• Title/Summary/Keyword: MDT

Search Result 62, Processing Time 0.027 seconds

A Study on the AVLS using VHF base on GPS (GPS기반 VHF를 이용한 AVLS에 대한 연구)

  • Yun, Jae-Jun;Choi, Jo-Cheon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.256-260
    • /
    • 2005
  • For the structure of AVLS is required to the GPS-MDT for realtime acquisition the position reporting of vehicle and traffic management S/W. It is necessary that the MODEM using VHF transceiver base on GPS and monitoring program for display base on GIS the traffic status by vehicles position report in management system. The other wise, vehicles among management system that is required the automatic communications protocol for GPS information and mobile's ID. In this paper have studied the VHF modem for transmission the voice and data at same time and S/W for management system using GIS-tool.

  • PDF

Immediate Effects of Moving Myofascial Decompression Therapy for Young Adults with Nonspecific Neck Pain

  • Min, Kayoon;Kim, Namwoo;Lee, Yongwoo
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.2
    • /
    • pp.116-123
    • /
    • 2021
  • Objective: The purpose of this study was to investigate the effects of myofascial decompressiontherapy using moving suction on body temperature, pain, neck disability index, and cervical rotation for young adult with nonspecific neck pain. Design: Two-group pretest-posttest design. Methods: The subjects were randomly assigned 22 patients with chronic cervical pain who met the study conditions to the experimental group (n=11) and the control group (n=11). In the experimental group, the myofascial decompressiontherapy (MDT) was performed for 10 minutes using moving suction withnegative 15 mmHg pressure from the insertion to the origin of the upper trapezius muscle, while the control group without negative pressure. In order to investigate the effects of the intervention, an infrared thermometer, a visual analogue scale, neck disability index, and goniometer were used. Results: As a result of comparing the pre- and post- changes in each group according to the intervention, skin temperature, pain, neck disability index, and cervical rotation in both the experimental and control groups were significantly improved (p<0.05). Comparison of pre- and post- changes between the experimental and control groups showed significant differences for pain and cervical rotation (p<0.05), but no significant difference was found in the body temperature and neck disability index. Conclusions: Based on the results, MDT using moving suction was effective in reducing pain and increasing of cervical rotation for young adult with nonspecific neck pain.

Development of Multiparticulate-system Composed of Sustained Release-microspheres of Pseudoephedrin${\cdot}$HCI and Immediate Release-pellets of Terfenadine Using Solvent Evaporation Method and Spherically Agglomerated Crystallization Process (수용성 염산슈도에페드린과 난용성 테르페나딘의 구형정석조립법과 액중미립구법을 이용한 서방성펠렛 복합제제의 개발)

  • Rhee, Gye-Ju;Do, Ki-Chan;Kim, Eun-Hee;Park, Jong-Bum;Whang, Sung-Joo
    • YAKHAK HOEJI
    • /
    • v.41 no.3
    • /
    • pp.305-311
    • /
    • 1997
  • Sustained release-microspheres and immediate release-pellets were prepared to develop a controlled release multiparticulate system containing both water soluble and insoluble dr ug. Pseudoephedrin.HCl (EPD) and terfenadine (TRF) were used as model drugs, respectively. Sustained release-EPD microspheres were prepared by solvent evaporation method using Eudragit RL or RS as a matrix combined with pH-insensitive film coating. Smaller EPD microspheres were obtained when smaller amount of Eudragit as a matrix material or larger amount of magnesium stearate as a dispersing agent was used. However the obtained microspheres did not show syfficient sustained release characteristics. About 97% of EPD was released after 1 hr irrespective of matrix material used. Subsequent coating of the microspheres with pH-insensitive polymer such as Eudragit RS or ethylcelulose (EC) resulted good sustained in 37.5, 73.3 and 92.0% release of encapsulated EPD in distilled water after 1, 3 abd 7 hr, respectively. It corresponds to mean dissolution time (MDT) of 2.3 hr, which is much larger than that of un-coated EPD microspheres (0.0048 hr). Immediate release TRF pellets were prepared by spherically agglomerated crystallization using Eudragit E as an inert matrix and methylene chloride as a liquid binder. Using Eudragit E alone as a matrix resulted in satisfactory physical properties of the pellets such as sphericity, surface texture and flowability, but led to slower release of TRF from pellets than un-modified TRF powder (MDT of 1.70 vs 1.43 hr in pH 1.2 dissolution medium). Introducing propylene glycol or sodium lauryl sulfate as an emulsifier brought about faster release of TRF from pellets (MDT of 1.14 and 0.95 hr, respectively). In conclusion, microencapsulation by solvent evaporation combined with film coating and spherically agglomerated crystallization were successfully utilized to prepare controlled release multiparticulate system composed of sustained release EPD-microspheres and immediate release TRF pellets.

