• Title/Summary/Keyword: MR3

Search Result 1,651, Processing Time 0.031 seconds

A Study of Optimal SOAmin for Motor and Language Tasks in Event-related fMRI using Stochastic Design (통계학적 자극설계를 이용한 Event-related fMRl에서 운동과 언어과제의 최적 SOAmin에 대한 연구)

  • 문찬홍;유재욱;나동규;이은정;변홍식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.28-34
    • /
    • 2002
  • Purpose : The minimum stimulus onset asynchronoy(SOAmin) is one of important experimental parameters for an event-related fMRI experiment designed with the stochastic stimulus. In this study, the most efficient SOAmin is explored for the stronger activation in motor and language tasks with the stimulus designed stochastically. Materials and methods : The event-related fMRI during motor and language tasks were obtained in four normal right-handed subjects. EPI-BOLD sequence is used at 1.5Tesla MR system for the acquisition of event-related fMRI. For each task the subjects are responded for the stimulus' with 2, 3, 4, and 6 seconds SOAmin. The obtained images are processed with SPM99, and the p value is set as 0.05 for the significant activation detection. The Z value and the number of activated pixels are compared for each task. Results : For the motor task, the primary and supplementary motor areas are activated, and for the language task the consistent activated signals are detected in the Broca's. The activated signal is to be stronger for the shorter SOAmin for both motor and language tasks. At primary motor area, the activated signals is the strongest for 3 seconds SOAmin and for the supplementary motor area the result with 2 seconds SOAmin shows the strongest activation. And the result of language task shows the strongest activation at the 2 seconds SOAmin. Conclusion : In the event-related fMRI of motor and language tasks with the stochastically designed stimulus, the 2 or 3 seconds SOAmin is efficient for more activated and clustered activation.

  • PDF

Clinical Results from Single-Fraction Stereotactic Radiosurgery (SRS) of Brain Arteriovenous Malformation: Single Center Experience (뇌동정맥기형에서 선형가속기를 이용한 방사선 수술 후의 임상적 결과)

  • Lim, Soo-Mee;Lee, Re-Na;Suh, Hyun-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.274-280
    • /
    • 2010
  • The purpose of this study was to analyze the effect of single-fraction stereotactic radiosurgery (SRS) for the treatment of 15 cases of cerebral arteriovenous malformations (AVMs). Between 2002 and 2009, of the 25 patients who had SRS for the treatment of cerebral AVM, 15 patients (6 men, 9 women) taken a digital subtraction angiography (DSA) over 12 months after SRS were included. We retrospectively evaluated the size, location, hemorrhage of nidus, angiographic changes on follow-up on the MR angiography and DSA, and clinical complications during follow-up periods. At a median follow-up of 24 months (range 12-89), complete obliteration of nidus was observed in all patients (100%) while residual draining veins was observed in 3 patients (20%). There was no clinical complication during the follow-up period except seizure in 1 patient. The mean nidus volume was 4.7cc (0.5~11.7 cc, SD 3.7 cc). The locations of nidus were in cerebral hemisphere in 11 patients, cerebellum in 2 patients, basal ganglia in 1 patient, and pons in 1 patient respectively. 9 cases were hemorrhagic, and 6 cases were non-hemorrhagic AVMs. The SRS with LINAC is a safe and effective treatment for cerebral AVMs when the follow up period is over 4 years. However, it is recommended to continue to follow up until the draining vein on arterial phase of follow up DSA disappears completely.

Development of Birdcage Resonator for Various Absorption Regions at 3T (3T MRI에서 흡수영역의 변화에 따른 Birdcage Resonator의 개발)

