• Title/Summary/Keyword: MICRO

Search Result 16,722, Processing Time 0.056 seconds

Dry etching of polycarbonate using O2/SF6, O2/N2 and O2/CH4 plasmas (O2/SF6, O2/N2와 O2/CH4 플라즈마를 이용한 폴리카보네이트 건식 식각)

  • Joo, Y.W.;Park, Y.H.;Noh, H.S.;Kim, J.K.;Lee, S.H.;Cho, G.S.;Song, H.J.;Jeon, M.H.;Lee, J.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.1
    • /
    • pp.16-22
    • /
    • 2008
  • We studied plasma etching of polycarbonate in $O_2/SF_6$, $O_2/N_2$ and $O_2/CH_4$. A capacitively coupled plasma system was employed for the research. For patterning, we used a photolithography method with UV exposure after coating a photoresist on the polycarbonate. Main variables in the experiment were the mixing ratio of $O_2$ and other gases, and RF chuck power. Especially, we used only a mechanical pump for in order to operate the system. The chamber pressure was fixed at 100 mTorr. All of surface profilometry, atomic force microscopy and scanning electron microscopy were used for characterization of the etched polycarbonate samples. According to the results, $O_2/SF_6$ plasmas gave the higher etch rate of the polycarbonate than pure $O_2$ and $SF_6$ plasmas. For example, with maintaining 100W RF chuck power and 100 mTorr chamber pressure, 20 sccm $O_2$ plasma provided about $0.4{\mu}m$/min of polycarbonate etch rate and 20 sccm $SF_6$ produced only $0.2{\mu}m$/min. However, the mixed plasma of 60 % $O_2$ and 40 % $SF_6$ gas flow rate generated about $0.56{\mu}m$ with even low -DC bias induced compared to that of $O_2$. More addition of $SF_6$ to the mixture reduced etch of polycarbonate. The surface roughness of etched polycarbonate was roughed about 3 times worse measured by atomic force microscopy. However examination with scanning electron microscopy indicated that the surface was comparable to that of photoresist. Increase of RF chuck power raised -DC bias on the chuck and etch rate of polycarbonate almost linearly. The etch selectivity of polycarbonate to photoresist was about 1:1. The meaning of these results was that the simple capacitively coupled plasma system can be used to make a microstructure on polymer with $O_2/SF_6$ plasmas. This result can be applied to plasma processing of other polymers.

Low Dose Cisplatin as a Radiation Sensitizer in Management of Locally Advanced Scluamous Cell Carcinoma of the Uterine Cervix : Evaluation of Acute Toxicity and Early Response (국소 진행된 자궁경부암의 방사선치료와 저용량 cisplatin 항암요법 동시치료시 급성독성 밀 초기반응 평가)

