• Title/Summary/Keyword: MIN module

Search Result 1,198, Processing Time 0.025 seconds

The Effect of EVA Sheet Gel Content on Photovoltaic Modules Durability (EVA Sheet의 Gel Content가 태양전지모듈의 내구성에 미치는 영향)

  • Kang, Gi-Hwan;Park, Chi-Hong;Kim, Kyung-Soo;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.20-21
    • /
    • 2006
  • In this paper, we studied the influence of EVA sheet gel content on photovoltaic module durability. Depending on thermal curing temperature and time during lamination, there are dramatic changes on chemical and physical characteristics. To find the optimum PV module process condition, Glass/EVA/Back Sheet scheme was made. Gel Content, FT-IR spectrum and SEM were used for the detail analysis. From these results, $110^{\circ}C/6min$ and $130^{\circ}C/4min$ lamination condition could be suggested for the best one for durable PV module processing. The further analysis is described in the following paper.

  • PDF

A study on the integration of Rf switch module using LTCC technology (LTCC 기술을 이용한 RF Switch Module의 집적화에 관한 연구)

  • Kim, Ji-Young;Kim, In-Sung;Min, Bok-Ki;Song, Jae-Sung;Suh, Young-Suk;Nam, Hyo-Duk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.710-713
    • /
    • 2004
  • The design, simulation, modeling and measurement of a low temperature co-fired ceramic (LTCC) RF switch module for GSM applications is presented in this paper. RF switch module is constructed using a Rx/Tx switching circuit and integrated low pass filter. The low pass filter function was designed to operate in th GSM band. Insertion and return loss of the low pass filter were designed less than 0.3 dB and better than 12.7 dB at 900 MHz. The RF switch module contained 10 embedded passives and 3 surface mount components integrated on $4.6{\times}4.8{\times}1.2$ nm, 6-layer multi-layer integrated circuit. The insertion loss of switch module was measured at 900 MHz was 11 dB.

  • PDF

Fabrication of Shingled Design Bifacial c-Si Photovoltaic Modules (슁글드 디자인 고출력 양면수광형 단결정 실리콘 태양광 모듈 제작)

  • Park, Min-Joon;Kim, Minseob;Shin, Jinho;Byeon, Su-Bin;Jeong, Chaehwan
    • Current Photovoltaic Research
    • /
    • v.10 no.1
    • /
    • pp.1-5
    • /
    • 2022
  • Bifacial photovoltaic (PV) technology has received considerable attention in recent years due to the potential to achieve a higher annual energy yield compared to its monofacial PV systems. In this study, we fabricated the bifacial c-Si PV module with a shingled design using the conventional patterned bifacial solar cells. The shingled design PV module has recently attracted attention as a high-power module. Compared to the conventional module, it can have a much more active area due to the busbar-free structure. We employed the transparent backsheet for a light reception at the rear side of the PV module. Finally, we achieved a conversion power of 453.9 W for a 1300 mm × 2000 mm area. Moreover, we perform reliability tests to verify the durability of our Shingled Design Bifacial c-Si Photovoltaic module.

A Study on the Development of Auto Training System with Training Assistance and Training Information Monitoring (운동 보조 및 운동 정보 모니터링이 가능한 오토 트레이닝 시스템 개발에 관한 연구)

  • Baek, Jun-Young;Go, Seok-Jo;Kim, Tae-Hun;Yoon, Sung-Min;No, Chi-Beom;Cha, Byung-Su;Lee, Min-Cheol
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.20 no.4
    • /
    • pp.333-338
    • /
    • 2017
  • In recent years, there has been an increasing demand for healthcare services that can periodically monitor health status and maintain health by increasing the weight training population. However, injuries in the absence of trainer are increasing with the increase in the number of members in the fitness training center. Therefore, there is a need for a system that can periodically monitor the user's exercise state and assist in systematic and safe exercise even when the trainer is absent. In this study, we developed an auto training system that can effectively manage the exerciser while supporting the strength movement. The auto training system consists of a cable mount module, a control module, and a training information monitoring module. In order to evaluate performance of the developed system, the assistant force tests are carried out. Experimental results showed that the assistant force works well when the exerciser is out of power.