  • PDF

Volume and Mass Doubling Time of Lung Adenocarcinoma according to WHO Histologic Classification

  • Jung Hee Hong;Samina Park;Hyungjin Kim;Jin Mo Goo;In Kyu Park;Chang Hyun Kang;Young Tae Kim;Soon Ho Yoon
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.464-475
    • /
    • 2021
  • Objective: This study aimed to evaluate the tumor doubling time of invasive lung adenocarcinoma according to the International Association of the Study for Lung Cancer (IASLC)/American Thoracic Society (ATS)/European Respiratory Society (ERS) histologic classification. Materials and Methods: Among the 2905 patients with surgically resected lung adenocarcinoma, we retrospectively included 172 patients (mean age, 65.6 ± 9.0 years) who had paired thin-section non-contrast chest computed tomography (CT) scans at least 84 days apart with the same CT parameters, along with 10 patients with squamous cell carcinoma (mean age, 70.9 ± 7.4 years) for comparison. Three-dimensional semiautomatic segmentation of nodules was performed to calculate the volume doubling time (VDT), mass doubling time (MDT), and specific growth rate (SGR) of volume and mass. Multivariate linear regression, one-way analysis of variance, and receiver operating characteristic curve analyses were performed. Results: The median VDT and MDT of lung cancers were as follows: acinar, 603.2 and 639.5 days; lepidic, 1140.6 and 970.1 days; solid/micropapillary, 232.7 and 221.8 days; papillary, 599.0 and 624.3 days; invasive mucinous, 440.7 and 438.2 days; and squamous cell carcinoma, 149.1 and 146.1 days, respectively. The adjusted SGR of volume and mass of the solid-/micropapillary-predominant subtypes were significantly shorter than those of the acinar-, lepidic-, and papillary-predominant subtypes. The histologic subtype was independently associated with tumor doubling time. A VDT of 465.2 days and an MDT of 437.5 days yielded areas under the curve of 0.791 and 0.795, respectively, for distinguishing solid-/micropapillary-predominant subtypes from other subtypes of lung adenocarcinoma. Conclusion: The tumor doubling time of invasive lung adenocarcinoma differed according to the IASCL/ATS/ERS histologic classification.

Work Process of Connecting Rod Die using CAD/CAM/CNC (CAD/CAM/CNC를 활용한 커넥팅 로드 금형의 제작)

  • 이종선;이환희
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.393-398
    • /
    • 2001
  • This paper aims to work process of connecting rod die using CAD/CAM/CNC systems. CAD/CAM/CNC systems are consist of CAD(MDT4.0), CAM(Z-MASTER) software and CNC milling machine. CAM software is purpose to G-code generation for CNC programming. Then CAM software and CNC milling machine are connect to RS-232-C cable for data network.

  • PDF

A Study on protocol analysis between KTX control system and sub-devices (고속열차(KTX)제어시스템과 하부장치간 프로토콜 분석연구)

  • Kim, Hyeong-In;Jung, Sung-Youn;Kim, Hyun-Shik;Jung, Do-Won;Kim, Chi-Tae;Kim, Dong-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.179-186
    • /
    • 2007
  • KTX control systems mutually control OBCS, ATC, MBU, TECA, MDT, ABU, HVAC, TRAE, PID and FDTR, KTX OBCS as master, and controls other sub-control devices as slave, using various serial lines. In order to analyze physical structure of various serial link lines and mutual data transmission structure, serial line analyzer is used in many ways. To use serial line analyzer, prior and professional technics about High Speed Train and experience of using device are necessary. In spite of difficult situation of space and environment where we work for maintenance of High Speed Train, in presenting basic structure about physical connection method aquired by sub-device serial line data collection and about communication data analysis, I hope that this research will be helpful for the person who work for similar area. Also, I hope that this research will help diagnostic work of High Speed Train, which is necessary for test run of independently developed High Speed Train.

  • PDF

Structural Design of a Dental Implant (2): Test Drafting and Manufacturing (치과용 임플란트 구조설계 (2): 시험설계 및 가공제작)

  • Kwon, Young-Joo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.5
    • /
    • pp.433-438
    • /
    • 2012
  • This paper is the second paper among two papers which constitute the paper about the structural design of a dental implant. This paper completed the test drafting for the structural model of the new dental implant whose structural performance was confirmed and verified through the comparative structural analysis carried out in the first paper. This paper finished the structural design of a dental implant by manufacturing the dental implant using CNC machines and so forth on the basis of the completed draft and finally by evaluating the machining condition of the dental implant. The drafting work was performed using MDT(Mechanical Desk Top). The manufacturing work was carried out using CNC machines, general purpose milling machine, and Wire EDM. The manufactured surface condition of the dental implant was evaluated and confirmed finally using an electron microscope. As a result of evaluation, a testing dental implant with very good condition was designed and manufactured.

