• Title/Summary/Keyword: MQM

Search Result 7, Processing Time 0.018 seconds

Static and Dynamic Analyses of Bending Problems Using 3-Dimensional 10-Node Equivalent Element (3차원 10절점-상당요소에 의한 굽힘문제의 정적.동적해석)

  • 권영두;윤태혁
    • Computational Structural Engineering
    • /
    • v.10 no.4
    • /
    • pp.117-130
    • /
    • 1997
  • In this paper, a modified 10-node equivalent solid element(MQM10 element), which has smallest degrees of freedom among 3-dimensional solid elements accounting bending deformation as well as extensional and shear deformations of isotropic plates, is proposed. The proposed MQM10 element exhibits stiffer bending stiffness due to the reduction of degrees of freedom from 20-node element or Q11 element. As an effective way to correct the relative stiffness stiffening phenomenon, the modification equation of Gauss sampling points is proposed. The quantity of modification is a function of Poisson's ratio. The effectiveness of MQM10 element is tested by applying it to several examples. It is noted that the results of static and free vibration analysis of isotropic plates using MQM10 elements show a good agreement with those using 20-node element.

  • PDF

Quality Monitoring Comparison of Global Positioning System and BeiDou System Received from Global Navigation Satellite System Receiver

  • Son, Eunseong;Im, Sung-Hyuck
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.7 no.4
    • /
    • pp.285-294
    • /
    • 2018
  • In this study, we implemented the data quality monitoring algorithm which is the previous step for real-time Global Navigation Satellite System (GNSS) correction generation and compared Global Positioning System (GPS) and BeiDou System (BDS). Signal Quality Monitoring (SQM), Data QM, and Measurement QM (MQM) that are well known in Ground Based Augmentation System (GBAS) were used for quality monitoring. SQM and Carrier Acceleration Ramp Step Test (CARST) of MQM result were divided by satellite elevation angle and analyzed. The data which are judged as abnormal are removed and presented as Root Mean Square (RMS), standard deviation, average, maximum, and minimum value.

Objectively Predicting Ultimate Quality of Post-Rigor Pork Musculature: II. Practical Classification Method on the Cutting-Line

  • Joo, S.T.;Kauffman, R.G.;Warner, R.D.;Borggaard, C.;Stevenson-Barry, J.M.;Rhee, M.S.;Park, G.B.;Kim, B.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.1
    • /
    • pp.77-85
    • /
    • 2000
  • To investigate the practical assessing method of pork quality, 302 carcasses were selected randomly to represent commercial conditions and were probed at 24 hr postmortem (PM) by Danish Meat Quality Marbling (MQM), Hennessy Grading Probe (HGP), Sensoptic Resistance Probe (SRP) and NWK pH-K21 meter (NpH). Also, filter paper wetness (FPW), lightness (L*), ultimate pH (pHu), subjective color (SC), firmness/wetness (SF) and marbling scores (SM) were recorded. Each carcass was categorized as either PSE (pale, soft and exudative), RSE (Reddish-pink, soft and exudative), RFN (reddish-pink, firm and non-exudative) or DFD (dark, firm and dry). When discriminant analysis was used to sort carcasses into four quality groups the highest proportion of correct classes was 65% by HGP, 60% by MQM, 52% by NpH and 32% by SRP. When independent variables were combined to sort carcasses into groups the success was only 67%. When RSE and RFN groups were merged so that there were only three groups (PSE, RSE+RFN, DFD) differentiating by color MQM was able to sort the same set of data into the new set of three groups with 80% accuracy. The proportions of correct classifications for HGP, NpH and SRP were 75%, 61% and 35% respectively. There was a decline in predication accuracy when only two groups, exudative (PSE and RES) and non exudative (RFN and DFD) were sorted. However, when two groups designated PSE and non-PSE (RSE, RFN and DFD) were sorted then the proportion of correct classification by MQM, HGP, SRP and NpH were 87%, 81%, 71% and 66% respectively. Combinations of variables only increased the prediction accuracy by 1 or 2% over prediction by MQM alone. When the data was sorted into three marbling groups based on SM this was not well predicted by any of the probe measurements. The best prediction accuracy was 72% by a combination of MQM and NpH.

