• Title/Summary/Keyword: MLSS

Search Result 219, Processing Time 0.027 seconds

Effect of electrode coating and applied voltage of pulsed electric fields (PEF) on sludge solubilization (펄스전기장 (Pulsed Electric Fields)의 전극 코팅과 인가 전압에 따른 슬러지의 가용화 효과)

  • Um, Se-Eun;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.16-23
    • /
    • 2018
  • Alternative technologies for sludge treatment and disposal need to be developed urgently because the amount of produced production has increased continuously. In this study, Pulsed Electric Fields (PEF) technique was applied for sludge solubilization and the performance was evaluated. The PEF equipped with electrodes coated by epoxy resin and teflon was inducted to the activated sludge suspension, and the effect of the coating materials on the solubilization was determined. In addition, the effect of the applied voltage on the solubilization yield was investigated as the applied voltage was increased from 6 to 12 and 15 kV. Sludge solubilization was not observed when the epoxy-coated electrode was used for PEF induction regardless of the applied voltage. However, sludge solubilization occurred when 12 and 15 kV were applied to the teflon-coated electrodes. The MLSS decreased to 9%, and the soluble-COD increased to 496% when the applied voltage was 15 kV. But sludge solubilization did not happen under 6 kV condition. The corona discharge was observed at applied voltages of 12 and 15 kV, (Ed- sorry but I cannot understand the following highlight) but if 6 kV, strongly indicating that the corona discharge make the sludge solubilized, which suggests that the critical voltage for sludge solubilization lies between 6 and 12 kV. Consequently, proper selection of electrode-coating materials and the applied voltage of PEF could lead to sludge solubilization by corona discharge.

Treatment Characteristics Using Full-Scale SBR System (Full-Scale SBR 공법을 이용한 처리특성)

  • Choo, Tai-Ho;Lee, Yong-Doo;Cho, Yong-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.10
    • /
    • pp.34-40
    • /
    • 2006
  • In this study, the treatment of organic matters and nutrients like Nitrogen and Phosphorus with sequencing batch reactors (SBR) was conducted. The following conclusions can be summarized from the study. The influent BOD concentration was varied 19.6 to 40.0mg/L and the effluent was 3.0 to 14.8mg/L. The variations of BOD removal efficiency during the experimental period was $47.9{\sim}88.4%$ and the average was 80.8%. The average removal efficiency was stabilized with the passage of time. Also the COD concentration was flowed into as $12.2{\sim}32.0mg/L$ and the effluent concentration was varied 3.3 to 18.6 mg/L, and then the average COD removal efficiency was 57.3%(minimun 19.2% and maximum 78.6%). But fortunately, the COD removal efficiency was also stabilized as 70.2% after 79days. In the case of T-N, the influent concentration range was $7.53{\sim}14.99mg/L$ and the effluent concentration was 6.59mg/L(the average removal efficiency was 40.3%) until the first experiment time 79days. But after normalizing the system, it was 4.44mg/L (the average removal efficiency was 56.4%). Also the influent T-P concentration was varied from 0.77 to 1.91mg/L and the effluent concentration was $0.26{\sim}1.53mg/L$. The removal efficiency was varied from 5.3 to 71.7%. considerably, therefore the average removal efficiency was 42.6%. The reason was concluded that the sludge wasn't discharged for increasing MLSS concentration.

  • PDF

Long Term Operation of Biological Hydrogen Production in Anaerobic Sequencing Batch Reactor (ASBR) (생물학적 수소생산을 위한 혐기성 연속 회분식 반응조(ASBR)의 장기운전 특성)

  • Jeong, Seong-Jin;Seo, Gyu-Tae;Lee, Taek-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Long term hydrogen production was investigated in an anaerobic sequencing batch reactor (ASBR) using mixed microflora. Glucose (about 8,250 mg/L) was used as a substrate for the ASBR operation under the condition of pH 5.5 and $37^{\circ}C$ with mixing at 150 rpm. The experiment was carried out over a period of 160 days. Hydrogen yield was 0.8mol $H_2/mol$ glucose with F/M ratio 2 at initial operation period. The hydrogen yield reached to maximum 2.6 mol $H_2/mol$ glucose at 80th day operation. However decreased hydrogen yield was observed after 80 days operation and eventually no hydrogen yield. Although well-known hydrogen producer Clostridium sp. was detected in the reactor by PCR-DGGE analysis, changed reactor operation was the major reason of the decreased hydrogen production, such as low F/M ratio of 0.5 and high propionic acid concentration 2,130 mg/L. Consequently the long period operation resulted in MLSS accumulation and then low F/M ration stimulating propionic acid formation which consumes hydrogen produced in the reactor.

