• Title/Summary/Keyword: MPR

Search Result 109, Processing Time 0.029 seconds

Analysis of C-shaped root canal configuration in maxillary molars in a Korean population using cone-beam computed tomography

  • Jo, Hyoung-Hoon;Min, Jeong-Bum;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.1
    • /
    • pp.55-62
    • /
    • 2016
  • Objectives: The purpose of this study was to investigate the incidence of root fusion and C-shaped root canals in maxillary molars, and to classify the types of C-shaped canal by analyzing cone-beam computed tomography (CBCT) in a Korean population. Materials and Methods: Digitized CBCT images from 911 subjects were obtained in Chosun University Dental Hospital between February 2010 and July 2012 for orthodontic treatment. Among them, a total of selected 3,553 data of maxillary molars were analyzed retrospectively. Tomography sections in the axial, coronal, and sagittal planes were displayed by PiViewstar and Rapidia MPR software (Infinitt Co.). The incidence and types of root fusion and C-shaped root canals were evaluated and the incidence between the first and the second molar was compared using Chi-square test. Results: Root fusion was present in 3.2% of the first molars and 19.5% of the second molars, and fusion of mesiobuccal and palatal root was dominant. C-shaped root canals were present in 0.8% of the first molars and 2.7% of the second molars. The frequency of root fusion and C-shaped canal was significantly higher in the second molar than the first molar (p < 0.001). Conclusions: In a Korean population, maxillary molars showed total 11.3% of root fusion and 1.8% of C-shaped root canals. Furthermore, root fusion and C-shaped root canals were seen more frequently in the maxillary second molars.

- A Case Study on OOP Component Build-up for Reliability of MRP System - (MRP 시스템의 신뢰성을 위한 객체재향 컴포넌트 개발 사례)

  • Seo Jang Hoon
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.3
    • /
    • pp.211-235
    • /
    • 2004
  • Component based design is perceived as a key technology for developing advanced real-time systems in a both cost- and time effective manner. Already today, component based design is seen to increase software productivity, by reducing the amount of effort needed to update and maintain systems, by packaging solutions for re-use, and easing distribution. Nowdays, a thousand and one companies in If(Information Technology) industry such as Sl(System Integration) and software development companies, regardless of scale of their projects, has spent their time and endeavor on developing reusable business logic. The component software is the outcome of software developers effort on overcoming this problem; the component software is the way propositioned for quick and easy implementation of software. In addition, there has been lots of investment on researching and developing the software development methodology and leading If companies has released new standard technologies to help with component development. For instance, COM(Component Object Model) and DCOM(Distribute COM) technology of Microsoft and EJB(Enterprise Java Beans) technology of Sun Microsystems has turned up. Component-Based Development (CBD) has not redeemed its promises of reuse and flexibility. Reuse is inhibited due to problems such as component retrieval, architectural mismatch, and application specificness. Component-based systems are flexible in the sense that components can be replaced and fine-tuned, but only under the assumption that the software architecture remains stable during the system's lifetime. In this paper, It suggest that systems composed of components should be generated from functional and nonfunctional requirements rather than being composed out of existing or newly developed components. about implements and accomplishes the modeling for the Product Control component development by applying CCD(Contract-Collaboration Diagram), one of component development methodology, to MRP(Material Requirement Planning) System

DC-Suppression Selection Criteria of Multimode Modulation Code for Optical Recording (광 기록 시스템을 위한 멀티모드 변조 코드의 DC-억압 코드 선택 방법)

  • Lee, Myoung-Jin;Lee, Jun;Lee, Jae-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.3C
    • /
    • pp.209-214
    • /
    • 2003
  • Multi-mode coding method is a reliable DC-suppression method. There are two ways to improve the DC-suppression performance. One is improving scrambler's performance, and the other is improving selection criteria. The latter uses the MRDS(minimum running digital sum) criterion. It is easy to calculate, but its performance goes down when the length of codeword is getting longer. The MSW(mean squared weight) criterion that is known as the best so far regardless of the length of codeword has the high complexity. In this paper, we present the new selection criteria, MPRDS(minimum peak RDS) and A BSRDS(absolute RDS). Their performance are close to the MSW, implementation is simple. And also we present the SC(sign change) that has a subsidiary role with the original selection criteria and improve the capacity.

