MRI 보어 구경에 따른 검사 시 실효 단면적 분석 (Analysis of Actual Cross-Sectional Area During Scanning According to MRI Bore Size)

  • 정현근;정현도;김성호;전민철;유세종;고현철;조용현
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권6호
    • /
    • pp.219-227
    • /
    • 2020
  • In this study, we tried to quantify the actual cross-sectional area inside the bore when scanning by the MRI system with various bore sizes. To this end, a comparative analysis was conducted by both of blueprint of each MRI equipment and actual measurement in the field. As a result of analysis, ACSA(Actual Cross-Sectional Area) in Ingenia CX, Elition X, uMR 780, Omega, Vida, Lumina, Architect, Premier is recorded as 171230, 232150, 242100, 309332, 230760, 230760, 229380 and 235990 ㎟, respectively ACSA% was 60.6, 60.3, 73.0, 70.0, 60.0, 60.0, 59.6, and 61,3%. In addition, DTB (Distance from Table top to Bore top) recorded 400, 407, 445, 495, 405, 405, 405, 403, and 412 mm. Through this study, it was confirmed that there is a difference between the bore size according to each MRI system and the actual cross-sectional area during MRI scanning. Accordingly, if we consider the internal actual area just not bore size at the clinical site, useful diagnostic images can be obtained in the end with better convenience.

시각자극과 삼음교 자침으로 유발된 성적 흥분의 대뇌 활성화 영상의 비교 : 3 테슬라 기능적 자기공명영상법 (Comparison of Brain Activation Images Associated with Sexual Arousal Induced by Visual Stimulation and SP6 Acupuncture : fMRI at 3 Tesla)

  • 최남길;한재복;장성주
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권2호
    • /
    • pp.183-194
    • /
    • 2009
  • 목 적 : 정상인 여성을 대상으로 기능적 자기공명영상법(functional magnetic resonance imaging : fMRI)을 이용하여 성적 흥분반응과 관련되는 시각자극과 삼음교(SP6, 三陰交) 경혈자극 의한 대뇌 활성화 영역의 차이점을 밝히고, 나아가서는 성적흥분의 기전을 신경해부학적인 측면에서 규명하고자 하였다. 대상 및 방법 : 성기능이 정상적인 오른손잡이 여자 21명(19$\sim$32세 : 평균 22세)을 대상으로 3.0 Tesla MR scanner를 이용하여 fMRI 영상을 얻었다. 성적 흥분을 유도하기 위한 패러다임은 3분간의 에로틱 비디오 시청과 삼음교(SP6)자침에 의한 자극을 주었으며, 자극 전 후에는 각각 1분간의 휴지기를 두었다. 또한 광명혈(GB37) 후방으로 3 cm 위치에 있는 비경혈점에 자극을 주어 경혈(acupoint)과 비경혈(shampoint) 자침에 의한 대뇌의 활성화 양상을 비교하였다. 기능적 자기공명영상의 획득은 AC-PC line을 기준으로 20개의 횡단면으로부터 총 2,000개의 기초영상을 얻었으며, SPM99 프로그램을 이용하여 평균 활성화 영상을 얻었다. 결 과 : 삼음교 경혈과 비경혈의 침자극에 의한 비교실험에서 경혈은 비경혈에 비하여 대뇌 신피질에서 평균 5배, 변연계에서 2배 높은 활성화도를 보였다. 비경혈 자극시에 간뇌의 HTHL, 기저핵의 GLO, AMYG, 그리고 두정엽의 SMG 등에서는 활성화 신호가 관찰되지 않았다. 성적흥분과 관련된 대뇌의 해부학적인 영역을 시각자극과 삼음교 경혈자극 별로 비교 분석한 결과, 두 자극간의 평균 활성화율(activation ratio)은 신피질과 변연계 모두에서 유의한 차이가 없었다(p < 0.05). 반면 평균 활성화도(activity)는 신피질의 경우에는 두 자극간에 유의한 차이를 보이지 않았으나, 변연계의 경우에는 경혈 자극시에 유의하게 더 높은 활성화도를 보였다(p < 0.05). 결 론 : 기능적 자기공명영상법을 이용하여 성적흥분과 관련된 시각자극과 경혈 침술자극에 의하여 유발된 대뇌 활성화 양상의 차이점과 신경해부학적 기전의 차이점을 규명할 수 있었으며, 이러한 결과를 바탕으로 향후 한방의 경혈, 경락 이론을 과학적인 측면에서 입증할 수 있을 것으로 기대한다.

