• Title/Summary/Keyword: M2M application

Search Result 5,300, Processing Time 0.032 seconds

The Design of GF(2m) Parallel Multiplier using data select methodology (데이터 선택방식에 의한 GF(2m)상의 병렬 승산기 설계)

  • Byun, Gi-Young;Choi, Young-Hee;Kim, Heong-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.2A
    • /
    • pp.102-109
    • /
    • 2003
  • In this paper, the new multiplicative algorithm using standard basis over GF(2m) is proposed. The multiplicative process is simplified by data select method in proposed algorithm. After multiplicative operation, the terms of degree greater than m can be expressed as a polynomial of standard basis with degree less than m by irreducible polynomial. For circuit implementation of proposed algorithm, we design the circuit using multiplexer and show the example over GF(24). The proposed architectures are regular and simple extension for m. Also, the comparison result show that the proposed architecture is more simple than privious multipliers. Therefore, it well suited for VLSI realization and application other operation circuits.

Assembly of Laccase over Platinum Oxide Surface and Application as an Amperometric Biosensor

  • Quan, De;Kim, You-sung;Yoon, Kyung-Byung;Shin, Woon-sup
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.3
    • /
    • pp.385-390
    • /
    • 2002
  • Laccase could be successfully assembled on an amine-derivatized platinum electrode by glutaraldehyde coupling. The enzyme layer formed on the surface does not communicate electron directly with the electrode, but the enzymatic activity of the surf ace could be followed by electrochemical detection of enzymatically oxidized products. The well-known laccase substrates, ABTS (2,2'-azinobis(3-ethylbenzothiazoline-6-sulfonic acid)) and PPD (p-phenylenediamine) were used. ABTS can be detected down to 0.5 ${\mu}M$ with linear response up to 15 ${\mu}M$ and current sensitivity of 75 nA/ ${\mu}M.$ PPD showed better response with detection limit of 0.05 ${\mu}M$, linear response up to 20 ${\mu}M$, and current sensitivity of 340 nA/ ${\mu}M$ with the same electrode. The sensor responses fit well to the Michaelis-Menten equation and apparent $K_M$ values are 0.16 mM for ABTS and 0.055 mM for PPD, which show the enzymatic reaction is the rate-determining step. The laccase electrode we developed is very stable and more than 80% of initial activity was still maintained after 2 months of uses.

Improved Cycle Life and Storage Performance in High-Voltage Operated Li2MnO3-LiMO2(M=Ni, Co, Mn)/Graphite Cell System by Fluorine Compounds as Main Electrolyte Solvent (고전압 구동 Li2MnO3-LiMO2(M=Ni, Co, Mn)/graphite 시스템에서의 전지 수명 및 고온 방치 특성 향상에 효과적인 플루오로 화합물계 전해액에 대한 연구)

  • Yu, Jung-Yi;Shin, Woocheol;Lee, Byong-Gon
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.3
    • /
    • pp.162-168
    • /
    • 2013
  • $Li_2MnO_3-LiMO_2$(M=Ni, Co, Mn) nano-composite is a promising cathode material for xEV application due to its high theoretic capacity. However high voltage operating system of $Li_2MnO_3-LiMO_2$(M=Ni, Co, Mn) has worked as a hurdle in its application because of the inherent demerits, such as cycle life degradation and gas evolution. In order to enhance cell performance of $Li_2MnO_3-LiMO_2$(M=Ni, Co, Mn)/graphite cell, we examined electrolyte mainly composed of FEC, fluroalkyl ether and $LiPF_6$ (F-based EL). F-based EL showed much better discharging retention ratio than 1.3 M $LiPF_6$ EC/EMC/DMC (3/4/3, v/v/v) (STD). Furthermore gas evolution, especially CO and $CO_2$ during $60^{\circ}C$ storage for 30 days was dramatically reduced owing to thermal stable SEI formation effect of F-based EL.

