• Title/Summary/Keyword: MD-2

Search Result 1,566, Processing Time 0.028 seconds

Impact of Current Density, Operating Time and pH of Textile Wastewater Treatment by Electrocoagulation Process

  • Hossain, Md. Milon;Mahmud, Md. Iqbal;Parvez, Md. Shohan;Cho, Haeng Muk
    • Environmental Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.157-161
    • /
    • 2013
  • Treatment of textile wastewater by the electrocoagulation (EC) process is being investigated by this experimental study. The objective of this experiment is to observe the efficiency of the EC process in removing chemical oxygen demand (COD) and turbidity. In this experiment an iron electrode is used in the EC process, and different working parameters such as pH, current density and operating time were studied in an attempt to achieve a higher removal capacity. The results show that the maximum COD removal occurred at neutral pH at operating time 30 min. COD and turbidity removal reaches at maximum, with optimum consumption of electrodes, between current density 85-95 $A/m^2$, and only trace amounts of metals were determined in the EC treated effluent.

Ultrahigh Birefringence and Extremely Low Loss Slotted-core Microstructure Fiber in Terahertz Regime

  • Habib, Md. Ahasan;Anower, Md. Shamim;Hasan, Md. Rabiul
    • Current Optics and Photonics
    • /
    • v.1 no.6
    • /
    • pp.567-572
    • /
    • 2017
  • A novel slotted-core hexagonal photonic crystal fiber (PCF) for terahertz (THz) wave guiding is proposed in this paper. A trade-off managed between effective material loss (EML) and birefringence for efficient guidance of THz waves is illustrated in this article. The rectangular slot shaped air-holes break the symmetry of the porous-core which offers ultra-high birefringence of $8.8{\times}10^{-2}$. The proposed structure offers low bending loss of $1.07{\times}10^{-34}cm^{-1}$ and extremely low effective material loss (EML) of $0.035cm^{-1}$ at an operating frequency of 1.0 THz. In addition other guiding properties such as power fraction, dispersion and confinement loss are also discussed. The proposed THz waveguide can be effectively used for convenient transmission of THz waves.

A case report of Madelung's disease

  • Jang, Nam;Shin, Hyun Woo;Kim, Junekyu;Yoon, Kun Chul
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.5
    • /
    • pp.305-308
    • /
    • 2020
  • Madelung's disease (MD) otherwise known as Launois-Bensaude syndrome, multiple symmetrical lipomatosis, or benign symmetric lipomatosis, is a rare disease characterized by abnormal diffuse lipomatosis in proximal upper limbs and neck. Here, we report a rare case of MD. A 66-year-old man presented with massive growth of soft tissues in the cervico-occipital region of more than 2 years duration. Physical examination showed diffuse enlargement of the anterior neck (Madelung's collar) and three huge humps at the posterior neck. Under a diagnosis of MD, lipectomy via a single anterior transverse incision and liposuction were performed. This rare case report may be helpful for assessing patients with abnormal diffuse lipomatosis in the neck and proximal upper limbs.

Water cost analysis of different membrane distillation process configurations for brackish water desalination

  • Saleh, Jehad M;Ali, Emad M.;Orfi, Jamel A;Najib, Abdullah M
    • Membrane and Water Treatment
    • /
    • v.11 no.5
    • /
    • pp.363-374
    • /
    • 2020
  • Membrane distillation (MD) is a process used for water desalination. However, its commercialization is still hindered by its increased specific cost of production. In this work, several process configurations comprising Direct Contact and Permeate Gap distillation membrane units (PGMD/DCMD) were investigated to maximize the production rate and consequently reduce the specific water cost. The analysis was based on a cost model and an experimentally validated MD model. It was revealed that the best achievable water cost was approximately 5.1 $/㎥ with a production rate of 8000 ㎥/y. This cost can be further decreased to approximately 2 $/㎥ only if the heating and cooling energies are free of cost. Therefore, it is necessary to decrease the MD capital investment to produce pure water at economical prices.

Mixed LJ particles MD를 이용한 혼합물의 밀도, 온도 별 방사 분포 연구

  • Lee, Min-Jun;Park, Hui-Su
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.53-65
    • /
    • 2013
  • 두 물질의 단순 혼합물에서 각 물질이 어떤 상을 가지고 행동하는지는 순수 과학은 물론이고 그것을 적용하는 공학에서도 역시 중요하다. 계를 표현하는 여러 가지 방법이 있지만, Lennard-Jones potential이 그 중 가장 단순하면서도 효과적이기 때문에 널리 쓰인다. 이 연구는 입자간의 에너지가 Lennard-Jones potential로 표현된 혼합물의 상변화를 Chemworks2의 "Mixed LJ particles MD" 프로그램으로 모사 실험 하고, 그 결과를 방사 분포 함수를 통해 분석했다. 분석을 통해서 Lennard-Jones 상수가 다른 두 가지의 경우에 대하여 각각 혼합물의 온도와 밀도 변화에 따른 상변화가 다르게 나타나는 것을 보였다.

  • PDF

Experimental Animal Models for Meniere's Disease: A Mini-Review

  • Seo, Young Joon;Brown, Daniel
    • Korean Journal of Audiology
    • /
    • v.24 no.2
    • /
    • pp.53-60
    • /
    • 2020
  • Several novel animal models that represent the pathophysiological process of endolymphatic hydrops (ELH) of Meniere's disease (MD) have been developed. Animal models are important to identify and characterize the pathophysiology of ELH and to corroborate molecular and genetic findings in humans. This review of the current animal models will be useful in understanding the pathophysiology of and developing proper treatments for MD. Surgical animal models will be replaced by medication-induced animal models. Study models previously developed in guinea pigs will be developed in several smaller animals for ease of conducting molecular analysis. In this review, we provided updated resources including our previous studies regarding the current and desirable animal models for MD.