  • Kim Hunjung;Cho Young Kap;Kim Chulsu;Kim Woo Chul;Lee Sukho;Loh J K
    • Radiation Oncology Journal
    • /
    • v.17 no.2
    • /
    • pp.113-119
    • /
    • 1999
  • Purpose : To evaluate possible acute toxicity and early response of concurrent radiation therapy and low dose daily cisplatin as a radiosensitizer in patients with locally advanced uterine cervical carcinomas. Materials and Method : From December 1996 to January 1999, 38 previously untreated Patients with locally advanced squamous cell carcinoma of the uterine cervix (from stage IIB to stage IIIB) were treated at Inha University Hospital. All patients underwent standard pretreatment staging Procedures after the initial evaluation by gynecologists and radiation oncologists. Sixteen Patients with huge cervical mass (>4 cm) were submitted to the group treated with concurrent radiation therapy and low dose daily cisplatin while the remainder was treated with radiation therapy alone. Radiation therapy consisted of 4500 cGy external beam irradiation to whole pelvis (midline block after 3000 cGy), 900$\~$1000 cGy boost to involved parametrium, and high dose-rate intracavitary brachytherapy (a total dose of 3000$\~$3500 cGy/500 cGy per fraction to point A, twice per week). In the group treated with low dose cisplatin concurrently, 10 mg of daily intravenous cisplatin was given from the 1st day of radiation therapy to the 20th day of radiation therapy. Acute toxicity was measured according to expanded common toxicity criteria of the NCI (C) Clinical Trials. Early response data were analyzed at minimum 4 weeks' follow-up after completion of the treatment protocol. Results: Hematolgic toxici쇼 was more prominent in patients treated with radiation therapy and cisplatin. Six of 16 patients (37.5$\~$) treated with radiation therapy and cisplatin and one of 22 patients (4.5$\~$) treated with radiation therapy alone experienced grade 3 leukopenia. In Fisher's exact test, there was statistically significant difference between two groups regarding leukopenia (P=0.030). There was no apparent difference in the frequency of gastrointestinal and genitourinary toxicity between two groups (P=0.066). Three of 16 patients (18.7$\~$) treated with radiation therapy and cisplatin and two of 22 patients (9.1$\~$) treated with radiation therapy alone experienced more than 5 kg weight loss during the treatment. There was no statistically significant difference on weight loss between two groups (P=0.63). Two patients on each group were not evaluable for the early response because of incomplete treatment. The complete response rate at four weeks' follow-up was 80$\~$(16/20) for the radiation therapy alone group and 78$\~$ (11/14) for the radiation therapy and cisplatin group. There was no statistically significant difference in early response between two treatment groups (P=0.126). Conclusion : This study led to the conclusion that the hematologic toxicity from the treatment with concurrent radiation therapy and low dose daily cisplatin seems to be more prominent than that from the treatment of radiation therapy alone. There was no grade 4 hematologic toxicity or mortality in both groups. The hematologic toxicity in both treatment groups seems to be well managable modically. Since the risk factors were not balanced between two treatment groups, the direct comparison of early response of both groups was not possible. However, preliminary results regarding early response for patients with bulky cervical tumor mass treated with radiation therapy and low dose daily cisplatin was encouraging. Longer follow-up is necessary to evaluate the survival data. A phase III study is needed to evaluate the efficacy of concurrent daily low dose cisplatin with radiation therapy in bulky cervical cancer.

  • PDF

A Study on the Expression of CD44s and CD44v6 in Non-Small Cell Lung Carcinomas (비소세포성 폐암종의 CD44s 및 CD44v6의 발현에 대한 연구 -CD44의 발현에 대한 연구-)

  • Chang, Woon-Ha;Oh, Tae-Yun;Kim, Jung-Tae
    • Journal of Chest Surgery
    • /
    • v.39 no.1 s.258
    • /
    • pp.1-11
    • /
    • 2006
  • Background: CD44 is a glycoprotein on the cell surface which is involved in the cell-to-cell and cell-to-matrix interaction. The standard form, CD44s and multiple isoforms are determined by alternative splicing of 10 exons. Recent studies have suggested that CD44 may help invasion and metastasis of various epithelial tumors as well as activation of Iymphocytes and monocytes. The expression pattern of CD44 can be different according to tumor types. The author studied the expression pattern of CD44s and one of its variants, CD44v6 in non-small cell lung carcinomas (NSCLC) to find their implications on clinicopathologic aspects, including the survival of the patients. Material and Method: A total of 89 primary NSCLSs (48 squamous cell carcinomas, 33 adenocarcinomas, and 8 undifferentiated large cell carcinomas) were retrieved during the years between 1985 to 1994. The immunohisto chemistry was done by using monoclonal antibodies and the CD44 expression for angiogenesis was evaluated by counting the number of tumor microvessels. Result: Seventy-one (79.8$\%$) and 64 (71 .9$\%$) among 89 NSCLSs revealed the expression of CD44s and CD44v6, respectively. The expression of CD44s was well correlated with that of CD44v6 (r=0.710, p < 0.0001). The expression of CD44s and CD44v6 was associated with the histopathologic type of the NSCLCs, and squamous cell carcinoma was the type that showed the highest expression of CD44s and CD44v6 (p < 0.0001). Microvessel count was the highest in adenocarcinomas (113.6$\pm$69.7 on 200-fold magnification and 54.8$\pm$41.1 on 400-fold magnification) and correlated with the tumor size of TNM system (r=0.217, p=0.043) and CD44s expression (r=0.218, p=0.040). In adenocarcinoma, the patients with higher CD44s expression survived shorter than those with lower CD44s expression (p=0.0194) but there was no statistical significance on multivariate analysis(p=0.3298). Conclusion: The expression of both CD44s and CD44v6 may be associated with the squamous differentiation in non-small cell lung carcinomas. The relationship of CD44s expression with micro-vessel density of the tumor suggests an involvement of CD44s in tumor angiogenesis, which in turn would help tumor growth.