  • 이정우;최보영;윤성익;이형구;서태석;허순녕
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.54-58
    • /
    • 2004
  • The aim of this study was to develop special birdcage resonators for small objects including the human wrist, hand and small animals, using 3T MRI/MRS. Before substantial development, different types of parameters were arranged, based on theoretical analysis, through lumped element transmission line theory. The primary analysis was peformed with a network analyzer (HP 4195A) and the final experimental analysis was carried out with 3T MRI (Medinus, Korea). The manufactured birdcage resonator is typically composed of 12-element structures to which a low-pass filter is fundamentally applied. The diameter and length of each element of the birdcage resonator were as follows: (1) diameter 12 cm, length of element 22 cm, (2) diameter 15 cm, length of element 22 cm, and (2) diameter 17 cm, length of element 25 cm. Copper tape with a width of 1 cm was used for the coils. MRI acquisition parameters were TR=500 ms, TE=17 ms, and Ave=2 for T1-WT images, and TR=4,000 ms, TE=96 ms, and Ave=2 for T2-WT images. The ratio of the samples diameter to the birdcage resonators diameter was approximately 55%, 63% and 70%, respectively, for the three elements. This study determined that the best image quality and S/N ratio were obtained when the ratio of the object's diameter was approximately 50∼80%. A general theoretical analysis of the birdcage coil differs in many respects from the experimental results which were influenced by many factors that were not considering when the general theoretical analysis of the birdcage coil was peformed. The induced resistance may be considered as part of the resistive loss if the quantitative value can be determined using a radiation resistance approach.

  • PDF

Difference of fMRI between the Tickling and Sensory Stimulation Using 3.0 Tesla MRI (3.0T 자기공명영상장치를 이용한 사람의 간지럼자극과 감각중추 자극의 활성화 차이)

  • Khang, Hyun-Soo;Lim, Ki-Seon;Han, Dong-Kyoon
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.286-294
    • /
    • 2010
  • This study was performed to identify the cerebral network associated with sensation through the tickling stimulation, which is distinctive from the rest of other networks processing normal stimulation and to investigate the difference of laughing mechanism which is closely related to tickling using functional MRI(fMRI). A 16 healthy volunteers (mean age: 28.9) on a 3.0T MR scanner during two sensation conditions. Counterbalanced stimulus were presented across the participants, and the stimulation was used block design. Acquired data was analyzed by the statistical parametric mapping (SPM 99). Subject and group analysis was performed. Individual analysis showed the activation of somatic sensation area in both tasks and the tickling sensation test showed more activated area in the Wernicke's area(BA40) compared to the normal sensation. The group analysis result shows that under normal stimulations, both sides of somatosensory cortices(BA 1,2 and 3) were activated and under tickling stimulation, not only the cortices but also those huge activation on thalamus, cingulate gyrus and insular lobe were detected. When the tickling was stopped, significant activations were shown in right cingulate gyrus, left MFG area and left insular lobe. A cerebral area responsible for recognizing tickling sensation was examined and the primitive stimulation such as tickling is much closely related to laugh, which is an important factor for various social activities.

Study on the Correlation between the Change in SAR and Temperature of the Human Head by use Dental Implant on 3.0T Brain MRI : Using the XFDTD program (3.0T Brain MRI 검사 시 치아임플란트 시술 유무와 인체의 SAR, 체온 변화와의 상관관계에 관한 연구 : XFDTD 프로그램을 이용)

  • Choe, Dea-yeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.139-146
    • /
    • 2017
  • At the Brain MRI examination, RF Pulse are irradiated on the human head in order to acquire MR images. At this time, a considerable part of the irradiated RF Pulse energy is absorbed in our body and the temperature of the human head will rise depending on the degree of exposure, so it will affect the human head. Even if the same RF Pulse energy is given, if the metal is inserted in the human head, the conductivity of the human head is greatly increased by the metal, so the SAR value increases and the temperature also rises. Therefore, we started this research with the question as to whether there is difference between the change in SAR value and temperature displayed on the head of the human according to use or not of the dental implant. Experiments were using the XFDTD program on a 128 MHz RF Pulse frequency by a 3.0 tesla MRI. We can see that both are increasing that the average value of SAR and temperature that absorbed by the human head model used the dental implant. In addition, the average maximum SAR value and the maximum temperature rise in the brain part are shown below the international safety standard value but the influence can not be ignored because of the result may change according to the increase in the number of dental implant. And as future tasks. we need to the simulation of temperature rise and SAR due to an increase in the number of implants and volumes of teeth, dental implant material.

