• Title/Summary/Keyword: MASS LOSS RATE

Search Result 400, Processing Time 0.031 seconds

Physical and Chemical Characteristics of Sediments at Bam Islands in Seoul, Korea

  • Han, Mie-Hie;Kim, Jae-Geun
    • Journal of Ecology and Environment
    • /
    • v.29 no.4
    • /
    • pp.389-398
    • /
    • 2006
  • To examine sediment characteristics and find anthropogenic effects on riverine wetland ecosystems, paleoecological study was carried out at Bam islands in Seoul. Three hundred cm deep sediment cores were retrieved and dated with the lamination analysis method until 36 cm depth (1986). Sediments were divided into three zones based on the depth profiles of physico-chemical variables: below 160 cm depth (before 1968), between 160 and 40cm depths and above 40cm depth (after 1986). Physico-chemical characteristics were very variable between 160 and 40cm depths and this indicates unstable sedimentation environment. Even though heavy metal concentrations were relatively low, Cd and As contents have increased continuously. Dry mass accumulation rates during $1968{\sim}1986\;and\;1987{\sim}2003$ were 140 and $21\;kg\;m^{-2}\;yr^{-1}$, respectively. This was related to flooding intensity and duration. Bulk density, water content, loss on ignition, N, C, C/N ratio were very similar to other river delta but Ca, Na and K contents were 2 to 4 times higher than others. Heavy metal contents except Pb were lower or similar to those in other studied marshes in Korea. Heavy metal and Mg contents were correlated with each other and this suggests that the source of heavy metals be parent rock. From $^{13}C$ dating dates of organic materials in sediment, it is suggested that organic matter originated from the watershed and flooding intensity in the watershed might be responsible for the source of sediments. This study provides reference data for the comparison of sediment characteristics at islands in river and for the management of Bam islands.

Effect of Hydrophilic Polymers on the Release of BCNU from BCNU-loaded PLGA Wafer (친수성 고분자가 BCNU 함유 PLGA 웨이퍼로부터 BCNU의 방출에 미치는 효과)

  • 안태군;강희정;문대식;이진수;성하수
    • Polymer(Korea)
    • /
    • v.26 no.5
    • /
    • pp.670-679
    • /
    • 2002
  • 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU, carmustine) is one of the effective chemotherapeutic agents which has been used clinically for treating malignant glioma. Poly(D,L-lactide-co-glycolide) (PLGA, molecular weight: 20000 g/mole. mole ratio of lactide to glycolide 75 : 15) is a well known biodegradable polymer used as a drug carrier for drug delivery system. In this study, we investigated the BCNU release behaviour of BCNU-loaded PLGA wafers containing poly (N-vinylpyrrolidone) (PVP) or polyethyleneoxide (PEO) and the effect of hydrophilic polymers incoporated in the wafers. BCNU-loaded PLGA microparticles with or without hydrophilic polymers were prepared by a spray drying method and fabricated into wafers by direct compression. Encapsulation efficiency of BCNU-loaded PLGA microparticles containing PVP and PEO was 85 ∼ 97% and crystallinity of BCNU encapsulated in PLGA decreased significantly initial release amount and release rate of BCNU increased with the increasing PVP or PEO amount. Morphological change and mass loss of wafers during the release test were confirmed that hydration and degradation of PLGA would be facilitated with an increase of hydrophilic polymers.

Study on Experimental and Theroretical performances for a Compact Metallic Heat Exchanger for Fuel Cell Systems (연료전지용 소형 금속 열교환기의 성능에 대한 실험 및 이론적 연구)