Attenuation and Protective Effects of a Thermostable Newcastle Disease Virus Isolated from Korean Pheasants (한국산 꿩으로부터 분리한 열 안정성 뉴캣슬병 바이러스의 순화와 방어효과)

  • 한수철;곽길한;김태중;장경수;전무형;송희종
    • Korean Journal of Poultry Science
    • /
    • v.27 no.2
    • /
    • pp.109-114
    • /
    • 2000
  • The objective of these experiments was to develop an attenuated thermostable Newcastle disease virus(NDV), CBP-1 strain isolated from infected pheasants. Safety, pathogenicity and protective effects against velogenic NDV were also investigated to evaluate if the attenuated NDV, CBP-1 strain could be a candidate for a new NDV vaccine strain. CBP-1 strain was passaged up to the 173 times by nine days old embryonated eggs and chicken embryo fibroblast(CEF) cell cultures. Its sensitivitly to lipid solvents and low pH, thermostability, mean death time(MDT), intracerebral pathogenicity index(ICPI) of one day old chicks and intravenous pathogenicity index(IVPI) of four weeks old chicks were examined. Safety, boosting and protective effects were tested by chicks mortality. CBP-1 NDV strain had significant thermostability at 56$\^{C}$ for 30 minutes. by hemagglutinin activity and egg infectivity test, but was not resistant to lipid solvent. It showed possibility to use as a feed or water vaccine because of the resistance to low pH. MDT, ICPI and IVPI of CBP-1 were attenuated from 51.5, 1.96, 2.60 to 112.4, 1.12, 1.45. These results implied that the 173rd passages in embryonated egg and CEF cell cultures induced a substantial attenuation of the pathogenicity of the parent virus, changing the virulence from velogenic to intermediate between mesogenic and lentogenic. After vaccination with CBP-1 at one day old by drinking water mortality was 17.5%. However, spray vaccination with B1 at one day old, CBP-1 at two weeks ild and challenge with velogenic Kyojeongwon strain at four weeks old showed 93.5% survival rate. Mortality of chicks, vaccination with 173rd passaged CBP-1 strain at one day old, two weeks old and challenge with Kyokeongwon strain at four weeks old, was 20.0%. The results of these studies indicated that partial attenuated CBP-1 strain tended to be a low safety for ND of broiler chicks and would need to be more successive attenuation.

  • PDF

Development of a Compact-type GIS Engine for Mobile Map Services (모바일 지도 서비스를 위한 Compact형 GIS 엔진의 개발)

  • 신진호;이봉재;송재주;강주영;조선구
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10b
    • /
    • pp.130-132
    • /
    • 2004
  • 최근 무선통신망의 발전에 따라 무선 인터넷 시장이 빠르게 성장하면서 이동성을 기반으로 하는 서비스에 대한 관심이 고조되고 있다. 그리고 휴대폰과 PDA(Personal Digital Assistants), MET(Mobile Data Terminal)와 같은 휴대용 단말기의 사용이 일반화된 가운데 GPS(Global Positioning System)를 기반으로 하는 서비스들도 점차적으로 보편화되어 가고 있다. 이러한 변화에 따라 이동성을 지원하는 무선 단말기를 기반으로 한 Mobile GIS 환경에서의 위치 정보 활용은 큰 관심을 불러일으키고 있으며, 또한 이러한 서비스를 효율적으로 제공하기 위해서 위치 기반 서비스(LBS: Location Based Service)의 기술개발이 필요하게 되었다. 이 논문에서는 전력설비 고장복구업무에 LBS를 적용하기 위해 차량에 장착하는 MDT에서 모바일 지도 서비스가 가능한 Compact형 GIS 엔진을 설계하고 구현한 결과를 제시한다.

  • PDF

Design Process Improvement through the Integration of Commercial Software (상용 소프트웨어의 통합을 통한 설계 및 검증 시간 단축을 위한 연구)

  • Jung, Hyun-Seok;Cho, Woo-Seok
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2005.05a
    • /
    • pp.1108-1113
    • /
    • 2005
  • 한국정부가 제조물책임법을 2002년 7월에 도입한 이래, 많은 제조업체가 설계해석 툴의 도입을 검토하고 있다. 또한, 원청업체의 요청에 의해 설계해석 툴을 도입하기도 한다. 일반적으로 설계 해석 툴들은 엄청나게 복잡하고 방대한 지식을 포함하고 있기 때문에, 이 툴을 사용하는 해석 전문가 역시 전문가는 설계 및 분야에 관한 방대한 지식을 터득해야 한다. 따라서, 중소기업에 이런 툴을 도입하기 위해서는, 도입비용 뿐 아니라, 운용 인력 확보에도 상당한 애로를 겪고 있다. 본 연구에서는, 신축관을 설계하는 업체를 대상으로 하여, 신축관의 특성을 이해하기만 하면 해석이 가능한 시스템을 구축하여, 해석 툴의 사용자 범위를 확대하고자 한다. 이 목표를 달성하기 위하여, MS-Excel, MDT, ANSYS를 통합하였으며, 이 연구결과로, 특별한 교육을 받지 않은 설계자도 이 통합 시스템을 운용할 수 있고, 설계 및 검증 시간을 획기적으로 단축할 수 있음을 확인하였다.

  • PDF