Vibration test and verification of Multi-Anode-Photo-Multiplier-Tube's survivability with X-Ray Coded Mask Gamma Ray Burst Alert Trigger mechanical system in space launch environment

  • Choi, Ji Nyeong;Choi, Yeon Ju;Jeong, Soomin;Jung, Aera;Kim, Min Bin;Kim, Ji Eun;Kim, Sug-Whan;Kim, Ye Won;Lee, Jik;Lim, Heuijin;Min, Kyung Wook;Na, Go Woon;Nam, Ji Woo;Park, Il Hung;Ripa, Jakub.;Suh, Jung Eun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.209.2-209.2
    • /
    • 2012
  • UFFO Burst Alert & Trigger telescope (UBAT) is one of major instruments of UFFO-Pathfinder. The UBAT aims at 10 arcmin resolution localization of Gamma Ray Bursts with X-ray coded mask technique. It has $400mm{\times}400mm$ coded mask aperture, hopper, shielding and detector module with effective area of $191cm^2$. The detector module consists of an assembly of 36 64-ch MAPMTs and $25mm{\times}25mm$ pixellated YSO crystal array, and associated analog and digital electronics of about 2500 channels. We performed a vibration test using a dummy MAPMT with the detector module structure to measure the indused stress applied onto the MAPMT. We designed a sub-structure on the detector module to avoid the resonance that would otherwise deforms the detector module structure. A finite element analysis confirms the reduction of the load acceleration down to 12g. The experimental results are to be reported. Consequently, it proves that the MAPMT arrays of the flight UBAT detector module structure would survive in the space launch environment.

  • PDF

Development of a Returnable Folding Plastic Box RFID Module for Agricultural Logistics using Energy Harvesting Technology (에너지 하베스팅 기술을 활용한 농산물 물류용 리턴어블 접이식 플라스틱 상자 RFID 모듈 개발)

  • Jong-Min Park;Hyun-Mo Jung
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.3
    • /
    • pp.223-228
    • /
    • 2023
  • Sustainable energy supplies without the recharging and replacement of the charge storage device have become increasingly important. Among various energy harvesters, the triboelectric nanogenerator (TENG) has attracted considerable attention due to its high instantaneous output power, broad selection of available materials, eco-friendly and inexpensive fabrication process, and various working modes customized for target applications. In this study, the amount of voltage and current generated was measured by applying the PSD profile random vibration test of the electronic vibration tester and ISTA 3A according to the time of Anodized Aluminum Oxide (AAO) pore widening of the manufactured TENG device Teflon and AAO. The discharge and charging tests of the integrated module during the random simulated transport environment and the recognition distance of RFID were measured while agricultural products (onion) were loaded into the returnable folding plastic box. As a result, it was found that AAO alumina etching processing time to maximize TENG performance was optimal at 31 min in terms of voltage and current generation, and the integrated module applied with the TENG module showed a charging effect even during the continuous use of RFID, so the voltage was kept constant without discharge. In addition, the RFID recognition distance of the integrated module was measured as a maximum of 1.4 m. Therefore, it was found that the surface condition of AAO, a TENG element, has a great influence on the power generation of the integrated module, and due to the characteristics of TENG, the power generation increases as the surface dries, so it is judged that the power generation can be increased if the surface drying treatment (ozone treatment, etc.) of AAO is applied in the future.

Preliminary study of Angle sensor module for Vehicle Steering System Based on Multi-track Encoder (자동차 조향장치용 TAS module을 위한 Multi-track Encoder기반 신호처리보드의 구현)

  • Woo, Seong Tak;Han, Chun Soo;Baek, Jun Byung;Lee, Sang-hoon;Jung, Min Woo;Choo, Sung Joong;Park, Jae Roul;Yoo, Jong-Ho;Jung, Sanghun;Kim, Ju Young
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.432-437
    • /
    • 2017
  • As 4.0 industry has been developed, research on a self-driving car technology and related parts of an automobile has been highly investigated recently. Particularly, a TAS(Torque Angle Sensor) module on steering wheel system has been considered as a key technology because of its precise angle, torque detection and high speed signal processing. The environmental assessment is generally required on the TAS module to examine high resolution of angle/torque detection. In the case of existing TAS module, angle detection errors has been occurred by back-lash on main and sub gear in addition to complicated structure caused by gears. In this paper, a structure of the TAS module, which minimizes the numbers of components and angle detection errors on the module compared with the existing TAS module, for vehicle steering system based on a Multi-track Encoder has been proposed. Also, angle detection signal processing board, and key technology of the TAS module were fabricated and evaluated. As a result of the experiments, we confirmed an excellent performance of the fabricated signal processing board for angle detection and an applicability of the fabricated angle detection board on the TAS module of vehicles by the environmental assessment an automobile standard.

