• Title/Summary/Keyword: MF Membrane

Search Result 184, Processing Time 0.018 seconds

Effects of Membrane Filter and Sucrose Concentrations on the Growth of Balloon Flower (Platycodon grandiflorum A. DC.) Plantlets In Vitro (Membrane Filter와 Sucrose 농도가 도라지(Platycodon grandiflorum A. DC.) 기내 배양묘의 생장에 미치는 영향)

  • Choi, So-Ra;Kim, Myung-Jun;Eun, Jong-Seon;Ahn, Min-Sil;Lim, Hoi-Chun;Ryu, Jeong;You, Dong-Hyun
    • Journal of Plant Biotechnology
    • /
    • v.31 no.3
    • /
    • pp.209-217
    • /
    • 2004
  • The shoots of balloon flower (Platycodon grandiflorum A. DC.) in vitro germinated from seeds were cultured on MS basal medium containing 0.1 mg/L NAA under the various sucrose concentrations and with/without membrane filter (MF) on the lid of vessel. The growth responses were checked to obtain healthy plantlets. The $CO_2$ and $C_2$H$_4$ concentration in vessel without MF were higher than those with MF. The $CO_2$ concentration without MF was increased as days in culture went by whereas the $C_2$H$_4$ concentration was decreased. The plant growth with MF and high sucrose concentration was good. Fresh and dry weight of plantlets cultured in sucrose 4.5% with MF were higher than those in no sucrose without MF. Also the content of chlorophyll of plantlets cultured with MF was high and the content of sugar was shown a similar results and a remarkable difference between MF treatments, especially. Stomata cultured with MF was closer than that without MF and mesophyll of leaf were more developed with MF or in high sucrose concentration. When the plantlets were transplanted in the pot at 25$\pm$2$^{\circ}C$, 75% relative humidity and low PPFD (photosynthetic photon flux density), the percentage of survival after 13 days without MF was 0% but it was 100% with MF regardless of sucrose concentrations.

Effective Water Treatment Process by Hollow Fiber MF Membranes; VAS(Vibrating & Stripping by Air ) Process (에너지절약형 VSA MF Membrane 수처리 시스템)

  • 김정학
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.93-116
    • /
    • 1999
  • MF membrane element was specially designed for water purification and VSA process which can solve the fouling problem. Especially VSA process is developed for the SK Chemicals' asymmetric microfiltration hollow fiber membranes. In case of outside-to-in filtration process, MF membrane element showed the excellent flux stability caused by cleaning ability of VSA process . Simultaneous back-washing with VSA consideratbly enhances cleaning efficiency. From the result the possibility of the replacement of chemical coagulation and sand filtration process with newly developed VSA process was revealed.

  • PDF

Preparation of PVdF Composite Nanofiber Membrane by Using Manganese-Iron Oxide and Characterization of its Arsenic Removal (망간-철 산화물을 이용한 PVdF 나노섬유복합막의 제조 및 비소 제거 특성 평가)

  • Yun, Jaehan;Jang, Wongi;Park, Yeji;Lee, Junghun;Byun, Hongsik
    • Membrane Journal
    • /
    • v.26 no.2
    • /
    • pp.116-125
    • /
    • 2016
  • This study described a synthesis of MF having a arsenic removal characteristics and the fundamental research was performed about the simultaneous removal system of both As(III) and As(V) ions with the composite nanofiber membrane (PMF) based on PVdF and MF materials for the water-treatment application. From the TEM analysis, the shape and structure of MF materials was investigated. The mechanical strength, pore-size, contact angle and water-flux analysis for the PMF was performed to investigate the possibility of utilizing as a water treatment membrane. From these results, the PMF11 showed the highest value of mechanical strength ($232.7kgf/cm^2$) and the pore-diameter of composite membrane was reduced by introducing the MF materials. In particular, their pore diameter decreased with an increase of iron oxide composition ratio. The water flux value of PMF was improved about 10 to 60% compared with that of neat PVdF nanofiber membranes. From the arsenic removal characterization of prepared MF materials and PMF, it was shown the simultaneous removal characteristics of both As(III) and (V) ions, and the MF01, in particular, showed the highest adsorption-removal rate of 93% As(III) and 68% As(V), respectively. From these results, prepared MF materials and PMF have shown a great potential to be utilized for the fundamental study to improve the functionality of water treatment membrane.

