• Title/Summary/Keyword: MR ratio

Search Result 447, Processing Time 0.025 seconds

Development of PC Based Signal Postprocessing System in MR Spectroscopy: Normal Brain Spectrum in 1.5T MR Spectroscopy (PC를 이용한 자기공명분광 신호처리분석 시스템 개발: 1.5T MR Spectroscopy에서의 정상인 뇌 분광 신호)

  • 백문영;강원석;이현용;신운재;은충기
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.128-135
    • /
    • 2000
  • Purpose : The aim of this study is to develope the Magnetic Resonance Spectroscopy(MRS) data processing S/W which plays an important role as a diagnostic tool in clinical field. Materials and methods : Post-processing software of MRS based on graphical user interface(GUI) under windows operating system of personal computer(PC) was developed using MATLAB(Mathwork, U.S.A.). This tool contains many functions to increase the quality of spectrum data such as DC correction, zero filling, line broadening, Gauss-Lorentzian filtering, phase correction, etc. And we obtained the normal human brain $^1H$ MRS data from parietal white matter, basal ganglia and occipital grey matter region using 1.5T Gyroscan ACS-NT R6 (philips, Amsterdam, Netherland) MRS package. The analysis of the MRS peaks were performed by obtaining the ratio of peak area. Results : The peak ratios of NAA/Cr, Cho/Cr, MI/Cr for the different MRS machines have a little different values. But these peak ratios were not significantly different between different echo time MRS peak ratios in the same machine (p<0.05). Conclusion : MRS post-processing S/W based on GUI using PC was developed and applied to the analysis of normal human brain $^1H$ MRS. This independent MRS processing job increases the performance and throughput of patient scan of main console. Finally, we suggest that the database for normal in-yivo human MRS data should be obtained before clinical applications.

  • PDF

Full-scale test of dampers for stay cable vibration mitigation and improvement measures

  • Zhou, Haijun;Xiang, Ning;Huang, Xigui;Sun, Limin;Xing, Feng;Zhou, Rui
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.4
    • /
    • pp.489-506
    • /
    • 2018
  • This paper reported test of full-scale cables attached with four types of dampers: viscous damper, passive Magneto-Rheological (MR) damper, friction damper and High Damping Rubber (HDR) damper. The logarithmic decrements of the cable with attached dampers were calculated from free vibration time history. The efficiency ratios of the mean damping ratios of the tested four dampers to theoretical maximum damping ratio were derived, which was very important for practical damper design and parameter optimization. Non-ideal factors affecting damper performance were discussed based on the test results. The effects of concentrated mass and negative stiffness were discussed in detail and compared theoretically. Approximate formulations were derived and verified using numerical solutions. The critical values for non-dimensional concentrated mass coefficient and negative stiffness were identified. Efficiency ratios were approximately 0.6, 0.6, and 0.3 for the viscous damper, passive MR damper and HDR damper, respectively. The efficiency ratio for the friction damper was between 0-1.0. The effects of concentrated mass and negative stiffness on cable damping were positive as both could increase damping ratio; the concentrated mass was more effective than negative stiffness for higher vibration modes.

Tunnel i unction-Mangnetorsistance in Co-Al-O$_{x}$-NiFe with oxidation conditions of Al thickness

  • Jeon, Dong-Min;Park, Jin-Woo;Suh, Su-Jeong
    • Journal of the Korean institute of surface engineering
    • /
    • v.34 no.5
    • /
    • pp.494-498
    • /
    • 2001
  • Ferromagnets(FM)-Al-$O_{x}$ -Ferromagnets (FM) tunneling junctions were evaluated by changing the fabricating conditions of an Al-X$/_{x}$ layer. The junction composed of a thicker Al-$O_{x}$ shows the low resistance and the stable MR ratio about 16% in a wide range of oxidation time. For the junctions with the thinner Al-$O_{x}$ , they showed a fast increase of the barrier width as an increase of an oxidation time and exhibited a strong bias dependence. As oxidation time increased, the coercivity ($H_{c}$ ) of bottom Co layer increased gradually due to the local oxidation of Co bottom layer at a interface. However, the small formation of Co oxide did not largely influence on the deterioration of MR ratio.

  • PDF

Genetic Algorithm Based Linear Region Extension for Multivariable Monopulse Tracking Systems (다변수 모노펄스 추적 시스템에서 유전 알고리즘 기반 선형구간 확장)

  • Jung, Jinwoo;Kim, Jaesin;Ryu, Young-Jae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.272-278
    • /
    • 2017
  • In this paper, we consider a single-channel amplitude comparison monopulse system(SCACMS). The monopulse ratio curve(MR-C) of the SCACMS can be controlled by an amplitude difference between sum and different signal, a phase difference and the coefficient of the signal processor. We first propose the SCACMS with multiple variables, and then apply a genetic algorithm to optimize the multiple variables in terms of minimizing a root mean square error. The simulation results show that when three variables of the SCACMS are jointly optimized, the linear region of the MR-C can be extended approximately 187 % compared to that of two variables.

A New Sensing and Writing Scheme for MRAM (MRAM을 위한 새로운 데이터 감지 기법과 writing 기법)

  • 고주현;조충현;김대정;민경식;김동명
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.815-818
    • /
    • 2003
  • New sensing and writing schemes for a magneto-resistive random access memory (MRAM) with a twin cell structure are proposed. In order to enhance the cell reliability, a scheme of the low voltage precharge is employed to keep the magneto resistance (MR) ratio constant. Moreover, a common gate amplifier is utilized to provide sufficient voltage signal to the bit line sense amplifiers under the small MR ratio structures. To enhance the writing reliability, a current mode technique with tri-state current drivers is adopted. During write operations, the bit and /bit lines are connected. And 'HIGH' or 'LOW' data is determined in terms of the current direction flowing through the MTJ cell. With the viewpoint of the improved reliability of the cell behavior and sensing margin, HSPICE simulations proved the validity of the proposed schemes.

