• Title/Summary/Keyword: MR Valve

Search Result 135, Processing Time 0.029 seconds

Mitral Valve Reconstruction (승모판 재건술)

  • 이현우
    • Journal of Chest Surgery
    • /
    • v.28 no.12
    • /
    • pp.1107-1112
    • /
    • 1995
  • Between December 1993 and December 1994, fifty-eight percent of the mitral valve patients[33/57 had undergone mitral valve repair. Their mean age was 49[SD-16 years[range 11 - 75 and they were consisted with 15 males and 18 females. The causes of mitral disease in 33 patients were classified as follows: 19 cases[58% were degenerative, 9[27% were rheumatic, 3[9% were congenital and 2[6% were infectious. Carpentier`s functional classification was consisted with Class I 4 cases[12% , II 25 [76% and III 4 [12% . Surgical techniques included prosthetic annuloplasty in 32 cases[97% , leaflet resection in 16[48% , chorda shortening in 13[39% , chorda transfer in 9[27% , new chorda formation in 7[21% , commissurotomy in 7[21% , leaflet mobilization in 4[12% , chorda resection in 3[9% , papillary muscle splitting in 2[6% , cleft repair in 2[6% , leaflet patching in 1[3% and vegetation removal in 1[3% . Average number of mitral anatomical lesions per patient was 3.3 and We used average 3.0 procedures upon mitral valve apparatus per patient. Intraoperative transesophageal echocardiography was carried out in 27 patients[82% for providing an immediate and accurate assessment of the adequacy of the reconstruction before closure of the chest. Operative mortality was absent. The mean functional class[NYHA was 2.87 preoperative and improved to 1.03 postoperatively. Postoperative Doppler echocardiography showed much improvement from grade II MR[5 , grade III[5 , grade IV[21 to no MR[26 , only trace MR[3 , grade III MR[2 . Postoperative mean mitral valve area was 2.4$\pm$0.6cm2[range 1.5 - 4.0 . We conclude that cautiously evaluated mitral valve reconstruction is stable and predictable operation with minimal postoperative left ventricular dysfunction.

  • PDF

Constrained rotary MR damper design and its application (자기 유변 유체를 이용한 각도 제한 회전 감쇠기 설계 및 응용)

  • 김상화;박영진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.191-194
    • /
    • 1997
  • Passive, semi-active and active dampers have been used to dissipate energy in mechanical systems. Semi-active dampers have higher performance than passive dampers and require lower power to operate than active dampers. Its damping characteristics can be changed appropriately for varying conditions. In this paper, we developed a semi-active damper based on Magnetorheological(MR) fluid. MR fluid has a variable damping characteristics proportional for the magnetic field intensity. It has several advantages such as high strength, low viscosity, robustness in impurities and wide temperature range of operational stability. We designed a constrained rotary MR damper base on valve mode which can dissipate more energy per unit volume. The system with Bingham characteristics is obtained and proved by the experiment.

  • PDF

Severe Mitral Regurgitation Due to Coronary Vasospasm, Confirmed by Ergonovine Echocardiography (에르고노빈 심초음파로 확진된 승모판 폐쇄부전을 유발한 혈관연축 1예)

  • Cha, Jung-Joon;Kyung, Chan Hee;Cho, Jang Ho;Kim, Yong Hoon;Kim, Haewon;Lee, Sung-Joo;Rim, Se-Joong;Choi, Eui-Young
    • Journal of Yeungnam Medical Science
    • /
    • v.30 no.2
    • /
    • pp.120-123
    • /
    • 2013
  • The common causes of organic mitral regurgitation (MR) include mitral valve prolapse (MVP) syndrome, rheumatic heart disease, and endocarditis. MR also occurs secondary to dilated cardiomyopathy and coronary artery disease. In acute severe MR, the hemodynamic overload often cannot be tolerated, and mitral valve repair or replacement must be performed immediately. We report herein a case of severe MR due to coronary vasospasm that was confirmed via ergonovine echocardiography in a 70-year-old man. He was scheduled to undergo mitral valve surgery, but it did not push through and he was put on medical therapy.