Experimental Animal Models for Meniere's Disease: A Mini-Review

  • Seo, Young Joon;Brown, Daniel
    • Journal of Audiology & Otology
    • /
    • v.24 no.2
    • /
    • pp.53-60
    • /
    • 2020
  • Several novel animal models that represent the pathophysiological process of endolymphatic hydrops (ELH) of Meniere's disease (MD) have been developed. Animal models are important to identify and characterize the pathophysiology of ELH and to corroborate molecular and genetic findings in humans. This review of the current animal models will be useful in understanding the pathophysiology of and developing proper treatments for MD. Surgical animal models will be replaced by medication-induced animal models. Study models previously developed in guinea pigs will be developed in several smaller animals for ease of conducting molecular analysis. In this review, we provided updated resources including our previous studies regarding the current and desirable animal models for MD.

Diffusion Tensor Imaging and Cerebrospinal Fluid Flow Study of Cine Phase Contrast in Normal Cervical Spinal Cords (정상인 경수에 대한 확산텐서영상과 PC기법을 이용한 뇌척수액 속도 측정에 관한 연구)

  • Son, B.K.;Kwak, S.Y.;Han, Y.H.;Yoo, J.S.;Kim, O.H.;Ko, H.Y.;Mun, C.W.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.123-132
    • /
    • 2013
  • Purpose : We report the results of the various parameters of diffusion tensor imaging (DTI) and CSF flow study of the cervical spinal cord using magnetic resonance (MR) imaging techniques. Materials and Methods: Intramedullary FA and MD were measured in the gray matter and posterior cord of the white matter and both lateral cords of the white matter at the C2-3, C4-5, C5-6 spinal levels. For the CSF flow study, velocity encoding was obtained at the C2-3, C4-5, C5-6 spinal levels. Results: There was a significant difference of the FA and MD between the white matter and gray matter (p < 0.05). The FA of the gray matter was significantly different according to the cervical spinal cord levels (p < 0.05). Otherwise, the FA and MD parameters were not significantly different (p > 0.05). The mean peak systolic velocity and mean peak diastolic velocity were $5.18{\pm}2.00cm/sec$ and $-7.32{\pm}3.18cm/sec$, respectively from C2 to C6 spinal cords. There was no significant difference in these velocities among the cervical spinal cord (p > 0.05). Conclusion: This basic information about DTI and CSF dynamics of the cervical spinal cord may be useful for assessing cervical spinal cord abnormalities using MR imaging.

Emerging membrane technologies developed in NUS for water reuse and desalination applications: membrane distillation and forward osmosis

  • Teoh, May May;Wang, Kai Yu;Bonyadi, Sina;Yang, Qian;Chung, Tai-Shung
    • Membrane and Water Treatment
    • /
    • v.2 no.1
    • /
    • pp.1-24
    • /
    • 2011
  • The deficiency of clean water is a major global concern because all the living creatures rely on the drinkable water for survival. On top of this, abundant of clean water supply is also necessary for household, metropolitan inhabitants, industry, and agriculture. Among many purification processes, advances in low-energy membrane separation technology appear to be the most effective solution for water crisis because membranes have been widely recognized as one of the most direct and feasible approaches for clean water production. The aim of this article is to give an overview of (1) two new emerging membrane technologies for water reuse and desalination by forward osmosis (FO) and membrane distillation (MD), and (2) the molecular engineering and development of highly permeable hollow fiber membranes, with polyvinylidene fluoride (PVDF) and polybenzimidazole (PBI) as the main focuses for the aforementioned applications in National University of Singapore (NUS). This article presents the main results of membrane module design, separation performance, membrane characteristics, chemical modification and spinning conditions to produce novel hollow fiber membranes for FO and MD applications. As two potential solutions, MD and FO may be synergistically combined to form a hybrid system as a sustainable alternative technology for fresh water production.

Influences of Shoe Heel Height on Isometric Shoulder Abductor Strength and EMG Activities of Selected Shoulder Muscles (신발 뒤굽 높이가 등척성 어깨 외전 근력과 근전도 활동에 미치는 영향)

  • Oh, Duck-Won
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.2
    • /
    • pp.9-16
    • /
    • 2015
  • PURPOSE: The objective of this study was to identify the effects of shoulder abduction strength and EMG activities of the selected scapular and shoulder muscles during isometric shoulder abduction. METHODS: Thirty-four healthy young females were recruited for this study. Surface EMG equipment with inline force sensor was used to determine the shoulder abductor strength and the activity of the serratus anterior (SA), upper trapezius (UT), lower trapezius (LT), and middle deltoid (MD) during three shoe heel height conditions: (1) barefoot, (2) 3-cm shoe heel height, and (3) 7-cm shoe heel height. RESULTS: Isometric shoulder strength showed statistically significant difference among the conditions (p<0.05), and post-hoc test showed lower strength during the 7-cm condition ($49.98{\pm}17.56kg$) than during the barefoot ($44.97{\pm}20.15kg$) and 3-cm conditions ($36.59{\pm}17.07kg$). Furthermore, EMG activities of the SA, UT, and MD appeared to be statistically significantly different among the conditions, with lower values in the 7-cm condition compared to the barefoot condition (p<0.05). EMG ratios (MD/UT and SA/UT) were lower during the 7-cm condition than during the barefoot condition (p<0.05). CONCLUSION: These findings suggest that isometric shoulder abduction strength and EMG activities of scapular and shoulder muscles may be adversely changed with increasing shoe heel height.