Three Dimensional Reconstruction on Computed Tomograms of Fish Bones (생선가시의 전산화 단층촬영 자료에 삼차원 재구성법을 적용한 연구)

  • Park, Joong Hyun;Woo, Kuk Sung;Yoo, Young Sam;Kim, Dong Won;Lee, Han Bee
    • Korean Journal of Bronchoesophagology
    • /
    • v.18 no.2
    • /
    • pp.49-55
    • /
    • 2012
  • Background and Objectives This study was conducted to gather three dimensional images from computed tomogram in detecting and gaining information about fish bones. Materials and Methods Thirty-nine fish bones and 2 chicken leg bones were used. Bones sandwiched between the cotton sheets were placed into the 3 plastic boxes. Computed tomogram of the bones in the boxes were reconstructed three-dimensionally by Xelis (Infinitt, Korea) to make images of MPR, MIP and VR images. The images were compared with real chicken bones and fish bones as to possibility of detection, finding of location and orientation, and evaluation of shape and calculation of size. Results All 41 bones were detected in all reconstructed images. Distance to the bones from reference point can be measured and orientation can be checked. Shapes were similar between matched images of all real bones. Conclusion The results indicate the usefulness of 3D reconstruction technique in getting informations about fish bones.

  • PDF

A Study of the Employee's Attitude Toward Operation of the Hospital Material Requirements Planning System(HMRPS) in University Hospitals (병원 종합 물류시스템 운영에 대한 관련직원들의 인식)

  • Lee, Kwang-Yong;Yu, Seung-Hum;Sohn, Tae-Yong
    • Korea Journal of Hospital Management
    • /
    • v.4 no.2
    • /
    • pp.266-285
    • /
    • 1999
  • The purpose of this study is to identify influencing factors for successful introduction, implementation and management of HMRPS through assessment of the employees attitude toward HMRPS in technical, administrative, and organization behavioral areas. Data were collected from 157 HMRPS employee members' self-reporting questionnaire in three university hospitals in the city of Seoul and Kyonggi Province from November 5 to November 10, 1997. Relevant literature on industry company MPR system theory was reviewed to develop the theoretical framework. The results were as follows: The employee's recognition of tangible benefit were more significantly influenced success than intangible benefit for successful operation relating the HMRPS. Concerning the employee's recognition of the successful HMRPS and the factor of influenced success was significantly positive correlation between tangible and intangible benefits and success factor in technical, administrative, and organizational behavior area. This study showed that major factor affecting the employee's recognition of tangible and intangible benefit for successful HMRPS. For tangible benefits; Success factors in the technical areas were quality of the data and information, efficiency of inventory management and rescheduling of operation plan. Success factors in the administrative areas were: role of top management. Success factors in the organization behavioral areas were; simplicity of the HMRPS, human resistance to change. For intangible benefits; Success factors in the organization behavioral areas were; user involvement, simplicity of HMRPS, human resistance to change. Futhermore as the exact evaluation of successful factors of HMRPS implement is needed, research for the development of systemic variables of physical distribution system control, methods, capacity of system, duration and other environment in many of 30 hospitals or more, and for the empirical study for HMRPS.

  • PDF

The Effect of the Axial Plane on Measurement of Available Bone Height for Dental Implant in Computed Tomography of the Mandible (하악의 전산화 단층사진에서 횡단면이 임플랜트를 위한 가용골 높이의 결정에 미치는 영향)

  • Jhin, Min-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.379-388
    • /
    • 2002
  • For the success of dental implant, accurate radiographic evaluation is prerequisite for planning the location of the osseointegrated implants and avoiding injury to vital structures. CT/MPR(computed tomography/multiplanar reformation) shows improved visualization of inferior alveolar canal. In order to obtain cross-sectional images parallel to the teeth, the occlusal plane is used to orientate for the axial plane. If the direction of axial plane is not parallel to the occlusal plane, the reformatted cross-sectional scans will be oblique to the planned fixture direction and will not show the actual dimension of the planned fixture's location. If the available bone height which measured in the cross-sectional view is much greater than the actual available bone height, penetration of canal may occur. The aim of this study is to assess the effect of the axial plane to measurement of available bone height for dental implant in computed tomography of the mandible. 40 patients who had made radiographic stents and had taken CT were selected. The sites that were included in the study were 45 molar regions. In the central panoramic scan, the length from alveolar crest to superior border of inferior alveolar canal(available bone height, ABH) was measured in direction of reformatted cross-sectional plane(uncorrected ABH). Then, length from alveolar crest to superior border of canal was measured in direction of stent(corrected ABH). The angle between uncorrected ABH and corrected ABH was measured. From each ABH, available fixture length was decided by $Br{{\aa}}nemark$ system. The results were following ; the difference between two ABHs was statistically significant in both first and second molar(p< 0.01). The percentage of difference more than 1 mm was 8.7% in first molar and 15.5% in second molar. The percentage of difference more than 2 mm was 2.0% in first molar and 6.6% in second molar. The maximum value of difference was 2.5 mm in first molar and 2.2 mm in second molar. The correlations between difference of 2 ABHs and angle was positive correlations in both first and second molar. The correlation coefficient was 0.534 in first molar and 0.728 in second molar. The second molar has a stronger positive correlation. The percentage of disagreement between 2 fixture lengths from two ABHs was 24.4% in first molar and 28.9% in second molar.

