• Title/Summary/Keyword: MAXIMUM PRESSURE

Search Result 3,765, Processing Time 0.029 seconds

Estimation of Erosion Damage of Armor Units of Rubble Mound Breakwaters Attacked by Typhoons (태풍에 의한 경사식 방파제의 피복재 침식 피해 산정)

  • Kim, Seung-Woo;Suh, Kyung-Duck
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.5
    • /
    • pp.295-305
    • /
    • 2010
  • Although the rubble mound breakwaters in Korea have been damaged by typhoons almost every year, quantification of erosion of armor block have seldomly been made. In this paper, the damage of armor units is standardized by the relative damage. In the case where the number of damaged units is reported, it is divided by the total number of units to calculate the relative damage. In the case where the rehabilitation cost is reported, the relative damage is calculated by using its relationship with the present value of the past rehabilitation cost. The relative damage is shown to have strong correlations with the typhoon parameters such as nearest central air pressure and maximum wind speed at each site. On the other hand, the existing numerical methods for calculating the cumulative damage are compared with hydraulic model tests. The method of Melby and Kobayashi (1998) is shown to give a reasonable result, and it is used to calculate the relative damage, which is compared with the measured damage. A good agreement is shown for the East Breakwater of Yeosu Harbor, while poor agreement is shown for other breakwaters. The poor agreement may be because waves of larger height than the design height occurred due to strong typhoons associated with climate change so that the relative damage increased during the last several decades.

A Numerical Study on the Geometry Optimization of Internal Flow Passage in the Common-rail Diesel Injector for Improving Injection Performance (커먼레일 디젤인젝터의 분사성능 개선을 위한 내부유로형상 최적화에 관한 수치적 연구)

  • Moon, Seongjoon;Jeong, Soojin;Lee, Sangin;Kim, Taehun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.2
    • /
    • pp.91-99
    • /
    • 2014
  • The common-rail injectors are the most critical component of the CRDI diesel engines that dominantly affect engine performances through high pressure injection with exact control. Thus, from now on the advanced combustion technologies for common-rail diesel injection engine require high performance fuel injectors. Accordingly, the previous studies on the numerical and experimental analysis of the diesel injector have focused on a optimum geometry to induce proper injection rate. In this study, computational predictions of performance of the diesel injector have been performed to evaluate internal flow characteristics for various needle lift and the spray pattern at the nozzle exit. To our knowledge, three-dimensional computational fluid dynamics (CFD) model of the internal flow passage of an entire injector duct including injection and return routes has never been studied. In this study, major design parameters concerning internal routes in the injector are optimized by using a CFD analysis and Response Surface Method (RSM). The computational prediction of the internal flow characteristics of the common-rail diesel injector was carried out by using STAR-CCM+7.06 code. In this work, computations were carried out under the assumption that the internal flow passage is a steady-state condition at the maximum needle lift. The design parameters are optimized by using the L16 orthogonal array and polynomial regression, local-approximation characteristics of RSM. Meanwhile, the optimum values are confirmed to be valid in 95% confidence and 5% significance level through analysis of variance (ANOVA). In addition, optimal design and prototype design were confirmed by calculating the injection quantities, resulting in the improvement of the injection performance by more than 54%.

A Study on the Methanation of Carbon Dioxide over Ni/Y-type Zeolites (Y형 제올라이트 담지 니켈촉매상에서 이산화탄소의 메탄화반응)

