• Title/Summary/Keyword: MOF

Search Result 217, Processing Time 0.023 seconds

Clinical Experiences of Multiple Organ Failure after Surgery for Acquired Cardiovascular Disease

  • 김병열
    • Journal of Chest Surgery
    • /
    • v.23 no.2
    • /
    • pp.275-284
    • /
    • 1990
  • A serious problem after cardiovascular surgery known as Multiple Organ Failure[MOF] whereby several vital organs successively demonstrate dysfunction in spite of intensive postoperative treatment has recently arisen. We have made a retrospective study of the clinical records of 137 patients who underwent cardiovascular surgery during past two years [1987-1988]. Fourteen patients [10%] developed multi-organ failure postoperatively with the results of seven death [50%]. In fatal group, preoperative poor cardiac function [Cardiac Index<2.0L/min/m2] was considered important prognostic factor and infection 5 disseminated intravascular coagulation complicating gastrointestinal bleeding were the leading cause of death. In conclusion, evaluation of multiple factors concerning multi-organ failure demonstrates preoperative poor functional preservation of vital organs is the main factor. So early diagnosis k management for each of the failing organs & prevention of infection are mandatory of the treatment of these critically ill patients.

  • PDF

Problem Analysis by Iron Core Structure of the Transformer on Asymmetric three Phase lines and Prevention Measures (비대칭 3상 선로에서 변압기의 철심구조별 문제점 분석 및 방지대책)

  • Shin, Dong-Yeol;Yun, Dong-Hyun;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1536-1541
    • /
    • 2012
  • The study analyzed problems by iron core structure of the three phased transformer on asymmetric three phase lines, which included line disconnections, ground faults, COS OFF, and unbalanced loads on the power distribution system. In particular, by analyzing PT combustion cases within the MOF, the study was able to analyze the combustion cause of the core-type transformer and its effect on the system, conduct simulations and practice demonstrations on the characteristics for each iron core structure of the three phase transformer using PSCAD/EMTDC, and suggest measures to prevent the combustion of the core-type transformer.

Risk Analysis of Electrical Fire for Electric Power Installations by Event Tree Analysis (사건수목분석을 통한 수배전설비의 전기화재위험성 분석)

  • Park, Young Ho;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.16-21
    • /
    • 2016
  • The purpose of this paper is to conduct ETA on 15 components of power installations: the DS/LBS, LA, MOF, CT, PT, A/V meter, VCB, OCR, COS, PF, Transformer, Condenser(C), Grounding, Cable and Connector. To achieve that, power installations work flow and its components are categorized. Based on performance, human, environmental, management, and safety, this paper drew Initiation events (IE) and End states (ES). ETA is applied to the main functions of each component, and the end states that may occur in one initiation event are suggested. In addition, detailed classification was performed to induce various end states on the basis of the suggested initiation events. If the suggested IEs and ESs are applied on the basis of power installations event cases, it is expected to prevent the same kinds of accident and operate power installations safely.

Preparation of Cu2(btc)3-AAO Hybrid Membrane by Layer-by-layer Technique (Layer-by-layer 기법을 통한 Cu2(btc)3-AAO 하이브리드 분리막의 제조)

  • Yoo, Hyeonseok;Choi, Jinsub
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.1
    • /
    • pp.21-26
    • /
    • 2018
  • The $Cu_2(btc)_3$ metal-organic frameworks (MOF) coated anodic aluminum oxide (AAO) membrane was successfully prepared by layer-by-layer technique using hand spray method. It was confirmed that the $Cu_2(btc)_3$ layer, which has the pore sized in 2-3 nm, on surface of AAO exhibited the polycrystalline thin film structure by XRD analysis. More than 100 repetitive spray cycles were required to obtain more robust and thick MOFs on AAO and it was possible to uniformly coat both the top and bottom surfaces of the AAO. It should be noted that the MOFs also could be coated on surface of pores resulting in reduce the size of pore from 52 nm to 32 nm.

Supercapacitor of Auxiliary Electric Power Source in Industrial Safety for High Output (고출력용 산업안전 보조전원의 Supercapacitor)

  • 허진우;강안수
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2003.11a
    • /
    • pp.335-343
    • /
    • 2003
  • In the electrode fabrication of unit cell, it was ascertained that electrochemical characteristics were greatly increased with 90 wt.% of BP-20, 5 wt.% of Super P and 5 wt.% of mixed binder [P(VdF-co-HFP) : PVP =7 : 3] The self-discharge of unit cell showed that diffusion process was controlled by the ion concentration difference of initial electrolyte due to the characteristics of Electric Double Layer Capacitor (EDLC) charged by ion adsorption in the beginning, but this by current leakage through the double-layer at the electrode/electrolyte interface had a minor effect and voltages of curves were remained constant regardless of electrode material. The electrochemical characteristics of 2.3 V/3,000 F grade EDLC were as follows: 0.35 m of DC-ESR (100 A discharge), 0.14 mof AC-ESR (AC amplitude 100 mV), 2.80 Wh/kg (3.73 Wh/L) of energy density and 4.64 kW /kg (6.19 kW/L) of power density. Power output was compatible with electric vehicle applications, uninterrupted power supply and engine starter, in due consideration of Ragone relations.