Preparation of Higher Reinforced PVDF Hollow Fiber Microfiltration Membrane (고강도 PVDF 중공사 정밀여과막 제조 특성)

  • Choi, R.S.;Park, H.H.
    • Membrane Journal
    • /
    • v.20 no.4
    • /
    • pp.320-325
    • /
    • 2010
  • This paper was carried out to study the preparation condition and the permeation flux of reinforced poly(vinylidene fluoride) (PVDF) hollow fiber microfiltration (MF) membrane with the solvent, additive, second miscible polymer, and preparation condition used poly(vinylidene fluoride) (PVDF) such as a material with the excellent chemical stability and the milder preparation condition. The performance of the reinforced MF membrane prepared obtained the average $0.3{\mu}m$ pore size, $42kg_f/cm^2$ tensile strength, and the high water flux of 600 LMH. The change of membrane performance with various additives was considerably affected on the water flux and rejection. For hydrophilic modification of hydrophobic PVDF MF membrane, the MF membrane might be prepared with a prefer water flux and rejection by addition of hydrophilic poly(methyl methacrylate) (PMMA).

Applications of MF and UF Membrane for Drinking Water Treatment (MF/UF막을 이용한 음용수 처리현황 및 전망)

  • 김정학
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.09a
    • /
    • pp.94-104
    • /
    • 1996
  • 막형 정수기에 있어서 정수능력은 입증되었으나 다각적인 성능평가 결과는 없었다. 그러나 MAC 21 Project는 여러가지 막을 사용한 매우 다양한 실험조건에 대한 결과이므로 이것이 음용수처리에 대한 UF/MF막의 유효성을 증명하는 것으로 판단되어 자세히 기술하고자 한다.

  • PDF

Improvement of Fouling in Membrane Separation Process for Leachate Treatment using Ultrasound(II) : Analysis of Membrane Materials, Solutes and Multi-ultrasonic Effect (초음파를 이용한 침출수 처리를 위한 막분리 공정의 막힘현상 개선(II) : 막의 재질, 용질과 복합초음파의 효과 분석)

  • Kim, Seok-Wan;Lim, Jae-Lim;Lee, Jun-Geol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.207-215
    • /
    • 2006
  • This study evaluated the effect of ultrasonic irradiation on reducing membrane fouling for the treatment of chemically treated leachate and biologically treated leachate. The experiments on improvement of membrane flux according to the membrane types(MF and UF) and membrane materials were performed with changing frequency(40 kHz and 120 kHz) and intensity(200 W and 400 W) of ultrasound in ultrasonic membrane separation apparatus which ultrasound can be periodically irradiated. Additionally, the effect of dual frequency ultrasound which 40 kHz md 120 kHz are irradiated simultaneously was evaluated. The improvement of membrane flux by periodical ultrasound irradiation was higher in microfiltration(MF) membrane than in ultrafiltration(UF) membrane. It was sustained more in the MF membrane of polyvinylidene fluoride(PVDF) than in that of polysulfon(PS). Ultrasonic improvement of membrane flux was different depending on the characteristics of target wastewater. It was sustainably maintained without reclogging using dual frequency ultrasound although the improvement of membrane flux was lower.

Application of Ceramic MF Membrane at the Slow Sand Filtration Process (완속모래여과 공정에서 세라믹 MF 막의 적용)

