. The most precise fit was calculated from the absolute value transformed with the root square of each peak, and the multiple determination coefficient showed that 91.6% of the variation in the sensory score could be explained on the basis of GC data.

MODELING AND MULTIRESOLUTION ANALYSIS IN A FULL-SCALE INDUSTRIAL PLANT

  • Yoo, Chang-Kyoo;Son, Hong-Rok;Lee, In-Beum
    • Environmental Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.88-103
    • /
    • 2005
  • In this paper, data-driven modeling and multiresolution analysis (MRA) are applied for a full-scale wastewater treatment plant (WWTP). The proposed method is based on modeling by partial least squares (PLS) and multiscale monitoring by a generic dissimilarity measure (GDM), which is suitable for nonstationary and non-normal process monitoring such as a biological process. Case study in an industrial plant showed that the PLS model could give good modeling performance and analyze the dynamics of a complex plant and MRA was useful to detect and isolate various faults due to its multiscale nature. The proposed method enables us to show the underlying phenomena as well as to filter out unwanted and disturbing phenomena.

Evaluation of the Cause of Internal Jugular Vein Obstruction on Head and Neck Contrast Enhanced 3D MR Angiography Using Contrast Enhanced Computed Tomography (조영증강 전산화단층촬영술을 이용한 두경부 조영증강 삼차원 자기공명혈관촬영술에서 내경정맥 폐쇄의 원인 평가)

  • Gweon, Hye-Mi;Chung, Tae-Sub;Suh, Sang-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.41-47
    • /
    • 2011
  • Purpose : To evaluate the cause of internal jugular vein (IJV) obstruction on contrast enhanced 3D MR angiography (CE-MRA) using contrast enhanced computed tomography (CE-CT). Materials and Methods : A total number of 30 patients were enrolled, who underwent both head and neck CE-MRA and CE-CT from 2005 to 2008. We defined obstruction group which had IJV obstruction and control group which had no IJV obstruction on CE-MRA. The following parameters were measured from axial images of CE-CT: 1) diameter of IJV; 2) distance between the styloid process and ipsilateral lateral mass of the atlas; 3) maximum area of lateral mass of the atlas. Each parameter was compared between obstruction group and control group. Results : The diameter of IJV and distance between the styloid process and lateral mass of the atlas at IJV obstruction side in obstruction group were $1.6{\pm}1.0\;mm$ and $4.1{\pm}2.1\;mm$ respectively, which resulted in statistical significance (p<0.01). The maximum area of lateral mass of the atlas at IJV obstruction side in obstruction group was $103.4{\pm}25.3\;mm^2$ which is significantly larger than in control group (p<0.05). Conclusion : We found that the cause of IJV obstruction on CE-MRA could be narrow space between the styloid process and the lateral mass of the atlas, which was related with asymmetric larger area of lateral mass of atlas.

Effectiveness of 32-element Surface Coil Array for Accelerated Volume-Targeted Breath-Hold Coronary MRA (체적 지향형 호흡정지 자기공명 조영술의 가속화에 대한 32채널 코일 어레이의 효용성)

  • Lee, Hyun-Yeol;Suh, Jin-Suck;Park, Jae-Seok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.137-145
    • /
    • 2009
  • Purpose : To compare 12 and 32-element surface coil arrays for highly accelerated coronary magnetic resonance angiography (MRA) using parallel imaging. Materials and Methods : Steady state free precession coronary MRA was performed in 5 healthy volunteers at 1.5 T whole body MR scanner using both 12 and 32-element surface coil arrays. Left anterior descending and right coronary artery data sets were acquired for each volunteer. Data sets were sub-sampled for parallel imaging using reduction factors from 1 to 6. Mean geometry factor (g-factor), maximum g-factor, and artifact level were calculated for each of the two coil arrays. Results : Over all reduction factors, the mean and maximum g-factors and artifact level were significantly reduced using the 32-element array compared to the 12element array (P << 0.1). The mean g-factor was sensitive to the imaging orientations of coronary arteries while the maximum g-factor and artifact level were independent of orientation. Conclusion : The 32-element surface coil array significantly improves artifact and noise suppression for highly accelerated coronary MRA using parallel imaging. The increased acceleration factors made feasible with the 32-element array offer the potential to enhance spatial resolution or increase volumetric coverage for 3D coronary MRA.