Study on Removal Efficiency of Complex Wastewater from Agricultural and Industrial Plant for Advanced Treatments (고도처리를 위한 농공단지 복합폐수의 처리효율 특성에 관한 연구)

  • Seo, Tae Won;Kim, Moon Suk;Park, Young Dal;Cho, Wook Sang
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.2
    • /
    • pp.53-65
    • /
    • 2012
  • This study was focused on removal efficiency of complex (or mixed) wastewater from agricultural and industrial plant for advanced treatments by HBR-II process, that was well known to be suitable to the treatment of livestock wastewater. The main purpose of this study was intended to evaluate the applicable feasibility of the HBR-II for revamping the present activated sludge process to the advanced one. And also, the settling study including the batch typed experimental column tests was performed to evaluate the coagulation stability of organic colloidal particles in wastewater. The mid-scale plant of HBR-II process between pilot and laboratory was used for this study. As F/M ratio remains constant in the range of 0.20~0.25 $BOD_5/Kg{\cdot}MLSS/Day$, the efficiency of biological treatment increased. It has been shown that the results of biodegradation study were, for removal efficiency(%), $BOD_5$ 98.4%, $COD_{Mn}$ 92.9%, SS 97.5%, T-N 91.3%, T-P 82.3%, respectively, which were relatively higher than other processes. From this study, HBR-II process would be well applied to the biological treatment of agricultural and industrial complex wastewater.

Preparation of PVdF/GO Composite Nanofibrous Flat Membrane and its Permeation Characteristics in Activated Sludge (PVdF/GO 복합 나노섬유 평막의 제조 및 활성슬러지 내 투과특성)

  • Won, In Hye;Jang, Wongi;Chung, Kun Yong;Byun, Hongsik
    • Membrane Journal
    • /
    • v.25 no.1
    • /
    • pp.67-74
    • /
    • 2015
  • In this study the nanofiber was prepared by electrospinning method with polyvinylidene fluoride (PVdF) and a completely dispersed solution of graphene oxide (GO) in the mixed solvent of dimethylformamide (DMF) and acetone. The $0.4{\mu}m$ pore size microfiltration flat membrane was made by increasing layers of the PVdF/GO composite nanofiber. Also, transmembrane pressure (TMP) was measured in order to evaluate fouling of the PVdF/GO composite membrane which was introduced GO reducing biological fouling with the intrinsic antibacterial characteristics. The permeate experiments were carried out simultaneously for the PVdF/GO and commercialized CPVC (chlorinated polyvinyl chloride) flat membranes with $0.01m^2$ effective area in the activated sludge solution of MLSS 4,500 mg/L. TMP of PVdF/GO membrane decreased up to 79% lower than that of CPVC for $10L/m^2{\cdot}h$ permeate flux without air supply. Also, for the case of run/stop operational mode, TMP of PVdF/GO membrane decreased up to 69% lower than that of CPVC for $10L/m^2{\cdot}h$.

Design Parameters of Sequencing Batch Reactor treating ship sewage (연속 회분식 공정(SBR)을 이용한 선박 오 ${\cdot}$ 폐수처리 설계인자 도출)

  • Park, Sang-Ho;Kim, In-Soo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.29 no.1
    • /
    • pp.293-298
    • /
    • 2005
  • Lab scale experimental study was carried out for SBR process, to investigate the effects of influent ship sewage organic compound removal and Bacillus sp. state on design parameters. This process was able to remove nitrogen and phosphorus as well as organic matter efficiently. More than 95% of chemical oxygen demand(COD) were removed. In addition, about 97% of total nitrogen (T-N) was reduced. The total phosphorus(T-P) reduction averaged 93%. The performance load of SBR process was shown to be 0.095kg ${\cdot}$ TOC/$m^{3}$ ${\cdot}$ day. The pH was decreased from 8.1 to 7.0 within 30 min and increased to 7.3 at the end of anoxic stage, and these phenomena were explained. The sluge produced in the SBR process is characterized by low generation rate (about 0.36kg ${\cdot}$ MLSS/kg ${\cdot}$ TOC) and excellent settleability. The number of Bacillus sp. in the SBR was 24.2%, indicating that Bacillus sp. was a predominant species in the reactor.