Studies on the Organo-mercury Residues in Rice Grain -I. Mercury residues in rice seeds treated with organo-mercury fungicide- (수도(水稻)에 처리(處理)된 유기수은제(有機水銀劑)의 잔류성(殘留性)에 관(關)한 연구(硏究) -제1보(第1報) 침지용유기수은제(浸漬用有機水銀劑)로 처리(處理)된 수도종자중(水稻種子中)의 수은잔류량(水銀殘留量)에 관(關)하여-)

  • Lee, Dong-Suk
    • Applied Biological Chemistry
    • /
    • v.8
    • /
    • pp.87-93
    • /
    • 1967
  • 1) For the micro-analysis of mercury in plant materials, the method of Furutani was shown to be the simplest and most efficient way and the recovery of the assay was about 98%. 2) When the rice grain was soaked in 1/1000 diluted solution of organo-mercury fungicide for 8 hours at the end of March, the amounts of mercury residues in the brown rice and unhulled rice were 8.8 to $9.5\;{\mu}g/g$ seeds and 10.1 to $10.7\;{\mu}g/g$ seeds, respectively. 3) By washing the treated rice seeds with running water for three days, tile residual mercury concentration was reduced to 1/4 to 1/5; thus the mercury residues were 1.86 to $1.92\;{\mu}g/g$ for brown rice and 1.96 to $2.93\;{\mu}g/g$ for unhulled rice. 4) The residual mercury was present more in the unhulled rice than in the brown rice, either before or after washing of the treated seeds. 5) Among the different rice varieties, no difference was observed in mercury residues by seed treatment and washing.

  • PDF

Comparison of the Result of Radiation Alone and Radiation with Daily Low Dose Cisplatin in Management of Locally Advanced Cervical Cancer (국소적으로 진행된 자궁경부암에서 방사선 단독치료와 방사선 및 저용량 Cisplatin 항암화학요법 병용치료의 비교)

  • Kim Hun Jung;Kim Woo Chul;Lee Mee Jo;Kim Chul Su;Song Eun Seop;Loh John J K.
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.200-207
    • /
    • 2004
  • Purpose: An analysis was to compare the results of radiation alone with those of radiation with dally low dose cisplatin as a radiation sensitizer in locally advanced cervical cancer. Materials and Methods: A retrospective analysis of 59 patients diagnosed with locally advanced uterine cervix cancer between December 1996 and March 2001 was peformed. Thirty one patients received radiation alone and 28 patients received dally low dose cisplatin, as a radiation sensitizer, and radiation therapy. The median follow-up period was 34 months, ranging from 2.5 to 73 months. The radiation therapy consisted of 4500 cGy external beam irradiation to the whole pelvis (midline block after 3060 cGy), a 900$\~$l,000 cGy boost to the involved parametrium and high dose-rate intracavitary brachytherapy (a total dose of 3,000$\~$3,500 cGy/500 cGy per fraction to point A, twice per week). In the chemoradiation group, 10 mg of daily intravenous cisplatin was given daily from the 1st day of radiation therapy to the 20th day of radiation therapy. According to the FIGO classification, the patients were subdivided into 51 (86.4$\%$) and 8 (13.6$\%$) stages IIB and stage IIIB, respectively. Results: The overall 5 year survival rate was 65.65$\%$ and according to treatment modality were 56.75$\%$ and 73.42$\%$ in the radiation alone and chemoradiation groups, respectively (p=0.180). The 5 year disease-free survival rates were 49.39$\%$ and 63.34$\%$ in the radiation alone and chemoradiatoin groups, respectively (p=0.053), The 5 year locoregional control rates were 52.34$\%$ and 73.58$\%$ in the radiation alone and chemoradiation groups, respectively (p=0.013). The 5 year distant disease-free survival rates were 59.29$\%$ and 81.46$\%$ in the radiation alone and chemoradiation groups, respectively (p=0.477), Treatment related hematologic toxicity were prominent in the chemoradiation group. Leukopenia $\geq$grade) occurred in 3.2$\%$and 28.5$\%$ of the radiation alone and chemoradiation groups, respectively (p=0.02). There were no statistical differences in the incidences of vesical, rectal and small bowel complications between two groups. Conclusion: Radiation therapy with low dose cisplatin did not improve the rates of survival and response rates, but did improve the rate of disease free survival and locoregional control rates In locally advanced cervical cancer. The incidence of bone marrow suppression was higher in the chemoradiation group.