  • PDF

A Study of Signal Intensity of MRA in Flow Phantom of Fusiform Aneurysm (방추형 동맥류 모형에서 자기공명 혈관조영술의 신호강도에 대한 연구)

  • 한기석
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.83-88
    • /
    • 1998
  • Purpose : Authors correlated the three-dimensional time-of-flight MRA signal intensity characteristics and flow profile simulated by computer in an experimental flow phantom model. Materials and Methods : The three-dimensional time-of-flight MRA was performed in a fusiform flow phantom and analyzed the flow signal. computer assisted flow simulation was performed in same flow geometry. The MRA signal intensity and flow velocity distribution and direction was compared. Results : The flow was depicted as homogeneous signal internsity in inlet and outlet area and inhomogeneous signal intensity in fusiform area. Typically, the flow was depicted as target appearance in transition area to outlet. Whereas mean signal internsity decreased slowly in fusiform area, it rapidly dropped and resumed in transition area to outlet. In computer assisted flow simulation, Whereas there were flow velocity decrease and flow direction change to peripheral in entrance to fusiform area, ther were rapid flow velocity resuming and flow direction change to central in transition area to outlet. Conclusion : The signal loss and target appearance in transition area to outlet is characteristic of fusiform flow. These signal changes correlate with abrupt flow velocity and direction change well.

  • PDF

Analysis of Images According to the Fluid Velocity in Time-of-Flight Magnetic Resonance Angiography, and Contrast Enhancement Angiography

  • Kim, Eng-Chan;Heo, Yeong-Cheol;Cho, Jae-Hwan;Lee, Hyun-Jeong;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • v.19 no.2
    • /
    • pp.185-191
    • /
    • 2014
  • In this study we evaluated that flow rate changes affect the (time of flight) TOF image and contrast-enhanced (CE) in a three-dimensional TOF angiography. We used a 3.0T MR System, a nonpulsatile flow rate model. Saline was used as a fluid injected at a flow rate of 11.4 cm/sec by auto injector. The fluid signal strength, phantom body signal strength and background signal strength were measured at 1, 5, 10, 15, 20 and 25-th cross-section in the experienced images and then they were used to determine signal-to-noise ratio and contrast-to-noise ratio. The inlet, middle and outlet length were measured using coronal images obtained through the maximum intensity projection method. As a result, the length of inner cavity was 2.66 mm with no difference among the inlet, middle and outlet length. We also could know that the magnification rate is 49-55.6% in inlet part, 49-59% in middle part and 49-59% in outlet part, and so the image is generally larger than in the actual measurement. Signal-to-noise ratio and contrast-to-noise ratio were negatively correlated with the fluid velocity and so we could see that signal-to-noise ratio and contrast-to-noise ratio are reduced by faster fluid velocity. Signal-to-noise ratio was 42.2-52.5 in 5-25th section and contrast-to-noise ratio was from 34.0-46.1 also not different, but there was a difference in the 1st section. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s. Consequently, 3D TOF MRA tests show that the faster fluid velocity decreases the signal-to-noise ratio and contrast-to-noise ratio, and basically it can be determined that 3D TOF MRA and 3D CE MRA are displayed larger than in the actual measurement.

Clinical Analysis of Frostbite (동상의 임상적 분석)

  • Choi, Jang Kyu;Kim, Hyun Chul;Shin, Hong Kyung
    • Journal of Trauma and Injury
    • /
    • v.28 no.3
    • /
    • pp.158-169
    • /
    • 2015
  • Purpose: Frostbite can affect still soldiers. Initial clinical manifestations are similar for superficial and deep frostbite, so early treatment is identical. It is under-estimated by physicians. We try to identify the challenges of managing these complex tissue injuries. Methods: A retrospective analysis of 84 patients hospitalized at AFCH from 2009 to 2015 was conducted. We investigated differences of epidemiological characteristics, identification of soft tissue injury, treatment and complications between superficial (SF: 43; 51.2%) and deep (DF: 41; 48.8%) frostbite. Results: The major (94.0%) developed frostbite in dry circumstances (89.3%). Wet circumstances (66.7%) were more susceptible to DF rather than dry (46.7%). The 38 (45.2%) arrived to specialist within 7days. Most prone sites were feet, followed by hands. Toes had more deep injuries. DF presented more increased levels of ALT, CPK, CKMB, CRP. The bone scan of W+S+ was 48.3%, 87.1% and W+S- was 20.7%, 12.9%, respectively. The treatment resulted in improved or normalized perfusion scan with matching clinical improvement. It was a good tool to assess treatment response. Eighteen normal and 8 stenotic type of PCR resulted in normal with matching clinical improvement. One continuous obstructive waveform led to minor amputation. Twelve underwent both PCR and MRA. Among 6 normal PCR, 5 showed normal and one stenosis in MRA. All 5 stenosis and one obstruction showed the same findings in MRA. It was a good tool to evaluate vascular compromise. They were treated with rapid rewarming (11.6%, 22.0%), hydrotherapy (16.3%, 29.3%), respectively. Six (14.6%) underwent STSG, 2 (4.9%) had digital amputation in DF. Berasil, Ibuprofen, Trental were commonly administered. PGE1 was administered selectively for 6.8, 10.8 days, respectively. Raynaud's syndrome (16.3%), CRPS (4.7%), LOM (14.6%) and toe deformity (4.9%) were specific sequelae. Conclusion: We should recommend intensive foot care education, early rewarming and evacuation to specialized units. The bone scanning and PCR should allow for a more aggressive and active approach to the management of tissue viability.

  • PDF