  • PDF

The Effect of the Attached Growth in Aerobic Reactor on Nitrogen Removal in A2/O processes (포기조에 충진된 고정상 담체가 A2/O공정에서 질소제거에 미치는 영향)

  • Whang, Gye-Dae;Bae, Sung-Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1022-1030
    • /
    • 2006
  • Activated sludge reactors maintaining an MLSS of 3,000 mg/L and packed Bio Contact Media (BCM fixed beds) was studied in lab-scale to determine the optimal packing ratio and an HRT of aerobic reactor in terms of organic removal, nitrification, denitrification efficiencies. At all HRTs of 3 hr, 5 hr, 7 hr respectively, reactors without BCM, control reactors, had the lowest TCODcr removal efficiency about 74.6%, and reactors with the BCM packing ratios of 10%, 15%, 20% had a greater TCODcr removal efficiency above 81.4%. As HRT decreased, the TCODcr removal efficiency decreased also in all reactors. However, a better utilization of TCODcr even at a higher organic loading was observed in reactors with BCM. The nitrification efficiency at all reactors was greater than 94%, and reactor with 20% packing of BCM had the highest nitrification efficiency at 97.9% while the TKN loading increased at $0.085mgTKN/m^3{\ast}day$ as HRT decreased, In terms of denitrification efficiency, the reactor without BCM ranged from 11.6% to 13.7%, and the reactors with BCM ranged from 28.3% to 63.4% which suggests that the more BCM is packed in the reactors, the higher the denitrification efficiency is achieved. Two parallel $A^2/O$ systems maintaining an MLSS of 3,000 mg/L were operated to investigate the effect of BCM packing ratio of 20% on organic removal, nitrification, denitrification efficiencies. Packing with BCM in system of aerobic reactor affected the SCODcr removal efficiency that increased from 73% to 78%. The nitrification efficiency for both systems with or without BCM was greater than 95%. The denitrification efficiency of systems with BCM and without BCM was 85.8% and 81.8%, respectively which appears that the denitrification efficiency was increased slightly by packing BCM. Compared denitrification efficiency in $A^2/O$ system to previous experimental study with activated sludge reactors operates with the same HRT $A^2/O$ system showed only 29% greater denitrification efficiency. It suggests that $A^2/O$ system with BCM can achieve a similar level of denitrification efficiency when the HRT of anoxic reactor is decreased to some extent.

Effects of Membrane Filtration Concentrate of Sewage Reuse Facility on Performance of Bioreactor in Sewage Treatment Facility (하수재이용시설 농축수가 하수처리장 생물반응조 운영에 미치는 영향)

  • Lim, Ji-Young;Kim, Hyun-Sik;Bae, Min-Su;Kim, Jin-Han
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.3
    • /
    • pp.5-14
    • /
    • 2018
  • This study investigated the effect of concentrate of membrane filtration of sewage reuse facilities on bioreactor's microorganisms in sewage treatment facility, and concentrate was analyzed, oxygen uptake rate and continuous activated sludge experiment were performed. As a results, the concentration of organic matter and TP concentration in concentrate was closely related to the concentration of SS and the concentration of ionic substances in concentrate was higher in order of $Cl^-$ > $Na^+$ > $Ca^{2+}$ > $K^+$ > $Mg^{2+}$ > $F^-$. And the analysis value of analytical items was greatly fluctuated according to sampling time of concentrate. Result of OUR test according to the mixing ratio of concentrate to sewage, it was found that the concentrate acts as an organic matter in the activated sludge microorganism and it increases with the increase of the concentrate mixing ratio. As a result of continuous activated sludge experiment, MLSS concentration, organic removal efficiency and TN removal efficiency gradually decreased with increasing concentrate mixing ratio. Based on the experimental results, expected mixing ratio of concentrate to affect the treatment efficiency of activated sludge is 25%.

Analysis of RCSTP And MWTP Pollutants Treatment Efficiency in Bong-Hwa Gun (봉화군 마을하수도 및 하수처리장의 오염물질 처리 효율 분석)

  • Park, Minsoo;Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.19 no.1
    • /
    • pp.69-79
    • /
    • 2017
  • Protected area of water for supply source is located mostly of rural area in Korea. Normally, sewage treatment system is poor to manage in rural, because low population and density. Rural area need sewage treatment system to supervise supply source of water. In this study, analysis on operation result of 4 RCSTP and MWTP is located at the rural area. Higher concentration of pollutant were inflows to MWTP than RCSTP, and effluent quality standard is satisfaction. However, RCSTP effluent pollutant concentrations was researched higher than MWTP. The organic matter(BOD, COD) were about 5% of a high treatment efficiency to a median. The nutrient(T-N, T-P) were detected Up to high 30%. Also, we analyzed to effect reactor operational parameters on the pollutant treatment efficiency like mixed liquer suspended solid(MLSS), dissolved oxygen(DO) and sludge retention time(SRT). As a result, pollutant treatment efficiency showed fluctuation in accordance with operating condition. Thus, it is necessary to manage the reactor operation condition for management of rural area sewage treatment.