• Title/Summary/Keyword: MOV

Search Result 89, Processing Time 0.023 seconds

Design of Position Controller for Proportional Solenoid Valve Using System Identification (시스템 식별을 이용한 비례솔레노이드밸브 위치제어기 설계)

  • Jung, G.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.4
    • /
    • pp.23-31
    • /
    • 2010
  • As the analysis and design technologies for electro-magnetic actuation has advanced over the years, proportional solenoid valve is gaining acceptance in wide range of industrial and commercial applications because of its superior characteristics over the conventional AOV or MOV, such as improved performance, reduced maintenance costs. This research deals with the position controller design of two-stage flow control solenoid valve. Investigation of steady-state characteristics and dynamic model identification for pilot disc is performed. Least square method to minimize the error magnitude of frequency response between the closed-loop and target system is applied to the design of PI-controller gains. From the experiments of step and frequency response, it is concluded that the controller meets the performance specification of target system, which verifies the usefulness of controller design method for proportional solenoid valve.

  • PDF

Developemet of noncontact velocity tracking algorithm for 3-dimensional high speed flows using digital image processing technique (디지털 화상처리를 이용한 유동장의 비접촉 3차원 고속류 계측법의 개발)

  • 도덕희
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.259-269
    • /
    • 1999
  • A new algorithm for measuring 3-D velocity components of high speed flows were developed using a digital image processing technique. The measuring system consists of three CCD cameras an optical instrument called AOM a digital image grabber and a host computer. The images of mov-ing particles arranged spatially on a rotation plate are taken by two or three CCD cameras and are recorderd onto the image grabber or a video tape recoder. The three-dimensionl velocity com-ponents of the particles are automatically obtained by the developed algorithm In order to verify the validity of this technique three-dimensional velocity data sets obtained from a computer simu-lation of a backward facing step flow were used as test data for the algorithm. an uncertainty analysis associated with the present algorithm is systematically evaluated, The present technique is proved to be used as a tookl for the measurement of unsteady three-dimensional fluid flows.

  • PDF

Design and Fabrication of a Transient Voltage Stocking Device for Electrical Mains (전원회로용 과도전압 차단장치의 설계 및 제작)

  • 이종혁;송재용;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.11a
    • /
    • pp.486-489
    • /
    • 1999
  • This paper deals with the design rule and performance results of the transient voltage blocking devices (TBD) for low-voltage mains on shipboard. The proposed TBD consists of metal oxide varistors (MOV) and L-C filter to improve noise-elimination performance. Three kinds of TBDs are fabricated and tested by using a combination surge generator which can produce the standard impulse current of 8/20${\mu}$s 2.1kA. As a reults, the proposed TBD with series L-C filter has more excellent transient blocking and noise reduction performance than the conventional TBDs.

  • PDF

Experimental Study on Temporary Overvoltage Characteristic of Surge Protective Devices (서지보호기의 일시과전압특성에 대한 실험적 연구)

  • Shim, Hae-Sup;Jeon, Tae-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.344-347
    • /
    • 2009
  • Surge protective devices (SPD) have a special position because of the expectation that they perform an effective protective function against various kinds of surges. However, there exists a misconception that the SPD satisfying lower measured limiting voltage (MLV) should also protect equipment against temporary overvoltages (TOVs) as well. This paper inspects various types of MOV based SPDs and carry out experiments on the side effects of the low MLV characteristics. The experiment results show that a low MLV could cause a higher TOV-induced SPD failure rate in the field.

  • PDF

Critical Temperature for Grain Filling of Japonica Rice in Korea (우리나라 자포니카 벼 품종의 등숙 한계온도 분석)

  • Woonho Yang;Shingu Kang;Dae-Woo Lee;Mi-jin Chae
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.68 no.4
    • /
    • pp.225-235
    • /
    • 2023
  • Critical temperature for grain filling of three Korean japonica rice varieties was analyzed by late transplantation to induce a low temperature during grain filling period in a field study. The grain filling percentage (GFP) and grain dry weight (GDW) showed a sigmoid development for the first and second transplants in 2020 and first to third transplants in 2021. For the third transplant in 2020 and fourth transplant in 2021, the GFP and GDW reached a peak at 42 days after heading (DAH), and then decreased or remained unchanged. In non-linear regression analyses, 95% of the final GFP and GDW appeared at 49 - 62 DAH for the second transplant in 2020 and at 37 - 46 DAH and 30 - 36 DAH for the second and third transplants in 2021, respectively. At these time points, the critical seven-day moving temperature (7dMovT) was 8.4~9.4℃ for the second transplant in 2020 and 9.4~10.9℃ for the second and third transplants in 2021, depending on the grain filling traits and varieties of rice. The lowest 7dMovT was 8.4 - 8.7℃ in the three varieties. The observed lowest 7-day mean temperature (7dMT) accompanying increases in the GFP and GDW was 9.4 - 10.1℃, depending on the varieties in the third transplant of 2020 and fourth transplant of 2021. In the two transplants mentioned above, the highest 7dMT that showed no increase or decrease in grain filling traits was 8.7 - 9.1℃. The critical temperature for grain filling of japonica rice was 8.4 - 8.7℃ based on the 7dMovT and 9.1 - 9.4℃ based on the 7dMT. The previous 7dMT of 10℃ is recommended to determine the marginal harvest time for safe rice cropping since the temperature was the highest among the lowest temperature that accompanied an increase in grain filling traits.

