• Title/Summary/Keyword: MICROCLIMATE

Search Result 356, Processing Time 0.026 seconds

Efficacy of Cooling Vest for Auxiliary Body Cooling in Hot Environments(2) - Comparison in Terms of Thermophysiological Properties Between New Cooling Vest and Standard Cooling Vest - (고온환경 하에서 착용하는 인체냉각 보조도구로서의 Cooling Vest연구(2) - 개발제품의 온열생리학적특성 -)

  • Kwon, Oh-Kyung;Kim, Tae-Kyo;Kim, Jin-A
    • Fashion & Textile Research Journal
    • /
    • v.2 no.4
    • /
    • pp.346-352
    • /
    • 2000
  • The purposes of this study are finding out thermophysiological properties throughout wearing experiment with standard cooling vest as well as providing data in order to design and apply more comfortable cooling vest. To do this study, we produced cooling vest newly. 1. Rectal temperature was ascended approximately from $37.2^{\circ}C$ to $38.05^{\circ}C$ in lab, but wearing cooling vest, the temperature was descended 0.2 while wearing developed product compare with existing product. Mean skin temperature which was showed distribution from $32.8{\sim}36.5^{\circ}C$, it was descended $1.0{\sim}1.1^{\circ}C$, while wearing cooling vest and comparing with existing product, wearing developed product was lower $0.5^{\circ}C$. 2. While wearing developed cooling vest, it was found that they had lower tendency than standard cooling vest. Specifically in case of temperature within clothing (chest) $0.2{\sim}2.0^{\circ}C$ in case of humidity within clothing 2~8%RH. Facts from above we confirmed that clothing microclimate had been improved and space was happened between body and garment in order to control. 3. In subjective sensation, standard cooling vest made negative response during experiment period from participants, but new cooling vest was nearing to comfortable area. It was con finned from above conclusions that wearing developed product is more effective in terms of comfort and reduction of heat stress in situation of working in hot environment.

  • PDF

The Influence of Wearing Army Combat Uniform on the Thermal Responses in Heat Environment (서열환경하에서의 전투복착용이 체온조절에 미치는 영향)

  • Kim, Tae Gyou;Cho, Ho Hyun
    • Fashion & Textile Research Journal
    • /
    • v.16 no.1
    • /
    • pp.167-174
    • /
    • 2014
  • The physical properties of textile materials and thermal physiological responses of the human subjects were evaluated with 4 different types of the army combat uniforms including US, German, Korean and general uniforms for this study. 8 male adults were used as the human subjects and the tests were done in the environmental chamber that was $25{\pm}0.1^{\circ}C$ of temperature, $65{\pm}5%$ of relative humidity and below 0.3 m/sec of air velocity. The test protocol consisted the rest period for 20 min., the exercise period for 20 min., the rest period for 20 min., the exercise period under wind condition for 20 min., and the recovery period for 20 min. The human subjects walked with 4.5 km/hr for 10 min., ran 7.5 km/hr for 10 min. during the first exercise period and walked and ran with the same speeds under 3.5 m/sec of the air velocity that simulated outdoor condition during the second exercise period. The test results of the study were as follows; The wind condition affected the skin and microclimate temperature of the human subjects lower compared to without wind condition, but had insignificant effect on the humidity control. The low air permeability of Korean uniform caused blocking the elimination of the humidity from the body and the regulation of body temperature. However, Korean uniforms could be the excellent one with the designs considering the ventilation of the uniforms and the textile fabrics with better air permeability.