  • PDF

Comparative Investigation of Single Voxel Magnetic Resonance Spectroscopy and Dynamic Contrast Enhancement MR Imaging in Differentiation of Benign and Malignant Breast Lesions in a Sample of Iranian Women

  • Faeghi, Fariborz;Baniasadipour, Banafsheh;Jalalshokouhi, Jalal
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권18호
    • /
    • pp.8335-8338
    • /
    • 2016
  • Purpose: To make a comparison of single voxel magnetic resonance spectroscopy (SV-MRS) and dynamic contrast enhancement (DCE) MRI for differentiation of benign and malignant breast lesions in a sample of Iranian women. Materials and Methods: A total of 30 women with abnormal breast lesions detected in mammography, ultrasound, or clinical breast exam were examined with DCE and SV-MRS. tCho (total choline) resonance in MRS spectra was qualitatively evaluated and detection of a visible tCho peak at 3.2 ppm was defined as a positive finding for malignancy. Different types of DCE curves were persistent (type 1), plateau (type 2), and washout (type 3). At first, lesions were classified according to choline findings and types of DCE curve, finally being compared to pathological results as the standard reference. Results: this study included 19 patients with malignant lesions and 11 patients with benign ones. While 63.6 % of benign lesions (7 of 11) showed type 1 DCE curves and 36.4% (4 of 11) showed type 2, 57.9% (11of 19) of malignant lesions were type 3 and 42.1% (8 of 19) type 2. Choline peaks were detected in 18 of 19 malignant lesions and in 3 of 11 benign counterparts. 1 malignant and 8 benign cases did not show any visible resonance at 3.2 ppm so SV-MRS featured 94.7% sensitivity, 72.7 % specificity and 86.7% accuracy.Conclusions: The present findings indicate that a combined approach using MRS and DCE MRI can improve the specificity of MRI for differentiation of benign and malignant breast lesions.

뇌의 확산강조 영상에서 b-value의 변화에 따른 신호강도, 현성확산계수에 관한 비교 분석 : 확산강조 에코평면영상($T_2^*$ 및 FLAIR)기법 중심으로 (Comparative Analysis of Signal Intensity and Apparent Diffusion Coefficient at Varying b-values in the Brain : Diffusion Weighted-Echo Planar Image ($T_2^*$ and FLAIR) Sequence)

  • 오종갑;임중열
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권3호
    • /
    • pp.313-323
    • /
    • 2009
  • 확산강조영상 (diffusion weighted image, DWI)은 급성 뇌경색, 뇌종양, 뇌백질 질환, 뇌 막질의 확산 정도 등 여러 뇌질환의 진단을 획기적으로 향상시켰으며 그 활용도가 증가하고 있다. 본 연구는 $10{\sim}60$대 환자들의 뇌를 대상으로 두 기법간의 신호강도, 현성확산계수의 평균치를 측정하였다. 그 결과, 확산강조영상에서의 신호강도 평균값은 편도체부 (amygdala)가 가장 높고, 뇌척수액(cerebrospinal fluid)에서 가장 낮았다. 현성확산계수의 평균값은 뇌척수액이 높고, 교뇌 (pons)가 낮게 측정되었다. 확산강조 신호강도와 현성확산계수의 평균값은 $T_2^*$-DW-EPI 기법이 FLAIR-DW-EPI 기법보다 높고, b-value의 변화에 따른 평균값은 두 기법의 b-value에 모두 반비례하였다. 또한 뇌경색환자의 뇌의 시간 경과에 따른 분석결과, 초급성뇌경색 환자의 일반적인 MR 영상에서는 병변부분이 명확하지 않았으나 확산강조영상에서는 고신호강도로 나타났다. 출혈성 뇌경색, 급성 뇌경색 등 여러질환별로 분석한 결과 그 두 기법의 특성에 따라 신호강도의 값이 차이가 클수록 현성확산계수는 낮게 나타났다. 결론적으로 뇌 질환이 자주 발생되는 부위와 뇌 질환의 확산강조 신호강도 및 현성확산계수 값은 b-value의 변환과 영상기법에 따라 각각 다르게 나타났다. 이러한 정량적인 결과를 바탕으로 보다 안정적인 기법과 적절한 b-value 값을 이용하여 검사를 한다면 여러 뇌의 질환 및 병변 등을 발견, 판독하는 것뿐만 아니라 정상부위나 질환에 따른 기법별 신호의 인지를 통한 정확한 질병 진단과 치료에 중요한 의미가 있다고 사료된다.