  • Lee, Kwan-Yong;Kim, Hyung-Wook;Kim, Geon-Joong;Ahn, Wha-Seung
    • Applied Chemistry for Engineering
    • /
    • v.4 no.2
    • /
    • pp.365-372
    • /
    • 1993
  • $CO_2$ methanation was performed over Ni supported on cation-exchanged Y zeolites under atmospheric pressure at $250{\sim}550^{\circ}C$ and $H_2/CO_2$ mole ratio of 4. Adsorption strength between carbon dioxide and nickel was found to be Influenced by the cation exchanged in the zeolite. TPD(Temperature-programmed desorption) results show that the adsorption strength decreases in the order of Ni/NaY>Ni/MaY>Ni/HY. TPSR(Temperature-programmed surface reaction) results indicate that enhanced methanation activity is obtained when the adsorption strength between carbon dioxide and nickel is stroing. As the reduction temperature increases, the methantion activity of the catalyst increase. From this result the larger size nickel particle seems advantageous for $CO_2$ methanation reaction. The maximum activity is obtained when nickel loading is 3.3wt%. Carbon monoxide is produced as a by-product throughout the reaction temperature range, and as the contact time increases, the selectivity to methane increases and the selectivity to carbon monoxide decreases steadily. Thus methane seems to be produced from $CO_2$ via CO as an intermediate species. In the temperature range of $410{\sim}450^{\circ}C$, the methane production rate is found to be dependent on the orders of 3.3~-0.5 and 1.4~3.6 with respect to $CO_2$ and $H_2$ partial pressures, respectively. This clearly shows that $CO_2$ and $H_2$ are competing for adsorption sites and as the reaction temperature increases, it becomes increasingly difficult for $H_2$ to be adsorbed on the catalyst surface.

  • PDF

Study on Performance and Analysis of PF Heat Exchanger for Heat Pump Dryer (히트펌프 건조기용 PF 열교환기 성능 및 해석 연구)

  • Kim, Ki-Young;Lee, Seok-Hyun;Kwon, Young-Chul;Chun, Chong-Keun;Park, Sam-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1576-1581
    • /
    • 2013
  • In the present study, the performance of a PF heat exchanger for heat pump dryer was investigated. Capacity and dehumidification amount of the PF heat exchangers(PF1, PF2, PF3) by different inclination angles($0^{\circ}$, $30^{\circ}$, $60^{\circ}$) were studied. Experimental conditions were an air velocity crossing to the heat exchanger(0.5m/s), an air dry-bulb temperature($60^{\circ}C$) and relative humidity(70%). The experimental results have shown that the performance of the inclined PF heat exchangers was better than that of the vertically installed one. PF3 showed better performance compared to PF1 and PF2 due to the large pin pitch which are leading to more draining for dehumidified water. But, capacity and dehumidification amount of the PF heat exchanger at the inclination angles of $60^{\circ}$ was decreased due to pressure drop. Also, to predict the experimental data of the PF heat exchanger, the performance program was developed for the inclination angles of $0^{\circ}$. PF heat exchanger performance between experiment data and calculation data was satisfied within the maximum 2% for capacity and 3% for dehumidification amount.

Tc-99m-DAPA Pulmonary Clearance in Normals (정상성인에서의 Tc-99m-DTPA 폐제거율)

  • Chung, Soo-Kyo;Yang, Woo-Jin;Sohn, Hyung-Sun;Shinn, Kyung-Sub;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.338-342
    • /
    • 1994
  • Pulmonary clearance of Tc-99m-DTPA(PCD) has been used for the measurement of polmonary epithelial permeability. It has been reported to be increased not only in variety of polmonary diseases including ARDS, interstitial fibrosis, and smokers, but also in normal subjects on positive end expiratory pressure respirator, or after exercise. It was also noted that decrease of pulmonary blood flow due to pulmonary arterial obstruction results in delayed PCD. Normal range of PCD varies with institutes. We prospectively measured PCD in 17 normals (5 males and 12 females) consisted of staffs and trainees in the department of radiology of Kangnam St. Mary's hospital using original Bark Nebulizer (India). Age ranged from 32 to 43 years. 370 MBq of Tc-99m-DTPA was inhaled in supine position and supine posterior images were subsequently obtained with 1 min/frame, $64{\times}64$ matrix and word mode for 30min. Regions of interest were set on each lung, whole lungs, and upper, middle and lower thirds of right lung, respectively. Best fit regression curve was obtained by least square method from initial 7min after peak activity on each curve and time for half clearance of maximum activity (t1/2) was calculated. Mean t1/2 was $51{\pm}11.2min$ for whole lung. There was no significant difference between t1/ 2 of right and left lungs. Initial uptake was higher in the lower third and t1/2 was shorter in the lower third than in the upper third(P<0.05). We reviewed several reports on PCD and compared our data with the others. In this study, faster clearance in the lower third may be due to the position imaged with or the environment the subjects belong to, and further investigation is under way.

