• Title/Summary/Keyword: MI cable

Search Result 35, Processing Time 0.034 seconds

Development of HVDC 500kV PPLP MI cable systems in Korea (HVDC 500kV PPLP MI 케이블시스템 개발)

  • Lee, Soo-bong;Cho, Dong-sik;Lee, Tae-ho;Kim, Sung-yun;Lee, Su-kil;Jeon, Seung-ik
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1202-1203
    • /
    • 2015
  • This paper describes the development of HVDC ${\pm}500kV$ polypropylene laminated paper (PPLP) mass-impregnated (MI) type cable system for HVDC transmission lines. As you know, mass-impregnated type cable generally has only insulating layer with the Kraft paper impregnated with a high-viscosity insulating compound. But polypropylene laminated paper is made of a layer of extruded polypropylene (PP) film sandwiched between two layers of Kraft paper. Thanks to PP film and its combination with Kraft paper, PPLP has higher AC, Impulse (Imp.) and DC breakdown (BD) strengths as well as lower dielectric loss than conventional Kraft paper insulation. In addition, Kraft MI cable has a limitation for the maximum conductor temperature as $55^{\circ}C$ But this PPLP MI cable has higher maximum conductor temperature than that of Kraft MI cable due to advantage of oil drainage characteristics. It is the most economic type of cable for HVDC transmission. Also HVDC ${\pm}500kV$ PPLP MI cable system was developed including land joints and outdoor-terminations. In order to prove the mechanical and electrical performances, the type test was carried out according to CIGRE recommendations. A full scale cable system has been tested successfully. And additional load cycle and polarity reversal tests on the cable system showed a higher performance compared with a similar mass impregnated paper cable.

  • PDF

Nonlinear Behaviors of Cable Spoke Wheel Roof Systems (케이블 스포크 휠 지붕 시스템의 비선형 거동)

  • Park, Kang-Geun;Lee, Mi-Hyang;Park, Mi-Jin
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.1
    • /
    • pp.31-40
    • /
    • 2017
  • The objective of this study is to analysis the mechanical characteristics and nonlinear behaviors on the geometric nonlinear behavior of a cable spoke wheel roof system for long span lightweight roof structures. The weight of a cable spoke wheel roof dramatically can reduce and the cable roof system can easily make the required rigidity and shape by the sag ratio and pretension forces. Determining the pretension and initial sag of cable roof system is essential in a design process and the shape of roof is changed by pretension. The nonlinear behavior of flexible cable system has greatly an affect on the sag and pretension. This paper will be carried out analyzing and comparing the tensile forces and deflection of a cable spoke wheel system for the large span retractable roof, and analyzed to deflections and tensile forces by the post height of center hub. The double arrangement of a spoke wheel system with reverse curvature works more effectively as a load bearing system, the pretension can easily increase the structural stiffness. The cable truss system can carry vertical load in up and downward direction, and act effectively as load bearing elements.

Trend of Industry and Standard related to Offshore Cable for Offshore Wind Farm (해상풍력용 해저케이블 산업 및 기술기준 동향)

  • Kim, Kyung-Hwa;Song, Yong-Un;Kim, Mi-Young;Kim, Mann-Eung
    • Journal of Wind Energy
    • /
    • v.3 no.2
    • /
    • pp.11-17
    • /
    • 2012
  • An offshore(submarine) cable has been used for more than a century, however it has been used mainly for communication or power supply to near-shore island. Therefore, offshore cable has not been got more attention than other types of cable and the related standards have also not been established well. However wind farms have been shifting from land to offshore because of better wind condition. Consequently, it has been pushing up demand for offshore cable. Hence, this paper introduces the trend of offshore cable industry and related standards or recommendations only focusing on offshore wind farm. In details, the installed offshore cables in offshore wind farms, the main offshore cable makers and up to date technologies are covered. In addition, the related standards or recommendations are also analyzed and compared each other.

The Analysis of HVDC Cable Oil Swelling Characteristics on the Silicone Rubber (HVDC 절연유 중에서 Silicone Rubber의 팽윤특성 분석)

  • Lee, T.H.;Kim, N.Y.;Kim, J.N.;Jeon, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.623-624
    • /
    • 2007
  • This work examines the effects of swelling MI type HVDC cable oil on the semiconductive silicone rubber and silicone rubber as used in accessories for application on outdoor termination (EBA) slip on sleeve. The behavior of volume resistivity is monitored as a function of the amount of cable oil diffused into the material. Resistivities of semiconductive silicone samples up to the typical insulator range (${\sim}10^{10}{\Omega}-cm$) are observed as a consequence of swelling due to the presence of the diffused oil. The measured volume resistivities of the oil-impregnated semiconductive silicone rubber are compared to desired value as function of stress relief cone.

  • PDF

Mechanical and Electrical Performance of 180kV HVDC Submarine Cable System (180kV HVDC 해저케이블 기계적/전기적 특성 평가)

  • Kim, N.Y.;Lee, T.H.;Lee, S.J.;Ji, B.K.;Kim, J.N.;Jeon, S.I.;Yun, H.S.;Joung, S.K.;Kang, C.H.;An, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.616-618
    • /
    • 2007
  • This paper describes the mechanical and electrical test on HVDC submarine cable, Flexible Repair Joint and termination for 180kV. This HVDC submarine cable was manufactured using LS cable's unique skill and would be applied the HVDC submarine cable system in korea. The performance test consist of mechanical test and electrical test. The tensile bending test and tensile test was done as the mechanical test and Electrical test is DC voltage and Impulse test. The tensile bending test carried out 6 times(double of specified times) for maximum reliability. The DC test voltage is $\pm$400kV/1hr. We estimate the lower limit of DC breakdown voltage is 600kV. The impulse test voltage is $\pm$800kV/10shots. The type of developed cables is the MI type. Its insulation consist of paper tapes impregnated with a high viscosity oil. The development of new HVDC cable is available for HVDC underground or submarine power transmission. The developed HVDC cable, FRJ and termination have passed the mechanical and electrical test successfully and showed excellent performance.