  • PDF

Analysis of Image Distortion on Magnetic Resonance Diffusion Weighted Imaging

  • Cho, Ah Rang;Lee, Hae Kag;Yoo, Heung Joon;Park, Cheol-Soo
    • Journal of Magnetics
    • /
    • 제20권4호
    • /
    • pp.381-386
    • /
    • 2015
  • The purpose of this study is to improve diagnostic efficiency of clinical study by setting up guidelines for more precise examination with a comparative analysis of signal intensity and image distortion depending on the location of X axial of object when performing magnetic resonance diffusion weighted imaging (MR DWI) examination. We arranged the self-produced phantom with a 45 mm of interval from the core of 44 regent bottles that have a 16 mm of external diameter and 55 mm of height, and were placed in 4 rows and 11 columns in an acrylic box. We also filled up water and margarine to portrait the fat. We used 3T Skyra and 18 Channel Body array coil. We also obtained the coronal image with the direction of RL (right to left) by using scan slice thinkness 3 mm, slice gap: 0mm, field of view (FOV): $450{\times}450mm^2$, repetition time (TR): 5000 ms, echo time (TE): 73/118 ms, Matrix: $126{\times}126$, slice number: 15, scan time: 9 min 45sec, number of excitations (NEX): 3, phase encoding as a diffusion-weighted imaging parameter. In order to scan, we set b-value to $0s/mm^2$, $400s/mm^2$, and $1,400s/mm^2$, and obtained T2 fat saturation image. Then we did a comparative analysis on the differences between image distortion and signal intensity depending on the location of X axial based on iso-center of patient's table. We used "Image J" as a comparative analysis programme, and used SPSS v18.0 as a statistic programme. There was not much difference between image distortion and signal intensity on fat and water from T2 fat saturation image. But, the average value depends on the location of X axial was statistically significant (p < 0.05). From DWI image, when b-value was 0 and 400, there was no significant difference up to $2^{nd}$ columns right to left from the core of patient's table, however, there was a decline in signal intensity and image distortion from the $3^{rd}$ columns and they started to decrease rapidly at the $4^{th}$ columns. When b-value was 1,400, there was not much difference between the $1^{st}$ row right to left from the core of patient's table, however, image distortion started to appear from the $2^{nd}$ columns with no change in signal intensity, the signal was getting decreased from the $3^{rd}$ columns, and both signal intensity and image distortion started to get decreased rapidly. At this moment, the reagent bottles from outside out of 11 reagent bottles were not verified from the image, and only 9 reagent bottles were verified. However, it was not possible to verify anything from the $5^{th}$ columns. But, the average value depends on the location of X axial was statistically significant. On T2 FS image, there was a significant decline in image distortion and signal intensity over 180mm from the core of patient's table. On diffusion-weighted image, there was a significant decline in image distortion and signal intensity over 90 mm, and they became unverifiable over 180 mm. Therefore, we should make an image that has a diagnostic value from examinations that are hard to locate patient's position.