Effects of soluble silicon on development powdery mildew(Sphaerotheca fuliginea) in cucumber plants (규소 시용에 의한 오이 흰가루병 발병억제)

  • Lee, Jung-Sup;Yiem, Myeong-Sun
    • The Korean Journal of Pesticide Science
    • /
    • v.4 no.2
    • /
    • pp.37-43
    • /
    • 2000
  • Effects of silicon application on development of colonies of Sphaerotheca fuliginea were examined. Cucumber plants were applied with nutrient solutions amended with different concentrations of soluble silicon and selected leaves were inoculated with known concentrations of conidia of the pathogen. Colony number per leaf, colony area per leaf, and germination rate of conidia of S. fuliginea collected from the inoculated leaves were reduced as silicate concentrations in the nutrient solutions increased from 0.05 to 4.10 mM. The increase in resistance of plants to mildew infection was apparently due to silicate accumulation in leaves, and there was no correlation between cation or ionic strength effects and the silicate treatments. Silicate treatment in growth medium remarkably suppressed powdery mildew development on cucumber. Colonies of mildew fungus were visible with over approx. 38.3% of the mature leaf surface, while that of the leaves in high Si plants was 2.3% observed at 51 days after transplanting. No significant differences were observed between 1.7 mM and 3.4mM silicate treatments. Conidial germination rates were significantly reduced by increasing Si amendments. Conidial germination ranged from 14.7 to 20.3% for plants grown in low Si solution(<1.40 mM), and from 9.0 to 12.4% for plants grown in high Si solution(>1.8 mM). Foliar applications of Si with ${\geq}$ 17.0 mM decreased the number of powdery mildew colonies. Persistence of Si foliar sprays effects on cucumber demonstrated that the 17 mM Si spray applied 4 days before inoculation with S. fuliginea reduced mildew colony formation. The relationship was positive and linear.

  • PDF

Effects of Compost Application on Soil Loss and Physico-Chemical Properties in Lysimeters (퇴비시용(堆肥施用)이 토양유실량(土壤流失量)과 토양이화학성(土壤理化學性)에 미치는 영향)

  • Yun, Bong-Ki;Jung, Pil-Kyun;Oh, Se-Jin;Kim, Sun-Kwan;Ryu, In-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.29 no.4
    • /
    • pp.336-341
    • /
    • 1996
  • This study was conducted to investigate the effects of compost application on the soil loss and physico-chemical properties at the slope land from 1990 to 1991. Lysimeters with 15% slope. 5m slope length. 2m width and 1.2m depth were constructed in 1984 and filled with sandy loam, loam, clay loam. and clay soils. Treatments were bare soil, compost(1.5ton/10a) and non-compost with soybean-barley cropping system from 1984. Losses of soil were increased with the order of sandy loam, clay, loam and clay loam. Run-off was increased with the order of sandy loam, loam, clay loam and clay, but leachate was decreased with the same order. Compost treatments decreased 33.6-44.6% of soil loss and 17.0-24.0% of run-off but increased 17.1-33.7.% of leachate as compared with the non-compost treatments. The amount of soil loss was positively correlated with the amount of run-off by Y = 12.125+0.063X (r=$0.970^{**}$)and negatively correlated with the leachate by Y=43.425-0.096X(r=$-0.917^{**}$). The application of compost increased soil pH, OM, CEC and extractable cations. Application of compost decreased bulk density but increased porosity, water stable aggregate and available water. These results provide that the compost application plays an important role in conserving soil and water, and improving soil physico-chemical properties.

  • PDF

Kinetic Behavior of Immobilized Tyrosinase on Carbon in a Simulated Packed-Bed Reactor (충전층에서 탄소에 고정시킨 Tyrosinase의 반응속도에 관한 연구)

  • Shin, Sun Kyoung;Kim, Kyeo-Keun
    • Analytical Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.66-74
    • /
    • 1997
  • Influence of the axial dispersion on immobilized enzyme catalytic bed was investigated in order to examine the kinetic behavior of the biocatalysis. The enzyme employed in this study was the tyrosinase(EC 1.14.18.1) immobilized on carbon support : this system requires two substrates of phenol and oxygen. This enzyme has potential application for phenol degradation in waste water. A simulated reactor was a packed-bed reactor of 2.54cm in diameter and 10cm long, loaded with the immobilized carbon particle with an average diameter of $550{\mu}m$. A phenol feed in the strength of 55.5mM(5220ppm) was used to observe the behavior of the immobilized enzyme column at three different dissolved oxygen levels of 0.08445mM(2.7ppm), 0.1689mM(5.4ppm) and 0.3378mM(9.5ppm) with the flow rates in the range of 60(1mL/s) to 180mL/min(3mL/s). Examination of the Biot number and Damkolher numbers of the immobilized system enables us to eliminate the contribution of external mass transfer to set of differential equations derived from the dispersion model. Solution of the equation was finally obtained numerically with the application of the Danckwert boundary conditions and the assumed zero-and first order rates on the non-linear two substrate enzyme kinetics. Higher conversion of phenol was observed at the low flow rates and at the higher oxygen concentration. Comparison of axial dispersion and plug flow model showed that no detectable difference was observed in the column outlet conversion between the axial and the plug flow models which was in complete agreement with the previous studies.

