• Title/Summary/Keyword: MJ81

Search Result 33, Processing Time 0.03 seconds

The Site Installation Test of Single-Phase MJ81 Switch Point Machine Localization (단상 MJ81 전기선로전환기 국산품의 현장설치시험)

  • Baek, Jong-Hyen;Kim, Yong-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3632-3637
    • /
    • 2009
  • In this paper, we describe the performance results of the field installation test which is required to practicalize the single-phase MJ81 Switch Point Machine. This product has passed the certified test through performance improvement of driving parts in order to use 3 phase MJ81 Switch Point Machine, which is localized by taking over technology from Alstom and Cogifer when constructing Seoul-Busan rapid-transit railway, without change of the electrical equipment at track-side in domestic existing lines which single-phase 220V is used. KRRI and Samsung SDS have localized the single-phase MJ81 Switch Point Machine to improve the speed and safety of the conventional lines through the existing railway technology development project. For practicalization of this, we should, however, verify the performance through not only field installation test in real lines but also interface test with the interlocking. In this paper we verify the practicality of the domestic single-phase MJ81 Switch Point Machine through analysis on the performance result of the field installation test as well as the research contents for this test. Thereby, in Feb 2009 we have received an order from the Korea Rail Network Authority and are currently installing the single-phase MJ81 Switch Point Machine.

The Localized Development of Single Phase MJ81 Switch Point Machine (단상 MJ81 전기선로전환기의 국산화 개발)

  • Baek, Jong-Hyen;Kim, Young-Kyu;Shin, Duc-Ko;Lee, Kang-Mi
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1181_1182
    • /
    • 2009
  • 본 논문에서는 단상 MJ81 전기선로전환기 국산화를 위한 구동부의 성능 개선 및 이의 시험에 대한 내용을 기술하고 있다. 한국철도기술연구원 및 삼성 SDS에서는 기존철도기술개발사업을 통해 기존선의 속도 및 안전성 향상을 위해 단상 모터 규격 및 신뢰성 등의 검토를 실시하였으며 국산화 개발의 타당성 검토 및 기능과 성능 규격을 제정하여 이에 따른 시험 절차를 체계화하였다. 또한 이와 병행하여 MJ81형 전기선로전환기에 사용 가능한 단상 220V 모터를 삼성SDS와 공동으로 개발 완료한 후, 종합시험장치에 개발품을 장착하여 총 20만회에 달하는 내구성 시험을 수행하여 성공적으로 성능을 입증하였다.

  • PDF

The Driving Part Performance Improvement for Single-Phase MJ8l Switch Point Machine Localization (단상 MJ81 전기선로전환기 국산화를 위한 구동부 성능 개선)

  • Baek, Jong-Hyen;Lee, Chang-Goo;Seul, Nam-O
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.3
    • /
    • pp.535-541
    • /
    • 2009
  • In this paper, we present the improvement on the performance of driving part for single-phase MJ81 switch point machine which has been developed for localization. The single-phase motor's specification and reliability for speed and safety improvement of conventional line was investigated in "Development project for Speed-up on Conventional Line" We systemized the test procedure fur single-phase motor by investigating the feasibility for localization and the specification of function and performance. Also, we developed appropriate technology and proved the durability of the single-phase driving motor by executing synthesis test over 200,000 times.

Switching power measurement of MJ81 electrical point machine using sensor (센서를 이용한 MJ81 전기선로전환기 전환력 측정)

  • LEE, Jong-Hyun;KIM, Yong-Kyu;Park, Jae-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1591-1592
    • /
    • 2015
  • 분기기는 선로가 분기되거나 또는 교차하는 지점에 설치되어 열차의 이동 방향을 안전하게 변경하는 역할을 한다. 그러나, 운영 노선 및 동작 환경에 따라 비정상적인 힘이 분기기에 발생할 경우, 정확한 진단 및 검측을 실시할 수 없는 단점이 있다. 본 논문은 국내에서 사용중인 MJ81 전기선로전환기의 전환기능과 쇄정기능의 특성 분석을 통해 기존에 사용된 분기기 전환력 측정의 문제점을 제시한 후, 이를 해결하기 위한 센서 활용 분기기 전환력 측정 방법을 제시한다.

