• Title/Summary/Keyword: M2M Device

Search Result 2,297, Processing Time 0.032 seconds

A SHEAR BOND STRENGTH OF RESIN CEMENT BONDED TO HUMAN UNCUT ENAMEL, CUT ENAMEL, AND DENTIN IN VITRO

  • Lee Jong-Yeop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.319-324
    • /
    • 2003
  • Statement of problem. Adhesives in dentistry playa major role in the success of restorative treatments. In the treatment of all ceramic restoration it is needed to find the adequate bond strength between enamel and dentin. Purpose. The purpose of this study was to evaluate shear bond strength of resin cement bonded to extracted human uncut enamel, cut enamel, and dentin in vitro. Material and methods. Ten freshly extracted anterior teeth without any previous restorative treatments were chosen. The extracted teeth were embedded in PMMA cold acrylic in the shape of a cylinder, 25 mm in diameter by 25 mm in height. The bonding system used was as follow: Uni-Etch (32% phosphoric acid), One-Step adhesive, Duolink resin cement. The specimens were acid etched and rinsed with water. Two layers of One-Step adhesive were coated with a disposable brush on the uncut enamel. VIP curing light at $500mV/cm^2$ was used to cure the adhesive. For cut enamel shear bond test, the specimen used for uncut enamel was further reduced approximately $0.3{\sim}0.5mm$ using a laminate preparation diamond bur (0.3 mm in depth). The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit SiC paper and cleaned with distilled water. The bonding procedure on the cut enamel was same as uncut enamel bonding procedure. For dentin bonding test, the specimen used for cut enamel was further reduced approximately $0.5mm{\sim}1.0mm$ using a laminate preparation diamond bur (0.5 mm in depth of diamond cutting). The amount of reduction was evaluated with the silicone mold. The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit silicon carbon paper and cleaned in distilled water. The bonding procedure on the dentin was same as uncut enamel bonding procedure. All samples were mounted and secured on the Ultradent shear bond test sample holder, and Ultradent restricted shear bond testing device was used with Universal Instron machine until fracture. Analysis of variance (ANOVA) test was performed comparing the result at P<0.05. Multiple comparison (Tukey) was used to compare each groups. Result. The result showed that the mean value in shear bond strength of resin cement bonded to uncut enamel, cut enamel and dentin were 27.04 Mpa, 30.25 Mpa and 26.39 Mpa with respect. Conclusion. Within the limitation of this study, the mean value of the shear bond strength of cut enamel was higher than those of uncut enamel or dentin. However there existed no statistical differences between three different human dentition substrates due to increased adhesive characteristics.

Design and Performance Evaluation of Small Size Counting and Imaging Gamma Probe System (소형 계수용 및 영상용 감마프로브 시스템의 설계와 성능평가)

  • Yang, Myo-Geun;Kwark, Cheol-Eun;Sim, yong-Geol;Kim, Hee-Joung;Choi, Yong;Chung, Jung-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.291-299
    • /
    • 1997
  • As a microimaging device detecting gamma rays emitted from small lesions or tumors during operation, the intraoperative surgical probe has been proposed and is now under development. We have designed a multipurpose portable gamma prove system and evaluated the performance both for the absolute counting purpose of residual radioactivities and for the localizing capability of gamma events using the NaI(Tl) crystal and two types of photomultiplier tubes(PMTs). Counting efficiencies in the range of routine clinical use of radiation dose were measured using the assembly of single channel PMTs and 0.5 inch thick NaI(Tl) crystal of 1 inch diameter. The positioning of gamma events for imaging purpose requires the multiple channel PMTs with appropriate positioning electronics. We have designed a simple and reliable positioning circuit based on the concept of modified Anger. In preliminary experiments using the multiple channel PMT of 3 inch diameter and the dim lighth source, we were able to trace and localize the correct position with reduced positioning error by the use of two multiplier/divider chipset and simplified peripherals. The energy resolutions for the counting gamma probe measured as full width at half maximum(FWHM) for Cs-137, F-18, Tc-99m were 12%, 13%, and 36%, respectively. The spatial resolution for the imaging gamma probe measured as FWHM for green LED was 2.9 mm. The results indicate that the currently developing probe is very promising and could be very useful for many applications in nuclear medicine. Future studies will include developing collimators, improving interface hardwares, and evaluating the system with clinical data.

