• Title/Summary/Keyword: MC렌즈

Search Result 10, Processing Time 0.029 seconds

Effects of the Progression Control of Myopia on Myopia Control Lenses and Single Vision Lenses (Myopia Control 렌즈와 Single Vision 렌즈의 근시진행 조절 효과)

  • Jung, Ji-Won;Lee, Ki-Seok;Yoo, Wang-Keun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.19-26
    • /
    • 2012
  • Purpose: This paper was to study the clinical effects of moderating myopia by comparing the myopia control lens, which was being recently recognized as a method of inhibiting the progression of myopia, with the wearers of single vision lens. Methods: Using 56 subjects between the ages of 8-15 years (112 eyes) with myopia in the areas of City of Daegu and Gyeongsangbuk Province as study subjects, refractive error, axial length, near point of convergence and accommodative near point were measured and compared a total of 3 times at the baseline, after 1-month and after 6-months. Results: For refractive error, suppression and mitigation were seen in the progression of spherical equivalent when MC lens was worn, as compared to using SV lens, and, when axial length MC lens was worn, the axial progression was significantly suppressed and delayed (p < 0.05). The near point of convergence became shorter with the use of MC lens, and the amplitude of convergence was improved when MC lens was worn. Accommodative near point became shorter with the use of MC lens, and focus ability was significantly improved (p <0.05). Conclusions: It was shown that MC lens, compared to SV lens, could alleviate myopia progression in school-age children and youth. It is considered that MC lens can be used as a useful therapy for the inhibition of myopia progression in the increasing number of myopic children and adolescents.

Changes of Refractive Correction Value with Different Age Group: A Case for Myopia Control Lens, Single Vision Lens and Reverse Geometry Contact Lens (Myopia Control Lens, Single Vision Lens, Reverse Geometry Contact Lens의 연령에 따른 굴절교정상태 변화에 대한 추적 연구)

  • Yoon, Min-Hwa
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.75-84
    • /
    • 2013
  • Purpose: Changes of refractive correction value in different age group were investigated. Regarding the inhibitive effects against myopia progression after wearing reverse geometry contact lenses and myopia control lenses (MC lenses), the effects after wearing single vision lenses were compared. Methods: We organized children between the ages of six and fifteen into three groups by age, and distributed fifty-seven reverse geometry contact lenses, fifty-six MC lenses and seventy-eight single vision lenses among them to be worn. Group 1 consisted of children aged ten and under, Group 2 consisted of children between the ages of eleven and fifteen, and Group 3 represents all of the study participants. The aim of this study was to learn the inhibitive effects against myopia progression attained by changes of refractive correction value and to verify their statistical significance at twelve months and under, thirteen to twenty-four months and twenty-five to thirty-six months. Results: Changes of refractive correction value by each length of use in Group 3 were as follows. For the age group of under twelve months, participants using the reverse geometric contact lens showed no change, while those using the MC or single vision lens had significant changes (P<0.05) of $-0.36{\pm}0.10$ D and $-0.67{\pm}0.52$ D, respectively. Users of all three lens types displayed significant change (P<0.05), in the age group of between thirteen and twenty-four months, of $0.18{\pm}0.49$ D, $0.60{\pm}0.42$ D and $1.37{\pm}0.72$ D for users of the reverse geometry contact lens, the MC lens and the single vision lens, respectively. There were significant changes (P<0.05) of $0.29{\pm}0.61$ D, $0.93{\pm}0.57$ D and $1.72{\pm}0.78$ in the same respective order as the above in the age group of twenty-five to thirty-six months. Refractive correction value showed changes with different age group. Group 1 displayed significant changes (P<0.05) of $0.29{\pm}0.73$ D, $1.07{\pm}0.59$ D and $1.75{\pm}0.74$ D for users of the reverse geometry contact lens, MC lens and single vision lens, respectively, up to thirty-six months of lens wearing; Group 2, also up to thirty-six months, displayed significant changes (P<0.05) of $0.28{\pm}0.42$ D, $0.75{\pm}0.49$ D and $1.70{\pm}0.84$ D in the same respective order, and changes in refractive correction for the age group under ten years was significantly greater (P<0.05) for the age group of eleven and older. Conclusions: The results found in this study demonstrate that there were no changes of refractive correction value for the case of wearing reversing geometry contact lens up to twelve month or less. MC lens showed less changes in variations of visual acuity for all users which might be resulted in inhibiting progression of myoptia. When both reverse geometry contact lens and the MC lens are wearing for the period from 13 to 36 month, both lens showed less changes in variation of visual acuity for all users. The results suggested that the less changes in variation of visual acuity of both lens had an effect on inhibiting progression of myopia.

