• Title/Summary/Keyword: MIK

Search Result 14, Processing Time 0.03 seconds

Study on quench detection of the KSTAR CS coil with CDA+MIK compensation of inductive voltages

  • An, Seok Chan;Kim, Jinsub;Ko, Tae Kuk;Chu, Yong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.1
    • /
    • pp.55-58
    • /
    • 2016
  • Quench Detection System (QDS) is essential to guarantee the stable operation of the Korea Superconducting Tokamak Advanced Research (KSTAR) Poloidal Field (PF) magnet system because the stored energy in the magnet system is very large. For the fast response, voltage-based QDS has been used. Co-wound voltage sensors and balanced bridge circuits were applied to eliminate the inductive voltages generated during the plasma operation. However, as the inductive voltages are hundreds times higher than the quench detection voltage during the pulse-current operation, Central Difference Averaging (CDA) and MIK, where I and K stand for mutual coupling indexes of different circuits, which is an active cancellation of mutually generated voltages have been suggested and studied. In this paper, the CDA and MIK technique were applied to the KSTAR magnet for PF magnet quench detection. The calculated inductive voltages from the MIK and measured voltages from the CDA circuits were compared to eliminate the inductive voltages at result signals.

Numerical estimation on balance coefficients of central difference averaging method for quench detection of the KSTAR PF coils

  • Kim, Jinsub;An, Seok Chan;Ko, Tae Kuk;Chu, Yong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.3
    • /
    • pp.25-29
    • /
    • 2016
  • A quench detection system of KSTAR Poloidal Field (PF) coils is inevitable for stable operation because normal zone generates overheating during quench occurrence. Recently, new voltage quench detection method, combination of Central Difference Averaging (CDA) and Mutual Inductance Compensation (MIK) for compensating mutual inductive voltage more effectively than conventional voltage detection method, has been suggested and studied. For better performance of mutual induction cancellation by adjacent coils of CDA+MIK method for KSTAR coil system, balance coefficients of CDA must be estimated and adjusted preferentially. In this paper, the balance coefficients of CDA for KSTAR PF coils were numerically estimated. The estimated result was adopted and tested by using simulation. The CDA method adopting balance coefficients effectively eliminated mutual inductive voltage, and also it is expected to improve performance of CDA+MIK method for quench detection of KSTAR PF coils.

A Study on Signal Integrity of High Speed Interface for Ultra High Definition Video Pattern Control Signal Generator (초고해상도 영상패턴 제어 신호발생기의 고속 인터페이스 신호 무결성 실험에 관한 연구)

  • Son, Hui-Bae;Jun, June-Su;Kwon, Sai-Hoan
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2014.06a
    • /
    • pp.150-152
    • /
    • 2014
  • 디지털 평판 LCD TV의 영상신호 전송에 LVDS가 사용되어 왔으나 케이블간의 타이밍 문제가 대두되고 초고해상도의 컬러 Depth 확장으로 인해 보다 빠른 전송속도가 요구되어진다. V-by-One HS는 초고해상도 영상처리 IC 및 TCON 간의 새로운 인터페이스 기술로서 최대 3840*2160@240Hz의 해상도 영상구현이 가능하다. 동작 주파수 대역의 공진모드 전압 분포와 V-by-One HS IBIS(Input/Output Buffer Information Specification) 모델 시뮬레이션을 통하여 PCB 설계 방법을 제안한다. 본 논문에서는 V-by-One HS 인터페이스 기술을 사용하여 초고해상도 영상패턴 제어 신호발생기의 시스템 구성을 제안하고 고속영상 신호에 대한 신호 무결성을 검증하고자 한다.

  • PDF

MIXED-MODE CRACK PROPAGATION BY MOVABLE CELLULAR AUTOMATA METHOD

  • Pak, Mik-Hail;Lee, Choon-Yeol;Chai, Young-Suck
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1754-1759
    • /
    • 2007
  • Propagation of a mixed-mode crack in Soda-Lime silica glass using Movable Cellular Automata (MCA) method is demonstrated in this study. In MCA method, special fracture criterion is used to describe the process of crack initiation and propagation. Comparison between MCA and other crack initiation criteria results are made. The crack resistance curves and bifurcation angles under different loading angles are found. In comparisons with results of maximum circumferential tensile stress criterion, MCA result showed the sufficient agreement.

  • PDF

Analysis of Signal Integrity of High Speed Serial Interface for Ultra High Definition Video Pattern Control Signal Generator (UHD급 영상패턴 제어 신호발생기를 위한 고속 시리얼 인터페이스의 신호 무결성 분석)

  • Son, Hui-Bae;Kweon, Oh-Keun
    • Journal of Broadcast Engineering
    • /
    • v.19 no.5
    • /
    • pp.726-735
    • /
    • 2014
  • In accordance with 4K UHD(Ultra High Definition) LCD television's higher resolution and data expansion, LCD TV had to face problems such as increasing numbers of cables and tangible skews problems among cables. The V-by-One HS is a new interface technology in the path between the image processing IC and timing control (TCON) board. The variable speed from 600 Mbps to 3.75 Gbps effectively meets the requirements of various different pixel rates. In this paper, we use the V-by-One HS interface to illustrate our proposed simulation method of frequency resonance mode and PCB design approach to model the effects of signal integrity for high speed video signal using an IBIS models.