Lumbar Herniated Disc Resorption of 78 Patients after Korean Medicine Treatment (요추 추간판 탈출증 환자 78명의 한방치료 후 디스크 재흡수 증례 보고)

  • Jung, Bum-Hwan;Jo, Joo-Hyun;Yoon, Yong-Il;Park, Sang-won;Kim, Sung-Moon;Go, Ung;Jung, Jin-soo;Kim, Jung-Hoon;Huh, Suk-Won;Kim, Ji-Won;Kim, Moon-Hwi
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.26 no.1
    • /
    • pp.87-93
    • /
    • 2016
  • Objectives To analyze the resorption of herniated lumbar intervertebral disc on MRI in patients who were treated with Korean Medicine. Methods 78 patients with lumbar disc herniation were included, 47 males and 32 females. Patients' diagnosis was based on magnetic resonance imaging (MRI). All of the patients were only treated with Korean Medicine for 6 months treatment, and underwent MRI examination twice, pre-treatment and post-treatment. MR images were assessed by reduction in diameter of T2-weighted image between pre-treatment and post-treatment, and analyzed by differences in sex, age and disc type. Results 91.2% (71 people) of total patients had extrusion type. Korean medicine treatment reduced lumbar disc herniation diameter of all the patients from 7.11 mm to 3.67 mm on average (p<0.001). The reduction of diameter in the male group was 3.52 mm on average. The reduction of diameter in the female group was 3.32 mm on average. The reduction of diameter was 3.28 mm in the group below age 29, 3.88 mm in the 30~39 age group, 3.39 mm in the 40~49 age group, and 2.71 mm in the above 50 age group on average. Conclusions The MRI results suggest that lumbar herniated disc can resorb with Korean Medicine treatment. The likelihood of lumbar disc resorption was higher at extrusion type. but there was not a significant difference between the sexes and between ages.

Classification of a Volumetric MRI Using Gibbs Distributions and a Line Model (깁스분포와 라인모델을 이용한 3차원 자기공명영상의 분류)

  • Junchul Chun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.58-66
    • /
    • 1998
  • Purpose : This paper introduces a new three dimensional magnetic Resonance Image classification which is based on Mar kov Random Field-Gibbs Random Field with a line model. Material and Methods : The performance of the Gibbs Classifier over a statistically heterogeneous image can be improved if the local stationary regions in the image are disassociated from each other through the mechanism of the interaction parameters defined at the local neighborhood level. This usually involves the construction of a line model for the image. In this paper we construct a line model for multisignature images based on the differential of the image which can provide an a priori estimate of the unobservable line field, which may lie in regions with significantly different statistics. the line model estimated from the original image data can in turn be used to alter the values of the interaction parameters of the Gibbs Classifier. Results : MRF-Gibbs classifier for volumetric MR images is developed under the condition that the domain of the image classification is $E^{3}$ space rather thatn the conventional $E^{2}$ space. Compared to context free classification, MRF-Gibbs classifier performed better in homogeneous and along boundaries since contextual information is used during the classification. Conclusion : We construct a line model for multisignature, multidimensional image and derive the interaction parameter for determining the energy function of MRF-Gibbs classifier.

  • PDF

The Clinical Usefulness of Tc-99m ECD Brain SPECT in Acute Measles Encephalitis (홍역 후 발생된 급성 뇌염 진단시 Tc-99m ECD 뇌혈류 SPECT의 임상적 유용성)

  • Lim, Seok-Tae;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.229-234
    • /
    • 2003
  • Purpose: Since the prognosis of measles encephalitis is poor, early diagnosis and proper management are very important to improve clinical outcomes. We compared Tc-99m ECD brain SPECT (SPECT) with MR imaging (MRI) for the detection of acute measles encephalitis. Materials and Methods: Eleven patients(M : F=4 : 7, age range 18 months-14 yrs) with acute measles encephalitis were enrolled in this studies. All of them underwent both MRI and SPECT. The results of SPECT were scored from 0 (normal) to 3 (most severe defect) according to perfusion state. We compared two image modalities for the detection of brain abnormality in acute measles encephalitis. Results: Seven of 11 patients (63.6%) revealed high signal intensity in the white matter on T2WI of MRI, on the other hand all patients (100%) showed hypoperfusion on SPECT. Severe perfusion deficits above score 2 were located with decreasing frequencies in the frontal lobe (81.8%), temporal lobe (72.7%), occipital lobe (27.3%), basal ganglia (27.3%), and parietal lobe (9.1%). Conclusion: We conclude that SPECT is more useful than MRI for the detection of brain involvement in patients with acute measles encephalitis.