  • PDF

An Introduction to the Model Driven Architecture (Model Driven Architecture 기술 소개)

  • Kim, W.S.;Kwon, O.C.;Shin, K.S.
    • Electronics and Telecommunications Trends
    • /
    • v.17 no.6 s.78
    • /
    • pp.11-19
    • /
    • 2002
  • 2001년 9월 OMG는 시스템을 명세하고 구축하기 위한 새로운 방안으로 MDA(Model Driven Architecture)를 표준으로 채택하였다. MDA는 OMG가 지금까지 추진한 여러 표준화 작업을 바탕으로 한 모델 중심의 시스템 명세와 개발에 대한 것이다. OMG는 그 동안 CORBA를 통하여 구현 수준에서 기술간 상호 운영성과 시스템 통합을 다루어 왔다. OMG는 여기서 더 나아가 UML, MOF, CWM 등의 모델링 표준화 작업의 결과를 기반으로 한 MDA로 구현 수준에서 설계 수준으로 시스템 통합과 기술간 상호 운영성 문제 해결을 시도한다. 본 고에서는 MDA에 대한 개괄적 설명과 함께 MDA의 기반을 이루는 관련 표준에 대해서 알아보고 그 현재 상황을 살펴본다.

A Novel 3D Polypseudo-rotaxane Metal-organic Framework Based on a Flexible Bis-pyridyl-bis-amide Ligand

  • Wang, Xiu-Li;Han, Na;Lin, Hong-Yan;Xu, Chuang;Luan, Jian;Liu, Guo-Cheng
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3793-3796
    • /
    • 2012
  • A novel 3D compound $\{[Cu(L)(H_2O)_4][Cu_2(SIP)_2(L)_2]\}{\cdot}2H_2O$ (1) (L = N,N-bis(4-pyridinecarboxamide)-1,4-butane, SIP = 5-sulfoisophthalate) is hydrothermally synthesized. X-ray diffraction analysis reveals that compound 1 is composed of 2D anionic $[Cu_2(SIP)_2(L)_2]_n{^{2n-}}$ double-layers and discrete 1D cationic $[CuL(H_2O)_4]_n{^{2n+}}$ polymeric chains, which represents a rare 3D polypseudo-rotaxane MOF from intercalation of 1D and 2D framework. In addition, the luminescent property and electrochemical behavior of compound 1 have been investigated.

특집 : 레이저 기반 초정밀 초고속 가공시스템 - PCB pattern 미세화에 따른 UV laser driller의 개발

  • Park, Hong-Jin;Seo, Jong-Hyeon
    • 기계와재료
    • /
    • v.22 no.1
    • /
    • pp.22-29
    • /
    • 2010
  • 최근 휴대폰 등 모방일 전자기기 산업에서 차세대 고부가 PCB(MLB, HDI, FPC, 등) 및 고기능 PCB(COF, MOF, SOF)의 급속한 적용 확대로 직경$20{\mu}m$급의 비아홀(viahole) 및 interconnection 홀 가공을 위한 초정밀/초고속 레이저 드릴링 공정 및 장비기술 개발에 대한 시장의 요구가 급증하고 있다. 이에 반해 기존의 CO2 레이저 드릴링은 기술적 한계에 도달하여 시장의 요구에 대응이 불가하며, 선진업체에서는 최근 UV 레이저 드릴링 장비에 대한 시장 점유율을 높여가고 있다. 특히 국내시장은 미국의 ESI사가 독점하고 있어 기술개발 투자를 통한 국산화가 절실한 상황이다. 이에 당사에서는 초고속/초정밀 UV laser 시스템을 이용한 FPC iva hole drilling을 연구과제로 개발을 진행하고 있으며 국산화를 넘어서 세계시장점유를 목표로 공정장비개발을 진행중이다.

  • PDF

포항·광주 로란-C 시간동기시스템 구축 결과

  • Kim, Yong-Seok;Seol, Gwang-Cheol
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2019.11a
    • /
    • pp.77-80
    • /
    • 2019
  • GPS 항법 시스템은 재밍(jamming)에 취약한 것으로 알려져 있다. 실제로 2010년부터 북한은 서해상과 수도권에 GPS 전파교란 공격을 감행, 운행 중이던 선박과 항공기의 네비게이션 등에 다수의 장애현상을 유발시켰다. 이것에 대한 대안으로 eLoran(enhanced Long Range Navigation)이 GPS 항법 시스템을 보완할 수 있다고 알려져 있다. 이에 따라 해양수산부(MOF)는 기존 포항·광주 로란-C 송신국에 UTC(Coordinated Universal Time) 기반의 시각동기시스템 구축하여 지상파 eLoran 시스템으로 활용하기 위한 eLoran 사업을 진행하고 있다. 본 논문에서는 기존 포항·광주 로란-C 송신국에 UTC(Coordinated Universal Time) 기반의 시각동기시스템을 구축하기 위한 요구 사항을 살펴보고, 이 요구 사항에 따른 포항·광주 로란-C 시각동기시스템의 구축 결과에 대해 기술하였다.

  • PDF