• Title/Summary/Keyword: MMI

Search Result 253, Processing Time 0.025 seconds

Design of Distributed Control Network system by Using a PIC Micro-processor (PIC Micro-processor를 이용한 분산제어네트워크 설계)

  • Ahn, Pius;Kang, Ki-Won;Kim, Jae-Wook;Kim, Min-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2216-2218
    • /
    • 2001
  • Microchip사의 PIC Family 계열 마이크로프로세서 PIC16C74A를 이용하여 다수의 모터를 on/off 제어하는 컨트롤 보드의 제작과 함께 RS-485 Multi-drop 통신을 이용하여 분산제어 할 수 있는 프로토콜의 선정 및 상위 단 제어 솔루션 개발을 하였다. 프로그램은 하위단 컨트롤보드의 ASM과 함께 Visual BASIC 및 $C^{++}$을 이용하여 상위단 MMI(Man-Machine Interface)를 설계하였다. 본 연구는 여러 개의 장치를 on/off 제어할 수 있는 분산제어네트워크를 경제적으로 설계함으로써 상용화 가능하다는 장점이 있다.

  • PDF

Development of Monitoring System for Guide Roller in Wire Rolling Proces (열연 다운코일러 모니터링 시스템 개발)

  • Son, Boong-Ho;Lim, Eun-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2564-2566
    • /
    • 2001
  • The reliability of EIC(Electricity, Instrumentation and Computer) systems in hot rolling mill is very important in order to maintain stable production. Signals obtained from sensors and control system should be analyzed to monitor the condition of down coiler in hot rolling mill. We develop a monitoring system of down coiler which is composed of three parts : (1) data acquisition and MMI, (2) signal processing and analyzing, and (3) automatic data saving. Also it is designed to enable to inform users the abnormal conditions of down coiler. This developed system is expected to make it possible to reduce long downtime, secure high facility precision, and maintain high control levels.

  • PDF

Development of Educational Simulator for Novel Network Reduction (송전망 축약을 위한 교육용 시뮬레이터 개발)

  • Kim, Hyun-Houng;Lee, Woo-Nam;Kim, Wook;Park, Jong-Bae;Shin, Joong-Rin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1902-1910
    • /
    • 2009
  • This paper presents a graphical windows-based program for the education and training for novel network reduction. The object of developed simulator is to provide users with a simple and useable tool for gaining an intuitive feel for power system analysis. The developed simulator consists of the main module (MMI,GUI), the location marginal price module (LMP), the clustering module and network reduction module. Each module has a separate graphical and interactive interfacing window. The developed simulator needs with the PSS/E input data format, generator cost function, location information. Line admittances of reduced network was determined by using the power flow method(Newton-Raphson). So line flow of reduced network is almost same to original power system. Results of reduced network are compared on the window in the tabular format. Therefore, the developed simulator can be utilized as a useful tool for effective education and training for power system analysis.

A Software Development Plan for Integral Reactor Man-Machine Interface System Design (일체형원자로 MMIS 설계에 적용하기 위한 소프트웨어 개발 계획)

  • 서용석;장귀숙;박근욱;이종복;김동훈
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2001.04a
    • /
    • pp.610-612
    • /
    • 2001
  • 디지틀 중심의 원자로 제어시스템 설계에서 소프트웨어 안전성이 중요한 현안으로 부각되고 있다. 컴퓨터기반의 디지틀시스템으로 설계되는 일체형원자로 MMIS에 적용하기 위한 소프트웨어 개발 계획은 이러한 현안을 만족하기 위해 개발할 필요가 있다. 본 논문은 소프트웨어 개발 계획을 소프트웨어 수명주기 설정, 정형화 기법 적용, 위해서도 분석 수행, 소프트웨어 시험 방법을 제시하였다. 본 논문에서 제시된 소프트웨어 개발 계획은 고품질의 소프트웨어 생산을 보장하며, 원자력 규제기관에서 요구하는 소프트웨어 안전성 보장 계획에 대한 규제사항을 만족한다. 본 논문의 소프트웨어 개발 계획을 바탕으로 추후 구체적인 수행방법, 지침, 절아, 문서화 등의 점차적으로 개발되어 일체형원자로 MMIS 소프트웨어 개발시 적용할 예정이다.

  • PDF

Design of Automatic Generation Control for Jeju EMS (제주 EMS의 자동발전제어 기능의 설계)

  • Lee, J.H.;Moon, Y.H.;Kim, P.S.;Kim, Y.H.;Lee, W.S.;Jang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.164-166
    • /
    • 2003
  • 본 논문은 제주도에 신설되는 제주급전소 EMS/SCADA 기능의 일부인 자동발전제어(AGC) 기능의 설계 내용을 제시한다. 제주 EMS의 자동발전제어(Automatic Generation Control(AGC)) 기능은 지역으로 구분된 계통에서 전력수요를 만족시키기 위해 지역 내의 발전소 유효전력 출력을 제어하는 계통급전센터의 온-라인 응용 소프트웨어이다. 본 논문에서는 제주 EMS에 적용된 AGC 기본 알고리즘과 운영자 편의를 위한 MMI 설계를 보여준다.

