• 제목/요약/키워드: MM system

검색결과 6,396건 처리시간 0.038초

새로 개발된 부상형 육묘에 있어서 스티로포움 판의 두께가 연초 묘 생육에 미치는 영향 (Influence of Thickness of Styrofoam-Panel on Tobacco Seedling Growth in Newly Developed Floating System)

  • 백기현;신승구;한종구;권구홍;김영신;이승철
    • 한국연초학회지
    • /
    • 제19권2호
    • /
    • pp.102-106
    • /
    • 1997
  • The inluence of styrofoam-panel thickness of floating frame on the seedling growth of flue-cured tobacco(Nicotiana tabacum L.) in the newly developed direct-seed float system was investigated . Floating frame used instead of styrofoam-tray consisted of styrofoam-panel (106×108cm) for floating, eight holes(1.Sx2S.0 cm) to uniform the water, and nutrition supply far seedling and water and nutrition absorption cloth placed on the styrofoam-panel. Each floating-frame may lay eight plastic-trays on it. Eight grades of styrofoam-panel thickness from 26 mm to 46mm and two kinds of media were used in the greenhouse system. Dry cells were found from the styrofoam-panel thickness of 43mm in carbonized chaff, compost and original soil rate of L3-3(v/v) media, and of 37mm in peat and perlite rate of 8-2(v/v) media. The thinner styrofoam-panel produced more tender and succulent seedling with the more trunk and the less root weight. When considering the appearance of dry cell, seedling growth, producing healthy tobacco seedlings, and utilization of styrofoam-panel for two kinds of medias the ideal styrofoam-panel thickness were suggested to be around 34mm for flue-cured tobacco reeling production in the newly developed direct-seeding float system. Key words : tobacco seedlings, float system, medium, styrofoam pannel, dry cell.

  • PDF

흡음장치를 내장한 고전압 퓨즈홀더의 최적설계에 관한 연구 (Optimum Design of High Voltage Fuse Holder with a Built-in Acoustic Absorber System)

  • 진영준;이해원;황유섭
    • 한국안전학회지
    • /
    • 제26권1호
    • /
    • pp.8-14
    • /
    • 2011
  • Noise and vibration are likely to disturb the sensory system of human body leading to psychological stress and thereby property damage. In this research, a cut out switch(COS) with a built-in acoustic absorber along with a COS fuse broken was developed to reduce percussion noise. This new system is based on a design approach that combines existing absorber systems: expansion type, resonator type, and acoustic absorber type silencer The noise performance of the new system was simulated using the $SYSNOISE^{TM}$ software under optimized parameters: the diameter of perforated plate 2 mm, the plate thickness 3 mm, the width of expansion room 25 mm, the impinging vortex room 14 mm, and the noise absorbtion room 10 mm. The results showed that it reduced noise by approximately 41.1 dB compared to the current systems available in the market. Furthermore, it showed reduced noise by approximately 12 dB more than a product with an acoustic absorber of the Fault Tamer(USA).

RPM SystemTM을 이용한 호흡 관찰의 유용성 평가 (The variability of tumor motion and respiration pattern in Stereotactic Body RadioTherapy(SBRT) for Lung cancer patients)

  • 박현준;배선명;백금문;강태영;서동린
    • 대한방사선치료학회지
    • /
    • 제28권1호
    • /
    • pp.17-25
    • /
    • 2016
  • 목 적 : 정위적체부방사선치료(Stereotactic Body Radiation Therapy, SBRT)를 시행하는 폐암환자의 호흡 변화에 따른 종양 움직임의 재현성을 비교 분석하고, 치료 중 환자 호흡의 안정도를 확인하여 호흡 신호 확인 과정의 유용성을 평가하고자 한다. 대상 및 방법 : 호흡연동방사선치료(Respiratory Gated Radiation Therapy, RGRT)를 실시한 30명과 RGRT를 시행하지 않는 30명을 그룹1, 2로 정하고, 4-Dimensional Computed Tomography (4-DCT), Cone-Beam CT (CBCT), 투시 영상에서 측정한 종양의 움직임 차이를 비교하였다. 그룹2를 대상으로 치료 중 호흡의 안정도를 확인하기 위해서 Real-time Position Management (RPM) System (version 1.7.5, Varian, USA)을 이용하여 호흡 신호의 기준 구간을 설정하고 치료 중 환자의 호흡이 정해진 구간에서 벗어난 횟수를 측정하였다. 결 과 : 4DCT에서 측정한 평균 움직임과 CBCT에서 평균 움직임의 차이가 그룹1은 전 후 방향, 축 방향, 측 방향 각각 1.0 mm, 1.1 mm, 1.9 mm, 그룹2는 0.3 mm, 0.9 mm, 0.4 mm로 확인되었다. 4DCT와 투시 영상의 축 방향에 대한 평균 움직임 차이는 그룹1에서 0.6 mm, 그룹2에서는 2.3 mm였고, CBCT와 투시 영상의 축 방향에 대한 차이는 그룹1에서 1.7 mm, 그룹2에서 1.4 mm의 차이를 보였다. 그룹2에서 1회 치료(15Gy)를 시행하는 동안 호흡 기준을 벗어나지 않고 치료가 시행된 경우는 대상 환자 30명의 총 120회 중 32회였고, 가장 많이 벗어난 환자는 1회 치료 시 최대 108번 설정 기준을 벗어난 것으로 확인되었다. 결 론 : 전체 대상 환자의 종양 움직임은 각각의 영상에서 평균적으로 5 mm 미만의 차이를 보였지만 특정 환자의 경우 13 mm이상의 차이가 있었고, RGRT를 적용하지 않은 환자들의 치료 중 호흡이 불안정한 것을 확인할 수 있었다. 본 연구를 통하여 고 선량이 전달되는 폐암 환자의 SBRT 시 RGRT를 적용하지 않는 환자에 대해서도 종양 움직임을 확인하고 RPM system 을 이용한 치료 중 호흡 관찰을 실시한다면, 치료 중 계획된 선량 전달의 정확성을 높일 수 있을 것으로 사료된다.