  • Choi, Kwang-Hun;Park, Jong-Yul;Kim, Su-Han;Kim, Jeong-Sook;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.877-882
    • /
    • 2013
  • The application of ultrafiltration (UF) and microfiltration (MF) membranes has been increased for drinking water purification. The advantages of UF/MF membrane process compared to conventional treatment processes are stable operation under varying feed water quality, smaller construction area, and automatic operation. Most membrane treatment plants are designed with polymeric membranes. Recently, some studies suggested that the process of treating surface water with ceramic membranes is competitive to the application of polymeric membranes. Higher water flux, less frequent cleaning, and much longer lifetime are the advantages of ceramic membrane comparing to polymeric membrane. Therefore, this research focused on the application of ceramic MF membrane pilot plant at the slow sand filtration plant. The ceramic membrane pilot plant has three trains that used raw water and sand filtered water as a feed water, respectively. For optimizing the pilot plant process, the coagulation with PACl coagulant was used as a pretreatment of ceramic membrane process. In addition, CEB (Chemical Enhanced Backwash) process using $H_2SO_4$ and NaOCl was used for 1.5 days, respectively. The experimental results showed that applying the optimum coagulant dose before membrane filtration showed enhancing membrane fluxes for both raw water and sand filtered water. Also, when using raw water as a feed of membrane, minimum fouling rate was 2.173 kPa/cycle with 25 mg/L of PACl and when using sand filtered water, the minimum fouling rate was 0.301 kPa/cycle with 5 mg/L of PACl.

Improvement of Pressurized MF Pretreatment in MF/RO Process for Reuse (하수방류수 재이용 MF/RO 공정에서 가압식 MF의 전처리 성능 향상 방안 연구)

  • Na, Yumee;Park, Yong-Min;Lee, Yang-Woo;Kim, Won Kyong;Kim, Ji-Tae;Cho, Il-Hyoung
    • Membrane Journal
    • /
    • v.24 no.5
    • /
    • pp.350-357
    • /
    • 2014
  • Pressurized MF membranes are used to remove suspended solid and colloidal materials of wastewater treatment plant effluent as the pretreatment of RO in reuse water production process. Membrane operation data and pollutants removal efficiency are investigated using 100 t/d scale pilot plant in J wastewater treatment plant located in Namyangju city. 40 LMH flux of pressurized MF membrane are obtained in various turbidity and temperature condition. Coagulation of dissolved organic enables flux improvement of MF from 40 LMH to 60 LMH. Pressure drop of 1st RO elements rapidly increased after long-term pause, which is because the complex contamination of organic matter and ionic substances of pluming systems.

Advanced Water Treatment by UF/MF Membranes (UF/MF막을 이용한 고도수처리)

  • 김기협
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.06a
    • /
    • pp.105-142
    • /
    • 1997
  • We know very well the importance of water. Recently, we perceive the truth that water influence the quality of products and we must pay for it. Besides, we recognize why the water treatment is indispensable for life as well as industries. The variation of environment changes the natural resources and threatens the human life. Now, we cannot get water freely from nature. We should find new processes which are effective and inexpensive. We believe that the membrane technology can suggest the new way of water treatment. I'd like to explain the situation of water resource and the membrane processes by UF/MF membranes. I'll also introduce several case studies in this lecture. Till now, about 10 MF/UF systems were established in Korea. Of course, the usage of MF/UF for water treatment is beginning stage in Korea. But the future prospect is very good. Korean government has been developed various kinds of membrane processes for the purpose of drinking water, water reuse, development of new water resources and water related technologies, etc. In near future, maybe we will meet serious water problems, water deficiency and contamination. Fortunetely, we can suggest the membrane process for solving those problems. Membrane technology will be the base of clean technology.

  • PDF

MF Membrane Application for Water Treatment in Japan

  • Okazaki, Minoru
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.10a
    • /
    • pp.80-93
    • /
    • 1995
  • Membrane Technology, which has been in use for over twenty five years, has established itself as one of the principle separation methods. With improved technology, Reverse Osmosis ("RO") has been applied to large volume water treatment facilities. UF and MF Membrane Technology has, up until recently, been applied to small scale water treatment facilities. The fouling of membrane has restricted the growth of Membrane Technology in Water Treatment. Membrane fouling compound found in water causes the loss of flux across the membrane by absorbing to membrane and plugging their pores. Various methods have been used in the reduction and prevention of membrane fouling. For RO, a conventional pre-treatment system removes the pollutants, preventing the function decline of RO membrane by keeping SDI < 4 as the standard condition of feed water. UF and MF Membrane Technology that must have pre-treatment function within itself, are required to keep its ability not to be influenced by fouling.y fouling.

  • PDF