  • Yoon, Young-Hwan;Paeng, Jin-Gi
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.9-18
    • /
    • 2011
  • This study assessed the performance of a compact heat exchanger with staggered tube banks for recuperation of high temperature exhaust thermal energy for SOFC fuel cell system. The compact heat exchanger in this study is two pass system which consists of $315{\times}202.5{\times}48.5mm^3$ and 132 tubes of $6.0mm{\Phi}$ for each heat exchanger. From experiments of the 2 pass heat exchanger system, air temperature was increased from $60{\sim}85^{\circ}C$ to $402{\sim}482^{\circ}C$ while gas temperature was decreased from $600^{\circ}C$ to $305{\sim}402^{\circ}C$ according to mass flow rates of 3.9~7.8 g/s. The experimental heat transfer rates of the heat exchanger were compared with CFD numerical solutions with the conventional ${\xi}-NTU$ method. From the comparisons, the following conclusions were obtained. For the heat exchanger system, the relative errors of heat transfer rate by CFD solution were from 7.1 to 27%, and those by ${\xi}-NTU$ method were from 0.6% to 21% compared with experimental data. From the comparisons, it can be said that both of CFD and ${\xi}-NTU$ method almost simulated to experimental data except specific conditions. Pressure drops through air tubes and gas passages were calculated with both of the CFD computation and head loss equations. The differences between them were from 14 to 22%.

A Study on the Maternal Characteristics and Clinical Changes After Korean Medicine Postpartum Care - A Comparative Study with Pre-Study in 2010 - (한방 산후조리 이용 산모의 특성과 치료결과 보고 - 2010년 선행 연구와의 비교 고찰 -)

  • Noh, Eun-Ji;Choi, Su-Ji;Lee, Dong-Nyung;Kim, Dong-Il
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.32 no.3
    • /
    • pp.57-72
    • /
    • 2019
  • Objectives: This study aims to assess the maternal characteristics and changes of body among patients who received Korean medicine postpartum care compared to pre-study. Methods: From January 1, 2018 to February 28, 2019, we included 31 postpartum patients who had body composition analysis at admission and discharge among 34 patients who received postpartum care in ${\square}{\square}$ University Hospital. We used SPSS 21.0 for window to test for statistical significance. Results: The average age, weight, and caesarean section rate increased compared to previous study. The average period of postpartum care has decreased. After postpartum care, abdominal circumference, body weight and Body Mass Index (BMI) was significantly decreased, but not as much as pre-study. The coefficient of determination was derived to predict the effects of postpartum care and calculated as "$Abdominal\;circumference\;change=2.745+0.593{\times}admission\;period$", "$weight\;change=0.214+0.345{\times}admission\;period$" and "$BMI\;change=0.198+0.120{\times}admission\;period$". Conclusions: Compared to previous study, as the maternal age increased and admission period decreased, the weight loss after childbirth decreased. It is necessary to provide individual treatment through coefficient of determination.

Accretion Flow and Raman-scattered O VI and C II Features in the Symbiotic Nova RR Telescopii

  • Heo, Jeong-Eun;Lee, Hee-Won;Angeloni, Rodolfo;Palma, Tali;Di Mille, Francesco
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.39.2-39.2
    • /
    • 2018
  • RR Tel is an interacting binary system in which a hot white dwarf (WD) accretes matter from a Mira variable via gravitational capture of the stellar wind. We present a high-resolution optical spectrum of RR Tel obtained with MIKE at Magellan-Clay telescope, Chile. We find broad emission features at 6825, 7082, 7023, and $7053{\AA}$, which are formed through Raman scattering of far-UV O VI ${\lambda}{\lambda}$ 1032 and $1038{\AA}$, C II ${\lambda}{\lambda}$ 1036 and $1037{\AA}$ with atomic hydrogen. Raman O VI 6825 and 7082 features are characterized by double-peaked profiles indicative of an accretion flow with a characteristic speed ~ 30km/s, whereas the Raman C II features exhibit a single Gaussian profile with FWHM ${\sim}10{\AA}$. Monte Carlo simulations for Raman O VI and C II are performed by assuming that the emission nebula around the WD consists of the inner O VI disk with a representative scale of 1 AU and the outer part with C II sphere. The best fit for Raman profiles is obtained with an asymmetric matter distribution of the O VI disk, the mass loss rate of the cool companion ${\dot{M}}{\sim}2{\times}10^{-6}M_{{\odot}/yr}$ and the wind terminal velocity v~10 km/s. We also find O VI doublet at 3811 and $3834{\AA}$, which are blended with other emission lines. Our profile decomposition shows that the O VI ${\lambda}{\lambda}$ 3811, 3834 doublet have a single Gaussian profile with a width ~ 25 km/s. A comparison of the restored fluxes of C II ${\lambda}{\lambda}$ 1036 and 1037 from Raman C II features with the observed C II ${\lambda}1335$ leads to an estimate of a lower bound of N(CII) > $9.87{\times}10^{13}cm^{-2}$ toward RR Tel, which appears consistent with the presumed distance D ~ 2.6 kpc.