ADVANTAGES OF USING ARTIFICIAL NEURAL NETWORKS CALIBRATION TECHNIQUES TO NEAR-INFRARED AGRICULTURAL DATA

  • Buchmann, Nils-Bo;Ian A.Cowe
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1032-1032
    • /
    • 2001
  • Artificial Neural Network (ANN) calibration techniques have been used commercially for agricultural applications since the mid-nineties. Global models, based on transmission data from 850 to 1050 nm, are used routinely to measure protein and moisture in wheat and barley and also moisture in triticale, rye, and oats. These models are currently used commercially in approx. 15 countries throughout the world. Results concerning earlier European ANN models are being published elsewhere. Some of the findings from that study will be discussed here. ANN models have also been developed for coarsely ground samples of compound feed and feed ingredients, again measured in transmission mode from 850 to 1050 nm. The performance of models for pig- and poultry feed will be discussed briefly. These models were developed from a very large data set (more than 20,000 records), and cover a very broad range of finished products. The prediction curves are linear over the entire range for protein, fat moisture, fibre, and starch (measured only on poultry feed), and accuracy is in line with the performance of smaller models based on Partial Least Squares (PLS). A simple bias adjustment is sufficient for calibration transfer across instruments. Recently, we have investigated the possible use of ANN for a different type of NIR spectrometer, based on reflectance data from 1100 to 2500 nm. In one study, based on data for protein, fat, and moisture measured on unground compound feed samples, dedicated ANN models for specific product classes (cattle feed, pig feed, broiler feed, and layers feed) gave moderately better Standard Errors of Prediction (SEP) compared to modified PLS (MPLS). However, if the four product classes were combined into one general calibration model, the performance of the ANN model deteriorated only slightly compared to the class-specific models, while the SEP values for the MPLS predictions doubled. Brix value in molasses is a measure of sugar content. Even with a huge dataset, PLS models were not sufficiently accurate for commercial use. In contrast an ANN model based on the same data improved the accuracy considerably and straightened out non-linearity in the prediction plot. The work of Mr. David Funk (GIPSA, U. S. Department of Agriculture) who has studied the influence of various types of spectral distortions on ANN- and PLS models, thereby providing comparative information on the robustness of these models towards instrument differences, will be discussed. This study was based on data from different classes of North American wheat measured in transmission from 850 to 1050 nm. The distortions studied included the effect of absorbance offset pathlength variation, presence of stray light bandwidth, and wavelength stretch and offset (either individually or combined). It was shown that a global ANN model was much less sensitive to most perturbations than class-specific GIPSA PLS calibrations. It is concluded that ANN models based on large data sets offer substantial advantages over PLS models with respect to accuracy, range of materials that can be handled by a single calibration, stability, transferability, and sensitivity to perturbations.

  • PDF

Comparative Study between ZOOMit and Conventional Intravoxel Incoherent Motion MRI for Assessing Parotid Gland Abnormalities in Patients with Early- or Mid-Stage Sjögren's Syndrome

  • Qing-Qing Zhou;Wei Zhang;Yu-Sheng Yu;Hong-Yan Li;Liang Wei;Xue-Song Li;Zhen-Zhen He;Hong Zhang
    • Korean Journal of Radiology
    • /
    • 제23권4호
    • /
    • pp.455-465
    • /
    • 2022
  • Objective: To compare the reproducibility and performance of quantitative metrics between ZOOMit and conventional intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) in the diagnosis of early- and mid-stage Sjögren's syndrome (SS). Materials and Methods: Twenty-two patients (mean age ± standard deviation, 52.0 ± 10.8 years; male:female, 2:20) with early- or mid-stage SS and 20 healthy controls (46.9 ± 14.6 years; male:female, 7:13) were prospectively enrolled in our study. ZOOMit IVIM and conventional IVIM MRI were performed simultaneously in all individuals using a 3T scanner. Quantitative IVIM parameters - including tissue diffusivity (D), pseudodiffusion coefficient (D*), and perfusion fraction (f) - inter- and intra-observer reproducibility in measuring these parameters, and their ability to distinguish patients with SS from healthy individuals were assessed and compared between ZOOMit IVIM and conventional IVIM methods, appropriately. MR gland nodular grade (MRG) was also examined. Results: Inter- and intra-observer reproducibility was better with ZOOMit imaging than with conventional IVIM imaging (ZOOMit vs. conventional, intraclass correlation coefficient of 0.897-0.941 vs. 0.667-0.782 for inter-observer reproducibility and 0.891-0.968 vs. 0.814-0.853 for intra-observer reproducibility). Significant differences in ZOOMit f, ZOOMit D*, D*, conventional D*, and MRG between patients with SS and healthy individuals (all p < 0.05) were observed. ZOOMit D* outperformed conventional D* in diagnosing early- and mid-stage SS (area under receiver operating curve, 0.867 and 0.658, respectively; p = 0.002). The combination of ZOOMit D*, MRG, and ZOOMit f as a new diagnostic index for SS, increased diagnostic area under the curve to 0.961, which was higher than that of any single parameter (all p < 0.01). Conclusion: Considering its better reproducibility and performance, ZOOMit IVIM may be preferred over conventional IVIM MRI, and may subsequently improve the ability to diagnose early- and mid-stage SS.