  • PDF

A Study on Fire Spread and Evacuation Risk of Conduit Combustion in Ceiling Hiding Place (천장 은폐장소 전선관 연소에 따른 화재확산 및 피난 위험도에 관한 연구)

  • Park, Kwang-Muk;Jeon, Jae-Kam;Bang, Sun-Bae
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.55-65
    • /
    • 2020
  • In this study, the ISO 5660 and ISO 5659 combustion tests were conducted with synthetic resin conduits (CD, VE) and metal conduit (ST) used for wiring work in electrical facilities, which can be installed in ceiling concealed places. Then, fire spreading and evacuation risks were analyzed based on the measured data. In the ISO 5660 test, CD of 120.5 MJ/㎡, VE of 81.9 MJ/㎡, and ST of 4.9 MJ/㎡ were measured. In the ISO 5659 test, the CD 1320, VE 731, and ST 102 were measured, and then the maximum smoke densities were measured for CD 605 s, VE 740 s, and ST 1,200 s. In terms of fire spreading and evacuation risk, the CD conduit, VE conduit, and ST conduit were in order. In the fire spreading risk analysis, total heat emission was calculated as 4,820 MJ/㎡, 4,267 MJ/㎡, and 196 MJ/㎡ for CD, VE, and ST, respectively. Evacuation risk analysis shows at transmittance of 89%, CD is 127 s, VE is 35 s, and ST is 969 s. At transmittance of 79%, representing almost invisible concentration, CD is 157 s and VE is 50 s. The CD and VE conduits had a high fire spreading and evacuation risks, while the ST conduit had little effect on fire spreading and evacuation risk.

Studies on Reserved Carbohydrates and Net Energy Latation ( NEL ) in Corn and Sorghum III. Weender components and net enery lactation (옥수수 및 Sorghum에 있어서 탄수화물과 NEL 축적에 관한 연구. III. Weender 성분 및 Net Energy Lactation)

  • ;G. Voigtlaender
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.5 no.3
    • /
    • pp.180-186
    • /
    • 1985
  • Field and phytotron experiments were conducted to determine the effect of morphological growth stage and environmental temperature on Weender components and net energy lactation (NEL) in corn cv. Blizzard and sorghum cv. Pioneer 931 and Sioux at Munich Technical University from 1978 to 1981. Various growth stages of maize and sorghum were grown for 42 days at 4 temperature regimes (30/25, 25/20, 28/18 and 18/8 degree C) and mid-summer sunlight over 13 hour days. The results obtained are summarized as follows: 1. Accumulation of crude protein in maize and sorghum plants was associated with leaf weight ratio and leaf area ratio ($P{\leq}0.1%$). Crude protein in the plants were shown to have a greate synthesis rates at early growth stages. The highest concentration of crude protein were found at 3-leaf stage with 31.4% and 33.9% for maize and sorghum, respectively. 2. Synthesis of crude fiber was increased after growing point differentiation markedly and were shown the highest concentration at heading stage with 28.4% and 31.5% for maize and sorghum, respectively. During the maturities, the crude fiber contents in maize were, however decreased and shown a value of 19.5% at physiological maturity, while that of sorghum were increased continuously. 3. NEL value in maize and sorghum plants were declined as morphological development and shown the lowest at growing point differentiation with 5.82 MJ (maize) and 5.46 MJ/kg (sorghum). During the late maturity, the NEL value of maize were increased markedly and shown a value of 6.70 MJ and 6.94 MJ/kg for milkstage and maturity stage, respectively, while NEL value in sorghum were not increased markedly. 4. Net energy lactation in maize and sorghum plants were associated with synthesis rate of non-structural carbohydrates, especially mono- and disaccharose while cell-wall constituents and crude fiber lowerd NEL contents ($P{\leq}0.1%$). 5. NEL accumulation and starch value were decreased under temperature. The NEL concentration of 4-leaf sorghum under different environmental temperatures of 30/25, 25/20, and 18/8 degree C were 4.87 MJ, 5.46 MJ and 5.81 MJ/kg, respectively.

  • PDF

Combustion Chracteristics of the Pinus rigida and Castanea savita Dried at Room Temperature (실온에서 건조된 리기다 소나무와 밤나무의 연소특성)

  • Chung, Yeong-Jin;Jin, Eui
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.86-92
    • /
    • 2010
  • One of the limitation of wood as building materials is its flammability. The purpose of this paper is to examine the combustion properties of the Pinus rigida and Castanea savita which are grown in Korea and meet the desirable characteristics for use of construction materials. The cone calorimeter (ISO 5660-1) was used to determine the heat release rate (HRR) and fire smoke index, as well as CO and $CO_2$ production and smoke obscuration. The $HRR_{mean}$ of the Castanea savita and Pinus rigida at $50\;kW/m^2$ of radiant heat flux was $70.4\;kW/m^2$ and $68.5\;kW/m^2$. Furthermore, the THR of Castanea sativata was 120.8 MJ/kg and it was higher than the THR of Pinus rigida ($81.9\;MJ/m^$). These results are depend on the bulk density of tested wood species. The Castanea savita has high $CO_{mean}$ yield and high CO/$CO_2$ yield compared with that of Pinus rigida.

