• Title/Summary/Keyword: MR Head

Search Result 177, Processing Time 0.027 seconds

Magnetic Circuit Design Methodology of MR CDC Dampers for Semi-Active Suspensions (반능동 서스펜션용 MR CDC 댐퍼의 자기회로 설계기법)

  • Park, Jae-Woo;Jung, Young-Dae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.10
    • /
    • pp.48-57
    • /
    • 2008
  • MR Fluid, one of functional fluids, is developed for the application to automobile products. MR CDC damper using MR fluid has following principles. When ar electric current is applied to the solenoid, apparent viscosity of MR fluid passing through the annular gap which acts as magnetic circuits varies directly as the intensity of the current. These devices have a simple structure and excellent lime response characteristics, emerging as the alternatives of the conventional semi-active suspension systems. In this study, a design procedure of the magnetic circuit through the solenoid fore and the flux ring functioning as a magnetic path is investigated so as to optimize the design and performance of MR CDC dampers for the vehicles. In addition, an operating point on the B-H curve, the magnetization according to the variation in the annular gap, the pole piece width and the density of MR fluid are studied to design the optimal piston head within the restrained dimension range.

Mixed Reality(MR) Technology Trends and Development Prospect (혼합현실(Mixed Reality) 기술 동향과 발전 전망)

  • Moon, Hyung-Nam;Cho, Hee-in;Han, Youngmi
    • The Journal of the Convergence on Culture Technology
    • /
    • v.3 no.3
    • /
    • pp.21-25
    • /
    • 2017
  • In this paper, we review relevant technologies of Mixed Reality(MR) and show important components of perspective that can overcome technical limitations of the current MR. An MR technology combines real and virtual objects in a real environment, and runs interactive in real time, and is regarded as an emerging technology in a large part of the future of Information Technology(IT). We've grouped the major obstacles limiting the wider use of MR technologies into three themes: technological limitations (i,e., tracking, rendering, authoring, and registration), user interface(UI) limitations(i.e., UI metaphor for MR interaction), and social acceptance issues.

Design and Optimization of 4-Channel SENSE Head Coil

  • 오정민;김용권;류연철;오창현
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.16-16
    • /
    • 2003
  • Purpose: Recently, a major interesting method of fast MR imaging is sensitivity encoding (SENSE) using arrays of multiple receiver coils. In this study, we have designed and implemented a 4-channel head array coil and optimized the structure and arrangement of the coil to improve the performance.

  • PDF

Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch (대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : To assess the clinical utility of turbo contrast-enhanced magnetic resonance angiography(CE MRA) in the evaluation of the aortic arch and its major branches and to compare the image quality of CE MRA among different coils used. Materials and Methods : Turbo three-phase dynamic CE MRA encompassing aortic arch and its major branches was prospectively performed after manual bolus IV injection of contrast material in 29 patients with suspected cerebrovascular diseases at 1.0T MR unit. the raw data were obtained with 3-D FISH sequence (TR 5.4ms, TE 2.3ms, flip angle 30, slab thickness 80nm, effective slice thickness 4.0mm, matrix size $100{\times}256$, FOV 280mm). Total data acquisition time was 4. to 60 seconds. We subjectively evaluated the imge quality with three-rating scheme : "good" for unequivocal normal finding, "fair" for relatively satisfactory quality to diagnose 'normal' despite intravascular low signal, and "poor" for equivocal diagnosis or non-visualization of the origin or segment of the vessels due to low signal or artifacts which needs catheter angiography. At the level of the carotid bifurcation, it was compared with conventional 2D-TOF MRA image. Overall image quality was also compared visually and quantitatively by measuring signal-to-noise ratios (SNRs) of the ascending aorta, the innominate artery and both common carotid arteries among the three different coils used(CP body array(n=12), CP neck array(n=9), and head-and-neck(n=8). Results : Demonstration of the aortic arch and its major branches was rated as "good" in 55% (16/29) and "fair" in 34%(10/29). At the level of the carotid bifurcation, image quality of turbo CE MRA was same as or better than conventional 2D-TOF MRA in 65% (17/26). Overall image quality and SNR were significantlygreater with CP body array coil than with CP neck array or head-and-neck coil. Conclusions : Turbo CE MRA can be used as a screening exam in the evaluation of the major branches of the aortic arch from their origin to the skull base. Overall imagequality appears to be better with CP body array coil than with CP neck array coil or head-and-neck coil.

