• Title/Summary/Keyword: MR16

Search Result 334, Processing Time 0.028 seconds

The Effects of a MR Torso Coil on CT Attenuation Correction for PET (PET/CT 검사에 있어서 MR Torso Coil의 CT 감쇄보정에 대한 영향 평가)

  • Lee, Seung Jae;Bahn, Young Kag;Oh, Shin Hyun;Gang, Cheon-Gu;Lim, Han Sang;Kim, Jae Sam;Lee, Chang Ho;Seo, Soo-Hyun;Park, Yong Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.81-86
    • /
    • 2012
  • Purpose : Combined MR/PET scanners that use the MRI for PET AC face the challenge of absent surface coils in MR images and thus cannot directly account for attenuation in the coils. To make up for the weak point of MR attenuation correction, Three Modality System (PET/CT +MR) were used in Severance hospital. The goal of this work was to investigate the effects of MR Torso Coil on CT attenuation correction for PET. Materials and Methods : PET artifacts were evaluated when the MR Torso Coil was present of CTAC data with changing various kV and mA in uniformity water phantom and 1994 NEMA cylinderical phantom. They evaluated and compared the following two scenarios: (1) The uniform cylinder phantom and the MR Torso Coil scanned and reconstructed using CT-AC; (2) 1994 NEMA cylinderical phantom and the MR Torso Coil scanned and reconstructed using CT-AC. Results : Streak artifacts were present in CT images containing the MR Torso Coil due to metal components. These artifacts persisted after the CT images were converted for PET-AC. CT scans tended to over-estimate the linear attenuation coefficient when the kV and mA is increasing of the metal components when using conventional methods for converting from CT number. Conclusion : The presence of MR coils during PET/CT scanning can cause subtle artifacts and potentially important quantification errors. Alternative CT techniques that mitigate artifacts should be used to improve AC accuracy. When possible, removing segments of an MR coil prior to the PET/CT exam is recommended. Further, MR coils could be redesigned to reduce artifacts by rearranging placement of the most attenuating materials.

  • PDF

The Growth and EPA Synthesis of Shewanella oneidensis MR-1 and Expectation of EPA Biosynthetic Pathway

  • Jeong, Young-Su;Song, Sang-Kyu;Lee, Su-Jin;Hur, Byung-Ki
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.2
    • /
    • pp.127-133
    • /
    • 2006
  • Shewanella oneidensis MR-1 has the ability to inhale certain metals and chemical compounds and exhale these materials in an altered state; as a result, this microorganism has been widely applied in bioremediation protocols. However, the relevant characteristics of cell growth and biosynthesis of PuFAs have yet to be thoroughly investigated. Therefore, in this study, we have attempted to characterize the growth and fatty acid profiles of S. oneidensis MR-1 under a variety of temperature conditions. The fastest growth of S. oneidensis MR-1 was observed at $30^{\circ}C$, with a specific growth rate and doubling time of $0.6885h^{-1}\;and\;1.007 h$. The maximum cell mass of this microorganism was elicited at a temperature of $4^{\circ}C$. The eicosapentaenoic acid (EPA) synthesis of S. oneidensis MR-1 was evaluated under these different culture temperatures. S. oneidensis MR-1 was found not to synthesize EPA at temperatures in excess of $30^{\circ}C$, but was shown to synthesize EPA at temperatures below $30^{\circ}C$. The EPA content was found to increase with decreases in temperature. We then evaluated the EPA biosynthetic pathway, using a phylogenetic tree predicted on 16s rRNA sequences, and the homology of ORFs between S. oneidensis MR-1 and Shewanella putrefaciens SCRC-2738, which is known to harbor a polyketide synthase (PKS)-like module. The phylogenetic tree revealed that MR-1 was very closely related to both Moritella sp., which is known to synthesize DHA via a PKS-like pathway, and S. putrefaciens, which has been reported to synthesize EPA via an identical pathway. The homology between the PKS-like module of S. putrefaciens SCRC-2738 and the entire genome of S. oneidensis MR-1 was also analyzed, in order to mine the genes associated with the PKS-like pathway in S. oneidensis MR-1. A putative PKS-like module for EPA biosynthesis was verified by this analysis, and was also corroborated by the experimental finding that S. oneidensis MR-1 was able to synthesize EPA without the expression of $dihomo-{\gamma}-linoleic$ acid (DGLA) and arachidonic acid (AA) formed during EPA synthesis via the FAS pathway.