Objectively Predicting Ultimate Quality of Post-Rigor Pork Musculature: I. Initial Comparison of Techniques

  • Joo, S.T.;Kauffman, R.G.;Warner, R.D.;Borggaard, C.;Stevenson-Barry, J.M.;Lee, S.;Park, G.B.;Kim, B.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.1
    • /
    • pp.68-76
    • /
    • 2000
  • A total of 290 pork loins were selected to include a wide variation of quality to investigate the quality categories into which most pork falls, selection criteria for these categories and methods to objectively assess ultimate pork quality. They were probed at 24 h postmortem (PM) for the following: A) light reflectance by Danish Meat Quality Marbling (MQM), Hennessy Grading Probe (HGP) and Sensoptic Invasive Probe (SIP); B) electrical properties by NWK LT-K21 conductivity (NLT) and Sensoptic Resistance Probe (SRP): and C) pH by NWK pH-K21 (NpH). Also, measurements of % drip loss (PDL) and filter paper wetness (FPW), color brightness (L*), ultimate pH (pHu), lipid content, subjective color (SC), firmness/wetness (SF) and marbling scores (SM) were assessed. Each loin was categorized as either pale, soft and exudative (PSE), reddish-pink, soft and exudative (RSE), reddish-pink, firm and non-exudative (RFN) or dark, firm and dry (DFD). Statistically comparing coefficients of determination (CD), the results indicated that overall, the HGP predicted quality groups slightly better than MQM (CD=71 and 62% respectively), NpH and SRP were less effective (CD= 56 and 44% respectively), and SIP and NLT had the lowest values (CD=36 and 5% respectively). Combining various independent variable did not greatly improve the variation accounted for. When the data was sorted into marbling groups based on lipid content, this was not accurately predicted by any of the probe measurements. The MQM probe remained the best predictor for marbling class and accounted for about 25% of the lipid content variation. This was slightly improved to 33% when pHu was combined with MQM.

Static and Dynamic Analyses of Pure Bending Problems of Composite Plates using Non-Conforming 3-Dimensional 8-Node Solid Element (3차원 8절점 비적합 고체요소에 의한 복합재판의 순수굽힘문제의 정적.동적해석)

  • Yun, Tae-Hyeok;Gwon, Yeong-Du
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.2 s.28
    • /
    • pp.1-21
    • /
    • 1998
  • In this paper, a non-conforming 3-D 8-node solid element(MQM10) has beets applied to the analyses of static and dynamic bending problems of laminated composite plates The QM10 element exhibits stiffer bending stiffness which is caused by the reduction of degree of freedom from Q11 element. As an effective way to correct the relative stiffness stiffening phenomenon the modification of Gauss sampling points for composite plates is proposed. The quantity of modification is a function of material properties. Also, another two modified equations are obtained, one is modification for stress, and the other is modification of coefficient of shear modulus in free vibration. It is noted that MQM10 element can analyse the static and free vibration problems of various 3-dimensional composite plates composed of unidirectional laminae, woven laminae or braided laminae. The results of MQM10 element are in good agreement with those of 20-node element.

  • PDF

Impact Ionization Rates of Electron in GaAs/AlGaAs Qunantum Well Using EMC Simulation (EMC Simulation을 이용한 GaAs/AlGaAs 양자 우물 내 전자의 충돌 이온화율)

  • 윤기정;홍창희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.11a
    • /
    • pp.221-225
    • /
    • 1994
  • We described the impact ionization rates of electron in GaAs/AlGaAs MQH(multi- quantum well) using EMC(ensenble Monte Carlo) simulation. Hot electron energy of injected into quantum well is increasing nearly liearly due to the applied electric field to the barrier of MQM inspite of various Al mole fraction in AlGaAs or barrier width. Impact ionization rates are decreasing exponentially by increasing Al mole fraction, and they have peak vague due to the barrier width.

A Monitoring Method of Code, Carrier and Navigation Message for Marine Local Area DG PS (해양 분야 DGPS를 위한 코드, 반송파, 항법 메시지 검사 기법)

  • Kim, Jeong-Won;Jang, Han-Jin;Kim, Tae-Ho;Son, Seok-Bo;Hwang, Dong-Hwan;Lee, Sang-Jeong;Park, Chan-Sik;Suh, Sang-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2567-2569
    • /
    • 2005
  • 본 논문에서는 해양분야에 적용 가능한 GPS(Global Positioning System) 코드, 반송파, 항법 메시지 감시 기법을 제안한다. GPS를 구성하고 있는 위성, 지상 제어국, 사용자부에 내재한 고장 요인들에 대하여 분석하고 이를 바탕으로 각 고장에 대응할 수 있는 검사기법들을 제시한다. 제시하는 검사기법은 DGPS 기준국에서 수행할 수 있는 검사 기법으로 신호 감시 기법(SQM, Signal Quality Monitoring), 데이터 감시 기법(DQM, Data Quality Monitoring), 측정치 감시 기법(MQM, Measurement Quality Monitoring)으로 구성된다. 해양 분야에 적용을 위하여 해양 분야에서 요구하는 GNSS(Global Navigation Satellite System)에 대한 안전조건을 조사하고 이를 바탕으로 해양 분야에 사용가능한 감시 기법을 제시한다.

  • PDF