The Comparative Analysis for the Progression of Dry Eyes Caused by Wearing Soft Contact Lenses(SCL) and Cosmetic Soft Contact Lenses(C-SCL) (소프트 콘택트렌즈와 미용 콘택트렌즈의 건성안 진행에 대한 비교분석)

  • Kim, Myoung-Jin;Hwang, Hye-Kyung;Jang, Woo-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.375-381
    • /
    • 2011
  • Purpose: The purpose of this research was to see how wearing either a SCL or a C-SCL effected the dryness of a person's eye depending on how long they wear either type of lens. Methods: This study was carried out on 52 subjects (104 eyes) who were all in their twenties and had previously experienced wearing contact lenses. All of these subjects were required to wear either a SCL or a C-SCL, which were made out of the same material, for three months. Contents such as the McMonnies Questionnaire survey, the blinking rate per min. and the Noninvasive tear break-up time test (NIBUT) were later conducted on the subjects for this study. Results: According to the results of the McMonnies Questionnaire, it was concluded that the longer the subject wore the SCL and C-SCL, the value of the measurements gradually increased. On the other hand, the results from the NIBUT concluded that the longer the subject wore the SCL, the value of the measurements eventually decreased. However, according to the measurements of the blink rate test, it was concluded that neither results had a significant change. Conclusions: It was concluded that long-term wearing of SCL and C-SCL could be the cause of the induction and progression of dry eyes.

Effects of Myopia Alleviation Lenses in accordance with Parents' Refractive Errors (부모의 굴절이상에 따른 근시완화렌즈 효과)

  • Cho, Yoon Chul;Kang, JoongGu;Leem, Hyun Sung
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.569-577
    • /
    • 2018
  • Purpose : The study looked at how effective each group wearing MyoVison lens, MC lens, and Single Vision lensdepending on their parents' myopia condition. Methods : The study observed the changeof spherical equivalent among customers, who visited between January 2010 and December 2016,of an optical shop in Incheon Metropolitan City. And we observed MyoVision 152 eyes, MC Lens 86 eyes and Single Vision lens 270 eyes. This study was conducted using SPSS ver18, which analyzes the changes in average values of MyoVision, MC Lens, and Single Vision for a year.In each group, the differences in the group were compared using the Paired T-test and then one-way ANOVA (post-hoc; Bonferroni) Results : Group-to-group comparisons showed that MyoVision and MC Lens have a shorterinhibition than Single Vision. In particular, MyoVisionand MC Lens showed different relief effects depending on the degree of refraction of parents.When both parents had normal refractive, the change between MyoVision and Single Vision lens was $-0.35{\pm}0.05D$. When the father had a refraction MC lens were $-0.36{\pm}0.14D$ more effective than Single Vision. When only the mother had refraction, the mean value between MyoVision and Single Vision lens was $-0.37{\pm}0.06D$, and the mean between MC lens and Single Vision lens was $-0.38{\pm}0.08D$. And when both parents had refraction problems, the mean value change between MyoVision and Single Vision lens was $-0.28{\pm}0.07D$, and $-0.31{\pm}0.07D$, respectively. Conclusion : MyoVision and MC Lens appeared to have no effect on the functions of mitigating myopia in within group comparisons, but MyoVision and MC Lens showed reducing myopia than Single Vision in between group.

