• 제목/요약/키워드: MR Images

검색결과 804건 처리시간 0.034초

The fate of necrosis-avid MR contrast material (Gadophrin-2)-enhanced area of acute reperfused myocardial infarction as determined by MR imaging with Gd-DTPA enhancement and TTC staining after four weeks in a rabbit model

  • Choe, Yeon-Hyeon;Park, Jong-Min;Weinmann, Hanns J.
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.114-114
    • /
    • 2002
  • Purpose: To know the fate of Gadophrin-2-enhanced areas in hearts with acute reperfused myocardial infarction. Method: The left anterior descending branches of coronary arteries were occluded for 90 min and reperfused for 60 min in 15 rabbits. Then, Gadophrin-2 (0.05 mmol/kg) was injected via ear veins. Short-axial T1-weighted spin echo images and fast cine images were obtained 24 hours after injection of Gadophrin-2. After four weeks, short-axial cine MRI was performed and T1-weighted spin echo Images were obtained 5 min and 15 min after injection of Gd-DTPA (0.2 mmol/kg). The animals were sacrificed and short-axial slices of the specimen were stained with 1.5% triphenyltetrazolium chloride (TTC) solution.

  • PDF

Supratentorial Gangliocytoma Mimicking Extra-axial Tumor: A Report of Two Cases

  • Ho Sung Kim;Ho Kyu Lee;Ae Kyung Jeong;Ji Hoon Shin;Choong Gon Choi;Shin Kwang Khang
    • Korean Journal of Radiology
    • /
    • 제2권2호
    • /
    • pp.108-112
    • /
    • 2001
  • We report two cases of supratentorial gangliocytomas mimicking an extra-axial tumor. MR imaging indicated that the tumors were extra-axial, and meningiomas were thus initially diagnosed. Relative to gray matter, the tumors were hypointense on T1-weighted images and hyperintense on T2-weighted images. On contrast-enhanced T1-weighted images, homogeneous enhancement was observed, while CT scanning revealed calcification in one of the two cases.

  • PDF

MR Imaging of Shaken Baby Syndrome Manifested as Chronic Subdural Hematoma

  • Yul Lee;Kwan Seop Lee;Dae Hyun Hwang;In Jae Lee;Hyun Beom Kim;Jae Young Lee
    • Korean Journal of Radiology
    • /
    • 제2권3호
    • /
    • pp.171-174
    • /
    • 2001
  • Shaken baby syndrome (SBS) is a form of child abuse that can cause significant head injuries, of which subdural hematoma (SDH) is the most common manifestation. We report the MRI findings of chronic SDH in three cases of SBS, involving two-, three- and eight-month-old babies. The SDH signal was mostly low on T1-weighted images and high on T2-weighted images, suggesting chronic SDH. In chronic SDH, a focal high signal on T1-weighted images was also noted, suggesting rebleeding. Contrast-enhanced MRI revealed diffuse dural enhancement.

  • PDF

최적의 FOV를 위한 MR신호강도와 신호 대 잡음비 값의 비교분석 (Analysis and Comparison of MR Signal Strength and SNR Value for Optimal FOV)

  • 이상호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.109-113
    • /
    • 2018
  • Despite the continuous development of software, it is continuously pursued to enlarge the examination area of FOV in order to reduce the factors of inconsistency in images that appear in continuous examination during wide area examination using contrast agent such as whole body angiography. In this study, we investigated the optimal FOV by comparing the SNR values according to the changes of FOV. The change of the FOV was gradually changed to $270{\times}200$, $300{\times}223$, $330{\times}244$, $360{\times}266$ and $380{\times}281$. SE images at TR 450 msec and TE 10 msec, FSE images at TR 2,000 msec, TE 80 msec, and GE images were scanned at TR 117 msec, and TE 16 msec. SNR values were calculated from the mean values of signal intensities of five phantom images and the signal intensity values of four background standard deviations. As a result of the study, the signal intensity and the SNR value according to the change of the FOV value gradually increased as the FOV was increased, but it was found that the SNR value decreased at a constant size. In conclusion, the results are different from previous studies that the SNR increases as the FOV increases. The cause of these results could not be confirmed. However methods that can be imaged and included within the effective FOV should be considered.

