• 제목/요약/키워드: MM system

검색결과 6,374건 처리시간 0.035초

발계측 자료에 기초한 신골 할출 시스템의 검증에 관한 연구 (A Study on Verification of Shoe Last Grading System Based on Foot Measuring Data)

  • 박해수
    • 대한인간공학회지
    • /
    • 제26권1호
    • /
    • pp.71-77
    • /
    • 2007
  • Shoe's size and shape are determined by the last that takes shape of foot because last is the mold of shoe in development and manufacturing process. Then adaptation between foot and shoe is dependent on the last. In mass shoe production, model size is developed in the first place, other sized lasts are made through the grading process based on model size. The most important factor in grading system is grading deviation that must be same amount induced from foot measuring database. At present, most of the last manufacturing companies in korea using 260mm as a standard foot model size. When length grading deviation is 5mm, the ball girth grading deviation is 3.7mm and the ball width grading deviation is 1.2mm. I verified existing grading system by comparing grading results with foot measuring data. Also, I proposed reasonable grading deviation and application method of grading system. From the analysis of foot measuring database, reasonable grading deviations are 1.22mm in ball width and 0.84mm in ankle height in case of length grading deviation is 5mm. I confirmed that the current grading system is very accurate. When we grade last from 230mm to 290mm by current grading system based on model size 260mm, there is grading error over 1mm in the front outside area of foot. This error level of 1mm is no problem in normal walking shoe's last, but it induces adaptation problems in sports and special purposed shoe's last. Therefore using of three standard model size is recommended in grading men's last for reducing grading deviation error under the level of 1mm. It is specifically described as 235mm in 225-245mm, 260mm in 250-270mm, 285mm in 275-295mm. According to the above recommended grading system, it is enough to measure only three foot sizes in case of foot measuring project for men's last development.

Micro lens array 설계 (Design of micro lens array)

  • 홍경희
    • 한국광학회지
    • /
    • 제5권2호
    • /
    • pp.204-211
    • /
    • 1994
  • 팩시밀이나 복사기용으로 이용되는 micro lens array를 설계하였다. array 형태는 육각형배열이고 유효경은 0.160mm, 가장 가까운 이웃렌즈의 중심간 거리는 0.192mm로 하였다. 결상계의 횡배율은 1.0이다. single layer는 working distance가 10.55mm, double layer는 working distance가 7.90mm가 되었다. 각각의 성능은 ray fan을 계산하여 그 특성을 조사하였으며 서로 비교하였다.

  • PDF

홍채 촬영용 광학계 설계 (Design of an Optical System for Iris Photographing)

  • 박승환;이동희
    • 한국안광학회지
    • /
    • 제14권4호
    • /
    • pp.39-44
    • /
    • 2009
  • 목적: 홍채학에 사용되는 소형 홍채 촬영용 광학계 설계. 방법: 소형 홍채 촬영용 광학계를 설계하기 위해 Sigma 2000 광학 설계 프로그램을 사용하였다. 결과: 마이크로 액츄에이터를 오토 포커싱에 사용하는 CCD에 적합한 홍채 촬영용 광학계를 설계하였는데, TCL이 30 mm이고, 배율이 -0.65배, 첫 번째 렌즈에서 마지막 렌즈까지의 거리가 약 8.0 mm, 경통 최대 구경 11 mm, 스톱의 유효구경이 약 1 mm인 특성을 가지는 광학계가 되었다. 또한 분해선폭은 30% MTF 값 기준으로 92 lps/mm인 특성을 보여준다. 결론: TCL이 30 mm이고, 첫 번째 렌즈에서 마지막 렌즈 까지의 거리가 약 8.0 mm, 경통 최대 구경 11 mm이고, MTF 30% 기준에서 분해능 선폭이 $5.4{\mu}m$에 이르는 광학계를 설계하여 홍채 촬영용 광학계를 소형화 할 수 있었다.

  • PDF

홍채인식용 광학계 설계 (Optical system design for recognition of human iris)

  • 홍경희
    • 한국광학회지
    • /
    • 제11권6호
    • /
    • pp.390-394
    • /
    • 2000
  • 사람의 홍채 인식을 통항 보안 통제를 하기 위한 광학계를 설계하였다. 이 렌즈는 종색수차와 Petzval sum을 최소로 하는 triplet형이다. 초점거리를 50mm 유효경을 10mm로 하였고 물체로부터 상까지의 거리는 200mm-300mm로 고려하였다. 눈을 고려한 전체 광학계의 성능은 ray-fan과 spot diagram 그리고 회절광학적인 MTF를 계산하여 평가하였다. 홍채의 크기를 고려하여 물체 높이 0mm, 4mm 그리고 6mm 에 대하여, 파장은 Fraunhofer C, d 및 F-line에 대하여 모두 계산한 결과 spot 크기는 0.05mm 직경을 벗어나지 않았고 MTF 값도 물체 높이 6mm에 대한 486mm 파장의 sagittal MTF를 제외하고는 20 lines/mm의 공간주파수에서 0.5이상이 되었다.