A comparative study of contact lens wearer with dry-eye patient on tear function tests (콘텐트렌즈 착용자와 건성안 환자의 눈물 검사에 대한 비교 연구)

  • Kim, Soon-Ae;Seo, Eun-Sun;Lee, Young-Hwan;Kim, Ja-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.301-312
    • /
    • 2004
  • This study was performed to compare the relationship between contact lens wearer and dry-eye patient. In this study, TBUT, SIT, TTT, Rose bengal staining and McMonnies dry eye symptom questionnaire were performed as a baseline. With the base data, the subjects were classified to 3 groups : 3S patients who have dry eye signs and symptoms, 38 patients who are wearing soft contact tenses, 35 subjects who have health eyes and never worn on a contact lenses as control subjects. Contact lens wearers were divided into 3 groups according to the duration of contact lens wear. There were no significant differences in TBUT, STT, TTT, Rose-bengal staining and McMonnies dry eye symptom questionnaire result between contact lens wearer group and dry eye patients group. We suggest that there are similarities in tear function tests between the dry-eye patient and the contact lens wearer.

  • PDF

Competitiveness Comparison between Korea and Japan in the Spectacles Industry (한국과 일본 안경산업의의 경쟁력 비교)

  • Lim, Jun-Hyeong;Hyun, Sung-Cheol
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.19-23
    • /
    • 2010
  • Purpose: The aims of this paper are to assess the competitiveness about the spectacles industry of Korea against Japan. Methods: We use export competitiveness indexes such as market share index, trade specialization index and market comparative advantage index to evaluate the competitiveness of spectacles industry of Korea against Japan. Results: This paper shows that the comparative advantage of the Spectacles industry of Korea in MC(market comparative advantage) against Japan arc spectacles lenses and contact lenses. Furthermore, it can also be known that the spectacles lenses and contact lenses have export competitiveness in the TSI (trade specialization index) against Japan. Conclusions: We need to choose spectacles lenses and contacts lenses as the main export items against Japan in the spectacles industry of Korea. Along with this, we need to improve the image of the Spectacles industry in Korea; after that, we have to create a strategy that would strengthen export competition in other items.

Improvement of color mixing in an RGB lamp using tilled lenses (경사렌즈를 사용한 RGB LED전구 색혼합 향상)

  • 강석훈;임성무;송상빈;여인선
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.8-15
    • /
    • 2004
  • This paper presents a method of improvement of color mixing in an RGB LED white lamp. The deviation from white light after RGB color mixing results mainly from the difference in the ray direction among LEDs. The authors propose a method using tilted lenses covered over each LED to deflect the overall direction of the ray generated from far-sited LEDs toward the center axis of the lamp. The degree of improvement is evaulated using a color discrimination method based on McAdam ellipse.

Improvement of color mixing in an RGB lamp using tilted lenses (경사 렌즈를 사용한 RGB LED 전구 색혼합 향상)

  • Kang, Seok-Hoon;Song, Sang-Bin;Yeo, In-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.145-147
    • /
    • 2003
  • This paper presents a method of improvement of color mixing in an RGB LED white lamp. The deviation from white light after RGB color mixing results mainly from the difference in the ray direction among LEDs. The authors propose a method using tilted lenses covered over each LED to deflect the overall direction of the ray generated from far-sited LEDs toward the center axis of the lamp. The degree of improvement is evaluated using a color discrimination method based on McAdam ellipse.