치료보조기구의 제작 및 유용성 평가 (The evaluation of usefulness of the newly manufactured immobilization device)

  • 서석진;김찬용;이제희;박흥득
    • 대한방사선치료학회지
    • /
    • 제17권1호
    • /
    • pp.45-55
    • /
    • 2005
  • 목적 : 최근의 방사선치료는 정상조직의 장애는 최대한 줄이고 종양조직 선량을 높여 치료효과를 극대화 하기위하여 3차원적으로 발전되어왔으며, 이에 따른 환자 체위고정을 위한 고정기구와 보조기구의 개발이 필수적으로 요구되고 있다. 본원에서는 MR head holder, 개방형 head holder, Plan CT couch plate를 자체 제작하여 그 유용성을 평가하고 분석하였으며, 임상에 적용한 결과를 보고하고자 한다. 대상 및 방법 : MR head holder를 제작하여 진단 MR영상과 치료계획용 MR영상을 CT영상과 fusion하여 두 영상의 일치성과 정확성을 분석하였고, 개방형 head holder를 제작하여 피부선량과 선량감약 정도를 알아보았으며, 6 mm 아크릴판에 스티로폼을 부착하는 CT couch plate를 제작하여 hard plate와 artifact 정도를 비교하였다. 결과 : Head holder를 사용하지 않은 fusion영상보다 2 mm이내의 오차로 정확한 fusion을 할 수 있었고, 개방형 head holder를 사용함에 따라 피부선량을 최대 2배 이상 줄일 수 있었고, $20\%$이상 선량이 감약되는 것을 최소화할 수 있었다. Plan CT couch plate를 사용했을 때는 2단 연결, 부착 식으로 제작하여 사용이 간편하고 artifact를 현저하게 줄일 수 있었다. 결론 : MR 영상에서도 기준 좌표점을 확인할 수 있어 정확한 MR / CT fusion을 시행할 수 있었고, 향후 PET, 초음파 영상의 fusion도 연구되어야 할 것으로 사료되며, 이에 따른 고정기구의 개발도 필수적이라 할 수 있겠다. 개방형 head holder를 사용함으로써 피부선량과 선량 감약을 감소시킬 수 있었다. 이러한 치료보조기구를 자체 제작하여 고가의 외국상품을 대체할 수 있어 비용은 절감할 수 있었지만 견고성에서는 떨어지므로 가볍고 선량 감약이 적으며 강도가 강한 특수 재질의 치료보조기구가 개발되어야 할 것으로 사료된다.

  • PDF

3D Rendering of Magnetic Resonance Images using Visualization Toolkit and Microsoft.NET Framework

  • Madusanka, Nuwan;Zaben, Naim Al;Shidaifat, Alaaddin Al;Choi, Heung-Kook
    • Journal of Multimedia Information System
    • /
    • 제2권2호
    • /
    • pp.207-214
    • /
    • 2015
  • In this paper, we proposed new software for 3D rendering of MR images in the medical domain using C# wrapper of Visualization Toolkit (VTK) and Microsoft .NET framework. Our objective in developing this software was to provide medical image segmentation, 3D rendering and visualization of hippocampus for diagnosis of Alzheimer disease patients using DICOM Images. Such three dimensional visualization can play an important role in the diagnosis of Alzheimer disease. Segmented images can be used to reconstruct the 3D volume of the hippocampus, and it can be used for the feature extraction, measure the surface area and volume of hippocampus to assist the diagnosis process. This software has been designed with interactive user interfaces and graphic kernels based on Microsoft.NET framework to get benefited from C# programming techniques, in particular to design pattern and rapid application development nature, a preliminary interactive window is functioning by invoking C#, and the kernel of VTK is simultaneously embedded in to the window, where the graphics resources are then allocated. Representation of visualization is through an interactive window so that the data could be rendered according to user's preference.

Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구 (Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm)

  • ;김태형;천송이;한용희;최기승;이광식;전재량;은충기;문치웅
    • Investigative Magnetic Resonance Imaging
    • /
    • 제12권2호
    • /
    • pp.131-141
    • /
    • 2008
  • 목적: 물체 내부의 온도를 비침습적으로 측정할 수 있는 양성자 공명 주파수 이동에 의한 MR 온도영상의 재구성에 center array-sequencing 위상펼침(PU) 기법을 적용시켜 그 성능 및 유용성을 평가하고자 하였다. 대상 및 방법: MR 온도 영상에 앞서 잡음 수준이 다른 타원형 팬텀들을 컴퓨터 모의 실험으로 제작하고 제안된 PU방 법을 적용시켜 잡음에 대한 성능을 평가하였다. MR 실험은 PU 실험과 이를 이용한 온도분포영상획득 실험으로 구분하여 수행되었다. 1.5T MR 영상장치에서 무릎코일과 $T2^*$ 경사자장에코 펄스열을 이용하여 MR 영상을 얻었다. 물통, 오렌지, 아가젤 등의 팬텀을 실험 대상으로 하였고 자체 제작된 온수펌프 장치로 팬텀의 온도를 조절하였다. T 형 열전쌍 온도측정장치로 팬텀 온도를 측정하고 MR 온도영상 결과와 비교하였다. 획득된 MR영상의 위상분포는 제안된 PU방법으로 위상을 편 후 온도분포 영상을 재구성하였다. 가열 전 후의 온도변화와 MR 영상의 위상변화 관계를 이용하여 아가젤 팬텀 내의 MR온도분포 영상을 구하였다. 결과: 제안된 center array-sequencing PU 알고리즘을 이용하여 여러 팬텀에 대한 MR 위상영상의 접힘 현상을 기존 방법보다 간편하고 빠르게 제거할 수 있었고 이를 이용하여 MR 온도영상을 획득할 수 있었다. 결론: 본 연구는 제안된 center array-sequencing 위상펼침 방법이 잡음에 강하고 처리 속도가 빠를 뿐만 아니라 양성자 공명 주파수 이동의 성질을 이용한 MR 온도 영상 획득에 성공적으로 적용될 수 있음을 보였다.