  • PDF

아베-코닉 프리즘을 이용한 스코프 개발 (Development of Scope with Abbe-König Prism)

  • 이동희;박승환
    • 한국안광학회지
    • /
    • 제18권4호
    • /
    • pp.509-517
    • /
    • 2013
  • 목적: 아베-코닉(Abbe-K$\ddot{o}$nig) 프리즘을 이용한 2.6X 광학식 스코프를 개발하고자 하였다. 방법: 먼저 대물렌즈의 초점거리와 유효구경의 크기를 고려하여 아베-코닉 프리즘을 설계하였다. 이렇게 설계되어진 아베-코닉 프리즘의 광학적, 기하학적 거리를 계산하였다. 이 계산 결과를 이용하여 전체 시스템의 광학적 유효거리 및 배율을 만족하도록 접안렌즈와 대물렌즈의 초점거리를 배분한 후 시스템을 최적화함으로서 전체 시스템을 완성하였다. 결과: Face length 11.5 mm를 가지는 아베-코닉 프리즘과 4매로 이루어진 초점거리 24.3 mm의 접안렌즈와 2매로 이루어진 초점거리 63.13 mm의 대물렌즈를 설계하여 약 2.6배율을 광학식 스코프를 완성할 수 있었다. 결론: 아베-코닉 프리즘을 채택한 2.6배율을 가지는 광학식 스코프를 설계 제작하였는데, $6.42^{\circ}$ 이내의 반 시야각에서 50% MTF 기준치로 200 cycles/rad의 분해능과 103 mm 유효 광학적 경통길이와 12.0 mm의 유효구경과 31 mm의 경통구경을 갖는 컴팩트한 광학계가 되었다.

후방 요추 극돌기간 유동적 오메가형 스프링 고정재의 역학적 평가 (Mechanical Evaluation of Posterior Dynamic Omega-wire Stabilization System)

  • 이연수;송근수
    • 대한기계학회논문집B
    • /
    • 제36권11호
    • /
    • pp.1099-1104
    • /
    • 2012
  • 본 연구에서는 새로운 후방요추간체의 고정재로서 뼈에 나사를 삽입고정하지 않고 후방요추간체에 걸어 시술하는 형상기억합금을 이용한 오메가형 스프링 유동적 고정재의 기계적 변형특성을 평가하였다. 사용된 오메가와형 스프링 고정재에 대해 인장, 압축, 동적피로시험을 실시하였다. 또한, 기존에 시판 중인 후방요추간체에 나사를 삽입하여 시술되는 나선형 스프링 유동적 고정재와 함께 유한요소방법을 이용하여 허리를 굽힐 때 가해지는 굽힘에 대한 변형해석을 실시하였다. 오메가형 스프링 고정재의 양단 고리중심간 거리가 60 mm인 시편의 평균 극한 인장하중은 3981.7 N, 평균 극한 압축하중은 535.6 N으로 나타났으며, 5 Hz의 반복주기로 10 N/1N의 압축피로하중을 가할 경우 5백만회 반복하는 동안 파단 없이 8~9 mm의 압축변위가 발생하였다. FEA 결과에서 보면 오메가형 스프링 고정재가 나선형 스프링 고정재보다 허리 굽힘에 대해 유연한 변형특성을 보였다.