Thermoregulatory Responses of Differently Designe Cleanroom Garments (고청정 작업환경에서 방진복 디자인이 인체 생리반응에 미치는 영향)

  • 이윤정;정찬주;정재은
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.6
    • /
    • pp.811-820
    • /
    • 2002
  • The physical responses and subjective sensations of different cleanroom garments were compared in order to discover which cleanroom garment design could minimize pollution of the working environment by dust from the worker, maintain a pleasant microclimate and provide effective thermoregulation. A. Coverall with non-detachable hood, kimono sleeves (front), raglan sleeves (back), raschell net on the bodice B. Coverall with detachable hood, kimono sleeves (front), raglan sleeves (back), raschell net on the bodice C. Separate top with non-detachable hood, kimono sleeves (front), raglan sleeves (back), raschell net on the bodice D. Coverall with non-detachable hood, set-in sleeves, raschell net on the bodice E. Coverall with non-detachable hood, raglan sleeves (back), l00% cotton inner wear (upper body) The results of the experiment were as follows. Because the hood covered the shoulder and the chest areas, the chests temperature of the worker wearing garment E was quite higher than those wearing other garment designs. For fabric that has been coated in order to prevent dust, layered designs should be avoided in order to prevent skin temperature from rising. Compared with layers of underwear, it would be more effective to attach a see-through raschell net which clings to the body. Thermal sensations were also highest in garment E, reinforcing the finding that layered designs should be avoided. Through the experiment, it was found that a new material coverall with a non-detachable hood was effective in minimizing dust, suppressing skin temperature increases, maintaining a superior microclimate and providing pleasant subjective sensations.

A Study on Wearing Test of Protective Clothing against a Toxic Substance (유해물질 차단을 위한 방호복의 착용실험에 관한 연구)

  • Chung, Myung-Hee;Park, Soon-Ja;Shin, Jung-Sook;Koshiba, Tomoko;Tamura, Teruko
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.11 s.158
    • /
    • pp.1626-1635
    • /
    • 2006
  • The purpose of this study was to search for comfortable protective clothing for waste incinerator workers. The experimental protective clothing came in two types: one whose outer side made use of polypropylene film, and the inner side, a non-woven rayon fabric processed with charcoal with a 10% density (CF): and one whose outer side made use of polyolefine and polyamide films, and the inner side, a non-woven polypropylene fabric (NNCF). Experiments were conducted on five healthy adult women whose average age was 21. These experiments were conducted at a climate chamber, in which the temperature and relative humidity were set below $28{\pm}1^{\circ}C\;and\;50{\pm}10%$, respectively. Measured were the rectal temperature, the skin temperature, the sweating rate, the weight loss, the heart rate, the blood pressure, the temperature, and the relative humidity of a microclimate and subjective sensation. These were measured within a period of 60 min, consisting of a 20-min stable period, a 20-min exercise period (walking exercise for 2 miles/hr on a treadmill), and a 20-min recovery period. Through this experiment, the differences between the human body's physiological reactions to CF and NNCF clothing, and the human body's comfort levels when wearing these, were determined.

The use and potential applications of point clouds in simulation of solar radiation for solar access in urban contexts

  • Alkadri, Miktha F.;Turrin, Michela;Sariyildiz, Sevil
    • Advances in Computational Design
    • /
    • v.3 no.4
    • /
    • pp.319-338
    • /
    • 2018
  • High-performing architecture should be designed by taking into account the mutual dependency between the new building and the local context. The performative architecture plays an important role to avert any unforeseen failures after the building has been built; particularly ones related to the microclimate impacts that affect the human comfort. The use of the concept of solar envelopes helps designers to construct the developable mass of the building design considering the solar access and the site obstruction. However, the current analysis method using solar envelopes lack in terms of integrating the detailed information of the existing context during the simulation process. In architectural design, often the current site modelling not only absent in preserving the complex geometry but also information on the surface characteristics. Currently, the emerging applications of point clouds offer a great possibility to overcome these limitations, since they include the attribute information such as XYZ as the position information and RGB as the color information. This study particularly presents a comparative analysis between the manually built 3D models and the models generated from the point cloud data. The modelling comparisons focus on the relevant factors of solar radiation and a set of simulation to calculate the performance indicators regarding selected portions of the models. The experimental results emphasize an introduction of the design approach and the dataset visibility of the 3D existing environments. This paper ultimately aims at improving the current architectural decision of support environment means, by increasing the correspondence between the digital models for performance analysis and the real environments (context of design) during the conceptual design phase.