  • PDF

Fabrication and Characteristics of a White Emission Electroluminicent Device (백색 전계발광소자의 제작과 그 특성)

  • Kim, Woo-Hyun;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.295-303
    • /
    • 2001
  • White emission thin film electroluminecent device was fabricated with ZnS for phosphor layers and BST ferroelectric thin film for insulating layers. The ZnS:Mn and $ZnS:SmF_3$ layers were used for emission of red color. Also the $ZnS:TbF_3$ and $ZnS:AgF_3$ layers were used to emission of green and blue color, respectively. And the fabrication conditions of the BST insulating layers were followings, that is, the composition ratio of target, substrate temperature, working pressure and operating gas ratio were $Ba_{0.5}Sr_{0.5}Ti_{0.3}$, $400^{\circ}C$, 30 mTorr and 9:1, respectively. The thickness of phosphor were 150 nm for each layers and the insulating layers of upper and bottom were 400 nm and 200 nm, respectively. The luminesence threshold voltage was $75\;V_{rms}$ and the maximum brightness of the thin film electroluminecent device was $3200\;cd/m^2$ at $100\;V_{rms}$.

  • PDF

Characteristics of TMA Gas Detection of a ZnO Thin Films by Annealing (열처리에 따른 ZnO 박막의 TMA 가스 검지 특성)

  • Ryu, Jee-Youl;Park, Sung-Hyun;Choi, Hyek-Hwan;Kwon, Tae-Ha
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.30-36
    • /
    • 1996
  • ZnO thin-film sensors were fabricated by RF magnetron sputtering method. The composition of the device material was 4 wt. % $Al_{2}O_{3}$, 1 wt. % $TiO_{2}$ and 0.2 wt. % $V_{2}O_{5}$ on the basis of ZnO material for developing the high sensitive TMA gas sensor which have an appropriate resistivity and the stability for practical use. They were also grown on the $SiO_{2}/Si$ substrates heated at $250^{\circ}C$ under a pure oxygen pressure of about 10 mTorr with a power of about 80 watts for 10 minutes. So as to enhance the stability of the resistivity, the thin films were annealed from $400^{\circ}C$ to $800^{\circ}C$. The sensors made with the thin film which were annealed at $700^{\circ}C$ for 60 minutes in pure oxygen gas exhibited a good sensing properties for TMA gas. The thin film grown at this condition showed the maximum sensitivity of 550 in TMA gas concentration of 160 ppm, and exhibited a good stability and excellent linearity.

  • PDF

The Methodology for Prediction and Control of Hazardous Chlorine Gas Flow Releases as Meteorological Data (기상조건에 따른 유해독성염소가스의 가상흐름누출에 관한 예측 및 제어론)

  • Kim, Jong-Shik;Park, Jong-Kyu
    • Applied Chemistry for Engineering
    • /
    • v.10 no.8
    • /
    • pp.1155-1160
    • /
    • 1999
  • The screening methodology modeling, dispersion modeling procedures for continuous and instantaneous releases of the gas phase flow from the storage tank and pressure relief valve were considered. This study was performed to develop the screening methodology for prediction and control of hazardous/toxic gas releases by estimating the 1-hr average maximum ground-level concentration of $Cl_2$ gas vs. downwind distance by incorporating source term model including the general/physical properties of released material and release mode of the $Cl_2$ storage tank of the chemical plant facilities, dispersion model, and meteorological/topographical data into the TSCREEN model. As the results of the study, it was found that dispersion modes of the dense gas were affected by the state of the released material, the released conditions, physical-chemical properties of released material, and the released modes (continuous and instantaneous releases), and especially largely affected by initial (depressurized) density of the released material and release emission rate as well as the wind velocity. Especially, this study was considered to release hazardous material as meteorological data. It was thought that this screening methodology can be useful as a preliminary guideline for application of the refined analysis model by developing the generic sliding scale methodology for various senarios selected.