  • PDF

Graphic Simulator for processing test of Humanoid Robot (인간형 로봇의 동작 더스트를 위한 그래픽 시뮬레이터)

  • Hwang, Byung-Hun;Kim, Jee-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2480-2482
    • /
    • 2003
  • As make a simulator including user interface functions like start & stop, load parameters, record and save, view 3D display has a real-like length and numerical value of sizes, represent real-shape of inner and outer part of robot, make the possible fast and slow selective observation as a adjust a step, receiving the images through the image device which attached in robot, so make a motion tester simulator of humanoid robot which coded by windows based GUI(Graphic User Interface) program with a MMI(Man Machine Interface) function that user can watch the environment which included robot and use a images. For implement this, we use a design data that converted data which made by use a CAD for Laser RP(Rapid Prototyping) progress into C coding for simulator programming. Using OpenGL, an API of graphic, it has a efficiency and detail of graphic operation. To make and test animation data, it has the option of save and resume in animation.

  • PDF

Development of Man Machine I/F for Distributed Power Line Automation (배전선 자동운전을 위한 MMI System 개발사례)

  • Lee, J.D.;Kim, K.H.;Kim, K.R.;Ok, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.427-429
    • /
    • 1993
  • In this paper, GIS (Geographical Information System) for KODAS (Korea Distribution Automation System) will be presented. It has been developed to display the status of distribution power line facilities with background geographical map information (eg. address, street, railways and building) and provides various menu screen that can be handled easily. We will discuss computer system I/F between Host computer and GIS, DB structure for GIS and It's functions.

  • PDF

Development of Biped Walking Robot and Its Swing Motion (이족 보형로봇 개발과 그네 운동)

  • Park, Seong-Hoon;Kim, Jee-Hong;Yi, Soo-Yeong;Chong, Kil-To;Sung, Young-Whee
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2411-2413
    • /
    • 2003
  • A new small humanoid robot system is developed in this paper. The humanoid robot has total 20 DOFs : 6 DOFs in each legs, 3 DOFs in each arms, and 2 DOFs in head, 34cms in height, and 2kgs in weight. The robot has the following characteristics: (1) PDA as host controller (2) network-based joint controller (3) wireless camera attached in robot's head (4) mechanism design by CATIA and high speed laser prototyping (5) graphic MMI(Man-Machine Interface) utilizing the CATIA data. By using ADXL inclination sensor, we implement the rope swing with the robot leg motion as well as walking.

  • PDF

Application of a Domestic Boiler Distributed Control System to a Thermal Power Plant (국산개발 보일러 디지털 분산제어시스템의 화력발전소 실용화 최초적용)

  • Park, D.Y.;Byun, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2156-2159
    • /
    • 2001
  • 발전소 보일러 제어시스템 관련 기술은 분산처리 소프트웨어 기술, 네트워크기술, MMI(Man Machine Interface) 기술, 실시간 처리기술, 데이터베이스 기술, 하드웨어 개발기술 등을 총 망라하는 복합기술로써, 선진국들이 기술이전을 기피하는 고급기술이다. 현재 국내에서 사용하고 있는 발전소 보일러 제어시스템은 전부가 Bailey, ABB, Siemens, Westinghouse 사 등의 외국설비로써 보일러 본체와 일괄계약형태로 제어시스템 전체가 외국회사의 설계에 의해서 도입 설치되어 운용되고 있다. 이러한 상황에서 국산 제어시스템의 개발기술 확보와 기술자립 차원에서 오래된 아날로그 제어시스템을 디지털 분산제어시스템으로의 개체작업에 국산 개발 제어시스템을 중용량 석탄화력발전소에 최초로 실용화 적용하고 그 적용사례를 본 논문에서 소개한다.

  • PDF

Development of an Integrated Control and Monitoring System for Emergency Power Generators (비상발전기 통합제어 및 감시시스템 개발)

  • 진강규;류길수;윤지근;유성호;김재환
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.192-196
    • /
    • 2001
  • These days, most of electric power facilities need high stability. Therefore integrated system has been required to monitor and control electronic power distribution system in fields at all times when the interruption of electric power has occurred. To construct this system, unit that convert and process the input signal from fields needed. And for control and monitoring from remote place MMI software is required. Lastly network equipments are required for real-time communications. So, in this paper, units for control and monitoring of emergency power generator and for electric power monitoring in normal electric power and interruption of electric power are developed. Also integrated remote system for monitoring in remote is developed.

  • PDF