슬관절 연골 평가를 위한 자기공명영상 검사 시 지방 신호 억제 3D T2* Weighted 기법과 지방 신호 억제 3D SPGR 기법의 비교 및 유용성 평가 (The Comparative Analysis Study and Usability Assessment of Fat Suppressed 3D T2* weighted Technique and Fat Suppressed 3D SPGR Technique when Examining MRI for Knee Joint Cartilage Assesment)

  • 강성진
    • 한국자기학회지
    • /
    • 제26권6호
    • /
    • pp.219-225
    • /
    • 2016
  • 퇴행성 슬관절 연골 질환의 평가를 위하여 지방 신호 억제 3D SPGR 기법과 지방 신호 억제 3D $T2^*$ weighted 기법을 이용하여 자기공명영상을 획득하였다. 정량적 평가를 위해서 슬관절 연골을 내측대퇴연골(medial femoral cartilage, MFC), 내측경골연골(medial tibial cartilage, MTC), 외측대퇴연골(lateral femoral cartilage, LFC), 외측경골연골(lateral femoral cartilage, LFC), 슬개연골(patella cartilage, Pat) 구역으로 분류하여 관심영역을 설정한 후 각각의 신호강도, 신호 대 잡음비, 대조도 대 잡음비를 측정하였다. 측정된 값은 Mann-Whitney U-검정을 이용 두 기법간의 통계적 유의성을 검증하였다. 정성적 평가를 위해서 각각의 영상을 2명의 영상의학의가 관찰한 후 영상 내 인공음영, 연골의 경계, 조직 간 대조도, 병소의 묘사정도를 4점 척도(1점: 나쁨, 2점: 적당함, 3점: 좋음, 4점: 매우 좋음)로 평가하고, 그 결과를 바탕으로 Kappa-value 검정을 통해 통계적 유의성을 검증하였다. 영상획득에 사용된 장비는 3.0T MR system과 HD T/R 8ch knee array coil을 사용하였다. 정량적 분석결과, SNR 측정값을 토대로 한 두 기법 간의 통계적 유의성 검증 결과 MFC, LFC, LTC, Pat에서는 통계적으로 유의한 결과(p < 0.05)를 보였으나, MTC에서는 유의하지 않은 결과(p > 0.05)를 보였다. CNR 측정값의 통계적 유의성 검증 결과 MFC, LFC, Pat에서는 통계적으로 유의한 결과(p < 0.05)를 보였으나, MTC, LTC에서는 유의하지 않은 결과(p > 0.05)를 보였다. 정성적 분석결과, 영상의 평가항목별 결과 값의 평균을 비교해 보면 3D $T2^*$ weighted 영상에서 조금 높은 결과를 보였고, Kappa-value test를 이용한 두 관찰자간의 일치성 검증에서는 모든 평가항목에서 통계적으로 의미 있는 결과(p < 0.05)를 보였다. 결론적으로 3D $T2^*$ weighted 영상 기법은 3D SPGR 영상기법과의 비교에서 슬관절 연골의 묘사와 주변 조직 간의 대조도 및 병소의 묘사 등 영상의 평가에서 동등 및 그 이상의 진단적 가치를 낼 수 있다.