Physicochemical properties and energy content of yellow dent corn from different climatic origins in growing pigs

  • Dong, Wenxuan;Li, Juntao;Li, Zhongchao;Zhang, Shuo;Li, Xiaozhen;Yang, Chundi;Liu, Ling;Zhang, Shuai
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.11
    • /
    • pp.1787-1796
    • /
    • 2020
  • Objective: The objective of this study was to determine the digestible energy (DE) and metabolizable energy (ME) of yellow dent corn sourced from different meteorological origins fed to growing pigs and develop equations to predict the DE and ME of yellow dent corn from southwestern China. Methods: Sixty crossbred barrows were allotted to 20 treatments in a triplicate 20×2 incomplete Latin square design with 3 replicated pigs per dietary treatment during 2 consecutive periods. Each period lasted for 12 days, and total feces and urine during the last 5 days of each period were collected to calculate the energy contents. Results: On dry matter (DM) basis, the DE and ME in 20 corn grain samples ranged from 15.38 to 16.78 MJ/kg and from 14.93 to 16.16 MJ/kg, respectively. Selected best-fit prediction equations for DE and ME (MJ/kg DM basis) for yellow dent corn (n = 16) sourced from southwestern China were as follows: DE = 28.58-(0.12×% hemicellulose)+(0.35×% ether extract)-(0.83×MJ/kg gross energy)+(0.20×% crude protein)+(0.49×% ash); ME = 30.42-(0.11×% hemicellulose)+(0.31×% ether extract)-(0.81×MJ/kg gross energy). Conclusion: Our results indicated that the chemical compositions, but not the meteorological conditions or physical characteristics could explain the variation of energy contents in yellow dent corn sourced from southwestern China fed to growing pigs.

Torrefaction and Hydrothermal Carbonization (HTC) of Dead Leaves

  • Saqib, Najam Ul;Park, Seong-Kyu;Lee, Jai-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.5
    • /
    • pp.45-52
    • /
    • 2014
  • Torrefaction and hydrothermal carbonization (HTC) are productive methods to reclaim energy from lignocellulosic biomass. The hydrophobic, homogenized, energy dense and carbon rich solid fuel can be obtain from torrefaction and hydrothermal carbonization. Dead leaves were carbonized in a stainless steel reactor of volume 200 ml with torrefaction ($250-270^{\circ}C$) for 120 minutes and hydrothermal carbonization ($200-250^{\circ}C$) for 30 minutes, with mass yield solid fuel ranging from 57-70% and energy content from 16.81MJ/kg to 22.01 MJ/kg compare to the biomass. The char produced from torrefaction process possess high energy content than hydrothermal carbonization. The highest energy yield of 89.96% was obtained by torrefaction at $250^{\circ}C$. The energy densification ratio fluctuated in between 1.15 to 1.30. On the basis of pore size distribution of the chars, the definition of the International Union of Pure and Applied Chemistry (IUPAC) was used as a classification standard. The pore diameter was ranging within 11.09-19 nm which play important role in water holding capacity in soil. Larger pores can hold water and provide passage for small pores. Therefore, it can be concluded that high pore size char can be obtained my HTC process and high energy content char of 22.01 MJ/Kg with 34.04% increase in energy can be obtain by torrefaction process.

A Study on the Energy Consumption Characteristic by Building Envelope of Apartment Housing in Busan Metropolitan City (부산광역시 공동주택의 외피구조에 따른 에너지 소비특성 분석)

  • Yee, Jurng-Jae;Kim, Hwan-Yong;Kim, Seung-Hee
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.75-81
    • /
    • 2014
  • In this paper we made energy consumption units of glass curtain wall type apartment and general apartment in Busan metropolitan city and compared energy consumption characteristics by building envelope. The monthly electricity consumption units of general apartment were shown in the range of $1.16{\sim}1.51kWh/m^2{\cdot}mon$ which were indicated higher value in January, February, August and September with little variation. On the other hand, in case of glass curtain wall type apartment, monthly electricity consumption units were represented in the range of $1.91{\sim}7.07kWh/m^2{\cdot}mon$ with significant fluctuations monthly, which were outstandingly high in July, August and September. The monthly city gas consumption units of general apartment were found to be in the range of $1.79{\sim}18.07MJ/m^2{\cdot}mon$, while glass curtain wall type apartment were within $0.94{\sim}19.91MJ/m^2{\cdot}mon$. City gas consumption units from December to March were shown highly in both type apartments. The monthly energy consumption units of general apartment were found to be within $14.23{\sim}30.69MJ/m^2{\cdot}mon$, while glass curtain wall type apartment were within $24.49{\sim}68.9MJ/m^2{\cdot}mon$. Energy consumption units of glass curtain wall type apartment were suggested 4.84 times higher than those of general apartment.