  • PDF

Thermographic Assessment in Dry Eye Syndrome, Compared with Normal Eyes by Using Thermography (열화상카메라를 이용한 정상안과 건성안의 서모그래피 비교)

  • Park, Chang Won;Lee, Ok Jin;Lee, Seung Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.247-253
    • /
    • 2015
  • Purpose: The purpose of this study was to compare and analyze the ocular surface and the palpebral conjunctiva of categorized subjects, which were divided into normal eye group and dry eye group, by using a thermal camera. Methods: Subjects were 144 eyes of 72 normal university students, who didn't have any corneal disease, abnormal lacrimal ducts, medical records regarding ocular surgeries, or experience of using contact lens. Subjects were divided into two groups, which were normal eye group and dry eye group, based on the results of TBUT, Schirmer I test, and McMonnies test. After categorizing the subjects, the temperature of the subjects' ocular surface and the palpebral conjunctiva were measured and analyzed by using a thermal camera (Cox CX series, Answer co., Korea). Results: In the normal eye group's Central Ar.1, Nasal Ar.2, Temporal Ar.3, Superior Ar.4, Inferior Ar.5, the measured amount of temperature change on each area was $-0.13{\pm}0.08$, $-0.14{\pm}0.08$, $-0.12{\pm}0.08$, $-0.14{\pm}0.08$, $-0.10{\pm}0.09(^{\circ}C/sec)$. The dry eye group's results were $-0.17{\pm}0.08$, $-0.16{\pm}0.07$, $-0.16{\pm}0.08$, $-0.17{\pm}0.09$, $-0.15{\pm}0.08(^{\circ}C/sec)$. When compared with the normal eye group, the values of Ar.1, Ar.3, Ar.5 were significantly different in the dry eye group(p<0.05). The amount of temperature change, which was observed on the palpebral conjunctiva(Ar.1:central, Ar.2: nasal, Ar.3: temporal) of the normal eyes, measured by thermography, was $34.36{\pm}1.12$, $34.17{\pm}1.10$, $34.07{\pm}1.12^{\circ}C$ on each area. Same values taken from the dry eye group was $33.55{\pm}0.94$, $33.43{\pm}0.97$, $33.51{\pm}1.06^{\circ}C$ on each area. The values of Ar.1, taken from the dry eye group, had a significant difference, compared to the values of the normal eye group(p=0.05). Conclusion: The temperature of the ocular surface decreased faster on the dry eyes, compared to the normal eyes. The temperature measured on the palpebral conjunctiva of the dry eyes were also lower than the normal eyes. The temperature changes on the ocular surface, observed with a thermal camera, were objective values to assess the stability of tear films, and might provide useful data for studies related to dry eye syndrome.

The Influence of Office Indoor Air Qualitys on the Dry Eye Symptom of Contact Lens Wearers (사무실 실내공기질과 콘택트렌즈 착용여부가 안구 건조증에 미치는 영향)

  • Kim, Dea Jong;Park, Moon Chan;Lee, Se Hoon;Kim, Hyun Uk;Lee, Wha Ja;Cha, Jung Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.215-222
    • /
    • 2012
  • Purpose: This study was performed to investigate the influence of indoor air qualities of an office environment on dry eye syndrome for wearing contact lens and non-wearing contact lens. Methods: To study the effects of indoor air qualities on dry eye syndrome for seventy-one subjects, $CO_2$, temperature, humidity, TSP, PM10, HCHO were measured. Each subject was tested by a McMonnie's dry eye syndrome questionnaire, a Schirmer Tear Test-I (S.T.T-I), a Schirmer Tear Test-II with anesthetics (S.T.T-II), and Tear film break-up time (T.B.U.T) in the their offices. Results: There was significant relation between the indoor air quality and dry eye syndrome for wearing contact lens and non-wearing when TSP was over $200{\mu}g/m^3$, PM10 was higher than $86.7{\mu}g/m^3$ and Formaldehyde was over $0.4{\sim}1.0{\mu}g/m^3$. However, there was no significant effect on dry eye syndrome with $CO_2$ (p=.0146), temperature (p=0.074) and humidity (p=0.053). Conclusions: It was indicated that $CO_2$, temperature and humidity were no effect on dry eye syndrome in the office environment. However TSP, PM10, formaldehyde, and wearing contact lens were effect on dry eye syndrome. Therefore, the entire management of wearing contact lens and the individual evaluation of the indoor air quality are required.