  • PDF

Effects of Swim Training on Tuberculosis infection in the Mouse Model at Different Temperature (온도 차이에 따른 수영훈련이 결핵균 감염정도에 미치는 영향)

  • Kwak Yi-Sub
    • Journal of Life Science
    • /
    • v.15 no.4 s.71
    • /
    • pp.652-656
    • /
    • 2005
  • Tuberculosis is the leading infectious disease in the world. It is urgent to develop new vaccine and treating drugs. Besides vaccines, we want to know the effects of regular swim training on TB infection in the mouse model. This study was designed to examine the effects of regular swim training on lung and spleen TB counts and $INF-\gamma$ activity in the trained mice at different temperature. The trained mice underwent a 10-wk endurance swim training (5 times/wk) in water at $29\~33^{\circ}C$ (WWG) and $21\~23^{\circ}C$(CWG) for 60 min. And they were divided into 3 groups according to the regular swim training (CG; control, WWG; warm water group, and CWG; cold water group). Mice were challenged by aerosol infection with M. tuberculosis H37Rv using an inhalation device (Glas-Col, Terre Haute, Ind.) calibrated to deliver bacteria into lungs. Three weeks after immunization, the mice were challenged. Four weeks after challenge, the mice were sacrificed and the numbers of viable bacteria in lung and spleen were determined by plating serial dilution of whole organ homogenates on nutrient Middlebrook 7H11 agar (Difco, Detroit, MI). Colonies were counted after four weeks incubation at $37^{\circ}C$. All data were expressed as mean, standard deviation by using SPSS package program (win 10.0). The result through the statistical analysis of this data were summarized as follows; In the weight changes, there were significant differences among CG, WWG, and CWG following the swim training at different temperature, and CWG was the lowest. In the change of $INF-\gamma$ following the swim training, there were significant differences (p<.05) among CG, WWG, and CWG after stimulated with media and CFP. In MTB counts, there were significant differences (p<.05) between CG and WWG in the lung. And also there were significant differences (p<.05) among CG, WWG, and CWG. These results suggest that regular swim training suppress Th1 immune response caused by decreased $INF-\gamma$ level in the WWG, Also For the WWG, highly increased level of TB counts appear in the lung and spleen compare to CG.

Inorganic Electro-luminescence Device Fabricated with $BaTiO_3$-PVDF Composite Film ($BaTiO_3$-PVDF 복합체로 제작한 무기 EL 소자)

  • Son, Yong-Ho;Jeong, Joon-Seok;Jo, Chan-Woo;Woo, Duck-Hyun;Kim, Young-Min;Kim, Sung-Jin;Yoon, Man-Soon;Ryu, Sung-Lim;Kweon, Soon-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.299-299
    • /
    • 2007
  • 후막형 무기 EL (electro-luminescence) 소자는 제조공정이 간단하고, 얇고, 가볍고, 유연한 동의 많은 장점들 때문에 휴대폰의 키패드 (key-pad) 및 광고용 back-light용으로 사용되고 있다. 이 무기 EL 소자는 비교적 손쉬운 스크린 프린팅 (screen-printing) 법으로 대면적을 제작할 수 있지만, LED (light emitting diode) 등과 비교하여 밝기가 낮아서 그 응용 분야가 제한되고 있다. EL 소자의 형광층은 전면 전극과 후면 전극 사이에 위치한다. EL은 이 형광층에 고 전기장이 걸릴 때, 전기장에 의해 가속된 전자가 형광층 내부에 첨가된 발광 중심의 전자를 여기시키고, 여기된 전자가 다시 바닥상태로 완화될 때 빛이 방출되는 현상이다. 즉, EL 소자는 이러한 전자 발광 현상을 이용한 소자로서, 전압 인가 시 발광 면 전체가 균일하게 발팡하는 평면 광원이다. 이러한 EL 소자에서 휘도의 증가는 후면 전극과 형광층 사이에 삽입되는 유전체 층의 특성과 밀접한 연관성이 있다. 본 연구에서는 고휘도 무기 EL 소자를 제작하기 위하여 이 유전체 층의 특성과 소자의 성능 사이의 관계를 알아보고자 하였다. 유전체 층에 사용하기 위해서 $BaTiO_3$-PVDF (polyvinylidene fluoride)의 복합체 필름을 제조하였다. 먼저 이 복합체 필름을 스크린 프린팅 (screen printing) 법으로 코팅하기 위한 페이스트 제작을 위해서, PVDF 수지를 용제에 녹였다. 그 다음, 일반 혼합기 및 삼단 롤밀 혼합기 (3-roll milling mixer) 등을 이용하여 $BaTiO_3$ 분말과 PVDF 용액을 다양한 비율로 혼합하여 페이스트를 제조하였다. ITO가 증착된 PET Film에 스크린 프린팅 법을 사용하여 형광층, 유전층, 배면 전극 등을 차례로 코팅하였다. $BaTiO_3$ (BT) 분말과 복합체 필름의 XRD 분석 결과, 분말 시료와 복합체 시료 모두 페로브스카이트 구조의 BT 회절선만 관찰되었다. 복합체의 단면 SEM 관찰에서는, BT 분말의 무게비가 증가할수록 더 치밀한 구조를 보여줌을 확인하였다. 또 EL소자의 유전상수와 휘도도 BT 분말의 혼합비가 증가할수록 증가하였다. 본 연구에서 제작한 무기 EL 소자의 최대 휘도는 약 $130\;cd/m^2$ 정도로 측정되었는데, 이는 휴대폰 키패드의 back-light용 광원으로 사용하기 충분하다고 판단되어진다.