전부도재관의 변연 적합도 비교평가 (Comparative study in marginal accuracy of several all ceramic crowns)

  • 김정미;정수하
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.87-92
    • /
    • 2008
  • Purpose: In this study, we tried to compare marginal accuracy when produce ceramic crown using all ceramic materials and existent metal-ceramic system. Material and methods: All-ceramic systems were E-max (Ivoclar/Vivadent, Lichtenstein), Lava(3M, U.S.A.) and Wol-ceram(Teamziereis, Germany). Metal-ceramic system(PFG) was composed of Au-Pt alloy (Metalor, Switzerlandand) and overlying ceramic(D-sign, Ivoclar/Vivadent, Lichtenstein). We fabricated metal master die with upper diameter of 7.95mm, bottom diameter of 9.00mm, height of 5.00mm, and taper of $6^{\circ}$. All ceramic system used 0.5mm thickness ceramic coping, while metalceramic system used 0.3 thickness metal coping. By adding dentin and enamel ceramics on each coping, a crown with a proximal thickness of 1.0 mm and occlusal thickness of 2.0mm was fabricated. Pressure of 2kg was applied for 10 seconds on each crown with static load compressor. Before and after cementation, we measured the marginal gap at 4 points of each crown using optical microscope. The data was analyzed using a Student's t test and repeated-measures of analyses of variance(ANOVA) followed by a Bonferroni test. A p value<0.05 was considered significant. Results: As experiment results, marginal accuracy of wol-ceram and Lava is no good when compared with marginal accuracy of PFG. But marginal accuracy of E.max is good when compared with PFG. This result showed not significant. The marginal accuracy of E.max is good when compared with marginal accuracy of wol-ceram and Lava. Conclusion: The marginal accuracy of E.max is very good when compared with marginal accuracy of another group.

  • PDF

실시간 위험환경 관리를 위한 센서 모듈시스템 연구 (A Study on the Sensor Module System for Real-Time Risk Environment Management)

  • 조영창;권기진;정종혁;김민수
    • 전기전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.953-958
    • /
    • 2018
  • 본 연구에서는 산업현장, 지하시설물의 밀폐공간에서 유해가스 및 생체신호를 동시에 검출이 가능한 휴대형 검출시스템을 개발하였다. 개발된 시스템은 가스검출용 센서모듈, 패치형 1채널 소형 ECG 센서, 3축가속도 검출센서용 모듈 및 통계분석용 시스템이다. 시스템모듈의 성능을 검증하기 위해 디지털해상도, 생체신호증폭도, 출력전압 및 초소형모듈의 크기로 평가하였다. 개발된 시스템의 성능결과 디지털해상도는 300(rps), 신호증폭이득은 500dB이상 성능을 가졌고, 심전도 모듈은 $50mm{\times}10mm{\times}10mm$로 제작되어 패치형으로 활용도를 높일 수 있다. 본 연구의 휴대용 가스검출기 및 패치용 심전도, 가속도검출기는 산업현장작업자의 실시간 감시용 IoT 기반 관리시스템으로 활용한다면 가치가 높을 것으로 생각된다.

예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석 (An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration)