A Study on Satisfaction Evaluation of Korean Medicine Therapy Using Treatment Tool by Psychological Type (심리유형별 진료도구를 이용한 한방치료의 만족도 평가 연구)

  • Ji, Young Seung;Lee, Seung Min;Kim, Jeong Ho;Nam, Seung Kyu;Kim, Young Il
    • Journal of Acupuncture Research
    • /
    • v.30 no.3
    • /
    • pp.27-38
    • /
    • 2013
  • Objectives : This study was designed to evaluate patient satisfaction of Korean medicine therapy using treatment tool by psychological type. Methods : 48 subjects were participated in this study. Before a treatment, we analyzed a patient's phychological type first by using a questionnaire. And then we divided 3 groups which were called a rational sympathy module group, emotional sympathy module group, control group. Manner of medical consultation according to patient's phychological type was carried out in all groups. After all treatment, we conducted a survey about medical service perception index, patient happiness index, medical satisfaction index. To evaluate a satisfaction degree, we analyzed results of survey statistically. Results : The results of the analysis, both rational sympathy module group and emotional sympathy module group got a higher score than control group statistical significantly on medical service perception index. Emotional sympathy module group got a higher score than control group statistical significantly on patient happiness index and medical satisfaction index. But rational sympathy module group only had a higher tendency than control group on patient happiness index and medical satisfaction index. Emotional sympathy module group got a higher score than rational sympathy module group on medical service perception index, patient happiness index and medical satisfaction index. Conclusions : Korean medicine therapy using treatment tool by psychological type consisted of patient's phychological type questionnaire and manner of medical consultation could improve a patient's satisfaction. It was more effective in emotional sympathy module group than rational sympathy module group.

A Preliminary Research of the Bifacial PV System Under Installation Conditions (설치환경 및 조건에 따른 양면수광형 태양광발전시스템의 기초 특성 연구)

  • Jang, Ju-Hee;Kwon, Oh-Hyun;Lee, Sang-Hyuk;Shin, Min-Su;Lee, Kyung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.6
    • /
    • pp.51-63
    • /
    • 2018
  • Nowadays the bifacial PV system market and its applications are increasing rapidly. The performance of the bifacial PV system take advantage of its rear surface irradiance. Also, the ground albedo, PV module tilt and azimuth, PV module installation height, shading effect and module temperature are factors of bifacial PV system performance. This paper investigates how the performance of bifacial PV system is influenced by above factors. First, we analyzed the energy yield depending on PV module installation by simulation. Secondly, we compare energy performance evaluation of monofacial and bifacial module on different weather condition by experiment. Thirdly, we tested the albedo effect and checked operating characteristics using Dupont Tyvek material for the bifacial PV module. Fourthly, we check the shading effect of bifacial PV module on bypass diode operating. Finally, we applied the bifacial PV module in the nearby subway station for the noise reduction barrier using a qualified simulation program. In summary, we confirm that the energy performance superiority of the bifacial PV module has a lot of application use including road. Also, we have confirmed the bifacial module and inverter design should be considered by rear surface irradiance.

Studies of Performance and Enlarged Capacity through Multi-stages Stacked Module in Membrane Capacitive Deionization Process (막 축전식 탈염 공정의 다단 적층 모듈을 통한 처리 용량 증대 및 이의 성능 연구)

  • Song, Yye jin;Yun, Won Seob;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.27 no.5
    • /
    • pp.449-457
    • /
    • 2017
  • In this study, the 10 stages stacked module was designed by increasing the number of unit cells in the membrane capacitive deionization(MCDI) process. The aminated polysulfone and sulfonated poly(ether ether ketone) were synthesized and coated on porous carbon electrode by casting method. The salt removal efficiency was measured for the 10 stage stacked module under the operation conditions of adsorption voltage and time, desorption voltage and time, flow rate and concentration of feed water, and di-valent solutions including $CaSO_4$, $MgCl_2$ and tap water. Typically, when 100 mg/L of NaCl as the feed was used, the salt removal efficiency was 98.3% at a flow rate of 100 mL/min, the adsorption condition of 1.2 V/3 min and desorption condition of -0.5 V/5 min.