• 제목/요약/키워드: MR Head

검색결과 178건 처리시간 0.019초

HDD에서 Smooth 디스크와 Texture 디스크가 IDI의 마찰대전에 미치는 영향 (Effects of Smooth and Textured Disks on Tribocharge build-up at a Head Disk Interface of HDD)

  • 이대영;이래준;강필선;한제희;황정호;김대은;조긍연;강태식
    • 정보저장시스템학회:학술대회논문집
    • /
    • 정보저장시스템학회 2005년도 추계학술대회 논문집
    • /
    • pp.96-102
    • /
    • 2005
  • The tribocharge build-up in the slider disk interface can cause ESD (electrostatic discharge) damage. In turn, ESD can cause severe melting damage to MR or GMR heads. We investigated the tribovoltage/current build-up with smooth and textured disks in HDD, operating at increasing disk accelerations. We found that tribe-voltage/current were generated during pico-slider/disk interaction and those levels were about 0.1 ${\~}$ 0.3 V and 10 ${\~}$ 40 pA, respectively. Tribovoltage/current were abruptly increased and dissipated within the acceleration time in the case of textured disk but in the case of smooth disk tribovoltage was continuously increased until the end of uniform velocity region and the tribocurrent did not dissipate within the acceleration time. In the case of textured dist tribovoltage/current was reduced with increasing disk acceleration, but in the case of smooth disk it was increased.

  • PDF

대퇴이두건과 외측 측부인대: 자기공명영상을 이용한 부착형태 유형의 분석 (Biceps Femoris Tendon and Lateral Collateral Ligament: Analysis of Insertion Pattern Using MRI)

  • 신윤경;류경남;박지선;이정은;진욱;박소영;윤소희;이경렬
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권3호
    • /
    • pp.225-231
    • /
    • 2014
  • 목적: 슬관절에서 대퇴이두건과 외측 측부인대는 병합건을 형성하여 비골에 붙는다고 알려져있다. 그러나 대퇴이두건과 외측 측부인대는 여러 형태로 비골두에 붙는다. 우리는 자기공명영상을 이용하여 대퇴이두건과 외측 측부인대의 부착 형태를 분류하였고 외측 측부인대가 비골두에 붙는지 여부를 분석하였다. 대상과 방법: 2012년 7월부터 2012년 12월 사이에 슬관절 자기공명영상을 촬영한 470명의 환자의 총 494개의 자기공명영상을 후향적으로 평가하였다. 224명의 남자, 246명의 여자가 포함되었으며 나이는 10세에서 88세(평균, 48.6세) 범위였다. 배제기준은 이전의 수술을 받거나 영상질이 나쁜 경우였다. 3T 지방억제 수소밀도 강조영상을 이용하여 대퇴이두건과 외측 측부인대의 비골부착 형태를 다음과 같이 분류하였다: 유형 I (외측 측부인대가 대퇴이두건 장골의 전방팔과 직접팔 사이로 지나간다), 유형 II (외측 측부인대가 대퇴이두건 장골의 전방팔과 합쳐진다), 유형 III (대퇴이두건과 외측 측부인대가 병합건을 형성한다), 유형 IV (외측 측부인대가 대퇴이두건의 전방으로 돌아 외측으로 지나간다), 유형 V (외측측부인대가 대퇴이두건 장골의 직접팔의 후방으로 지나간다). 결과: 슬관절 자기공명영상의 494 증례 가운데, 유형 I이 433 (87.65%)예, 유형 II가 21 (4.25%)예, 유형 III이 2 (0.4%)예, 유형 IV가 16 (3.23%)예, 유형 V가 22 (4.45%)예 였다. 대퇴이두건과 외측 측부인대가 비골두에 붙지않는 경우는 26 (5.26%)예 였다. 결론: 대퇴이두건과 외측 측부인대의 비골두 부착은 자기공명영상에서 다양한 형태를보인다. 외측 측부인대는 어떤 환자에서는 비골두에 부착하지 않는다.

급성 허혈성 뇌경색 환자에서 동맥스핀표지 관류자기공명영상의 유용성 (Clinical Usefulness of Arterial Spin Labeling Perfusion MR Imaging in Acute Ischemic Stroke)