Cloning and Sequencing of the pelCl Gene Encoding Pectate Lyase of Erwinia carotovora subsp. carotovora LY34 (Erwinia carotovora subsp. carotovora LY34에서 pelCI 유전자 클로닝)

  • Lim, Sun-Tech;Park, Yong-Woo;Yun, Han-Dae
    • Applied Biological Chemistry
    • /
    • v.40 no.5
    • /
    • pp.380-387
    • /
    • 1997
  • Phytopathogenic Erwinia carotovora subsp. carotovora (Ecc) LY34 causes plant tissue maceration by secretion of pectinolytic enzymes such as pectate Iyase (PL) existed as multiple isoenzyme form. Genomic DNA from Ecc LY34 was digested with Sau3Al and ligated into the BamHI site of pBluescript ll $SK^+$. Among them, a clone hydrolyzing polypectate was selected and its DNA was digested with BamHI. Through the subsequent subcloning the resulting 3.1 kb fragment, corresponding to a peICI, was subcloned into pLYPA 100. The structural organization of a peICI gene encoding a 374 amino acid residues consists of an open reading frame (ORF) of 1,122 bp commencing with a ATG start codon and followed by a TAA stop codon. PeICI contained a typical prokaryotic signal peptide of 22-amino acid. Since the deduced amino acid sequences of PeICl protein was very similar to those of PelIII of Erwinia carotovora subsp. carotovora, and to those of Pel3 of Erwinia carotovora subsp. atroseptica, and to those of PeIC of Erwinia carotovora subsp. carotovora, it belong to the same family PLbc group. The 374-amino acld PeICI had a calculated Mr of 40,507 and pI of 7.60.

  • PDF

Feasibility of Spin-Echo Echo-Planar Imaging MR Elastography in Livers of Children and Young Adults

  • Kim, Jin Kyem;Yoon, Haesung;Lee, Mi-Jung;Kim, Myung-Joon;Han, Kyunghwa;Koh, Hong;Kim, Seung;Han, Seok Joo;Shin, Hyun Joo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.3
    • /
    • pp.251-258
    • /
    • 2019
  • Purpose: To assess the feasibility of the use of spin-echo echo-planar imaging (SE-EPI) magnetic resonance elastography (MRE) in livers of children and young adults. Materials and Methods: Patients (${\leq}20$ years old) who underwent 3T SE-EPI MRE were included retrospectively. Subjects were divided into three groups according to the purpose of the liver MRI: suspicion of fatty liver or focal fat deposition in the liver (FAT group), liver fibrosis after receiving a Kasai operation from biliary atresia (BA group), and hepatic iron deposition after receiving chemotherapy or transfusions (IRON group). Technical failure of MRE was defined when a stiffness map showed no pixel value with a confidence index higher than 95%, and the patients were divided as success and failure groups accordingly. Clinical findings including age, gender, weight, height, and body mass index and magnetic resonance imaging results including proton density fat fraction (PDFF), $T2^*$, and MRE values were assessed. Factors affecting failure of MRE were evaluated and the image quality in wave propagation image and stiffness map was evaluated using the appropriate scores. Results: Among total 240 patients (median 15 years, 211 patients in the FAT, 21 patients in the BA, and 8 patients in the IRON groups), technical failure was noted in six patients in the IRON group (6/8 patients, 75%), while there were no failures noted in the FAT and BA groups. These six patients had $T2^*$ values ranging from 0.9 to 3.8 ms. The image quality scores were not significantly different between the FAT and BA groups (P > 0.999), while the scores were significantly lower in the IRON group (P < 0.001). Conclusion: The 3T SE-EPI MRE in children and young adults had a high technical success rate. The technical failure was occurred in children with decreased $T2^*$ value (${\leq}3.8ms$) from iron deposition.