  • PDF

Traumatic Brainstem Hemorrhage Presenting with Hemiparesis

  • Se, Young-Bem;Kim, Choong-Hyun;Bak, Koang-Hum;Kim, Jae-Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.3
    • /
    • pp.176-178
    • /
    • 2009
  • Traumatic brainstem hemorrhage after blunt head injury is an uncommon event. The most frequent site of hemorrhage is the midline rostral brainstem. The prognosis of these patients is poor because of its critical location. We experienced a case of traumatic brainstem hemorrhage. A 41-year-old male was presented with drowsy mentality and right hemiparesis after blunt head injury. Plain skull radiographs and brain computerized tomography scans revealed a depressed skull fracture, epidural hematoma, and hemorrhagic contusion in the right parieto-occipital region. But, these findings did not explain the right hemiparesis. T2-weighted magnetic resonance (MR) image of the cervical spine demonstrated a focal hyperintense lesion in the left pontomedullary junction. Brain diffusion-weighted and FLAIR MR images showed a focal hyperintensity in the ventral pontomedullary lesion and it was more prominent in the left side. His mentality and weakness were progressively improved with conservative treatment. We should keep in mind the possibility of brainstem hemorrhage if supratentorial lesions or spinal cord lesions that caused neurological deficits in the head injured patients are unexplainable.

Evaluation of the Resolution Characteristics by Using American College of Radiology Phantom for Magnetic Resonance Imaging (자기공명영상에서 ACR 팬텀을 이용한 해상력 특성 평가)

  • Min, Jung-Whan;Jeong, Hoi-Woun;Han, Ji-Hyun;Lee, Si-Nae;Kim, Min-Ji;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.11-17
    • /
    • 2022
  • This study was purpose to quantitative assessment of the resolution characteristics by using American college of radiology(ACR) phantom for magnetic resonance imaging (MRI). The MRI equipment was used (Achiva 3.0T MRI, Philips system, Netherlands) and the head/neck matrix shim SENSE head coil were 32 channels(elements) receive MR coil. And the MRI equipment was used (Discovery MR 750, 3.0T MRI, GE medical system, America) and the head/neck matrix shim MC 3003G-32R 32-CH head coil were receive MR coil. As for the modulation transfer function(MTF) comparison result by using ACR magnetic resonance imaging phantom, the MTF value of the ACR standard T2 image in GE equipment is 0.199 when the frequency is 1.0 mm-1 and the MTF value of the hospital T2 image in Philips equipment is 0.528. It was used efficiently by using a general sequence more than the standard sequence method using the ACR phantom. In addition it is significant that the quantitative quality assurance evaluation method for resolution characteristics was applied mutatis mutandis, and the result values of the physical image characteristics of the 3.0T MRI device were presented.

A COMPARATIVE STUDY ONMAGNETIC RESONANCE IMAGE AND SECTOGRAPH OF HUMAN TNJ (악관절의 자기공명영상과 시상단층 방사선촬영상에 관한 비교연구)

  • Lee, Sung-Bok;Choi, Dae-Gyun;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.249-270
    • /
    • 1993
  • For understanding of anatomy, physiology, and diseases of human TMJ, it is required to evaluate quantitatively the movement of the disc and condyle head of mandible. The histologic section of cadaver TMJ were examined, and the magnification of the MR image and its details of anatomy were evaluated. And then a quantitative analytic method, by comparing the Sectograph and the MR image of vital human TMJ, was proposed. For this study, 15 subjects(Male, 24~35years) were selected from a prosthodontic examination randomly, and each subject’s five interocclusal rubber registration records were made on the ICP, and 5, 10, 15, and 20mmjaw opening positions. All subjects were radiographed with a Denar Quint Sectograph Image System(Denar Corp., USA), and imaged with a MRP-20EX MR Image System(0.2T, Permanent Magnet Type, Hitachi Medical Corp., Japan) using an 100mm diameter bilateral type surface coil. These images were traced on the acetate tracing paper, and analyzed In this study, the findings led to the following conclusions. 1. In comparison of the histologic section of autopsy specimen with the MR image at the same section, the size(dimension) of MR image was 70% of the real one. It was possible to recognize the shape of articular disc, anterior and posterior attachments, and adjacent soft tissues, because of the excellent reproducibility of anatomical structure. 2. When we compared the amount of joint space on MR image with that of joint space on sectograph, the amount of joint space on sectograph was significantly greater than that of joint space on MR image, except at the top of condylar head. 3. The position of minimum joint space on sectograph at intercuspal position didn't coincide with the middle position of articular disc on MR image, and was approximately in the anterior third of posterior band of articular disc. 4. The amount of condylar movement on MR image at opening movement was greater than that of articular disc movement. From Intercuspal position to 5mm jaw-opening movement, the condylar movement showed hinge one, and over the range 5mm jaw-opening it suggested hinge & translatory one. 5. In terms of area variation of articular disc measured on MR image in sagittal plane, the area of posterior band increased with increasing the amount of Jaw opening, but the area of anterior band decreased conversely.