  • PDF

Performance Evaluation of Balance Ability Equipment Using VR (VR을 이용한 균형능력 측정장비의 성능평가)

  • Yoon, Sangcheol;An, Howon;Ahn, Taekwon;Choi, Haesung;Lee, Byoungkwon;Seo, Dongkwon;Lee, Kyuhwan;Jung, Sangwoo;Yi, Jaehoon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.33-41
    • /
    • 2020
  • Purpose : Conventional Balance Measurement can only measure the center of gravity and the shaking movement of the body. As a result, it has the disadvantages of not responding to visual changes and blocking functions of variables. This study was carried out to evaluate the performance of new equipment that measures the balance of the body using changes in body segment and pressure using the acceleration sensor to compensate for the disadvantages of the existing equipment. Methods : To this end, balance ability was measured in 43 healthy male/female adults without orthopedic injuries and nervous system damage in the last 6 months. in a situation where the visual information was restricted by Virtual Reality (VR) gear, all subjects measured and evaluated the balance ability utilizing the new equipment. Balance measurement (Prime Medilab, Korea) and Wii fit (Nintendo, Japan) were used to measure the balance ability of the subjects, and the balance ability test was performed in 4 postures using each device for data acquisition. The test duration for each posture was 30 seconds. For data acquisition, the average value of three experiments measured using each equipment was analyzed, and the statistical test was performed using the independent sample and the corresponding sample t-test, and the significance level was set to α=.05. Results : As a result of measuring the balance ability using individual equipment, blocking visual information using VR gear, the average speed, maximum speed, and moving area of the COP increased equally. It was found that the obtained absolute size of the result in Wii was somewhat larger than that of BM. Conclusion : It is considered that in the future research, it is necessary to measure changes in the body's center of gravity through image analysis, etc., to make clear comparison and evaluation of the usability.

Aerodynamic Features and Voice Therapy Interventions of Functional Voice Disorder after Thyroidectomy (갑상선 절제 술 후 기능적 음성장애의 공기역학적 특징과 음성치료 중재)

  • Lee, Chang-Yoon;An, Soo-Youn;Chang, Hyun;Jeong, Hee Seok;Son, Hee Young
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.26 no.1
    • /
    • pp.25-33
    • /
    • 2015
  • Background and Objectives:The objective of this study was to investigate the features of post-thyroidectomy subjective voice disorder by Voice Handicap Index (VHI) and Voice Symptom Scale (VOISS) through aerodynamic analysis and to investigate the appropriate voice therapy intervention. Materials and Methods:Twenty post-thyroidectomy patients who had no recurrent laryngeal nerve paralysis through laryngeal stroboscopy were enrolled for this study. Acoustic and aerodynamic evaluations were performed before operation, 2 weeks and 3 months after operation. Subjective voice evaluation was performed by VHI and VOISS. Aerodynamic evaluation was compared and analysed by maximum phonation time(MPT), phonation threshold pressure(PTP), mean air flow rate(MFR), etc. Subjective voice evaluation was surveyed through VHI and VOISS. To evaluate patients' symptoms related to functional voice disorder, scores on physical domain in VHI and VOISS were selected to be compared for each session. Results: The 10 out of 20 participants who complained of voice symptoms had no significant difference with pre-operation in acoustic evaluation, but all showed higher scores on 2 weeks and 3 months after operation compared to pre-operation, in VHI-physical domain and selected questionnaires in VOISS. They reduced MPT and increased PTP value simultaneously. Laryngeal massage and breathing training were simultaneously treated to them, 5 participants resulting in improvement in MPT and PTP compared to pre-treatment. Conclusion:Patients who complained voice change with no organic damage after thyroidectomy were all shown to have reduced MPT and increased PTP in some by aerodynamic evaluations. Reduced MPT may imply some problem in air flow beneath glottis. Increased PTP suggests much more effort in vocalization mechanism than pre-operation. Comparing aerodynamic evaluations in post-thyroidectomy may provide information on behavioral interventions. Additionally, study on laryngeal massage and breathing training simultaneously treated to patients with such voice disorder is needed to be conducted with larger number of participants.

  • PDF