• Title/Summary/Keyword: MCTS

Search Result 37, Processing Time 0.026 seconds

Deciphering the underlying mechanism of liver diseases through utilization of multicellular hepatic spheroid models

  • Sanghwa Kim;Su-Yeon Lee;Haeng Ran Seo
    • BMB Reports
    • /
    • v.56 no.4
    • /
    • pp.225-233
    • /
    • 2023
  • Hepatocellular carcinoma (HCC) is a very common form of cancer worldwide and is often fatal. Although the histopathology of HCC is characterized by metabolic pathophysiology, fibrosis, and cirrhosis, the focus of treatment has been on eliminating HCC. Recently, three-dimensional (3D) multicellular hepatic spheroid (MCHS) models have provided a) new therapeutic strategies for progressive fibrotic liver diseases, such as antifibrotic and anti-inflammatory drugs, b) molecular targets, and c) treatments for metabolic dysregulation. MCHS models provide a potent anti-cancer tool because they can mimic a) tumor complexity and heterogeneity, b) the 3D context of tumor cells, and c) the gradients of physiological parameters that are characteristic of tumors in vivo. However, the information provided by an multicelluar tumor spheroid (MCTS) model must always be considered in the context of tumors in vivo. This mini-review summarizes what is known about tumor HCC heterogeneity and complexity and the advances provided by MCHS models for innovations in drug development to combat liver diseases.

Delivery of Spatial Partitioning Information for Tile-based Adaptive Bitrate Streaming Using MMT Protocol (MMT 프로토콜을 활용한 타일 기반 적응형 비트율 스트리밍을 위한 영상 분할 정보 전달 기법)

  • An, Eunbin;Kim, Ayoung;Seo, Kwangdeok
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2020.07a
    • /
    • pp.51-54
    • /
    • 2020
  • 본 논문에서는 360 도 VR 영상을 전송하는 기법의 일종인 타일 기반 전송을 MMT(MPEG Media Transport) 프로토콜 기반으로 구현하기 위하여 영상의 공간 분할 정보를 전달하는 방법을 소개한다. 360 도 VR 영상 전송은 대용량 미디어 전송인 동시에 사용자의 움직임에 따라 신속하게 적응적 영상을 전달해야 한다. 타일 기반 전송은 HEVC(High Efficiency Video Coding)의 MCTS(Motion Constrained Tile Sets) 기법을 이용하여 뷰포트에 해당하는 타일들을 고화질로 전달함으로써 이러한 요구사항을 해결한다. 반면, MMT 프로토콜은 초저지연 고화질 영상 전송에 유리한 기술로써 사용자의 시점 변화에 따라 기민하게 영상의 품질을 변환시킬 수 있다. 따라서 HEVC 의 SEI(Supplemental Enhancement Information) 메시지에 포함되는 타일들의 공간 분할 정보를 MMT 프로토콜에 적용하는 방식에 따라 적응적 타일 기반 전송 기법의 효율을 높일 수 있다.

  • PDF

Effects of Vth adjustment ion implantation on Switching Characteristics of MCT(MOS Controlled Thyristor) (문턱전압 조절 이온주입에 따른 MCT (MOS Controlled Thyristor)의 스위칭 특성 연구)

  • Park, Kun-Sik;Cho, Doohyung;Won, Jong-Il;Kwak, Changsub
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.69-76
    • /
    • 2016
  • Current driving capability of MCT (MOS Controlled Thyristor) is determined by turn-off capability of conducting current, that is off-FET performance of MCT. On the other hand, having a good turn-on characteristics, including high peak anode current ($I_{peak}$) and rate of change of current (di/dt), is essential for pulsed power system which is one of major application field of MCTs. To satisfy above two requirements, careful control of on/off-FET performance is required. However, triple diffusion and several oxidation processes change surface doping profile and make it hard to control threshold voltage ($V_{th}$) of on/off-FET. In this paper, we have demonstrated the effect of $V_{th}$ adjustment ion implantation on the performance of MCT. The fabricated MCTs (active area = $0.465mm^2$) show forward voltage drop ($V_F$) of 1.25 V at $100A/cm^2$ and Ipeak of 290 A and di/dt of $5.8kA/{\mu}s$ at $V_A=800V$. While these characteristics are unaltered by $V_{th}$ adjustment ion implantation, the turn-off gate voltage is reduced from -3.5 V to -1.6 V for conducting current of $100A/cm^2$ when the $V_{th}$ adjustment ion implantation is carried out. This demonstrates that the current driving capability is enhanced without degradation of forward conduction and turn-on switching characteristics.