A new approach to deal with sensor errors in structural controls with MR damper

  • Wang, Han;Li, Luyu;Song, Gangbing;Dabney, James B.;Harman, Thomas L.
    • Smart Structures and Systems
    • /
    • v.16 no.2
    • /
    • pp.329-345
    • /
    • 2015
  • As commonly known, sensor errors and faulty signals may potentially lead structures in vibration to catastrophic failures. This paper presents a new approach to deal with sensor errors/faults in vibration control of structures by using the Fault detection and isolation (FDI) technique. To demonstrate the effectiveness of the approach, a space truss structure with semi-active devices such as Magneto-Rheological (MR) damper is used as an example. To address the problem, a Linear Matrix Inequality (LMI) based fixed-order $H_{\infty}$ FDI filter is introduced and designed. Modeling errors are treated as uncertainties in the FDI filter design to verify the robustness of the proposed FDI filter. Furthermore, an innovative Fuzzy Fault Tolerant Controller (FFTC) has been developed for this space truss structure model to preserve the pre-specified performance in the presence of sensor errors or faults. Simulation results have demonstrated that the proposed FDI filter is capable of detecting and isolating sensor errors/faults and actuator faults e.g., accelerometers and MR dampers, and the proposed FFTC can maintain the structural vibration suppression in faulty conditions.

Isolation and Characterization of a Marine Bacterium, Pseudomonas sp. YJ-1 with Anti-Methicillin Resistant Staphylococcus aureus Activity (항 Methicillin Resistant Staphylococcus aureus 활성을 가지는 해양미생물 Pseudomonas sp. YJ-1의 분리와 특성)

  • Woo, Ye-Ju;Jeong, Seong-Yun
    • Korean Journal of Environmental Biology
    • /
    • v.35 no.4
    • /
    • pp.694-705
    • /
    • 2017
  • The aim of this study was to isolate and identify marine bacterium with anti-methicillin-resistant Staphylococcus aureus (MRSA) activity, and to purify the anti-MRSA compound, as well as to determine its activity and synergistic effects. Among the marine bacteria isolated in this study, the YJ-1 isolate had the strongest anti-MRSA activity. The YJ-1 isolate was identified on the basis of its biochemical characteristics and an analysis of 16S rRNA gene sequences. The YJ-1 isolate showed over 99.2% homology with Pseudomonas stutzeri, and was designated as a Pseudomonas sp. YJ-1. The optimal culture conditions were $25^{\circ}C$ and initial pH 7.0. For the purification of the anti-MRSA compounds, the YJ-1 was cultured in Pa PES-II medium, and the culture filtrates were extracted by ethyl acetate, hexane, and 80% MeOH. The 80% MeOH fraction was separated by a $C_{18}$ ODS column, silica gel chromatography and a reverse phase HPLC, to yield three anti-MRSA agents, the MR1, MR2, and MR3 compounds. When the MR1 compound of $250{\mu}g\;mL^{-1}$ concentration was applied to the MRSA cells, over 95% of bacterial cells was killed within 48 hr. Compared with vancomycin and ampicillin, the MR1 compound showed significant anti-MRSA activity. In addition, the anti-MRSA activity was increased by dose and time dependent manners. Furthermore, the combination of an MR1 compound with vancomycin produced a more rapid decrease in the MRSA cells than did the MR1 compound alone. Taken together, our results suggest that the Pseudomonas sp. YJ-1 and its anti-MRSA compounds could be employed as a natural antibacterial agent in MRSA infections.