  • PDF

Morphologic Changes of L5 Root at Coronal Source Images of MR Myelography in Cases of Foraminal or Extraforaminal Compression

  • Kim, Soo-Beom;Jang, Jee-Soo;Lee, Sang-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권1호
    • /
    • pp.11-15
    • /
    • 2009
  • Objective: Two findings easily found at coronal source images of MR myelography (MRM) were evaluated : dorsal root ganglion (DRG) swelling and running course abnormality (RCA) of L5 exiting root at foramen or extraforamen. We tried to find the sensitivity of each finding when root was compressed. Methods: From 2004 July to 2006, one hundred and ten patients underwent one side paraspinal decompression for their L5 root foraminal or extraforaminal compression at L5-S1 level. All kinds of conservative treatments failed to improve leg symptom for several months. Before surgery, MRI, CT and MRM were done. Retrospective radiologic analysis for their preoperative MRM coronal source images was done to specify root compression sites and L5 root morphologic changes. Results: DRG swelling was found in 66 (60%) of 110 patients. DRG swelling has statistically valuable meaning in foraminal root compression (chi-square test, p<0.0001). Seventy-two (66%) in 110 patients showed abnormal alteration of running course. Abnormal running course has statistically valuable meaning in foraminal or extraforaminal root compression (chi-square test, p<0.0001). Conclusion: Three-dimensional MRM provides precise thin sliced coronal images which are most close to real operative views. DRG swelling and running course abnormality of L5 exiting root are two useful findings in diagnosing L5 root compression at L5-S1 foramen or extraforamen. MRM is thought to provide additional diagnostic accuracy expecially in L5-S1 foraminal and extraforaminal area.

측두하악관절의 초음파영상과 자기공명영상에서 하악과두 외측면과 관절낭간 거리 측정치 비교 (Comparison of the capsular width measured on ultrasonogrape and MR image of the temporomandibular joint)

  • 이태완;유동수;한원정;김은경
    • Imaging Science in Dentistry
    • /
    • 제36권1호
    • /
    • pp.41-48
    • /
    • 2006
  • Purpose : To evaluate the reliability and clinical usefulness of ultrasonography in the temporomandibular joint (TMJ). Materials and Methods : Parasagittal and paracoronal 1.5 T MR images and 7.5 MHz ultrasonographs of 40 TMJs in 20 asymptomatic volunteers were obtained. Disc position using MR imaging was evaluated and the distance between the lateral surface of mandibular condyle and the articular capsule using MR image and ultrasonograph of 27 TMJs with normal disc position was measured and compared. Intraobserver and interobserver measurements reliability was evaluated by using interclass correlation coefficients (ICC) and measurement error. Also, the distance measured on ultrasonographs was compared, according to mouth position and disc postion. Results : The normal disc position was found in 27 of 40 asymptomatic joints. At the intraobserver reliability of measurement, ICC at the closed and open mouth position were 0.89 and 0.91. The measurement error was 0.4% and 0.5%. At the interobserver reliability, ICC at the closed and open mouth position were 0.92 and 0.81. The measurement error was 0.4% and 0.7%. At the TMJ with normal disc position, the distances between the lateral surface of mandibular condyle and the articular capsule measured on MR images and ultrasonographs were $2.0{\pm}0.7mm,\;1.8{\pm}0.5mm$, respectively (p<0.05). On the ultrasonographs, the distances at open mouth position were $1.2{\pm}0.5mm$ (p<0.05). At the TMJ with medially displaced disc, the distances at the closed and open mouth position were $1.3{\pm}0.3\;mm\;and\;0.9{\pm}0.2\;mm$ (p<0.05). Conclusion : The results suggest ultrasonography of TMJ is a reliable imaging technique for assessment of normal disc position.

  • PDF