• Title/Summary/Keyword: MC50 cyclotron

Search Result 22, Processing Time 0.023 seconds

Design Features and Operating Characteristics of the MC-50 Cyclotron (MC-50 싸이클로트론의 설계 특징과 동작 특성)

  • Bak, Hae-Ill;Bak, Joo-Shik
    • Nuclear Engineering and Technology
    • /
    • v.21 no.3
    • /
    • pp.216-222
    • /
    • 1989
  • The MC-50 cyclotron at Korea Canter Center Hospital is now operational for neutron therapy and medical radioisotope production. Design features, mechanical structures and operating characteristics of the MC-50 are described in this paper. Optimum operating condition for this cyclotron has been determined by the repetitive running, and the performances of the internal beam have been investigated through the measurements of intensity and spatial distribution of the internal beam as a function of the radius of the cyclotron. Routinely, the 40 $\mu$A of 50 MeV protons have been obtained at first Faraday cup with a extraction efficiency of 61%.

  • PDF

KCCH Medical Cyclotron Operation for Neutron Therapy and Isotope Production (1989) - A Technical Report - (중성자 치료와 동위원소 생산을 위한 KCCH 의학용 싸이클로트론의 운영 (1989))

  • Kim, Byung-Mun;Kim, Young-Sear;Bak, Joo-Shik;Lee, Jong-Du;Yoo, Seong-Yul;Koh, Kyung-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.113-122
    • /
    • 1990
  • After four years of planning, equipment acquisition, facility construction and beam testing, the KCCH cyclotron facility was put into operation in November1986. Now the KCCH cyclotron(MC-50) has been used for four years in neutron therapy and radioisotope production. Up to December 1989, 179(1852 sessions) patient have undergone neutron therapy. Radioisotope production for nuclear medicine use was started from March 1989 after extensive work to overcome target transport, target melting, beam diagnostic and chemical processing problems. This status report introduces the cyclotron facility, and the experiences of neutron therapy and isotope production with the MC-50 cyclotron. Besides, the operation results and the general troubles of the MC-50 during 1989 are summarized. Total operation time was 1252.5 hours. Four hundred hours were used for neutron therapy of 599 treatment sessions and 832.5 hours for radioisotope production. Total amount of produced raioisotope was 1695 mCi(Ga-67 : 1478mCi, Tl-201 : 107 mCi, I-123 : 25mCi, In-111 : 85mCi). Twenty hours were used for scheduled beam testing. In 1989, 882% of the planned operation were performed on schedule and this rats is improved remarkably compared to 71.0% in 1988.

  • PDF

Design Study of an Axial Injection System for MC50 Cyclotron at KIRAMS

  • Kim, Jae-Hong;Cho, Sung-Jin;Choi, Jun-Yong;Hong, Seung-Pyo;Yu, In-Gong;Park, Hyun;Lee, Ji-Sup
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.262-262
    • /
    • 2012
  • A multi-purpose cyclotron, MC50 has been operated to provide multi-ions of proton, deuteron and alpha at Korea Institute of Radiological and Medical Sciences (KIRAMS). Neutron is also produced through the (p,n) nuclear process with a Be target. However, a wide spectrum of current of ions is requested by beam users for carrying their various application fields. Therefore a simulation study is requested on the design of an axial injection system for high current proton and alpha beam extraction for radio-isotope productions and scientific researches. The purpose of this study is seeking a relatively simple method for the MC50 having higher alpha beam capability and also improving proton and deuteron beams currently used. We are considering two possibilities to improve the internal ion source and to install a new external axial injection system. The external injection system will be consisted of an Einzel lens, a steering magnet, a buncher, and a glazer lens placed in front of an inflector, which is located at the center of the main magnet.

  • PDF

MC-50 의학용 싸이클로트론의 특성조사

  • Park, Ju-Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.2 no.1
    • /
    • pp.23-29
    • /
    • 1987
  • The general features and measured results of the 143cm, variable-energy, three sector-focused MC-50 cyclotron installed at Korea Cancer Center Hospital are described. The MC-50 cyclotron is designed to produce beams of protons, deuterons, He-3 and alpha particles of maximum energies 50MeV, 25MeV, 66MeV and 50MeV respectively to be used for neutron therapy and radioisotope production. The azimuthal field variation is produced by three sets of spiral ridges having a maximum spiral angle of $55^{\circ}$. The RF system, a two-dee quarter-wave system is designed to provide a continuously variable frequency from 15.5 to 26.8 MHz. The first external beam was obtained in January 1986. Subsequent internal ana external beam studies with protons and alphas show a well-behaved beam through the whole beam transport system.