자기공명 담도췌장조영술에서의 SPIO 조영제의 유용성 평가 (Evaluation of Usefulness of SPIO (Superparamagnetic iron oxide) Contrast Agent in MRCP (Magnetic resonance cholangiopancreatography))

  • 홍인식;이해각;조재환;김현주;장현철;박철수;이선엽;구은회;동경래;조무성
    • 한국방사선학회논문지
    • /
    • 제5권3호
    • /
    • pp.143-148
    • /
    • 2011
  • 담낭 결석 환자 중 MRCP를 시행한 환자를 대상으로 SPIO 제제의 조영제를 경구 주입 전, 후를 정량적으로 비교 분석하여 그 유용성을 알아보고자 하였다. 2009년 01월부터 2010년 02월까지 담석증을 보이는 환자 36명을 대상으로 SPIO를 경구 투입한 그룹과 투입하지 않은 그룹으로 나누어 1.5T MR scanner를 사용하여 호흡 정지 기법과 호흡 유발 기법을 이용한 T2강조 영상을 획득 하였다. 측정 부위는 호흡 정지 기법을 이용한 T2강조 영상에서는 담낭의 중앙 부위와 주위 조직의 측정을 위해 담낭 중앙을 기준으로 전, 후로 각각 15mm 떨어진 부위에 위치시켰으며 호흡 유발 기법을 이용한 T2강조 영상에서는 담낭의 중앙 부위와 간의 5,6 구역에 위치시켰다. 실험에 대한 정량적 분석방법으로 두 그룹에서 관심영역의 신호대 잡음비를 구하고 평균화 하였으며 담낭의 신호대 잡음비를 기준으로 각각 관심영역의 대조도대 잡음비를 구하고 평균화 하여 두 그룹 간에 수치를 비교 분석하였다. 두 그룹에서의 대조도대 잡음비는 투입한 그룹에서 높은 대조도대 잡음비를 보였다.

유속신호증강효과의 자기공명혈관조영술을 이용한 뇌혈관검사에서 Half Scan Factor 적용한 영상 평가 (Evaluation of TOF MR Angiography and Imaging for the Half Scan Factor of Cerebral Artery)

  • 최영재;권대철
    • 한국자기학회지
    • /
    • 제26권3호
    • /
    • pp.92-98
    • /
    • 2016
  • 신호증강효과기법을 이용한 자기공명혈관술에서 뇌동맥을 half scan factor에 따른 절반스캔과 완전스캔의 영상을 평가하는데 목적으로 한다. 뇌혈관성 질환이 없는 환자(n = 30)를 대상으로 절반스캔과 완전스캔 하였고, 뇌동맥의 관심영역을 세 영역(C1, C2, C3)에서 7~8 mm의 범위로 설정하였다. MIP로 재구성한 영상으로 신호강도를 SNR(signal to noise ration), PSNR(peak signal noise to ratio), RMSE(root mean square error), MAE(mean absolute error)을 산출하고 paired t-test를 이용하여 통계분석 하였다. 스캔시간은 절반스캔(4분 53초), 완전스캔(6분 04초)이었다. 뇌혈관의 모든 ROI의 평균 측정 범위(7.21 mm)이었고, 첫번째 C1의 SNR은 완전스캔(58.66 dB), 절반스캔(62.10 dB)이었고, 양의 상관관계($r^2=0.503$)이고, 두 번째 C2의 SNR은 완전스캔(70.30 dB), 절반스캔(74.67 dB)이고 양의 상관관계($r^2=0.575$)이었다. 세 번째 C3의 완전스캔 SNR(70.33 dB), 절반스캔 SNR (74.64 dB)로 양의 상관관계를 ($r^2=0.523$)로 분석되었다. 절반스캔과 완전스캔의 비교에서 SNR($4.75{\pm}0.26dB$), PSNR($21.87{\pm}0.28dB$), RMSE($48.88{\pm}1.61$)이었고 MAE($25.56{\pm}2.2$)로 산출되었다. SNR은 두 검사 스캔에서 통계학적으로 유의하지 않았고 (p-value > .05) 영상의 질에서는 많은 차이가 없어 완전스캔을 사용하였을 때보다 적은 시간이 소요되는 절반스캔을 적용하여 검사하여도 된다.