Magnetoresistance Effect of [Pd/Co] Spin-valve with Perpendicular Anisotropy (수직자기이방성을 갖는 [Pd/Co] Spin Valve 구조에서 자기저항효과)

  • Choi, Jin-Hyup;Lee, Ky-Am
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.3
    • /
    • pp.173-177
    • /
    • 2006
  • We have investigated the magnetoresistance (MR) effect of the spin valve structures composed of perpendicularly magnetized Pd/Co multilayers, with changing the space layer (Pd or Cu) thickness, the stacking number of the Pd/Co multilayers, and the Co insertion-layer thickness. The Cu space layer showed larger MR ratio than the Pd space layer. The Co insertion-layer between Cu layer and pinned layer enhanced the MR ratio about three times. The maximum MR ratio of 7.4 % was established in the sample with the Co insertion-layer thickness of 0.62 and 1.01 nm.

Semi-Active Control for Improving Ride Comfort in Railway Vehicle by MR Damper (MR 댐퍼를 이용한 철도차량 승차감 반능동 제어)

  • Shin, Yu-Jeong;You, Won-Hee;Jung, Heung-Chae
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1929-1934
    • /
    • 2011
  • Recently the maximum speed becomes the most important performance in high speed train. But the speed up of train will not give the passenger good riding comfort. The semi-active suspension system by using variable damper with hydraulic solenoid valve is used to solve this problem. But the variable damper with hydraulic solenoid valve requires tank for supplying fluid. In this study, the MR(Magneto Rheological) damper was considered instead of hydraulic variable damper in order to improve riding comfort. Dynamic simulation was conducted for semi-active suspension system with MR damper was made by using Matlab-Simulink S/W. According to control strategy of MR damper for improving ride comfort in railway vehicle, The riding comfort of the railway vehicle with semi-active suspension system was analyzed and compared with conventional suspension system by using the program.

  • PDF

A Study on Development of a Noncontact Precision Flow-meter Using MR Sensor and PIC (MR 센서와 PIC를 이용한 비접촉식 정밀 유량계 개발에 관한 연구)

  • 이승희;이민철;고석조;장용석;최문호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1063-1066
    • /
    • 2003
  • A flow-meter and its measurement controller was developed for a hydraulic system. This study, for development of positive displacement flow-meter, consist of PIC(Peripheral Interface Controller) controller with MR(Magneto-resistive) sensors. This flow-meter is used valve position indicator for valve control system by hydraulic. The MR sensors are used for the rotation of OVAL gear that detecting device. In the ship environments, consideration that necessary explosive proof. Thus electro device or electro flow-meter needs explosion design for electric circuit. We designed noncontact type flow-meter and evaluated the safety and measuring abilities.

  • PDF

Magnetoresistance in Hybrid Type YBCO-NiO/NiFe/Cu/NiFe Film Structure

  • Lee, S.S;Rhee, J.R;Hwang, D.G;Rhie, K
    • Journal of Magnetics
    • /
    • v.6 no.3
    • /
    • pp.83-85
    • /
    • 2001
  • The magnetoresistance properties of NiO/NiFe/Cu/NiFe spin valve film deposited on MgO(100) substrate with YBa$_2$$Cu_3O_7$(YBCO) film were investigated at room temperature and at 77 K. The magnetoresistance (MR) curves of the hybrid superconductor-magnetoresistor film structure showed an exchange coupling field of 300 Oe and an inverse magnetoresistance ratio of -6.5%. The magnetization configurations of the two magnetic layers in the NiO spin valve were antiparallel due to an increment in the conduction electron flow to superconductor YBCO film. This sample showed an inverse MR ratio.