  • PDF

Measurement of neutron spectra in MC50 cyclotron using Bonner sphere spectrometer with LiI scintillation detector (LiI 섬광검출기 기반의 보너구 스펙트로메터를 이용한 MC50 사이클로트론의 중성자스펙트럼 측정)

  • Ha, Wi-Ho;Park, Seyoung;Yoo, Jaeryong;Yoon, Seokwon;Lee, Seung-Sook;Kim, Jungho;Kim, Jong Kyoung
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.3
    • /
    • pp.143-148
    • /
    • 2013
  • Operational nuclear facilities such as nuclear power plants and particle accelerators show various neutron spectra according to the type of facilities and specific position. Necessities of neutron dose management and neutron monitoring for radiation protection of radiation workers in such a kind of facilities have continuously increased in recent years. Bonner sphere spectrometers are widely used for measurement of neutron spectra. Data on response function of neutron detector, default neutron spectra and count rates of Bonner sphere spectrometer are required to obtain unfolded neutron spectra in specific workplaces. In this study, we carried out measurement of neutron spectra produced in MC50 cyclotron using Bonner sphere spectrometer with LiI scintillation detector. Additionally, we estimated quantitative data on neutron flux, mean neutron energy and ambient dose equivalent rate according to the incident proton energies and positions in MC50 cyclotron.

The Production of Carrier Free Indium-111 with MC-50 Cyclotron (MC-50 싸이클로트론을 이용한 In-111 제법 개발)

  • Chun, K.S.;Suh, Y.S.;Yang, S.D.;Chai, J.S.;Jee, K.S.;Lee, J.D.
    • Journal of radiological science and technology
    • /
    • v.13 no.2
    • /
    • pp.43-49
    • /
    • 1990
  • [ $^{111}$ ]In has wide applications in nuclear medicine for labelling and in-vivo distribution studies. A method is developed for the production of carrier free $^{111}$In using the reaction $^{nat.}Cd(p,\;xn)$ $^{111}$In with MC-50 cyclotron. Carrier free $^{111}$In was separated from the irradiated metallic cadmium by liquid-liquid extraction and cation exchange chromatography. The yield of $^{111}$In at EOB is $0.8mCi/{mu}\;Ahr$ and the nuclidic purity is over 99%. $^{111}In-DTPA\;and\;^{111}In-bleomycin$ were prepared for medical study.

  • PDF

In vitro and in vivo Biological Responses of Proton Irradiation from MC-50 Cyclotron

  • Jung, Uhee;Eom, Hyeon Soo;Jeong, Kwon;Park, Hae-Ran;Jo, Sung-Kee
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.223-229
    • /
    • 2012
  • In this study, we investigated the biological damage and stress responses induced by ion beam (proton beam) irradiation as a basis for the development of protective measures against space radiation. We examined the biological effects of proton beam produced by MC-50 cyclotron at KIRAMS on the cultured cells and mice. The proton beam energy used in this study was 34.9 MeV and the absorption dose rate for cells and mice were $0.509Gy\;sec^{-1}$ and $0.65Gy\;sec^{-1}$, respectively. The cell survival rates measured by plating efficiency showed the different sensitivity and dose-relationship between CHO cells and Balb/3T3 cells. HGPRT gene mutation frequency in Balb/3T3 was $15{\times}10^{-6}Gy^{-1}$, which was similar to the reported value of X-ray. When stress signaling proteins were examined in Balb/3T3 cells, $I{\kappa}B-{\alpha}$ decreased markedly whereas p53, phospho-p53, and Rb increased after proton beam irradiation, which implied that the stress signaling pathways were activated by proton beam irradiation. In addition, cellular senescence was induced in IMR-90 cells. In the experiments with C57BL/6 mouse, the immune cells (white blood cells, lymphocytes) in the peripheral blood were greatly reduced following proton beam irradiation whereas red blood cells and platelets showed relatively little change. These results can be utilized as basic data for studying the biological effects of proton beam using MC-50 cyclotron with respect to proton therapy research as well as space radiation research.

RESEARCH ON SPACE ENVIRONMENTAL EFFECT OF ORGANIC COMPOSITE MATERIALS FOR THERMAL MANAGEMENT OF SATELLITES USING MC-50 CYCLOTRON (MC-50 싸이클로트론을 이용한 위성용 열조절 유기복합재료의 우주환경 영향 연구)

  • Kim, Dae-Weon;Kim, Dong-Iel;Huh, Yong-Hak;Yang, Tae-Keun;Lee, Ho-Young;Kim, Yong-Hyup
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.4
    • /
    • pp.441-450
    • /
    • 2005
  • The organic material is one of the most popular material for the satellites and the spacecrafts in order to perform the thermal management, and to protect direct exposure from the space environment. The present paper observes material property changes of organic material under the space environment by using ground facilities. One of the representative organic thermal management material of satellites, 2 mil ITO(Indium Tin Oxide) coated aluminized KAPTON was selected for experiments. In order to investigate the single parametric effect of protons in space environment, MC-50 cyclotron system in KIRAMS(Korea Institute of Radiological and Medical Science) was utilized for the ion beam irradiation of protons and ion beam dose was set to the Very Large August 1972 EVENT model, the highest protons occurrence near the earth orbit in history. The energy of ion beam is fixed to 30MeV(mesa electron volt), observed average energy, and the equivalent irradiance time conditions were set to 1-year, 3-year, 5-year and 10-year exposure in space. The procedure of analyses includes the measurement of the ultimate tensile strength for the assessment of quantitative degradation in material properties, and the imaging analyses of crystalline transformation and damages on the exposed surface by FE-SEM(Field Emission Scanning Electron Spectroscopy) etc.