  • PDF

D2 Lymph Node Dissections during Reduced-port Robotic Distal Subtotal Gastrectomy and Conventional Laparoscopic Surgery Performed by a Single Surgeon in a High-volume Center: a Propensity Score-matched Analysis

  • Song, Jeong Ho;Son, Taeil;Lee, Sejin;Choi, Seohee;Cho, Minah;Kim, Yoo Min;Kim, Hyoung-Il;Hyung, Woo Jin
    • Journal of Gastric Cancer
    • /
    • v.20 no.4
    • /
    • pp.431-441
    • /
    • 2020
  • Purpose: Various studies have indicated that reduced-port robotic gastrectomies are safe and feasible for treating patients with early gastric cancer. However, there have not been any comparative studies conducted that have evaluated patients with clinically advanced gastric cancer. Therefore, we aimed to compare the perioperative outcomes of D2 lymph node dissections during reduced-port robotic distal subtotal gastrectomies (RRDGs) and conventional 5-port laparoscopic distal subtotal gastrectomies (CLDGs). Materials and Methods: We retrospectively evaluated 118 patients with clinically advanced gastric cancer who underwent minimally invasive distal subtotal gastrectomies with D2 lymph node dissections between February 2016 and November 2019. To evaluate the patient data, we performed a 1:1 propensity score matching (PSM) according to age, sex, body mass index, American Society of Anesthesiologists physical status classification score, and clinical T status. The short-term surgical outcomes were also compared between the two groups. Results: The PSM identified 40 pairs of patients who underwent RRDG or CLDG. The RRDG group experienced a significantly longer operation time than the CLDG group (P<0.001), although the RRDG group had significantly less estimated blood loss (P=0.034). The number of retrieved extraperigastric lymph nodes in the RRDG group was significantly higher than that of the CLDG group (P=0.008). The rate of postoperative complications was not significantly different between the two groups (P=0.115). Conclusions: D2 lymph node dissections can be safely performed during RRDGs and the perioperative outcomes appear to be comparable to those of conventional laparoscopic surgeries. Further studies are needed to compare long-term survival outcomes.

Effect of Blood Flow Restriction Resistance Exercise in Twenties on Biceps Activity, Fatigue and Hemodynamic Variables (20대의 혈류제한 저항운동이 위팔두갈래근 활성도, 피로도 및 혈역학적 변인에 미치는 영향)

  • Dae-Keun Jeong;Jeong-Il Kang;Jun-Su Park
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.18 no.1
    • /
    • pp.15-24
    • /
    • 2023
  • PURPOSE: This study examined the effects of lowintensity resistance exercise combined with blood flow restriction on muscle activity and muscle fatigue to determine if such a combination may be an alternative to high-intensity resistance exercise in maintaining the muscle mass and strength and preventing degenerative loss of skeletal muscle and to provide basic data for presenting the effectiveness of exercise. METHODS: The interventions were provided for five weeks, four sessions a week, once a day, 60 minutes a session to Experimental group I (n = 13), in which low-intensity resistance exercise was applied by combining blood flow restriction with the biceps curl and experimental group II (n = 12), in which only high-intensity resistance exercise was applied. As a pre-test, the biceps brachii muscle activity and fatigue were measured by surface electromyography, and the hemodynamic variables, such as blood pressure and heart rate, were measured. The post-test was performed identically to the pre-test and compared and analyzed with the pre-test. RESULTS: A significant difference within-group was observed in the biceps brachii muscle activity and fatigue in experimental group I and only in biceps brachii activity in experimental group II. No significant differences were observed between the two groups. CONCLUSION: Since the low-intensity resistance exercise combined with blood flow restriction has similar effects to high-intensity resistance exercise, it is considered an alternative for improving muscle function in groups unable to perform high-intensity resistance exercise.