Physiological Responses and Subjective Sensations by Age through Seasonal Condition (환경온도에 따른 착의 생리반응과 주관적 감각의 연령별 비교)

  • Lee, Jung-Sug;Song, Min-Kyu;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.11 no.5
    • /
    • pp.833-839
    • /
    • 2009
  • This study was to investigate the human's physiological responses and subjective sensations with wear trial through seasonal condition by age. Climate chamber was set $5^{\circ}C$, RH 45% for winter and $30^{\circ}C$, RH 65% for summer condition. Thirty male subjects were volunteered consisted of 10 people in their 20s, 40s, and 60s. In this study physiological responses such as rectal temperature, skin temperature, clothing microclimate, heart rate and blood pressure were measured. As for age, 60s was the highest in rectal temperature regardless of seasonal condition. In skin temperature, 40s was the highest in winter and 20s was the highest in summer. In clothing microclimate temperature and heart rate, 20s was the highest regardless of seasonal condition. And blood pressure was appeared the highest in 20s regardless of seasonal condition. Subjective sensations such as temperature sensation, wetness sensation and thermal comfort were measured. The subjects revealed that temperature sensation was higher 20s than 60s. Compare of other age group, 60s felt colder in the same environment and clothing. It suggested that temperature susceptibility in 60s became weakened showing no change sensation during the cold exposure. Wetness sensation was higher 20s than 60s. Thermal comfort of 60s was felt more discomfortable than any other age group. This means require the supplement of a suitable clothing in order to adjust to change of environmental conditions.

Thermal Properties on combination of Velvet and Lining (벨벳과 안감의 소재 조합에 따른 의복의 열저항에 관한 연구)

  • 계명대학교의류학과;이욱자;류덕환
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.1
    • /
    • pp.3-13
    • /
    • 1999
  • This study was performed for purpose of getting fundamental information requisite to wear velvet clothes that is more comfortable for the human body and also the environment. It was carried out in a human wearing test and thermal manikin test at the same time in a controlled-condition chamber. The experimental environment had a ambient temperature of 15$\pm$0.5$^{\circ}C$ with the relative humidity at 5$^{\circ}C$$\pm$5% and with air velocity at less that than 0.2m/sec. Velvet differ from common plain weaves in thermal properties because it's constructed in two parts one is ground part and the other part is pile part. In order to investigate the thermal resistance of velvet eight different combination of 4 velvet kinds and 2 lings kinds as experimental clothes. [(4 velvet kinds : Acetate cuprammoium Rayon Cotton Wool) (2 lining kinds : acetate viscose rayon)longrightarrow8 combination: Aa, Av, Ra, Rv, Ca, Cv, Wa, Wv: the simplified character] The results of this study can be summarized as follows : 1. For the regional thermal resistance the differences in eight clothes as well as differences in each part were significant. As a whole the breast part showed the highest thermal resistance and the leg part was higher than the shank part. The rank of the total thermal resistance was put at Wa>Wv>Ca>Cv>Aa>Av>Ra>Rv in this order. 2. Considered clothing microclimate microclimate temperature has a similar tendency to the total thermal resistance. It showed a significance in the differences of eight clothes and each parts. the belly part was highest in every combination. On the other hand for clothing humidity there was a significance between back and breast part only in the human wearing test. 3. It was indicated that CLO value was highly positively correlated with the clothings' weight and showed a high negative correlation with the air permeability.