  • PDF

The design of low-power MR damper using permanent magnet (영구자석을 이용한 저전력형 MR 감쇠기의 설계)

  • Kim, Jung-Hoon;Oh, Jun-Ho
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.433-439
    • /
    • 2000
  • Lots of semi-active control devices have been developed in recent years because they have the best features of passive and active system. Especially, controllable magneto-rheological(MR) fluid devices have received significant attention in these area of research. The MR fluid is the material that reversibly changes from a free-flowing, linear viscous fluid to a semisolid with a controllable yield strength in milliseconds when exposed to a magnetic field. If the magnetic field is induced by moving a permanent magnet instead of applying current to a solenoid, it is possible to design a MR damper consuming low power because the power consumption is reduced at steady state. This paper proposes valve mode MR damper using permanent magnetic circuit that has wide range of operation with low power consumption and small size. To design a MR damper that has a large maximum dissipating torque and a low damping coefficient, a design parameter is adopted. The magnetic circuit, material of choke and choke type are selected experimentally with the design parameter. The behaviors of the damper are examined and torque tracking control using PID feedback controller is performed for step, ramp and sinusoidal trajectories.

  • PDF

A Sliding Mode Control for an Engine Mount Using Magneto-Rheological Fluid (MR유체를 이용한 엔진마운트의 슬라이딩모드제어)

  • 이동길;안영공;정석권;양보석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1144-1149
    • /
    • 2001
  • In this paper, a sliding mode controller of a fluid engine mount using MR (Magneto-Rheological) fluid was discussed When the MR fluid is applied to a fluid mount, resistance of MR fluid can be controlled by electro-magnetic valve installed in the inertia track. Since the rheological property of the MR fluid shows a function of shear rate, the damping characteristics of the mount will be change according to the frequency. Changing an applied magnetic field to the valve changes the property of the mount, such as the resistance of the MR fluid, the notch and the resonant frequencies due to the fluid passing, quantity of the fluid passing, the effective piston area of the volumetric damping and stiffness. Therefore, the fluid mount using MR fluid can be regarded as a variable structure system The sliding mode control known well as a particular type of variable structure control was introduced in this study. The sliding mode control, which has inherent robustness, is also expected to improve the control performance in the engine mount The sliding mode controller for the mount formatted by taking into account the response property with a time constant to MR fluid and the variable mount property. The motion equations of the fluid mount are derived from Newton's law of motion and used in numerical simulation. Numerical simulations illustrate the effectiveness of the sliding mode controller.

  • PDF

Magnetoresistance of Co/Cu/Co Spin Valve Sandwiches

  • Park, S. J.;Park, K. L.;Kim, M. Y.;j. R. Rhee;D. G. Hwang;Lee, S. S.;Lee, k. A.;Park, C. M.
    • Journal of Magnetics
    • /
    • v.2 no.1
    • /
    • pp.7-11
    • /
    • 1997
  • The dependence of magnetoresistance (MR) ratio on various variables like the thickness of the second Co layer, on the presence of cap layer, on deposition field (Hdep) and on annealing in Co/Cu/Co sandwiches was investigated. Spin-valve sandwiches were deposited on the corning glass by means of the 3-gun dcmagnetron sputtering at a 5 mTorr partial Ar pressure and room temperature. The deposition field was varied from 70 Oe to 720 Oe. The MR curve was measured by the four-terminal method with applied magnetic field up to 1000 Oe perpendicular to the direction of a current in the film plne. The MR ratio of glass/Fe(50${\AA}$)/Co(17${\AA}$)/Cu(24${\AA}$)/Cot(${\AA}$) fabricated by making 50 ${\AA}$ of Fe buffer layer has the maximum value of 8.2% when the thickness of the second Co layer was 17${\AA}$and the deposition field was 350 Oe. In the case of glass/Fe(50${\AA}$)/Co(17${\AA}$)/Cu(24${\AA}$)/Cot(${\AA}$) with Cu cap layer on top, the decrease in the MR ratio seemed to relate with the oxidation of the second Co layer. Samples prepared with deposition field showed greater MR ratios through the formation of more complete spin valve films. After annealing for 2 hours at 300$^{\circ}C$, the MR ratio of the samples prepared with deposition field decreased rapidly while the MR raito of the sample prepared without the field remained.

  • PDF