  • 서정민;이창열;허현도;김완선
    • 대한방사선치료학회지
    • /
    • 제27권2호
    • /
    • pp.157-166
    • /
    • 2015
  • 목 적 : 사이버나이프 종양 추적 시스템(Cyber-knife tumor tracking system)은 환자 외부에 부착한 LED marker에서 얻어진 실시간 호흡 주기 신호와 호흡에 따라 움직이는 종양의 위치와의 상관관계를 바탕으로 종양의 위치를 미리 예측하고 종양의 움직임을 치료기와 동기화 (Synchronize) 시켜 실시간으로 종양을 추적하며 치료하는 시스템이다. 본 연구의 목적은 사이버나이프 종양 추적 방사선 치료 중 기침이나 수면 등으로 인해 예측 불가능한 갑작스러운 호흡 형태 변화에 따른 종양 추적 방사선 치료 시스템의 정확도를 평가하고자 한다. 대상 및 방법 : 연구에 사용된 호흡 Log 파일은 본원에서 호흡 동조 방사선치료(Respiratory gating radiotherapy)나 사이버나이프 호흡 추적 방사선수술(Cyber-knife tracking radiosurgery)을 받았던 환자의 호흡 Log 파일을 바탕으로, 정현곡선 형태(Sinusoidal pattern)와 갑작스런 변화 형태(Sudden change pattern)의 Log 파일을 이용하여 측정이 가능하도록 재구성하였다. 재구성 된 호흡 Log 파일을 사이버나이프 동적 흉부 팬텀에 입력하여 호흡에 따른 움직임을 구현할 수 있도록 기존 동적 흉부 팬텀의 구동장치를 추가 제작하였고, 호흡의 형태를 팬텀에 적용 시킬 수 있는 프로그램을 개발하였다. 팬텀 내부 표적(Ball cube target)의 움직임은 호흡의 크기에 따라 상하(Superior-Inferior)방향으로 5 mm, 10 mm, 20 mm 3가지 크기의 변위로 구동하게 하였다. 팬텀 내부 표적에 EBT3 필름 2장을 교차 삽입하여 표적 움직임의 변화에 따라 사이버나이프 제조사에서 제공된 End-to-End(E2E) test를 호흡의 형태에 따라 각각 5회씩 실시하고 측정하였다. 종양 추적 시스템의 정확도는 삽입된 필름을 분석하여 표적 오차(Targeting error)로 나타내었고, 추가로 E2E test가 진행되는 동안 상관관계 오차(Correlation error)를 측정하여 분석하였다. 결 과 : 표적 오차는 정현곡선 호흡 형태일 경우 표적 움직임의 크기가 5 mm, 10 mm, 20 mm 에 따라 각각 평균 $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, $2.37{\pm}0.17mm$이고, 갑작스런 호흡 변화 형태일 경우 각각 평균 $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, $2.44{\pm}0.26mm$으로 분석되었다. 표적 추적에 있어 변위 벡터의 길이로 정의할 수 있는 상관관계 오차는 정현곡선 호흡 형태일 경우 표적 움직임의 크기가 5 mm, 10 mm, 20 mm 에 따라 각각 평균 $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, $1.63{\pm}0.10mm$이고, 갑작스런 호흡 변화 형태일 경우 각각 평균 $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, $1.98{\pm}0.10mm$으로 분석되었다. 두 호흡 형태에서 모두 상관관계 오차 값이 클수록 표적 오차 값이 크게 나타났다. 정현곡선 호흡 형태의 표적 움직임 크기가 20 mm 이상일 경우, 두 오차 값 모두 사이버나이프 제조사의 권고치인 1.5 mm 이상으로 측정되었다. 결 론 : 표적 움직임의 크기가 클수록 표적 오차 값과 상관관계 오차 값이 증가하는 경향이 있었으며, 정현곡선 호흡 형태보다 갑작스런 호흡 변화 형태에서 오차 값이 크게 나타났다. 호흡의 형태가 규칙적인 정현 곡선 형태더라도 표적의 움직임이 클수록 종양 추적 시스템의 정확도가 감소하는 것으로 판단할 수 있다. 사이버나이프 종양 추적 시스템의 알고리즘을 이용하여 치료 시행 시 환자의 기침 등으로 인하여 갑작스럽게 예측 불가능한 호흡 변화가 있는 경우 치료를 멈추고 내부 표적 확인 과정을 재실시 하여야 하며 호흡 형태를 재조정해야 할 필요가 있다. 치료 중 환자가 본인의 호흡 형태를 관찰 할 수 있는 고글 모니터 등을 착용하여 규칙적인 호흡 형태를 유도하는 것이 치료의 정확도는 향상될 수 있다고 판단된다.

  • PDF

저주파대 음향 현미경의 구성과 그 응용에 관한 연구 (A Study on the construction of Low-Frequency Acoustic Microscope and Its Application)

  • 고대식;문건;전계석;황금찬
    • 대한전자공학회논문지
    • /
    • 제25권5호
    • /
    • pp.580-585
    • /
    • 1988
  • In this paper, a low frequency acoustic microscope system has been built for the purpose of detecting subsurface defects in materials. The lateral resolution of acoustic microscope is studied and analyzed in order to evaluate that system performance. And a NDE technique is demonstrated by using this system. In the focused and defocused mode of operation, the acoustic microscope system showed in experiment that its lateral resolution was about 0.5 mm at a frequency of operation of 3MHz on a fused-quartz sample with seeded circular cracks ranged in size from 0.2 mm to 1.0 mm in diameter wihtin 1 mm of the surface. It also showed the acoustic image of 100 won coin with fine contrast.

  • PDF

잠열축열시스템의 축열과정에서 자연대류의 영향에 관한 연구 (Effect of Natural Convection on the Heat Transfer in a Latent Heat Storage System)

  • 유승남;한귀영
    • 태양에너지
    • /
    • 제19권2호
    • /
    • pp.29-36
    • /
    • 1999
  • Heat transfer characteristics of a low temperature latent heat storage system during the heat storage stage was examined for the circular finned tubes using fatty acid which shows the big density difference during melting as phase change materials. The heat storage vessel has the dimension of 530 mm height, 74 mm inside diameter and inner heat transfer tube is 480 mm in height and 13.5 mm outside diameter. Hot water was employed as the heat transfer fluid. During the heat storage stage, it was found that both conduction and natural convection were the major heat transfer mechanism. It was also found that the effect of natural convection on the heat transfer was more significant for the unfinned tube system than that for the finned tube system. The experimentally determined overall heat transfer coefficients were in the range of $50{\sim}250W/m^2K$ and the correlation for natural convection heat transfer as a function of Nusselt and Rayleigh number was proposed.

  • PDF