  • PDF

방사선치료 시 C-Rad system을 이용한 셋업의 평가 (Evaluation of Setup When Using C-Rad System in Radiotherapy)

  • 박은태;고성진;최석윤;김정훈;김창수;김동현;강세식
    • 한국콘텐츠학회논문지
    • /
    • 제12권5호
    • /
    • pp.303-310
    • /
    • 2012
  • 방사선 치료에 있어서 정확한 환자 포지셔닝과 셋업은 치료의 성패를 좌우할 수 있는 중요한 인자이다. 기존의 방사선 치료실내에 장착된 3-laser system을 이용한 셋업에서, 최근에는 체표면 윤곽 스캐닝 시스템(C-Rad system)의 사용이 시도되고 있다. 체표면 윤곽 스캐닝 시스템의 유용성을 평가하기 위하여 C-Rad system과 3-laser system을 이용한 셋업 오차의 정확도를 비교, 평가함으로써 임상에서의 유용성을 확인하고자 하였다. 인체부위는 내부적인 움직임이 없고, 고정용구의 적용이 간편한 두경부로 한정하였으며, Alderson Rando anthropomorphic phantom과 두경부에 병변이 있는 방사선 치료 환자 10명을 대상으로 하였다. Phantom을 대상으로 한 C-RAD system의 셋업 에러 평균과 표준편차는 X축 $0.55{\pm}0.51mm$, Y축 $-0.2{\pm}0.523mm$, Z축 $-0.85{\pm}0.587mm$로 나타났으며, 환자를 대상으로 한 실험에서는 X축 $-0.05{\pm}0.621mm$, Y축 $0.075{\pm}0.755mm$, Z축 $-1.025{\pm}0.617mm$로 산출되어, 전반적으로 3-laser system에 비해 셋업의 정확도가 우수하였으나, Z축의 에러 발생률은 C-RAD system이 약간 높게 나타났다. 체표면 윤곽 스캐닝 시스템은 두경부의 방사선 치료 시에 정확한 포지셔닝을 유도함으로써 셋업오차를 최소화 시키는데 기여할 것으로 사료된다.F

로봇 착유시스템을 위한 다관절 매니퓰레이터 개발 (Development of a Multi-joint Robot Manipulator for Robot Milking System)

  • 김웅;이대원
    • Journal of Biosystems Engineering
    • /
    • 제30권5호
    • /
    • pp.293-298
    • /
    • 2005
  • The purpose of this study was the development of a multi-joint robot manipulator for milking robot system. The multi-joint robot manipulator was controlled by 5 drivers with driver controller through the position information obtained from the image processing system. The robot manipulator to automatically attach each teat cup to the teats of a milking cow was developed and it's motion was accurately measured with error rate. Results were as follows. 1. Maximum errors in position accuracy were 4mm along X-axis, 4.5mm along Y-axis and 0.9mm along Z-axis. Absolute distance errors were maximum 4.8mm, minimum 2.7mm, and average 3.6mm. 2. Errors of repeatability were maximum 3.0mm along X-axis, 3.0mm along Y-axis, and 0.5mm along Z-axis. Distance error values were maximum 3.2mm, minimum 2.2mm, and average 2.5mm. It is envisaged that multi-joint robot manipulator can be applicate to milking robot system being developed in consideration of the experiment results.

단분절 척추경 나사못의 피로수명과 Pre-Load의 영향 (The effect of pre-load and fatigue life for one-level pedicle screw system)

  • 김병일;이효재;송정일
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1298-1301
    • /
    • 2003
  • The purpose of this research is to evaluate the effect of pre-load and fatigue life of the distracted one-level pedicle screw system. A spring, which acted as a substitute of the ligament, was installed in the one-level pedicle screw system before testing. The static and fatigue properties are now being tested, which includes 6mm rod to 6mm screw, 6mm rod to 6.5mm screw and 6.35mm rod to 6.5mm screw, under pre-load. Until now as test data were analyzed, 6mm rod to 6.5mm screw was found to have the best performances of stillness and fatigue lift, while 6mm rod to 6mm screw showed the shortest fatigue life. If the stiffness of screw was bigger than that of rod. the fatigue life was prolonged. The fatigue life of the distracted pedicle screw was proved to be shorter than that of the one-level pedicle screw system. So the fatigue life was shortened because of the effect of the spring on the flexibility and stiffness of the rod. In order to obtain the stability of the pedicle screw, more tests are under doing on this topic.