  • PDF

A Study on the Characteristics of Giant Magneto Resistance using Multi Layers (다층막을 이용한 거대자기저항(GMR)의 특성 연구)

  • Kim, Byeong-Woo;Lee, Young-Seok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.5
    • /
    • pp.113-118
    • /
    • 2008
  • We have developed an integrated giant magneto resistance using not only circuit but also integrating technique with semiconductor for automobile application. It has four elements used for giant magneto resistance sensor. Ni-Fe/Cu multi layers were prepared on a glass substrate by magnetron sputtering. The dependence of magneto resistance on the thickness of the Ni-Fe and Cu layers was investigated. The MR ratio showed a saturated a peak at Cu layer $10{\AA}$, Ni-Fe layer $50{\AA}$, where the MR ratio is about 8.7% at room temperature. By means of Ni-Fe multi film and specific integrating technique, these new giant magneto resistance sensor showed excellent resistance characteristics.

The study of magnetoresistance and magnetic properties in [(CoO/NiO)/NiFe/Cu/NiFe] spin-valve thin films ([(CoO/NiO)/NiFe/Cu/NiFe] spin-valve 박막에서의 자기저항효과와 자기적 특성에 대한 연구)

  • 현준원
    • Electrical & Electronic Materials
    • /
    • v.9 no.10
    • /
    • pp.1060-1065
    • /
    • 1996
  • We have studied the magnetoresistance phenomena on spin valve thin films of antiferromagnetic NiO/CoO. Interlayer coupling oscillates between the antiferrocoupling and ferrocoupling with the variation of Cu thickness. The exchange coupling strength between NiO (antiferromagnetic) and NiFe(ferromagnetic) as a function of NiO texture and interface roughness is investigated by CoO insertion. CoO has significantly higher anisotropy in the (111) plane and interface roughness. It seems that the MR-ratio is increased by CoO inserted films. From the AFM and XRD data, the increase of MR-ratio and exchange field is influenced by the roughness of CoO.

  • PDF

Analysis of Multicarrier DS/DPSK Systems with Single Tone Interference Rejection (단일톤 간섭제거를 위한 다단반송파 DS/DPSK 시스템의 성능분석)

  • 엄종선;김동인
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.4
    • /
    • pp.761-770
    • /
    • 1997
  • Narrowband signals can be treated like a single tone interference at the receiver which demodulates wideband signals spectrum overlaid at the same frequency band. In this paper, the single tone interference is effectively suppressed by the use of a multicarrier DPSK direct-sequence(DS) spread spectrum(SS) with maximal-ratio(MR) combining instead of notch filter, which is hard to implement. A noncoherent DPSK system is considered because it is more realizable and does not require any complicate phase tracking, compared with a single carrier system subject to a constraint system bandwidth, and their performance comparisons are validated through simulation. We also propose a suboptimal-ratio(SR) combining which yields uniform and tight low bound on the performance of the MR combining, and then system parameters re optimized by theoretically evaluating the low bound, since an exact analysis appears intractable.

  • PDF

[ $^1H$ ] Magnetic Resonance Spectroscopy of Primary Central Nervous System Lymphoma (일차성 중추신경 림프종의 수소 자기공명분광법)

  • Kim Yong Sun;Lee Hui Joong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.86-93
    • /
    • 2004
  • Purpose: We evaluated $^1H$ MR spectroscopy improves the preoperative diagnosis of diffuse infiltrative type of primary central nervous system lymphomas. Materials and methods: After review of conventional MR images and medical records, we retrospectively reviewed proton MR spectra in seven patients with primary central nervous system lymphoma diagnosed by means of biopsy. Relative ratio of choline (Cho), N-acetylaspartate (NAA), and lipid-lactate (Lip-Lac) to creatine (Cr) were measured for quantitative analysis. Results: The average ratio of Cho/Cr was $1.80{\pm}0.95$, NAA/Cr was $1.34{\pm}0.41$, and Lip-Lac/Cr was $1.12{\pm}0.16$. All cases of lymphomas showed increased Lip-Lac peak. Two case of mass forming lymphoma showed decreased NAA/Cr significantly, whereas five cases of lymphoma without mass formation showed preserved NAA/Cr. Conclusion : We thought the presence of Lip-Lac peak without significant reduction of NAA on the MR spectroscopy was helpful for diagnosis of diffuse infiltrative type of central nervous system lymphoma.

  • PDF

Performance Analysis of Mobile Multi-hop Relay Uplink System in Multicell Environments (멀티셀 환경에서 Mobile Multi-hop Relay 상향링크 시스템의 성능 분석)

  • Kim, Seung-Yeon;Kim, Se-Jin;Lee, Hyong-Woo;Ryu, Seung-Wan;Cho, Choong-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.4A
    • /
    • pp.394-400
    • /
    • 2010
  • Mobile Multi-hop Relaying (MMR) system can provide increased system capacity of wireless access network by coverage extension and enhanced transmission rate within the Base Station (BS) coverage area. The previous researches for the MMR system with a non-transparent mode Relay Station (RS) do not consider channel selection procedure of Mobile Station (MS), co-channel interference and Multi-hop Relay Base Station (MR-BS) coverage and RS coverage ratio in MMR system. In this paper, we investigate the performance of MMR uplink system in multicell environments with various topologies. The performance is presented in terms of call blocking probability, channel utilization, outage probability and system throughput by varying offered load. It is found that, for certain system parameters, the MMR uplink system achieve the maximum system throughput when MR-BS coverage to RS coverage ratio is 7.