Preparation and Characterization of Resveratrol Nanoemulsions Stabilized by Self-assembly and Complex Coacervation Consisting of Sodium Alginate, Chitosan, and β-Cyclodextrin

  • Choi, Ae-Jin;Jo, Younghee;Cho, Yong-Jin;Kim, Tae-Eun;Kim, Chong-Tai
    • Food Engineering Progress
    • /
    • v.21 no.3
    • /
    • pp.215-224
    • /
    • 2017
  • Resveratrol was incorporated into various combinations of single- and double-layer nanoemulsions, prepared by self-assembly emulsification and complex coacervation with chitosan, alginate, and ${\beta}$-cyclodextrin, respectively. Resveratrol nanoemulsions were composed of medium-chain trigacylglycerols (MCTs), $Tween^{(R)}$ 80, water, chitosan, alginate, and ${\beta}$-cyclodextrin. The corresponding mixtures were formulated for the purpose of being used as a nutraceutical delivery system. Resveratrol nanoemulsions were obtained with particle sizes of 10-800 nm, with the size variation dependent on the emulsification parameters including the ratio of aqueous phase and surfactant ratio. Resveratrol nanoemulsions were characterized by evaluating particle size, zeta-potential value, stability, and release rate. There were no significant changes in particle size and zeta-potential value of resveratrol nanoemulsions during storage for 28 days at $25^{\circ}C$. The stability of resveratrol in the double-layer nanoemulsions complexed with chitosan or ${\beta}$-cyclodextrin was higher, compared with the single-layer nanoemulsions.

Short-Wave Infrared Fluorescence-Guided Surgery Using Indocyanine Green in a Dog with a Cutaneous Mast Cell Tumor

  • Su-Hyeon Kim;Sungin Lee
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.395-399
    • /
    • 2022
  • A 6-year-old spayed, female golden retriever dog was presented with a skin mass on the dorsal region of the right carpus. The cytology result of the region revealed characteristics of mast cell tumors (MCTs). Short wave-infrared fluorescence-guided surgery using Indocyanine green (ICG) was performed to determine the surgical margin of the tumor. ICG was injected intravenously 24 hours before the surgery and the patient was hospitalized and carefully monitored. During the surgery, ICG fluorescence-based surgery was performed to identify the tumor and the surgical margin. The tumor was visible, and the skin mass was resected using NIR device for the guidance of the surgical margin of the tumor. Once the resection was complete, the surgical site was again inspected with SWIR fluorescence imaging to identify residual tumor cells. The resected tumor, using ICG navigation, was classified as low-grade cutaneous MCT and the margin was complete on the histopathological result. We report herein a case of resection of a cutaneous MCT in a dog using SWIR fluorescence imaging ICG which can be potentially used for the identification of tumors and evaluation of the surgical margin for complete resection.

Human body model electrostatic discharge tester using metal oxide semiconductor-controlled thyristors

  • Dong Yun Jung;Kun Sik Park;Sang In Kim;Sungkyu Kwon;Doo Hyung Cho;Hyun Gyu Jang;Jongil Won;Jong-Won Lim
    • ETRI Journal
    • /
    • v.45 no.3
    • /
    • pp.543-550
    • /
    • 2023
  • Electrostatic discharge (ESD) testing for human body model tests is an essential part of the reliability evaluation of electronic/electrical devices and components. However, global environmental concerns have called for the need to replace the mercury-wetted relay switches, which have been used in ESD testers. Therefore, herein, we propose an ESD tester using metal oxide semiconductor-controlled thyristor (MCT) devices with a significantly higher rising rate of anode current (di/dt) characteristics. These MCTs, which have a breakdown voltage beyond 3000 V, were developed through an in-house foundry. As a replacement for the existing mercury relays, the proposed ESD tester with the developed MCT satisfies all the requirements stipulated in the JS-001 standard for conditions at or below 2000 V. Moreover, unlike traditional relays, the proposed ESD tester does not generate resonance; therefore, no additional circuitry is required for resonant removal. To the best of our knowledge, the proposed ESD tester is the first study to meet the JS-001 specification by applying a new switch instead of an existing mercury-wetted relay.

Performance Analysis of Viewport-dependent Tiled Streaming on 16K Ultra High-quality 360-degree Video (16K 초고화질 360도 영상에서의 사용자 시점 기반 타일 스트리밍 성능 검증)

  • Jeong, Jong-Beom;Lee, Soonbin;Kim, Inae;Ryu, Eun-Seok
    • Journal of Internet Computing and Services
    • /
    • v.22 no.3
    • /
    • pp.1-8
    • /
    • 2021
  • Ultra high-quality and ultra high-resolution omnidirectional 360-degree video streaming is needed to provide immersive media through head-mounted display(HMD) in virtual reality environment, which requires high bandwidth and computational complexity. One of the approaches avoiding these problems is to apply viewport-dependent selective streaming using tile-based segmentation method. This paper presents a performance analysis of viewport-dependent tiled streaming on 16K ultra high-quality 360-degree videos and 4K 360-degree videos which are widely used. Experimental results showed 42.47% of bjotegaard delta rate(BD-rate) saving on 16K ultra high-quality 360-degree video tiled streaming compared to viewport-independent streaming while 4K 360-degree video showed 26.41% of BD-rate saving. Therefore, this paper verified that tiled streaming is more efficient on ultra-high quality video.