  • 오근택;정홍량;임청환;조영기;하본철;홍동희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권4호
    • /
    • pp.323-331
    • /
    • 2011
  • 본 연구는 급성 허혈성 뇌경색 환자에서 동맥스핀표지 관류자기공명영상의 임상적 유용성을 평가하고자 하였다. 급성 허혈성 뇌경색 증상으로 응급실로 내원한 환자 중 확산강조영상(DWI)의 병변의 크기가 3 cm 이상이고 역동적 자화율대조 조영증강 관류자기공명(DSC)영상, 동맥스핀표지 관류자기공명(ASL)영상을 모두 시행한 22명과 정량적 분석을 위한 정상대조군 36명을 대상으로 하였다. 사용된 장비로는 Siemens Magnetom Verio 3.0 T이고 12 Chanel Head Coil을 사용하였다. 정성적 평가는 rMTT, TTP, rCBF, rCBV, ASL지도의 병변 인지도평가와 확산강조영상과 병변의 크기 비교평가를 하였고 정량적 평가는 각 관류영상의 평균 상대값을 Mann-Whitney U test를 사용하여 병변 그룹과 정상군 그룹의 유의성을 분석한 결과는 다음과 같다. 첫째, 병변의 인지도평가에서 TTP(95.5%), rCBF(95.5%), 지도가 가장 높았고, 둘째, 최종 뇌경색부위 연관성은 rCBV와 rCBF지도가 높게 나타났다. 셋째, 정량적 분석에서는 병변그룹의 평균 상대값은 유의하게 나타났다(p<0.05). 동맥스핀표지 관류자기공명(ASL)영상은 높은 병변의 인지율을 보여 임상에서 적용가능하다 생각되며, 정량적 상대값은 제시하기 어렵지만 참고적 자료로 사용될 수 있을 것이며 향후 지속적 연구를 한다면 뇌경색의 조기진단, 허혈성 반영부의 존재여부와 범위, 혈류역동학적평가가 가능함으로써 치료방침을 정하고 예후를 파악하는데 ASL영상이 유용할 것으로 사료된다.

연령에 따른 고관절주위 대퇴골 및 절구뼈 골수전환 양상 : MR 평가 (Marrow Conversion Pattern of the Femora and Acetabulum Around Hip Joints According to Age Group : MR Evaluation)

  • 이인숙;최현욱;서임정;우성구;문태용
    • Investigative Magnetic Resonance Imaging
    • /
    • 제10권2호
    • /
    • pp.63-69
    • /
    • 2006
  • 목적 : 고관절주위 대퇴골 및 절구뼈에 질병이 이환되었을 때는 골수 변성이나 부종이 발생하지만 연령에 따른 정상 골수전환이나 재전환을 감별하지 못하면 진단이 어려워진다. 이에 정상 골수 전환 양상을 연령군으로 분류하여 분석해 보았다. 대상 및 방법 : 자기공명영상에서 고관절 및 고관절주위 대퇴골와 절구뼈에 이상소견이 없고 혈청검사에서 골수이상을 초래할 만한 자가면역질환이나 혈액질환이 없는 144명 288개 고관절을 대상으로 하였다. T1강조영상으로 고관절주위 대퇴골 및 절구뼈의 골수를 관찰하였으며 골수 신호강도가 근육 신호강도에 가까우면 적색골수, 지방 신호강도에 가까우면 황색골수로 간주하였다. 대퇴골 골수는 머리, 목, 그리고 큰돌기, 작은돌기 그리고 돌기사이를 포함한 돌기 부위로 나누었고 절구뼈 골수는 황색골수 전환 절반이상과 이하로 나누었다. 연령은 10년 단위로 나누었고 또한 태생부터 10살까지는 1년 단위로 나누었다. 결과 : 절구뼈 절반이하 골수전환 되고, 대퇴골 머리 목 그리고 돌기가 골수전환 된 경우가 226례 78.5%, 대퇴골 머리와 돌기만 골수전환 된 경우는 44예 15.3% 였다. 연령별 골수전환 범위는 만2세전후부터 커지기 시작하여 만20세전후에서 끝나는 양상을 보였다. 결론 : 고관절주위 대퇴골 및 절구뼈의 연령별 정상 골수전환 양상을 이해함으로써 질병으로 인한 골수 변성이나 부종을 감별하고 드물지 않게 고관절 통증을 호소하는 전이암이나 백혈병 같은 골수대체성 질환을 진단 할 수 있을 것으로 사료된다.

  • PDF

외상후 뇌손상 환자에서 Tc-99m-HMPAO 국소뇌혈류 SPECT와 자기공명영상의 비교 (Comparison of Tc-99m-HMPAO SPECT and MRI after Acute and Subacute Closed-Head Injury)

  • 유원종;이상훈;손형선;이한진;박정미;정수교;김춘열;박용휘;신경섭
    • 대한핵의학회지
    • /
    • 제28권3호
    • /
    • pp.301-306
    • /
    • 1994
  • The purpose of this study was to compare Tc-99m-HMPAO SPECT with MRI after acute and subacute closed-head injury. There were thirty two focal lesions in all cases of these. Fifteen lesions(47%) were seen on both MRI and SPECT. Fourteen lesions(44%) were seen only on MRI. Three lesions(9%) were seen only on SPECT. Of the 14 lesions seen only on MRI, one was epidural hematoma, two were subdural hematoma, three were subdural hygroma, one was intracerebral hematoma, four were contusion, and three were diffuse axonal injuries. SPECT detected 52% of the focal lesions found on MRI. For the detection of lesions, MRI was superior to SPECT in fourteen cases, while SPECT was superior to MRI in three cases. In conclusion, there was a tendency that detection rate of the traumatic lesions was higher on MRI, but the SPECT could delineate more wide extent of lesion.

