• Title/Summary/Keyword: MMAD

Search Result 15, Processing Time 0.021 seconds

Development of a nanoparticle multi-generator for assessment of inhalation hazard

  • Lee, Sung-Bae;Han, Jeong-Hee;Kim, Tae-Hyun;Cha, Hyo-Geun;Lim, Cheal-Hong
    • Analytical Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.87-98
    • /
    • 2021
  • In this study, we developed the nanoparticle multi-generator by 3D printer fusion deposition modeling (FDM) method that can reliably generate and deliver nanoparticles at a constant concentration for inhalation risk assessment. A white ABS filament was used as the test material, and SMPS was used for concentration analysis such as particle size and particle distribution. In the case of particle size, the particle size was divided by 100 nm or less and 100 to 1,000 nm, and the number of particles concentration, mass concentration, median diameter of particles, geometric average particle diameter, etc were measured. The occurrence conditions were the extruder temperature, the extruding speed of the nozzle, and the air flow rate, and experiments were conducted according to the change of conditions including the manufacturer's standard conditions. In addition, the utility of inhalation risk assessment was reviewed through a stability maintenance experiment for 6 h. As a result of the experiment, the size of the nanoparticles increased as the discharger temperature increased, as the discharge speed of the nozzle increased, and as the air flow rate decreased. Also, a constant pattern was shown according to the conditions. Even when particles were generated for a long time (6 h), the concentration was kept constant without significant deviation. The distribution of the particles was approximately 80 % for particles of 60 nm to 260 nm, 1.7 % for 1 ㎛ or larger, 0.908 mg/㎥ for the mass concentration, 111 nm for MMAD and 2.10 for GSD. Most of the ABS particles were circular with a size of less than 10 nm, and these circular particles were aggregated to form a cluster of grape with a size of several tens to several hundred nm.

Roadside Aerosols Size Distribution Characteristics in Jeju City (제주시 도로변에서의 에어로졸의 입경별 분포 특성)

  • Lee, Ki-Ho;Kim, Su-Mi;Hu, Chul-Goo
    • Journal of Environmental Science International
    • /
    • v.30 no.9
    • /
    • pp.727-739
    • /
    • 2021
  • Measurements on mass size distribution of roadside aerosols were obtained in downtown Jeju City from July 2018 to May 2020 using an 8-stage cascade impactor sampler and the compositions of aerosols were analyzed. The mass size distribution of total aerosols was bimodal with aerosols existing in both the fine and coarse modes. The mass size distributions of Na+, Mg2+, Ca2+, Cl-, NH4+ and SO42- were unimodal, whereas that of K+ was bimodal. For NO3-, the size distribution in winter and spring was bimodal with the peaks in both fine and coarse modes, whereas for summer and autumn the distribution was unimodal with a peak in the coarse mode. NH4+ was found to co-exist with SO42- in the fine mode with an average molar ratio of [NH4+]/[SO42-] equal to 2.05. Good correlation was observed between NO3- and NH4+ in the fine mode particles in spring and winter. Based on the value of the marine enrichment factor for Cl-, Mg2+, K+, Ca2+ and SO42-, it may be inferred that a major part of the roadside aerosols in downtown Jeju City was largely contributed by terrigenous sources, although the influence of sea salt was normally present.

Scar Formation of the Chronic ACL Rupture (만성 전방 십자 인대 파열의 반흔 형성)

  • Choi Eui-Seong;Won Choong-Hee;Kim Yong-Min;Seo Joong-Bae;Lee Ho-Seung;Lee Sin-Ro
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.1
    • /
    • pp.17-21
    • /
    • 2001
  • Purpose : To analyze changes of the anterior translation, MRI findings and associated injuries at scarring of the torn ACL in the chronic ACL rupture. Materials & Method : From Dec. 1996 to May 2000, 19 patients who were diagnosed as the chronic ACL rupture were studied. We analyzed KT-2000 side to side difference of maximal manual anterior displacement(MMAD), MRI findings and associated injuries. Results : There was statistically significant difference in the average MMAD between the 7 cases$(37\%)$ with scar formation$(2.78{\pm}2.41mm)$ and the 12 cases without scarring$(5.75{\pm}2.52mm)$. The chronic ACL rupture without scarring had more meniscal injuries$(67\%)$ than with scarring$(28\%)$. MRI showed that relatively straight bands toward expected insertion site with single large fragment(5 cases) and continuous band with focal angulation(2 cases). Conclusion : If relatively straight bands toward expected insertion site with single large fragment or continuous band with focal angulation on MR imaging is showed in the patient without significant anterior translation at arthrometer, the possibility of the scar formation of the torn ACL should be considered. We think that the chronic ACL rupture with scarring had less meniscal injuries than without scarring will give additional information on the natural history of ACL injuries.