Analysis of stealth design for naval vessels with wide band metamaterials (함정의 스텔스 설계를 위한 광대역 메타물질 적용 연구)

  • Hwang, Joon-Tae;Hong, Suk-Yoon;Kwon, Hyun-Wung;Song, Jee-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.11
    • /
    • pp.2206-2212
    • /
    • 2017
  • When it comes to naval surface warfare, the probability of detection is an important factor in survivability and the Radar Cross Section(RCS) is a major parameter. In this paper, the RCS reduction technology of the Radar Absorbing Material(RAM) method is carried out for the general frequency range for naval warfare. We set the analysis model with the simplified ship model and the wide band metamaterial which is high-tech radar absorbing materials is selected for the RAM method. The modeling of the wide band metamaterial composed of an MIK surface which has the wide band resonant properties and flexible substance and the electromagnetic absorptions and reflections of the wide band metamaterial has been simulated to explore the performance. Also, the wide band metamaterial is compared with the paint absorber to analyze RCS reduction in terms of RCS values.

Energy Efficiency & Sustainability - the Cleanliness Management Role of Components and System in Automotive and Hydraulics

  • Day, Mik;Hong, Jeong-Hee
    • Journal of Drive and Control
    • /
    • v.9 no.2
    • /
    • pp.46-53
    • /
    • 2012
  • This paper explains how eliminating contamination from the manufacturing processes will lead to better product quality and hence the need for reworking, a trouble free commissioning period and greatly improved production efficiency. All of these will reduce costs and energy usage. It will also ensure that the product is delivered to the customer in a condition that will ensure improved reliability and longer life, again reducing both energy and other operating costs. Correctly designing the contamination control measures will achieve and maintain the level of fluid cleanliness that is required by the end user. The filter is critical to cleanliness management and should be selected with the same degree of thought and consideration as for other major components. This paper explains the role that Cleanliness Management plays in the reducing the carbon footprint of systems and processes by making them perform more efficiently for longer periods. It also examines two differing ways of selecting filters to incorporate the features of newer designs, and shows how significant savings in the costs of ownership can be achieved using these approaches.

A Study on the Library Space in the Emerging Ubiquitous Environment (유비쿼터스 시대 도서관 공간에 관한 연구)

  • Cha, Mik-Yeong
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.17 no.1
    • /
    • pp.325-343
    • /
    • 2006
  • The library space has historically been influenced by the change of its information and social environment. This paper describes the effect of ubiquitous environment on the library's space, by literature review, case analysis. and focus-group interview of 5 undergraduate students. The results show that the library's physical place is still important for users, and suggest the library information space design and management need to reflect the open-ness and the interactive-ness of the ubiquitous space.

Fabriation of Smart Window Using PDLC (PDLC를 이용한 스마트 윈도우 제작)

  • Kang, Mik-Ki;Yun, Tae-Uk;Han, Ga-Ram;Jang, Jae-Hoon;Kim, Chang-Kyo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.158-158
    • /
    • 2010
  • 최근 유리산업은 에너지 절감효과와 친환경 재료의 사용을 바탕으로 하여 기존 유리의 특성을 변화시켜 보다 양질의 재료를 생산해 내고자 한다. 또한 인위적으로 가시광선 전파장에 대한 투과율을 조절할 수 있는 유리 제작의 필요성이 대두되어 스마트 윈도우(smart window)라는 신소재유리가 주목받고 있다. 스마트 윈도우는 태양광의 투과율을 자유롭게 조절할 수 있는 물질을 윈도우에 삽입함으로써 필름을 장착하는 방식에 비하여 태양광의 투과율이 대폭 신장됨과 동시에 사용자에게 고도의 편의성을 제공하는 장점이 있다. 액정과 고분자 매트릭스를 혼합한 PDLC용액을 이용하여 $3{\times}4cm^2$ 크기의 스마트 윈도우를 제작하여 유리 두께, 광량, 스페이서 크기에 따른 투과율을 측정하였다.

  • PDF

The AS4059 Hydraulic System Cleanliness Classification System: Replacement of NAS1638

  • Day, Mik;Hong, Jeong-Hee
    • Journal of Drive and Control
    • /
    • v.9 no.2
    • /
    • pp.39-45
    • /
    • 2012
  • The NAS 1638 cleanliness classification system was originally developed in 1966 by the US Aircraft Industries of America to both simplify reporting of particle count data and to control the introduction of dirt during the assembly of aircraft fluid systems. The numbers of particles at stated sizes are represented by broad bands where the interval was generally a doubling of contamination. A number of systems have been introduced since this to suit differing requirements. NAS 1638 and AS4059 are used in other industrial sectors such as the Off-shore & Sub-Sea and the Primary Metal Industries. The changes to ISO contamination measurement standards controlled by ISO/TC131/SC6 in 1999 meant that a revision of most of these classification systems was necessary. The body responsible for NAS 1638 decided to withdraw it for new installations and replace it with an update of an existing standard, SAE AS 4059. This paper details the philosophy behind the contamination coding systems, the reasons for the changes to the ISO contamination standards and explains the workings of AS 4059, the replacement for NAS 1638. It goes on to detail the latest changes to this standard.