SURFACE ROUGHNESS OF COMPOSITE RESIN ACCORDING TO FINISHING METHODS (복합레진 표면의 연마방법에 따른 표면조도)

  • Min, Jeong-Bum;Cho, Kong-Chul;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.138-150
    • /
    • 2007
  • The purpose of this study was to evaluate the difference of surface roughness of composite resin according to composite resin type, polishing methods, and use of resin sealant. Two hundred rectangular specimens, sized $8{\times}3{\times}2mm$, were made of Micro-new (Bisco, Inc., Schaumburg, IL, U.S.A) and Filtek Supreme (3M ESPE Dental Products, St. Paul, MN, U.S.A.), and divided into two groups; Micronew-M group, Filtek Supreme-S group. Specimens for each composite group were subdivided into five groups by finishing and polishing instruments used; M1 & S1(polyester strip), M2 & S2 (Sof-Lex disc), M3 & S3 (Enhance disc and polishing paste), M4 & S4(Astropol) and M5 & S5 (finishing bur), Polished groups were added letter B after the application of resin surface sealant (Biscover), eg, M1B and S1B. After specimens were stored with distilled water for 24hr, average surface roughness (Ra) was taken using a surface roughness tester. Representative specimens of each group were examined by FE-SEM (S-4700: Hitachi High Technologies Co., Tokyo, Japan). The data were analysed using paired t-test, ANOVA and Duncan's tests at the 0.05 probability level. The results of this study were as follows ; 1. The lowest Ra was achieved in all groups using polyester strip and the highest Ra was achieved in M5, S5 and M5B groups using finishing bur. On FE-SEM, M1 and S1 groups provided the smoothest surfaces, M5 and S5 groups were presented the roughest surfaces and voids by debonding of filler on the polished specimens. 2. There was no significant difference in Ra between Micronew and Filtek Supreme before the application of resin sealant, but Micronew was smoother than Filek Supreme after the application of resin sealant. 3. There was significant corelation between Ra of type of composite resin and polishing methods before the application of resin sealant (p=0.000), but no significant interaction between them after the application of resin sealant. On FE-SEM, most of composite resin surfaces were smooth after the application of resin sealant on the polished specimens. 4. Compared with before and after the application of resin sealant in group treated in the same composite and polishing methods, Ra of M4B and M5B was statistically lower than that of M4 and M5, and S5B was lower than that of S5, respectively (p<0.05). In conclusion, surface roughness by polishing instruments was different according to type of composite resin. Overall, polyester strip produced the smoothest surface, but finishing bur produced the roughest surface. Application of resin sealant provided the smooth surfaces in specimens polished with Enhance, Astropol and finishing bur, but not provided them in specimens polished with Sof-Lex disc.

The micro-tensile bond strength of two-step self-etch adhesive to ground enamel with and without prior acid-etching (산부식 전처리에 따른 2단계 자가부식 접착제의 연마 법랑질에 대한 미세인장결합강도)