MR-based Partial Volume Correction Using Hoffman Brain Phantom Data and Clinical Application (자기공명영상을 이용한 양전자방출단층촬영의 부분용적효과 보정 및 임상적용)

  • 김동현;이상호;정해조;윤미진;이종두;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.203-210
    • /
    • 2003
  • PET (positron emission tomography) permits the investigation of physiological and biochemical processes in vivo. The accuracy of quantifying PET data is affected by its finite spatial resolution, which causes partial volume effects. In this study, we developed a method for partial volume correction using Hoffman phantom PET and MR data, and applied various FWHM (full width at half maximum) levels. We also applied this method to PET images of normal controls and tested for the possibility of clinical application. $^{18}$ F-PET Hoffman phantom images were co-registered to MR slices. The gray matter and white matter regions were then segmented into binary images. Each binary image was convolved by 4, 8, 12, 16 mm FWHM levels. These convolved images of gray and white matter were merged corresponding to the same level of FWHM. The original PET images were then divided by the convolved binary images voxel-by-voxel. These corrected PET images were multiplied by binary images. The corrected PET images were evaluated by analyzing regions of interests, which were drawn on the gray and white matter regions of the original MR image slices. We calculated the ratio of white to gray matter. We also applied this method to the PET images of normal controls. On analyzing the corrected PET images of Hoffman phantom, the ratios of the corrected images increased more than that of the uncorrected images. With the normal controls, the ratio of the corrected images increased more than that of the uncorrected images. The ratio increase of the corrected PET images was lower than that of the corrected phantom PET images. In conclusion, the method developed for partial volume correction in PET data may be clinically applied, although further study may be required for optimal correction.

  • PDF

Normal MR Spectroscopic Findings of the Cerebellum and Pons: Comparison of the Results between Intra-Unit and Inter-Unit Studies (소뇌와 뇌교의 정상 자기공명분광 소견: 같은 장비내 및 다른 장비간의 결과 비교)

  • 최준일;장기현;송인찬;도강현;이준우
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.2
    • /
    • pp.123-129
    • /
    • 2001
  • Purpose: The purposes of this study are to evaluate normal MR spectroscopy (MRS) data of the cerebellum and pons, and to evaluate intra-unit and inter-unit differences of the results. Materials and methods: Nine normal volunteers (mean age 23 years) were studied with two 1.5 Tesla MR units (A and B units). A total of four sessions of MRS study were performed with two sessions in ea.ch MR unit in each volunteer. In each session, MRS data were obtained from bilateral cerebellar hemisphere and pons. MRS was performed using spin-echo single voxel technique with repetition time of 2000 ms, echo time of 288ms and 128 averagings. Voxel size was $2{\;}{\times}{\;}2{\;}{\times}{\;}1.5{\;}cm$ in the cerebellum and $1.5{\;}{\times}{\;}1.5{\;}{\times}{\;}1.5{\;}cm$ in the pons. Metabolite ratios of NAA/Cho, NAAcCr, NAAc(Cho+Cr) and Cr/Cho (both peak heights and the peak areas) were compared among the results of four sessions of MRS for evaluation of intra-unit and inter-unit differences. Results: In the cerebellum, mean (SO values of peak height NAA/Cho, NAA/Cr, NAA/(Cho+Cr) and Cr/Cho ratios obtained in the first session of A unit were $1.08{\pm}O.16,{\;}1.44{\pm}O.286,{\;}0.61{\pm}O.09{\;}and{\;}O.76{\pm}0.13$, respectively. Comparing with the results of the second session, intra-unit differences were 3-7%. In B unit intra-unit differences were 1-9%, except for 22% of Cr/Cho ratio. Inter-unit differences between A and B units were 1-26%. In the pons, mean ISD values of peak height NANCho, NANCr, NANICho + Cr) and Cr/Cho ratios obtained in the first session of A unit were $1.51{\pm}O.35,{\;}3.35{\pm}O.78,{\;}1.02{\pm}0.16{\;}and{\;}0.47{\pm}O.14$, respectively. Mean NAAfCho, NANCr and NAAI(Cho+ Cr} ratios of the pons were significantly higher than those of the cerebellum. Intra-unit differences were 2-21 % in A unit and 4-18 % in B unit. Inter-unit differences between A and B units were 1-18%. The mean values obtained by using peak area were generally higher and wider in range than those of peak height in both units. Conclusion: Mean NAAfCho, NAAlCr and NAAf(Cho+Cr) ratios of the cerebellum were significanHy lower than those of the pons. Intra-unit differences of most metabolites ratios were generally not significant, whereas inter-unit differences were greater than intra-unit differences in more metabolite ratios. Therefore, normal MRS data of the cerebellum and the pons should be obtained in every MR unit, before MRS applications in the diseases of the cerebellum and the pons.