  • PDF

Efficiency and Comfort Properties of Silicon Solar Cell Applied Air Circulation Jacket according to the Incident Angle of Sunlight (실리콘 태양전지를 활용한 공기순환 의복의 태양광 입사각에 따른 효율성 및 쾌적성평가)

  • Lee, Ji-Yeon;Cho, A-Ra;Jung, Ye-Lee;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.11
    • /
    • pp.1806-1816
    • /
    • 2009
  • This study analyzes the efficiency of a solar cell attached to an air circulation jacket. A commercially available silicon solar panel was selected and attached at four spots where the body angle was $40-60^{\circ}$ and voltage ($V_{oc}$, V), current ($I_{sc}$, A), and output power (P, W) were measured to determine the efficiency. The solar panel was applied to the outer jacket that operates with two fans to increase the convection that lowers the body temperature. The heavy work of standing, walking, and sweeping of a street sweeper was simulated in the field test. The microclimate within the jacket (with or without a fan) was measured and the subjective thermal, humidity, and comfort sensations were surveyed. SPSS 12.0 statistical package was used for a t-test and Wilcoxon signed-rank test. The results show that the highest efficiency of the solar cell was at the incident angle of $60^{\circ}$ in terms of voltage, current and output power distribution. The microclimate temperature of the air circulation jacket decreased significantly with the high power of the fan and subjects felt cooler than the jacket with a fan at the incident angle of $60^{\circ}$. Air circulation jackets operated by a silicon solar panel showed a significant cooling effect on the wearers.

Ventilation and Comfort Sensation by Slit Positions of Running Wear Jackets (러닝웨어 재킷의 슬릿 위치가 통기성과 착용감에 미치는 영향)

  • Lim, Ji-Hye;Roh, Eui-Kyung;Yoo, Hwa-Sook;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.11
    • /
    • pp.1794-1805
    • /
    • 2009
  • This study investigates the influence of slit positions on the microclimate temperature/humidity of garments. To design the slits, a market survey was performed to indicate the method to apply the slits, in addition to a literature survey about muscles and body surface variation through body movements. Based on the survey, three positions of slits were selected, shoulder slit, lowback slit, and midback slit, a slit width of 1cm and length to 30cm was used. The results showed that microclimate temperatures/humidity on the back according to the slit positions were in the order of, lowback, midback, and the shoulder. The lowback slit showed the highest effect on the temperature/humidity of a front trunk. Lowback slits affected on localized areas of the glutaeus maximus, erector spinae, and latissimus dorsi. Midback slits affected the back muscle and deltoid. Shoulder slits showed a more significant effect on the localized area of the deltoid versus other localized areas. In the subjective sensations, the lowback slit was cooler, dryer, and more comfortable than the other slits. For the subjective sensations by fabric characteristics, the slit positions correlated at |r|${\geq}.8$ and were significant at p<.001 The results show that the lowback slit has a superior air exchange effect and thermoregulation qualities.

Influences of Wearing Far-infrared Indoor Clothing on Skin Blood Flow, Perceptual and Thermal Responses (원적외선 방사 기능 실내복 착용이 인체 피부혈류량, 온열 심리 및 온열 생리 기능에 미치는 영향)

  • Baek, Yoon Jeong;Seo, Wonji;Kim, Hyung Chan;Lee, Joo-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.2
    • /
    • pp.342-353
    • /
    • 2020
  • The purpose of this study was to evaluate far-infrared clothing (FIR condition) with non-far-infrared clothing (Control condition) to assess the effects of FIR on thermo-physiological responses. Eight young healthy males (23.0±2.3 yr, 176.5±3.7 cm, and 69.0±4.3 kg) participated in this experimental trial, which consisted of a 20 min rest followed by a 40 min walk (4.0 km·hr-1) and a 20 min recovery at 20℃ with 50%RH. The results showed that finger skin blood flow and mean skin temperature were significantly higher for the FIR condition than the control during exercise and recovery (p<.001). Clothing microclimate temperature of the FIR condition was 0.5℃ higher on the back (p=.001) and 0.4℃ higher on the thigh (p=.015) during recovery. Clothing microclimate relative humidity of the FIR condition was 13% higher on the chest (p=.006) and 19% higher on the back (p<.001) during exercise than control. Subjects felt warmer and more comfortable in the FIR condition than in the control (p<.05). Perceived skin wettedness (%BSA) was less in the FIR condition than in the control (p=.001). These results indicate that ceramic-embedded clothing had significant effects on thermoregulatory responses for light activity in an indoor environment.