  • Kim, You-Lee;Kim, Jee-Hwan;Shim, June-Sung;Kim, Kwang-Mahn;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.148-156
    • /
    • 2008
  • Statement of problems: Self-etch adhesives exhibit some clinical benefits such as ease of manipulation and reduced technique-sensitivity. Nevertheless, some concern remains regarding the bonding effectiveness of self-etch adhesives to enamel, in particular when so-called 'mild' self-etch adhesives are employed. This study compared the microtensile bond strengths to ground enamel of the two-step self-etch adhesive Clearfil SE Bond (Kuraray) to the three-step etch-and- rinse adhesive Scotchbond Multi-Purpose (3M ESPE) and the one-step self-etch adhesive iBond (Heraeus Kulzer). Purpose: The purpose of this study was to determine the effect of a preceding phosphoric acid conditioning step on the bonding effectiveness of a two-step self-etch adhesive to ground enamel. Material and methods: The two-step self-etch adhesive Clearfil SE Bond non-etch group, Clearfil SE Bond etch group with prior 35% phosphoric acid etching, and the one-step self-etch adhesive iBond group were used as experimental groups. The three-step etch-and-rinse adhesive Scotchbond Multi-Purpose was used as a control group. The facial surfaces of bovine incisors were divided in four equal parts cruciformly, and randomly distributed into each group. The facial surface of each incisor was ground with 800-grit silicon carbide paper. Each adhesive group was applied according to the manufacturer's instructions to ground enamel, after which the surface was built up using Light-Core (Bisco). After storage in distilled water at $37^{\circ}C$ for 1 week, the restored teeth were sectioned into enamel beams approximately 0.8*0.8mm in cross section using a low speed precision diamond saw (TOPMET Metsaw-LS). After storage in distilled water at $37^{\circ}C$ for 1 month, 3 months, microtensile bond strength evaluations were performed using microspecimens. The microtensile bond strength (MPa) was derived by dividing the imposed force (N) at time of fracture by the bond area ($mm^2$). The mode of failure at the interface was determined with a microscope (Microscope-B nocular, Nikon). The data of microtensile bond strength were statistically analyzed using a one-way ANOVA, followed by Least Significant Difference Post Hoc Test at a significance level of 5%. Results: The mean microtensile bond strength after 1 month of storage showed no statistically significant difference between all adhesive groups (P>0.05). After 3 months of storage, adhesion to ground enamel of iBond was not significantly different from Clearfil SE Bond etch (P>>0.05), while Clearfil SE Bond non-etch and Scotchbond Multi-Purpose demonstrated significantly lower bond strengths (P<0.05), with no significant differences between the two adhesives. Conclusion: In this study the microtensile bond strength to ground enamel of two-step self-etch adhesive Clearfil SE Bond was not significantly different from three-step etch-and-rinse adhesive Scotchbond Multi-Purpose, and prior etching with 35% phosphoric acid significantly increased the bonding effectiveness of Clearfil SE Bond to enamel at 3 months.

The Effect of Franchisor's On-going Support Services on Franchisee's Relationship Quality and Business Performance in the Foodservice Industry (외식 프랜차이즈 가맹본부의 사후 지원서비스가 가맹점의 관계품질과 경영성과에 미치는 영향)