  • PDF

Optimization of Plain Jacked Vessel Design in Adhesive Production Process Using Computational Fluid Dynamics (Computational Fluid Dynamics를 활용한 점/접착 생산 공정 내 Jacketed Vessel 설계 최적화)

  • Joo, Chonghyo;Park, Hyundo;Cho, Hyungtae;Kim, Junghwan
    • Applied Chemistry for Engineering
    • /
    • v.31 no.6
    • /
    • pp.596-602
    • /
    • 2020
  • Blending process of adhesive production has a cooling process to cool down the temperature of the solution which was heated up to 76 ℃ with a mineral insulated (MI) cable by 30 ℃ at room temperature. Using a MI cable in the adhesive production process makes the production inefficient because it takes about 10 h for the cooling process. If a jacketed vessel is used instead of the MI cable, it would shorten the cooling downtime without any additional cooling system by using cold water. However, there are various types of jacketed vessels, and thus the most suitable type should be found before set up. In this study, we designed the optimized jacketed vessel for the adhesive production process by calculating the cooling downtime, which impacts production efficiency, as a function of the jacket types using computational fluid dynamics. As a result, the cooling performance of the plain jacket was 32.7% superior to that of the half-pipe coil jacket with the same height. In addition, the plain jacket with 60% spiral baffle reduced the cooling downtime and operating time by 80.4% and 25.1%, respectively.

Optimal sensor placement for cable force monitoring using spatial correlation analysis and bond energy algorithm

  • Li, Shunlong;Dong, Jialin;Lu, Wei;Li, Hui;Xu, Wencheng;Jin, Yao
    • Smart Structures and Systems
    • /
    • v.20 no.6
    • /
    • pp.769-780
    • /
    • 2017
  • Cable force monitoring is an essential and critical part of the safety evaluation of cable-supported bridges. A reasonable cable force monitoring scheme, particularly, sensor placement related to accurate safety assessment and budget cost-saving becomes a major concern of bridge administrative authorities. This paper presents optimal sensor placement for cable force monitoring by selecting representative sensor positions, which consider the spatial correlativeness existing in the cable group. The limited sensors would be utilized for maximizing useful information from the monitored bridges. The maximum information coefficient (MIC), mutual information (MI) based kernel density estimation, as well as Pearson coefficients, were all employed to detect potential spatial correlation in the cable group. Compared with the Pearson coefficient and MIC, the mutual information is more suitable for identifying the association existing in cable group and thus, is selected to describe the spatial relevance in this study. Then, the bond energy algorithm, which collects clusters based on the relationship of surrounding elements, is used for the optimal placement of cable sensors. Several optimal placement strategies are discussed with different correlation thresholds for the cable group of Nanjing No.3 Yangtze River Bridge, verifying the effectiveness of the proposed method.

Evaluation of Effects of Impurities on Insulating Properties of Polymeric Insulator in Power Distribution Cable (배전케이블내 고분자 절연체의 절연성능에 미치는 불순물의 영향평가)

  • Cho, Young-Shin;Shim, Mi-Ja;Kim, Sang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1402-1404
    • /
    • 1997
  • To evaluate the effects of impurities on insulating properties of polymeric insulator in high electric power distribution cable, OIT and OMT were measured. By using Eyring plot, the thermodynamic parameters of ${\Delta}H$ and ${\Delta}S$ could be obtained.

  • PDF

Technology of Electrical Barrier Material (전기차단성 소재 기술)

  • Shin, Eun-Mi
    • Elastomers and Composites
    • /
    • v.46 no.1
    • /
    • pp.22-28
    • /
    • 2011
  • Various materials are used as electrical barrier materials, such as glass, insulating oil, gas, paper and polymer. These materials shut off electricity from conductor as a barrier and separate as well as support conductor from outside environment while using electrical equipment. Polymers are generally used for cable insulation material. Recently environmental regulation are reinforced and eco-friendly materials are in trend.

Development of Sealing Technology for Instrumentation Feedthrough of High Pressure Vessel (고압용기의 계장선 통과부위 밀봉기술 개발)

  • Jeong, H.Y.;Hong, J.T.;Ahn, S.H.;Joung, C.Y.;Lee, J.M.;Lee, C.Y.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.2
    • /
    • pp.137-143
    • /
    • 2011
  • Fuel Test Loop(FTL) is a facility which could conduct a fuel irradiation test at HANARO(High-flux Advanced Neutron Application Reactor). FTL simulates commercial NPP's operating conditions such as the pressure, temperature and neutron flux levels to conduct the irradiation and thermo-hydraulic tests. The In-Pile Test Section(IPS) installed in HANARO FTL is designed as a pressure vessel design conditions of $350^{\circ}C$, 17.5MPa. The instrumentation MI-cables for thermocouples, SPND and LVDT are passed through the sealing plug, which is in the pressure boundary region and is a part of instrumentation feedthrough of MI-cable. In this study, the brazing method and performance test results are introduced to the sealing plug with BNi-2 filler metal, which is selected with consideration of the compatibility for the coolant. The performance was verified through the insulation resistance test, hydrostatic test, and helium leak test.