Early Diagnosis and Treatment Strategies of Obesity Hypoventilation Syndrome (비만성 저환기 증후군의 조기 진단 및 치료 전략)

  • Hwan Hee Kim;Sang Haak Lee;Sei Won Kim
    • Sleep Medicine and Psychophysiology
    • /
    • v.29 no.1
    • /
    • pp.4-8
    • /
    • 2022
  • Obesity hypoventilation syndrome (OHS) is defined as the triad of obesity (body mass index, [BMI] ≥ 30 kg/m2), daytime hypercapnia (PaCO2 ≥ 45 mm Hg), and sleep breathing disorder, after excluding other causes for hypoventilation. As the obese population increases worldwide, the prevalence of OHS is also on the rise. Patients with OHS have poor quality of life, high risk of frequent hospitalization and increased cardiopulmonary mortality. However, most patients with OHS remain undiagnosed and untreated. The diagnosis typically occurs during the 5th and 6th decades of life and frequently first diagnosed in emergency rooms as a result of acute-on-chronic hypercapnic respiratory failure. Due to the high mortality rate in patients with OHS who do not receive treatment or have developed respiratory failure, early recognition and effective treatment is essential for improving outcomes. Positive airway pressure (PAP) therapy including continuous PAP (CPAP) or noninvasive ventilation (NIV) is the primary management option for OHS. Changes in lifestyle, rehabilitation program, weight loss and bariatric surgery should be also considered.

Mechanical and Electrical Properties of Low-Cement Mortar Using a Large Amount of Industrial By-Products (산업부산물을 다량활용한 저시멘트 모르타르의 역학적·전기적 특성)

  • Kim, Young-Min;Im, Geon-Woo;Lim, Chang-Min;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.43-44
    • /
    • 2023
  • This study evaluated the mechanical and electrical properties of low-cement mortar using a large amount of industrial by-products to reduce carbon emissions from the cement industry. As types of industrial by-products, blast furnace slag and fly ash, which are representative materials, were used, and ultra-high fly ash was mixed and evaluated to solve the problem of initial strength loss. In addition, in order to evaluate the electrical properties, 1% of MWCNT was incorporated relative to the powder mass. As experimental items, the compressive strength was measured on the 1st, 3rd, 7th and 28th days of age, and the rate of change in electrical resistance was measured on the 28th day of age. As a result of the experiment, the initial strength of the test specimen mixed with blast furnace slag and fly ash was significantly lower than that of 100% cement, and the specimen mixed with blast furnace slag showed strength equal to that of cement at 28 days of age. As an electrical characteristic, the electrical resistance was reduced when the load was loaded, and this reason is judged to be the effect of improving the conductivity as the connection between CNTs is narrowed by the compressive load.

  • PDF

A Study on Corrosion Potential of Cracked Concrete Beam According to Corrosion Resistance Assessment (부식 저항성 평가에 따른 균열 콘크리트 보의 부식전위 연구)

  • Song, Ha-Won;Lee, Chang-Hong;Lee, Kewn-Chu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.1 s.53
    • /
    • pp.97-105
    • /
    • 2009
  • Development and use of blended cement concrete is gaining more importance in the construction industry with reference to durability mainly due to the pore refinement and reduction in permeability. Cracks play a major role on important parameters like permeability, rate of chloride ingress, compressive strength and thus affect the reinforcement corrosion protection. Furthermore, when a crack occurs in the cover concrete, the corrosion of the steel reinforcement may be accelerated because the deterioration causing factors can pass through the crack. In recent years the effect of cracking on the penetration of concrete has been the subject of numerous investigations. Therefore assessing the service life using blended concrete becomes obviously in considering the durability. In the present study, the corrosion assessment of composite concrete beams with and without crack with of 0.3mm using OPC, 30% PFA, 60% GGBS, 10% SF was performed using half cell potential measurement, galvanic potential measurement, mass loss of steel over a period of 60days under marine environmental conditions and the results were discussed in detail.