  • PDF

디지탈 화상처리를 이용한 사출제품의 길이측정용 시각검사시스템 개발에 관한 연구

  • 김재열;박환규;오보석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.281-285
    • /
    • 1996
  • In this paper, I made visual inspection system using Vision Board and it is consist of an illuminator (a fluorescent lamp), image input device(CCD(Charge)Coupled Device) camera), image processing system(Vision Board(FARAMVB-02), image output device(videomonitor, printer), a measuring instrument(TELMN1000). Length measurement by visual inspection system is used 100mm gauge block instead of calculating distance between camera and object, it measured horizontal and vertical length factor from 400mm to 650mm by increasing 50mm. In this place, measured horizontal and vertical length factor made use of length measurement of a injection. A measuring instrument used to compare a measured length of a injection visual inspection system with it. In conclusion, length measurement of a injection compared a measuring instrument withvisual inspecion system using length factor of 100mm guage block. Maximum error of length compared two devices a measuring instrument with visual inspection system is 0.55mm. And operation program is made up Borland C++ 3.1. By changing, it is applied to various uses.

  • PDF

메타구조 기반의 고효율 공진형 무선전력전송 시스템 (Resonant Wireless Power Transfer System with High Efficiency using Metamaterial Cover)

  • 김형준;서철헌
    • 전자공학회논문지
    • /
    • 제51권1호
    • /
    • pp.47-51
    • /
    • 2014
  • 본 논문에서는 공진형 무선전력전송 시스템의 효율 개선을 위해 메타구조 기반의 단위 셀 및 배열 된 구조를 제안하였다. 자기장 집속을 위해 제로 굴절률 특성을 이용하였으며, 이를 구현하기 위해 유효 투자율의 실수가 0의 값을 갖도록 설계하였다. 제안된 단위 셀의 크기는 $70mm{\times}70mm{\times}3.2mm$이며, 동작 주파수는 13.56 MHz 이다. 또한, 배열된 구조의 크기는 $400mm{\times}400mm{\times}3.2mm$이며, 2-layer 구조로 이루어져 있다. 본 논문에서 제안한 공진형 무선전력전송 시스템의 효율은 송수신 공진기 사이의 거리가 100 mm ~ 400 mm에서 각각 94.8 %, 93.2 %, 91.4 %, 90.8 % 이며, 전체 거리에서 90 % 이상의 고효율 특성을 얻을 수 있었다.

영상처리를 이용한 작물의 모종시기 결정 (Determination of Transferring Period of Several Plants using Image Processing)

  • 민병로;김웅;김동우;이대원
    • 생물환경조절학회지
    • /
    • 제13권3호
    • /
    • pp.178-184
    • /
    • 2004
  • 본 연구는 영상 처리를 이용하여 채소의 모종 시기를 자동으로 파악할 수 있는 시스템을 개발하기 위한 것이다 즉 작물의 높이, 장변 및 단변을 영상처리를 이용해 자동으로 측정하고자 하는 시스템을 개발하고자 한 것이다. 각 작물 당 20개씩의 실험체를 두어반복 측정한 결과, 들깨의 경우 높이는 평균 오차 5.0mm로 평균 실측 길이 대비 1.7% 오차율, 장변은 평균 오차 4.7mm, 오차율 3.9%, 단변은 평균 오차 5.5 mm, 오차율 6.9%로 나타났다. 도라지의 경우 높이는 평균 오차 2.4 mm, 오차율 8.1%, 장변은 평균 오차 3.4 mm, 오차율 7.2%, 단변은 평균 오차 4.0 mm, 오차율 10.4%로 나타났다. 상추의 높이는 평균 오차 4.0 mm, 오차율 9.1%, 장변은 평균 오차 3.4 mm, 오차율 7.2%, 단변은 평균 오차 3.6mm, 오차율 9.4%로 나타났다. 따라서 현장 환경에 맞게 좀 더 개선된다면 사람의 시각을 이용한 작물의 생장상태 판별보다 더 정확하다고 판단된다.