  • Lee, Jae-Han;Lee, Yong-Ki;Han, Kyu-Chul
    • Journal of Distribution Research
    • /
    • v.15 no.3
    • /
    • pp.1-34
    • /
    • 2010
  • Introduction The purpose of this research is to develop overall model which involves the effect of ongoing support services by franchisor on franchisee's relationship quality(trust, satisfaction, and commitment) and business performance(financial and non-financial performance), and to investigate the relationships among trust, satisfaction, commitment, financial and non-financial performance. This study also suggests franchise business or franchise system should be based on long-term orientation between franchisor and franchisee rather than short-term orientation, or transactional relationship, and proposes the most effective way of providing on-going support services by franchisor with franchisee thru symbiotic relationship among franchisor and franchisee Research Model and Hypothesis The research model as Figure 1 shows the variables on-going support services which affect the relationship quality between franchisor and franchisee such as trust, satisfaction, and commitment, and also analyze the effects of relationship quality on business performance including financial and non-financial performance We established 12 hypotheses to test as follows; Relationship between on-going support services and trust H1: On-going support services factors (product category & price, logistics service, promotion, information providing & problem solving capability, supervisor's support, and education & training support) have positive effect on franchisee's trust. Relationship between on-going support services and satisfaction H2: On-going support services factors (product category & price, logistics service, promotion, information providing & problem solving capability, supervisor's support, and education & training support) have positive effect on franchisee's satisfaction. Relationship between on-going support services and commitment H3: On-going support services factors (product category & price, logistics service, promotion, information providing & problem solving capability, supervisor's support, and education & training support) have positive effect on franchisee's commitment. Relationship among relationship quality: trust, satisfaction, and commitment H4: Franchisee's trust has positive effect on franchisee's satisfaction. H5: Franchisee's trust has positive effect on franchisee's commitment. H6: Franchisee's satisfaction has positive effect on franchisee's commitment. Relationship between relationship quality and business performance H7: Franchisee's trust has positive effect on franchisee's financial performance. H8: Franchisee's trust has positive effect on franchisee's non-financial performance. H9: Franchisee's satisfaction has positive effect on franchisee's financial performance. H10: Franchisee's satisfaction has positive effect on franchisee's non-financial performance. H11: Franchisee's commitment has positive effect on franchisee's financial performance. H12: Franchisee's commitment has positive effect on franchisee's non-financial performance. Method The on-going support services were defined as an organized system of continuous supporting services by franchisor for the purpose of satisfying the expectation of franchisee based on long-term orientation and classified into six constructs such as product category & price, logistics service, promotion, providing information & problem solving capability, supervisor's support, and education & training support. The six constructs were measured agreement using a 7-point Likert-type scale (1 = strongly disagree to 7 = strongly agree)as follows. The product category & price was measured by four items: menu variety, price of food material provided by franchisor, and support for developing new menu. The logistics service was measured by six items: distribution system of franchisor, return policy for provided food materials, timeliness, inventory control level of franchisor, accuracy of order, and flexibility of emergency order. The promotion was measured by five items: differentiated promotion activities, brand image of franchisor, promotion effect such as customer increase, long-term plan of promotion, and micro-marketing concept in promotion. The providing information & problem solving capability was measured by information providing of new products, information of competitors, information of cost reduction, and efforts for solving problems in franchisee's operations. The supervisor's support was measured by supervisor operations, frequency of visiting franchisee, support by data analysis, processing the suggestions by franchisee, diagnosis and solutions for the franchisee's operations, and support for increasing sales in franchisee. Finally, the of education & training support was measured by recipe training by specialist, service training for store people, systemized training program, and tax & human resources support services. Analysis and results The data were analyzed using Amos. Figure 2 and Table 1 present the result of the structural equation model. Implications The results of this research are as follows: Firstly, the factors of product category, information providing and problem solving capacity influence only franchisee's satisfaction and commitment. Secondly, logistic services and supervising factors influence only trust and satisfaction. Thirdly, continuing education and training factors influence only franchisee's trust and commitment. Fourthly, sales promotion factor influences all the relationship quality representing trust, satisfaction, and commitment. Fifthly, regarding relationship among relationship quality, trust positively influences satisfaction, however, does not directly influence commitment, but satisfaction positively affects commitment. Therefore, satisfaction plays a mediating role between trust and commitment. Sixthly, trust positively influence only financial performance, and satisfaction and commitment influence positively both financial and non-financial performance.

  • PDF

The Innovation Ecosystem and Implications of the Netherlands. (네덜란드의 혁신클러스터정책과 시사점)