  • PDF

Diagnostic Accuracy of PET and MR for Detecting Liver Metastasis from Colorectal Cancer (대장-직장암의 간전이에서 FDG PET과 MR의 진단 성능)

  • Park, Eun-Kyung;Kang, Won-Jun;Eo, Jae-Seon;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.5
    • /
    • pp.249-256
    • /
    • 2006
  • Purpose: Although computed tomography (CT) is widely used for diagnosing liver metastasis from colorectal cancer, diagnostic accuracy of CT is not satisfactory. Magnetic resonance (MR) imaging and F-18 FDG PET has been reported to be superior to CT. However, studies on direct comparison of PET and MR are scarce. We compared the diagnostic accuracy of FDG PET and MR in detecting liver metastasis from colorectal cancer. Materials and Methods: Among 363 colorectal cancer patients who underwent F-18 FDG PET (ECAT, Siemens-CTI, Knoxville; Gemini, Philips, Milpitas, U.S.), 26 patients (M:F=17:9, age=$62{\pm}11$) underwent MR to evaluate suspicious metastatic liver lesions. Finally, 35 liver lesions detected by CT from 26 patients were enrolled for analysis. PET and MR results were compared with pathologic reports, clinical findings or follow-up results. Results: Of the 35 lesions, 18 lesions (51.4%) were diagnosed as liver metastases, while remaining 17 (48.6%) as benign. The sensitivity and the specificity of PET were 94.4% and 94.1%, respectively, compared to 100% and 82.4% for MR. MR and PET was concordant in 30 lesions (85.7%: 17 metastatic (94.4%) and 13 benign (76.5%) lesions. ROC curve analysis revealed maximal SUV of 3.1 as the optimum standard in differentiating metastatic from benign liver lesions (AUC=0.897, p<0.001, sensitivity 83.3%, specificity 94.1%). For small lesions less than 1 cm ln diameter (n=20), diagnostic accuracy of PET was comparable to that of MR. Conclusion: F-18 FDG PET showed good diagnostic performance in detecting liver metastasis from colorectal cancer, which was comparable to MR.

Design and Optimization of 4-Channel SENSE Head Coil

  • 오정민;김용권;류연철;오창현
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.16-16
    • /
    • 2003
  • Purpose: Recently, a major interesting method of fast MR imaging is sensitivity encoding (SENSE) using arrays of multiple receiver coils. In this study, we have designed and implemented a 4-channel head array coil and optimized the structure and arrangement of the coil to improve the performance.

  • PDF

The Role of Dynamic Contrast Enhanced MR Mammography in Differentiation between Benign and Malignant Breast Lesions

  • 한송이;차은숙;정상설;김학희;변재영;이재문
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.135-135
    • /
    • 2002
  • Purpose: To assess diagnostic accuracy of dynamic contrast enhanced MR mammography in differentiating between benign and malignant lesions. Materials and methods: Ninety-three patients with suspicious mammographic, sonographic or palpable findings underwent pre- or postoperative contrast-enhanced MR imaging of breast using three dimensional fast low-angle shot (3D FLASH) sequence (16/4 msec[repetition time / echo time], 20 flip angle, 3mm slice thickness with no slice gap, 256 by 256 in-plane matrix) covering whole breasts. T1 weighted images were obtained before and after bolus administration of gadopentetate dimeglumine (0.15 mmol/kg). Subtraction images and time-signal intensity curves of region of interest were obtained sequentially and correlated with pathologic diagnoses of lesions.

  • PDF

A Study on Maintenance Rule for the Maintenance Effectiveness Monitoring (정비 효율성 감시를 위한 정비규정에 관한 연구)

  • 황미정;김길유
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.110-116
    • /
    • 2001
  • The objective of the Maintenance Rule (MR) is to require monitoring of the overall continuing effectiveness of licensee maintenance programs to ensure that the safety related and certain nonsafety-related SSCs are capable of performing their intended functions. In Korea, as risk informed applications and regulation become active, the necessity of Performance Based Regulation (PBR) has increased. The objective of this article is to study the effectiveness of MR based on performance and feasibility of MR adoption at Korean Nuclear Power Plants (NPPs) for effective maintenance and regulation.

  • PDF