• 제목/요약/키워드: MGRE (multi-gradient-recalled echo)

검색결과 2건 처리시간 0.016초

간 전이환자에서 최적의 펄스시퀀스에 따른 SPIO 특이성 조영제의 국소병변검출: Case review (Focal Lesion Detection of SPIO-specific agent Compared with Optimized Pulse Sequences in the Hepatic Metastases: Case Review)

  • 구은회
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.57-61
    • /
    • 2012
  • To compare the accuracy of breath-hold magnetic resonance imaging sequences to establish the most effective superparamagnetic iron oxide-enhanced sequence for detection of hepatic metastases. A total of 100 patients(50men and 50women, mean age: 60years) with liver disease(including malignant and benign liver lesions) were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) with 8Ch body coil. Pulse sequence for MR imaging decided to the FS-T2-FSE-RT(TR/TE/Thick./Freq./Phase=12857ms/100ms/7mm/512/384), MGRE(TR/TE/Thick./Freq./Phase=100ms/9.7ms/7mm/384/288), in-out of phase echo(TR/$TE_1$, $TE_2$/Thick./Freq./Phase=140ms/2.4, 5.8ms/7mm/352/300), Images obtained before the injection of SPIO. Six sequences were optimized for lesion detection: FS-T2-FSE-RT, multigradient recalled echo data image(MGRE), T2-weighted MGRE with an 9.7msec echo time. Images were reviewed independently by five blinded observers. The accuracy of each sequence was measured by using picture archiving communication system analysis. All results were correlated with findings at multidectator computed tomography examination. Differences between the mean results of the six observers were measured by using paired student t-test analysis. Postcontrast T2-weighted MGRE sequences were the most accurate and were significantly superior to postcontrast FS-T2-FSE-RT, T2-weighted MGRE, in-out of phase MR sequences(p < .05). For all lesions that were malignant or smaller than 1 cm, respectively, contrast to noise ratio of pre and postcontrast sequences were -1and -0.3 for T2-weighted FSE, 0.53 and 4.5 in-out of phase, 7, 7.08, 5.08, 3.32, 1.7, 1.16, 0.79, 0.68 for GRE with 2.9, 7.5, 12.1, 16.6, 21.2, 25.8, 30.4, 35.0 TE values. Breath-hold various TE precontrast sequences offer improvement in sensitivity compared with fixed multigradient recalled echo sequences alone.

  • PDF

간 병변 특이성 조영제 자기공명영상에 대한 연구: Ferucarbotran과 Gd-EOB-DTPA 조영제의 비교 (A Study on Usefulness of Specific Agents with Liver Disease at MRI Imaging: Comparison with Ferucarbotran and Gd-EOB-DTPA Contrast Agents)

  • 이재승;구은회;박철수;이선엽;최용석
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.235-243
    • /
    • 2009
  • 다양한 간 질환에 Ferucarbotran (SPIO)과 Gd-EOB-DTPA (Primovist) 조영제를 사용하여 자기공명영상 상에서 비교하여 간 질환의 특성 및 검출 과 그 질환에 따른 조영제 흡수관계를 알아보고자 한다. 실험대상은 국소 간 병변을 가진 50명의 환자 중 남자 25명, 여자 25명으로 평균나이는 50세이었다. 사용된 장비와 코일은 3.0T (General Electric Medical System, Excite HD) 자기공명영상장치와 8채널 채부코일이었다. 질환과 조영제 흡수관계를 비교하기 위하여 사용된 펄스 시퀀스는 Liver aquisition with volume acceleration (LAVA)와 Multi-Gradient rapid Echo (MGRE)이었다. 모든 검사기법은 일정한 데이터를 획득하기 위하여 Ferucarbotran (SPIO) 및 Gd-EOB-DTPA (Primovist) 조영제를 주입 전 후에 같은 위치를 선정하여 검사를 시행했다(p<0.05). 검사 결과는 Ferucarbotran와 Gd-EOB-DTPA의 대조도대 잡음비는 간세포암(HCC, 16 cases)이 $3.08{\pm}0.12$$7.00{\pm}0.27$이었다. 과다형성결절(Hyperplastic Nodule, 7 cases) 질환은 $3.62{\pm}0.13$, $2.60{\pm}0.23$, 전이(Metastasis, 13 cases)는 $1.70{\pm}0.09$, $2.60{\pm}0.23$, 초점성 결절성 과증식(Focal Nodular Hyperplasia, 6 cases)질환은 $2.12{\pm}0.28$, $5.86{\pm}0.28$, 농양(Abscess, 8 cases)은 $4.45{\pm}0.28$, $1.73{\pm}0.02$이었다. 또한, 각 질환에 대한 진단적 수행을 위해 ANOVA 검증을 하였다(p<0.05). 결론적으로, 두 조영제 효과로 2개 검사기법 모두가 간질환의 특성 및 검출과 그 질환에 따른 조영제 특성을 잘 보여주었다.

  • PDF