  • PDF

A New Quinoline-Based Acylhydrazone for Highly Selective Fluorescence Recognition of Cu(II) and Sulfide in Aqueous Solution

  • Tang, Lijun;Zhou, Pei;Qi, Zhikai;Huang, Zhenlong;Zhao, Jia;Cai, Mingjun
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2256-2260
    • /
    • 2013
  • A new quinoline-based acylhydrazone (1) has been synthesized and applied as a fluorescent probe. Probe 1 exhibits high selectivity and sensitivity to $Cu^{2+}$ with fluorescence "ON-OFF" behavior in HEPES buffered (1‰ DMSO, HEPES 20 mM, pH = 7.4) solution. The on-site generated 1-$Cu^{2+}$ complex displays excellent selectivity to sulfide ions with fluorescence "OFF-ON" performance through copper displacement approach.

Clustering Scheme for (m,k)-Firm Streams in Wireless Sensor Networks

  • Kim, Ki-Il
    • Journal of information and communication convergence engineering
    • /
    • v.14 no.2
    • /
    • pp.84-88
    • /
    • 2016
  • As good example of potential application-specific requirement, (m,k)-firm real-time streams have been recently introduced to deliver multimedia data efficiently in wireless sensor networks. In addition to stream model, communication protocols to meet specific (m,k)-firm real-time streams have been newly developed or extended from existing protocols. However, since the existing schemes for an (m,k)-firm stream have been proposed under typical flat architecture, the scalability problem remains unsolved when the number of real-time flows increases in the networks. To solve this problem, in this paper, we propose a new clustering scheme for an (m,k)-firm stream. The two different clustering algorithms are performed according to either the (m,k)-firm requirement or the deadline. Simulation results are presented to demonstrate the suitability of the proposed scheme under hierarchical architecture by showing that its performance is acceptable irrespective of the increase in the number of flows.

A study on the accuracy of zirconia copings using dental CAD / CAM system (치과용 CAD/CAM 시스템을 이용한 지르코니아 코핑의 정확성에 관한 연구)

  • Yoon, Seong-Geun;Choi, Byung-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.33 no.2
    • /
    • pp.137-145
    • /
    • 2011
  • Purpose: To evaluate the accuracy of zirconia copings in terms of clinical verified for the clinical application of CAD/CAM. Methods: Zirconia copings (n=5) were prepared using CAD/CAM system and were sintered using the relevant electrical induction furnace, which uses a 2h sintering program with a maximum temperature of $1500^{\circ}C$. The copings placed at the models and the interval values were measured. Results: The meas interval values between the die and the zirconia copings were $44.14{\mu}m$(A), $44.57{\mu}m$(B), $44.72{\mu}m$(C). 51.05 ${\mu}m$(D). Conclusion: The maximum interval values between the die and the zirconia copings were $51.3{\mu}m$ which is acceptable for clinical use. ${\mu}m$ Proper understanding of the test conditions will help enhancing the accuracy of zirconia coping.

A Study on the Application of Water Mist Fire Extinguishing System to Machinery Spaces (미분무수 소화설비의 선박용 기관실 적용에 관한 연구)

  • Kim, Ki-Ok;Ann, Byung-Ho;Yang, Woo-Jin;Kim, Young-Han
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.132-133
    • /
    • 2005
  • A study to evaluate the fire extinguishing performance of the water mist system inside simulated machinery spaces according to IMO MSC/Circ.668 was performed. Fire tests were conducted inside a compartment having a area 100$m^2$(10m${\times}$10m) with a ceiling height of 10m and door opening of 2m${\times}$2m in size. Test fuels were used heptane, diesel, wood crib and mineral oil. Water mist nozzles were installed downward at ceiling and horizontally at bilge area. All fires in the test were extinguished within 15minutes of system activation and there was no reignition or fire spread.

  • PDF