Radiographic examination of the Osseous Abnormalities of the Mandibular Condyle Using Cone Beam Computed Tomography (Cone Beam CT를 이용한 하악 과두의 골 이상에 대한 방사선적 분석)

  • Kim, Yu-jin;Kim, Yun-sang;Kim, Min-jeong;Sim, Hun-Bo;Oh, Sang-chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.211-224
    • /
    • 2009
  • The objective of this study is to examine the condylar surfaces in order to find out the types, the incidence and common occurrence area of the osseous abnormalities of the condyles according to the age, genders and the purpose of CT taking, and to compare those between the groups for TMD diagnosis and the other groups. 3D CT images of 199 patients which were scanned with the $i-CAT^{TM}$ Cone Beam Computed Tomography were collected from Sanbon Dental Hospital of Wonkwang university and the MPR images were transfered to the TMJ mode to be showed serial sagittal images and coronal images. The images were macroscopically examined by three independent observers for the types and incidences of the osseous abnormalities, their common occurrence area and general shapes of the condyles. As a result, type F is most common ever than type N. The common occurrence area in sagittal images is antero-superior and superior area except for type D-C which were showed on postero-superior area commonly. In coronal images, latero-superior and superior area is most common except for type E which were present on mesio-superior and superior area most frequently. The osseous abnormalities of the condyles are more common in TMD diagnosis group except for type D-C, that is type N and type D-C are more common in the other groups. In this study, abnormalities of the condyles are classified into 6 types and it has a common occurrence area each. And TMD diagnosis group shows a tendency to have higher rate for osseous abnormalities except for type D-C.

Correlation between menton deviation and dental compensation in facial asymmetry using cone-beam CT (Cone-beam CT를 이용한 안면비대칭자에서 이부편위에 따른 치성보상의 양상분석)

  • Park, Soo-Byung;Park, Jeong-Heuy;Jung, Yun-Hoa;Jo, Bong-Hye;Kim, Yong-Il
    • The korean journal of orthodontics
    • /
    • v.39 no.5
    • /
    • pp.300-309
    • /
    • 2009
  • Objective: The purpose of this study was to evaluate the correlation between menton deviation and dental compensation in facial asymmetry. Methods: Tooth axis and distance of first molar and canine to the reference plane were investigated by cone-beam computerized tomography. The subjects consisted of 50 patients with asymmetric mandibles (male 21, female 29, mean age 24.3 years). Control groups were also assessed (male 11, female 9, mean age 25.6 years). Nine measurements (5 linear measurements and 4 angular measurements) were measured in order to evaluate the correlation between menton deviation and the linear and angular difference of first molar and canine in the deviated and none-deviated sides using the defined MPR images. The differences between deviated and non-deviated side, according to menton deviation, were statistically analyzed using stepwise multiple regression analysis. Results: From the result, Menton deviation was negatively correlated with mandibular first molar's angular measurement (${\Delta\angle}LM6$-Mn plane (dev.-ndev.)) and positively with maxillary fist molar's angular measurement (${\Delta\angle}UM6$-FH plane (dev.-ndev.)) (p < 0.01). Two angular measurements (${\Delta\angle}LM6$-Mn plane (dev.-ndev.), ${\Delta\angle}UM6$-FH plane (dev.-ndev.)) explained the variability in menton deviation with a significant $r^2$ value of 0.589. Conclusions: This study suggests that the tooth axis of upper and lower first molars leans towards the deviated side of Menton when there is mandibular asymmetry with Menton deviation.

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.

Analysis of Impacts of Aggressive Driving Events on Traffic Stream Using Driving and Traffic Simulations (주행 및 교통 시뮬레이션을 이용한 공격운전이 교통류에 미치는 영향 분석)

  • PARK, Subin;KIM, Yunjong;OH, Cheol;CHOI, Saerona
    • Journal of Korean Society of Transportation
    • /
    • v.36 no.3
    • /
    • pp.169-183
    • /
    • 2018
  • Aggressive driving leads to a greater crash potential because it threatens surrounding vehicles. This study conducted traffic simulation experiments using driving behavior data obtained from multi-agent driving simulations. VISSIM traffic simulator and surrogate safety assessment model (SSAM) were used to identify the impacts of aggressive driving on traffic stream in terms of safety and operational efficiency. Market penetration rates (MPR) of aggressive driving vehicle, coupled with various traffic conditions, were taken into consideration in analyzing the impacts. As expected, it was identified that aggressive driving vehicles tended to deteriorate the traffic safety performance. From the perspective of operational efficiency, interesting results were observable. Under level of service (LOS) A, B, and C, it was observed that the average travel speed increased with greater MPRs. Conversely, the average travel speed decreased with under LOS D and E conditions. The outcome of this study would be effectively used for developing safety-related policies for reducing aggressive driving behavior.