Creep Crack Growth Properties of Low Pressure Turbine Rotor Steel under Constant Load and Ct

  • Jeong, Soon-Uk
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.3 no.2
    • /
    • pp.95-101
    • /
    • 2002
  • The propagation rate(da/dt) prediction parameter and the microstructure properties of creep crack in domestic 3.3NiCrMov steel were investigated at 550$\^{C}$ by using 0.5" CT specimen under constant load(4090N) and constant Ct(300∼4000N/mhr) condition that was maintained during crack growth of 1mm distance. C* usually increased with crack length though load was reduced in order to maintain constant Ct value as crack growth and considerably showed the scatter band, but Ct depended on load line displacement rate and represented a good relation with da/dt. At constant toad and Ct region, crack growth slope was 0.900 and 0.844 each, in the other hand C* slope was 0.480. Fully coalesced area(FCA) ahead of crack tip was increased as Ct value increase to the critical value, and after that value FCA decreased. The average diameter ditribution of cavity in FCA showed the greatest value about 1.5 ㎛ when Ct=2000N/mhr. The increasing of Ct in FCA view point enlarged the size of damage area and the size reached to maximum 800 ㎛ when Ct=2000N/mhr.

Study on the Rate-of-Loading by the Differential Pressure of Motor Operated Gate Valves in Opening Stroke (모터구동 게이트밸브의 열림행정시 차압 작용에 의한 부하율 연구)

  • Kim, Bum-Nyun;Hong, Sung-In
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.6
    • /
    • pp.35-41
    • /
    • 2007
  • The rate of loading in motor operated valve(MOV) can be defined as a variation of correlation between the actuator torque and the thrust upon the variation of operating load. This paper contains the analysis of characteristic and the validity of loading rate in the opening stroke of gate type motor operated valve. Also, this paper describes the evaluation result of loading rate for 40 MOVs' opening stroke using newly derived methodology in this study. Author has found a result that loading rate of opening stroke gets a negative value when the differential pressure is higher than 150 psi and this value goes up depending on the amount of the differential pressure.

A DSP Platform for the HD Multimedia Streaming (HD급 멀티미디어 Streaming을 위한 DSP 플랫폼)

  • Hong, Keun-Pyo;Park, Jong-Soon;Moon, Jae-Pil;Kim, Dong-Hwan;Chang, Tae-Gyu
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.569-572
    • /
    • 2005
  • This paper proposed the design and implementation of a DSP platform for the various multimedia streaming. The DSP platform synchronizes with host PC to configure DSP and to transmit multimedia streaming through PCI. The suggested DSP platform decodes high-capacity video/audio data using the suggested high-speed FIFO, CPLD and memory interface. The buffer control techniques is proposed in other to avoid the under/over-run of the audio/video data during the audio/video decoding. For the DSP platform test, host PC transmits program stream(PS) that consists of the MPEG-2 video MP@ML and 5.1ch AC3 audio data (Coyote.mov file, half hour running time) to DSP platform. The DSP platform plays continuously back the high sound-quality audio and high-definition video at once.

  • PDF

Development of Integrity Evaluation Instrument for the Power Line Surge Protective Device (전원용 SPD의 건전성 평가 장치 개발)

  • Chang, Sughun;Kim, Youngjin;Kim, Sungju;Kim, Jaehyung
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.39-45
    • /
    • 2015
  • This paper deals with development of integrity evaluation instrument for the power line surge protective device. A reliable power supply is an essential element in the developed information and communication society by highly advances in IT technology. However, the lightning incidence also increased with the recent extreme weather events. In Korea, in order to protect the electrical system from lightning surge, SPD(Surge Protective Device) has been used for these past 30 years. However, the method of diagnosing the safety of the SPD in the industry is insufficient. In this paper, SPD integrity evaluation system was composed of a variable DC power source unit, voltage-current sensor and the embedded controller. In order to measure V-I characteristics of MOV, 3 type samples were degraded by impulse current generator. After impulse tests, the varistor voltage of all samples and nonlinearity coefficient were decreased. It confirmed the utility of the developed equipment by this experimental test and the reliability of SPD is expected for surge accident prevention when applied to industrial plant.

3-D Finite Element Stress Analysis for Fatigue Design and Evaluation;A Parametric Study of MOV(Motor Operated Valve) (피로설계 및 평가를 위한 3차원 유한요소 응력해석에 관한 고찰;모터구동밸브를 이용한 사례연구)

  • Kim, Hyeong-Keun;Lee, Sang-Min;Chang, Yoon-Suk;Choi, Jae-Boong;Kim, Young-Jin;Kim, Yun-Jae
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.142-147
    • /
    • 2004
  • In this paper, a new procedure is proposed to accomplish the primary plus secondary stress(P+Q) at the 'structural element' instead of 'transition element'. For the P+Q evaluation, the calculated stresses by FEA are linearized along a stress classification line to extract the stress category, then the stress intensity is calculated to compare with the $3S_{m}$ limit. Also, in this paper, the 'design by analysis' criteria, adopted fundamental concepts and a new approach to calculate $K_{e}$ factors are explained. The new procedure combined with 3-D FEA has been applied to motor operated valve in order to the over conservatism and the rack of margin. The evaluation results show a good applicability and can be utilized for fatigue life evaluation by using P+Q.

  • PDF