  • Kim, Young-woo
    • Journal of Venture Innovation
    • /
    • v.5 no.1
    • /
    • pp.107-127
    • /
    • 2022
  • Global challenges such as the corona pandemic, climate change and the war-on-tech ensure that the demand who the technologies of the future develops and monitors prominently for will be on the agenda. Development of, and applications in, agrifood, biotech, high-tech, medtech, quantum, AI and photonics are the basis of the future earning capacity of the Netherlands and contribute to solving societal challenges, close to home and worldwide. To be like the Netherlands and Europe a strategic position in the to obtain knowledge and innovation chain, and with it our autonomy in relation to from China and the United States insurance, clear choices are needed. Brainport Eindhoven: Building on Philips' knowledge base, there is create an innovative ecosystem where more than 7,000 companies in the High-tech Systems & Materials (HTSM) collaborate on new technologies, future earning potential and international value chains. Nearly 20,000 private R&D employees work in 5 regional high-end campuses and for companies such as ASML, NXP, DAF, Prodrive Technologies, Lightyear and many others. Brainport Eindhoven has a internationally leading position in the field of system engineering, semicon, micro and nanoelectronics, AI, integrated photonics and additive manufacturing. What is being developed in Brainport leads to the growth of the manufacturing industry far beyond the region thanks to chain cooperation between large companies and SMEs. South-Holland: The South Holland ecosystem includes companies as KPN, Shell, DSM and Janssen Pharmaceutical, large and innovative SMEs and leading educational and knowledge institutions that have more than Invest €3.3 billion in R&D. Bearing Cores are formed by the top campuses of Leiden and Delft, good for more than 40,000 innovative jobs, the port-industrial complex (logistics & energy), the manufacturing industry cluster on maritime and aerospace and the horticultural cluster in the Westland. South Holland trains thematically key technologies such as biotech, quantum technology and AI. Twente: The green, technological top region of Twente has a long tradition of collaboration in triple helix bandage. Technological innovations from Twente offer worldwide solutions for the large social issues. Work is in progress to key technologies such as AI, photonics, robotics and nanotechnology. New technology is applied in sectors such as medtech, the manufacturing industry, agriculture and circular value chains, such as textiles and construction. Being for Twente start-ups and SMEs of great importance to the jobs of tomorrow. Connect these companies technology from Twente with knowledge regions and OEMs, at home and abroad. Wageningen in FoodValley: Wageningen Campus is a global agri-food magnet for startups and corporates by the national accelerator StartLife and student incubator StartHub. FoodvalleyNL also connects with an ambitious 2030 programme, the versatile ecosystem regional, national and international - including through the WEF European food innovation hub. The campus offers guests and the 3,000 private R&D put in an interesting programming science, innovation and social dialogue around the challenges in agro production, food processing, biobased/circular, climate and biodiversity. The Netherlands succeeded in industrializing in logistics countries, but it is striving for sustainable growth by creating an innovative ecosystem through a regional industry-academic research model. In particular, the Brainport Cluster, centered on the high-tech industry, pursues regional innovation and is opening a new horizon for existing industry-academic models. Brainport is a state-of-the-art forward base that leads the innovation ecosystem of Dutch manufacturing. The history of ports in the Netherlands is transforming from a logistics-oriented port symbolized by Rotterdam into a "port of digital knowledge" centered on Brainport. On the basis of this, it can be seen that the industry-academic cluster model linking the central government's vision to create an innovative ecosystem and the specialized industry in the region serves as the biggest stepping stone. The Netherlands' innovation policy is expected to be more faithful to its role as Europe's "digital gateway" through regional development centered on the innovation cluster ecosystem and investment in job creation and new industries.

An Anatomical Study of the Posterior Tympanum (한국인 중이강후벽에 관한 형태해부학적 고찰)

  • 양오규;윤강묵;심상열;김영명
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.17.2-19
    • /
    • 1982
  • The sinus tympani is subject to great variability in the size, shape and posterior extent. A heavy compact bony zone, especially in the posterior portion and the narrow space between the facial nerve and posterior semicircular canal are the limitation of surgical approach. The facial recess should be opened, creating a wide connection between the mesotympanum and mastoid in the Intact canal wall tympanoplasty with mastoidectomy. The surgically created limits of the facial recess are the facial nerve medially, the chorda tympani laterally and the bone adjacent to the incus superiorly. Using adult Korean's thirty-five temporal bones, the authors measured the osteologic reslationship in the posterior tympanum, especially sinus tympani and facial recess. The result was as followed. 1. The average distance from the anterior end of the pyramidal eminence. 1) to the edge of the sinus tympani directly posterior was 2.54(1.05-5.40)mm. 2) to the maximum posterior extent was 3.22(1.25-7.45)mm. 3) to the maximum cephaled extent was 0.67 (0.40-1.75)mm. 2. The boundary of the sinus tympani was 82.9% from the lower margin oval window to the upper margin round window niche. 3. The deepest part of the sinus tympani was 62.9% in the mid portion, between the ponticulus and subiculum. 4. The oblique dimension from the fossa incudis above to the hypotympanum below was 8.13(7.90-9.55)mm. 5. The transverse dimensions midway between the oval window above and round window below was 3.00(2.85-3.45)mm. 6. The transverse dimension at the level of the fossa incudis was 1.81(1.40-2.15)mm. 7. The facial nerve dehiscence was 14.3%. 8. Anterior-posterior diameter of the footplate was 2.98(2.85-3.05) mm. 9. The average distance from the footplate. 1) to the cochleariform process was 1.42(1.35-1.55) mm. 2) to the round window niche was 1.85(1.45-2.10) mm.

  • PDF