  • PDF

새로운 건강보험 보장성 강화 대책 1부: 뇌 MRI, 뇌혈관/경부혈관 MRA, 두경부 MRI 급여 확대 (A New Healthcare Policy in Korea Part 1: Expanded Reimbursement Coverage of Brain MRI, Brain/Neck MRA, and Head and Neck MRI by National Health Insurance)

  • 김은희
    • 대한영상의학회지
    • /
    • 제81권5호
    • /
    • pp.1053-1068
    • /
    • 2020
  • 문재인 정부의 새로운 건강보험 보장성 강화 대책에 따라 2018년부터 뇌 MRI, 뇌혈관/경부혈관 MRA, 두경부 MRI 급여가 확대되어 시행 중이다. 2018년 10월부터 2020년 4월까지 개정되어 현재 시행 중인 MRI 급여와 관련된 '요양급여의 적용기준 및 방법에 관한 세부사항'을 중심으로 정리해 보았다. 이 종설은 MRI 요양급여체계, 두통, 어지럼증 환자의 급여기준조정, 뇌 MRI, 뇌혈관/경부혈관 MRA, 두경부 MRI의 급여기준, 표준영상, 판독소견서 등을 포함하였다. 이 글을 통해 영상의학과 전문의가 보험 영역에서도 전문적인 지식을 갖추어 영상의학과 전문의의 전문성을 확보하고, 소속병원에서 주도적인 역할을 하는데 도움이 되고자 한다. MRI 급여화 확대 정책이 진행 중으로 관련 보건복지부의 세부고시가 개정될 수 있다. 따라서 MRI와 보험과 관련된 사안을 지속적으로 업데이트하는 것이 요망된다.

경도 두부외상 환자에서 뇌좌상주위 부종영역에서의 자기공명분광법을 이용한 대사변화 (Metabolic Changes in Pericontusional Edematous Areas in Mild Head Injury Evaluated by Proton MRS)

  • 홍상수;손병철;최병길;김의녕;김범수;박춘근;최보영;김문찬;강준기
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권9호
    • /
    • pp.1233-1237
    • /
    • 2000
  • Objectives : In order to evaluate the metabolic changes associated with pericontusional edematous area in mild head injury, proton magnetic resonance spectroscopy(1H-MRS) was performed in mild head injury patients (initial GCS score 13-15) with focal brain contusion. Methods : Seven head injury patients with initial GCS 13-15(3 males and 4 females : age range 15-65 years, mean age 33 years) have underwent 1H-MRS evaluations. The patients were examined within 7 days after injury(n=7) and 2 months after injury(n=5). The region of interest(ROI) was selected in the edematous area adjacent to traumatic brain contusion upon T2-weighted MR images and a corresponding region of the contralateral hemisphere (ROC, region of contralateral corresponding hemisphere) was examined as well. The metabolic ratios of NAA/Cr and lactate/Cr were compared between ROIs, ROCs and control values. Results : In initial NAA/Cr ratios, the values of ROIs were significantly lower than those of the controls(p=0.009), but there was no difference either between ROIs and ROCs(p=0.410) or between ROCs of patients and the control (p=0.199). In lactate/Cr ratios, the ROIs in all seven patients and the ROCs in two showed increased lactate signals. The lactate/Cr ratios of the ROIs were significantly elevated as compared to those of the ROCs(p=0.02) and the control(p=0.015). In two months follow-up, lactate signals were absent or significantly reduced(p=0.015). In no patients, clinical or radiological deterioration has been observed. Conclusion : Our 1H-MRS results demonstrate that there are significant ischemic changes in pericontusional edematous areas as indicated by elevated lactate signals in the patients with mild head injury. But there were no consistent neural loss or dysfunction in these area. There findings suggest that pericontusional edematous areas can be vulnerable to secondary brain insults even in the patients with mild head injury.