  • PDF

Morphological Characteristics of Three Species, Genus Chaenogobius(Gobiidae), from Korea (한국산 꾹저구속(망둑어과) 3종에 대한 형태적 특징)

  • 김영자;전상린
    • Korean Journal of Environmental Biology
    • /
    • v.18 no.4
    • /
    • pp.387-394
    • /
    • 2000
  • The morphological characteristics between male and female of three species, Chaenogobius urotaenia, C. sp. MR, C. sp. BW, collected from June 1996 to Aug. 1999, Korea was studied. Of 13 characters to be studied, 12 characters with exception of caudal fin ray length were significantly different among three species and these three species were distinguished each other by the results of the multiple comparison test (REGWQ test). Interspecific differences in female was distinct in body depth, head length, caudal peduncle length, caudal peduncle depth, snout length, pectoral fin ray length; In particular, C. sp. MR was shorter in upper jaw length, anal fin ray length and eye diameter, and to be smaller in head depth and head width than other two species. Chaenogobius urotaenia was longer in pelvic fin ray length. In case of male, there was not characters to distinguish each one among three species; Chaenogobius urotaenia was longer in head length, eye diameter and pelvic fin ray length than other two species, C. sp. MR to be longer in caudal peduncle length, but shorter in snout length and anal fin ray length, and to be lower in head depth. C. sp. BW was higher in body depth and caudal peduncle depth, and to be longer in upper jaw length and pectoral fin ray length. Both of male and female among three species didn't have any difference in caudal fin ray length. [Chaeogobius urotaenia, C. sp. MR, C. sp. BW, morphological characteristics].

  • PDF

Magnetization Distribution in Thin-Film Magnetic Head

  • Shin, Kyung-Ho;Shalyguina, E.E.;Lee, J.H;Rhie, K.
    • Journal of Magnetics
    • /
    • v.5 no.2
    • /
    • pp.55-58
    • /
    • 2000
  • Local magnetic properties and magnetization distributions on the air-bearing surface of a thin-film magnetic head have been studied by using scanning magneto-optical Kerr microscopy. The examined head was a merged MR read/inductive writing head with a write gap equal to 0.3 $\mu m$. Sizes of top and bottom pole-tips on the air-bearing surface of the writing head were equal to $3\mu m\times3\mu m$ and $3\mu m\times30\mu m$, respectively, The measured magnetic characteristics on the head air-bearing surface were found to be very sensitive to the head design. In particular, magnetization distributions were discovered to have asymmetrical shape. Maximum magnitudes of the magnetization were located near the shorten pole-tip. So, it was experimentally proved that more magnetic flux emanates just from this part of the air-bearing head surface.

  • PDF

The Study of Corrosion Induced Co migration and Its Effect on Thermal Asperity Phenomenon (부식작용으로 인하여 디스크면으로 이동된 코발트가 Thermal Asperity 현상에 미치는 영향)

  • 좌성훈
    • Tribology and Lubricants
    • /
    • v.15 no.4
    • /
    • pp.335-342
    • /
    • 1999
  • Corrosion of the disk has been an ongoing concern for the manufacturers of hard disk drives. With the advent of magnetoresistive (MR) head, very low levels of corrosion and contamination become more critical since the raised defects and corrosion products on the disk surface-anything that heats the MR sensor due to the contact-can distort the output signal of the head. This phenomenon is called as thermal asperity. In this paper, the effect of corrosion as a form of Co migration on the occurrence of thermal asperity in MR drives was investigated. The corrosion test at high temperature (60$^{\circ}C$) and high relative humidity (80%) was emphasized in this study and the testing results at ambient condition were compared. The corrosion on the disks was characterized as the amount of Co ion migration using an ion chromatography (IC) and a time-of-flight secondary ion mass spectroscopy (TOF-SIMS). It is proved that corrosion on the disk surface after storage testing is closely correlated to the amount of Co ions migration from the magnetic layer to disk surfaces and higher Co migration causes more thermal asperities in the drive. In order to reduce Co migration, several methods such as burnishing process and structure of the carbon overcoat were investigated. It is found that the hydrogenated carbon overcoat shows the least Co migration among different types of overcoat layer. However, the most effective way to reduce Co migration is the application of Cr layer between the overcoat and the magnetic alloy layer.