  • PDF

Comparison of Area vs Personal Total Dust Concentrations Measured by 37mm Closed-face Cassette and IPM Sampler (목재분진 농도 측정에 대한 37 mm closed-face 카세트법과 IPM 측정법 비교)

  • Lee, Dong-won;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.67-76
    • /
    • 1996
  • This study was performed to estimate total dust concentrations and particle size distribution of wood dust in the furniture and sawmill industries. To compare total wood dust concentrations, two samplers recommended by the American Conference of Governmental Industrial Hygienists and by the National Institute for Occupational Safety and Health were used. Concentration data were analyzed by paired-t tests using the SAS program and two parameters of the particle size distributions were determined by histogram. The results were as follows: 1. Particle size distributions showed a unimodal pattern in cutting and a bimodal in sanding operations. Mass median aerodynamic diameters(MMAD) were $17.35{\mu}m$ in cutting, and $1.39{\mu}m$ for small mode and $18.89{\mu}m$ for large mode in sanding operations. The proportions of particle size larger than $9.8{\mu}m$ estimated by the impactor were 61.16 % in cutting and 62.33 % in sanding operations, respectively. 2. The average personal total dust concentrations measured by IPM sampler were $17.12mg/m^3$ (GSD=1.45) from indoor samples, $2.97mg/m^3$(GSD=1.90) from outdoor samples in cutting, and $8.01mg/m^3$(GSD=1.58) from sanding operation. And those of by 37 mm closed-face cassette were $9.12mg/m^3$(GSD=1.46), $1.06mg/m^3$(GSD=1.99) from cutting, and $3.32mg/m^3$(GSD=2.16) from sanding operations. 3. The average area total dust concentrations measured by IPM sampler were $1.88mg/m^3$(GSD=2.04) from indoor cutting, $4.76mg/m^3$(GSD=2.83) from indoor sanding operations. And those of by 37mm closed-face cassette were $0.49mg/m^3$(GSD=2.34) from cutting, and $1.32mg/m^3$(GSD=3.03) from sanding operations. 4. The ratio of personal total dust concentrations measured by 37 mm closed-face cassette to those by IPM sampler were 35.7 %, 53.3 % from cutting, and 41.4 % from sanding operations. 5. The ratio of area total dust concentrations measured by 37 mm closed-face cassette to those by IPM sampler were 26.1 % from cutting, and 27.7 % from sanding operations. 6. A statistically significant difference of total dust concentrations between the 37 mm closed-face cassette and the IPM sampler was found.

  • PDF

Performance Characteristics of PM10 and PM2.5 Samplers with an Advanced Chamber System (챔버 기술 개발을 통한 PM10과 PM2.5 시료채취기의 수행 특성)

  • Kim, Do-Hyeon;Kim, Seon-Hong;Kim, Ji-Hoon;Cho, Seung-Yeon;Park, Ju-Myon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.8
    • /
    • pp.739-746
    • /
    • 2010
  • The purposes of this study are 1) to develop an advanced chamber system within ${\pm}10%$ of air velocity at the particulate matter (PM) collection area, 2) to research theoretical characteristics of PM10 and PM2.5 samplers, 3) to assess the performance characteristics of PM10 and PM2.5 samplers through chamber experiments. The total six one-hour experiments were conducted using the cornstarch with an mass median aerodynamic diameter (MMAD) of $20\;{\mu}m$ and an geometric standard deviation of 2.0 at the two different air velocity conditions of 0.67 m/s and 2.15 m/s in the chamber. The aerosol samplers used in the present study are one APM PM10 and one PM2.5 samplers accordance with the US federal reference methods and specially designed three mini-volume aerosol samplers (two for PM10 and one for PM2.5). The overall results indicate that PM10 and PM2.5 mini-volume samplers need correction factors of 0.25 and 0.39 respectively when APM PM samplers considered as reference samplers and there is significant difference between two mini-volume aerosol samplers when a two-way analysis of variance is tested using the measured PM10 mass concentrations. The PM10 and PM2.5 samplers with the cutpoints and slopes (PM10: $10{\pm}0.5\;{\mu}m$ and $1.5{\pm}0.1$, PM2.5: $2.5{\pm}0.2\;{\mu}m$ and $1.3{\pm}0.03$) theoretically collect the ranges of 86~114% and 64~152% considering the cornstarch characteristics used in this research. Furthermore, the calculated mass concentrations of PM samplers are higher than the ideal mass concentrations when the airborne MMADs for the cornstarch used are smaller than the cutpoints of PM samplers and the PM samplers collected less PM in another case. The chamber experiment also showed that PM10 and PM2.5 samplers had the bigger collection ranges of 37~158% and 55~149% than the theocratical calculated mass concentration ranges and the relatively similar mass concentration ranges were measured at the air velocity of 2.15 m/s comparing with the 0.67 m/s.