  • PDF

두경부 방사선 치료 환자에서 투과선량 알고리즘의 임상 적용시 불균질 조직 보정에 관한 연구 (Tissue Inhomogeneity Correction in Clinical Application of Transmission Dosimetry to Head and Neck Cancer Radiation Treatment)

  • 김수지;하성환;우홍균;허순녕
    • Radiation Oncology Journal
    • /
    • 제22권2호
    • /
    • pp.155-163
    • /
    • 2004
  • 목적 : 두경부에 방사선 치료를 받는 환자에서 투과선량측정시스템을 적용하여 시스템의 재현성과 선량 계산 알고리즘의 정확도를 확인하기 위하여 본 연구를 시행하였다. 대상 및방법 : 2001년 9월 5일부터 9월 18일까지 괴 MV선형가속기를 이용하여 두경부에 방사선치료를 시행한 환자를 대상으로 하였으며, 3회 이상의 측정을 시행하고 조사야의 중심이 차폐되지 않은 35명의 환자를 대상으로 분석을 시행하였다. 매일 환자의 치료 시작 전과 치료 중 한 시간 간격으로 10$\times$10 cm$^{2}$개방 조사야에 100 MU을 조사하고 측정을 시행하여 시스템의 안정성 및 재현성을 확인하였다. 투과선량 계산 알고리즘의 정확도를 평가하기 위하여 두경부 방사선치료 환자에서 투과선량의 예상치를 구하고 측정치와 비교하였다. 투과선량 예상치는 환자의 CT 또는 MR 영상과 모의치료 시의 X-선 필름을 사용하여 방사선 투과 부위의 골조직, 공기, 지방조직의 두께를 측정하고 이에 대한 불균질 조직의 영향을 보정하였다. 결과 : 10$\times$10 cm$^{2}$개방 조사야에 100 MU을 조사하여 측정을 시행하였을 때 측정치의 일 중의 오차가 $\pm$0.5$\%$ 이내이고 일간의 오차가 $\pm$1.0$\%$ 이내로 시스템의 안정성 및 재현성을 확인할 수 있었다. 투과선량 예상치와 실제 측정치 간의 평균 오차는 뇌 부위 치료 환자에서는 $\pm$5$\%$ 이하, 두부 치료 환자에서는 $\pm$2.5$\%$ 이하, 경부 치료 환자에서는 $\pm$5$\%$ 이하이었다. 결론 : 투과선량측정시스템의 안정성과 재현성을 확인할 수 있었고, 외부 형태가 불규칙하고 불균질 조직이 포함되는 부위에 대하여 CT, MR 등의 영상을 이용하여 불균질 조직에 대한 보정을 함으로써 정확한 예상치를 구할 수 있음을 확인하였다.

East Meets West: A Critical Analysis on The Evolution, Growth and Transfer of QFD from Japan to The West

  • Zairi, Mohamed;Ginn, Mr.David
    • International Journal of Quality Innovation
    • /
    • 제4권1호
    • /
    • pp.1-19
    • /
    • 2003
  • This paper describes the origins, evolution of Quality Function Deployment and its transfer to the West. Following a comprehensive review of the literature and how QFD has been defined, and applied, the paper analyses the critical factors which impinge on QFD implementation success. A discussion which covers the enabling criteria found to be inherent in Japanese applications is contrasted with the Western approaches documented hitherto. In particular the Company Wide Quality Control (CWQC) approach in Japan versus the emerging concept of Total Quality Management and their impact on QFD implementation. A critical analysis of the main differences isolated from the review of the literature and which characterise the Japanese method of QFD implementation which is leading, and The Western approaches which appear to be lagging is included in the paper, together with some useful conclusions:

HDD 내 디스크 표면 특성이 미세입자의 부착 및 이탈에 미치는 영향 (Effect of Characteristics of Disk Surface on Particle Adhesion and Removal in a Hard Disk Drive)

  • 박희성;좌성훈;황정호
    • Tribology and Lubricants
    • /
    • 제16권6호
    • /
    • pp.415-424
    • /
    • 2000
  • The use of magnetoresistive (MR) head requires much tighter control of particle contamination in a drive since loose particles on the disk surface will generate thermal asperities (TA). In this study, a spinoff test was performed to investigate the adhesion and removal capability of a particle to disk surface. Numerical simulation was also performed to investigate dominant factor of particle detachment and to support experimental results. It was shown that particles are detached from the disk surface by the moment derived from the centrifugal force and the drag force and that the centrifugal force and capillary force are the dominant force, which determines spin-off of a particle on the disk surface. Removal of particles smaller than several micrometers, which are the main source of TA generation, is extremely difficult since the adhesion forces exceed the centrifugal force. Lubricant types and manufacturing process also influence the particle removal. Lower bonding ratio and lower viscosity of the lubricant will help to increase the removal rate of the particles from the disk surface.