  • PDF

Effects of Posttraumatic Hypothermia in an Animal Model of Traumatic Brain Injury(TBI) - Immunohistochemical Stain by TUNEL & β-APP - (실험적 외상성 뇌손상모델에서 외상 후 저체온법의 효과 - TUNEL과 β-APP Immunohistochemical Stain -)

  • An, Byeong Kil;Ha, Young Soo;Hyun, Dong Keun;Park, Chong Oon;Kim, Joon Mee
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.4
    • /
    • pp.461-470
    • /
    • 2000
  • Objective : Many investigators have demonstrated the protective effects of hypothermia following traumatic brain injury(TBI) in both animals and humans. It has long been recognized that mild to moderate hypothermia improves neurologic outcomes as well as reduces histologic and biochemical sequelae after TBI. In this study, two immunohistochemical staining using terminal deoxynucleotidyl-transferase-mediated biotin dUTP nick end labeling(TUNEL), staining of apoptosis, and ${\beta}$-amyloid precursor protein(${\beta}$-APP), a marker of axonal injury, were done and the authors evaluated the protective effects of hypothermia on axonal and neuronal injury after TBI in rats. Material and Method : The animals were prepared for the delivery of impact-acceleration brain injury as described by Marmarou and colleagues. TBI is achieved by allowing of a weight drop of 450gm, 1 m height to fall onto a metallic disc fixed on the intact skull of the rats. Fourty Sprague-Dawley rats weighing 400 to 450g were subjected to experimental TBI induced by an impact-acceleration device. Twenty rats were subjected to hypothermia after injury, with their rectal temperatures maintained at $32^{\circ}C$ for 1 hour. After this 1-hour period of hypothermia, rewarming to normothermic levels was accomplished over 30-minute period. Following 12 hours, 24 hours, 1 week and 2 weeks later the animals were killed and semiserial sagittal sections of the brain were reacted for visualization of the apoptosis and ${\beta}$-APP. Results : The density of ${\beta}$-APP marked damaged axons within the corticospinal tract at the pontomedullary junction and apoptotic cells at the contused cerebral cortex were calculated for each animal. In comparison with the untreated controls, a significant reduction in ${\beta}$-APP marked damaged axonal density and apoptotic cells were found in all hypothermic animals(p<0.05). Conclusion : This study shows that the posttraumatic hypothermia result in substantial protection in TBI, at least in terms of the injured axons and neurons.

  • PDF

Prototype Development of a Three-wheel Riding Cultivator and Its Basic Performance

  • Lee, Beom Seob;Yoo, Soonam;Lee, Changhoon;Choi, Il Su;Choi, Yong;Yun, Young Tae
    • Journal of Biosystems Engineering
    • /
    • v.43 no.4
    • /
    • pp.285-295
    • /
    • 2018
  • Purpose: The aim of this study is to develop a three-wheel riding cultivator for improving the performance of the current four-wheel riding cultivators in the market. Methods: A prototype three-wheel riding cultivator with the rated power of 15.5-kW, a primary hydrostatic and a two-speed selective gear transmission shifts, front/rear three-wheel drive, a hydraulic wheel tread adjustment, and the mid-section attachment of the major implements was designed and constructed. Its specifications and basic performance are investigated. Results: The maximum speeds of the prototype at the low and high stages were measured to be approximately 7.31, and 11.29 km/h in forward travel, respectively, and approximately 3.60, and 6.37 km/h in rearward travel, respectively. The minimum ground clearance is shown to be 670 mm. The rotating speeds of the power takeoff (PTO) shaft at the low and high stages are shown to be approximately 795 and 1,140 rpm, respectively. The tread of the rear wheels, the minimum radius of turning, and the maximum lifting height of the parallel link device are measured to be within 1,320-1,720 mm, 2.80 m, and 390 mm, respectively. Approximately 25.3% and 74.7% of the total weight of the prototype are distributed in the front and rear wheels on flat ground, respectively. When the tread of rear wheels increased from 1,320 to 1,720 mm, the left and right static lateral overturning angles increased from $33.4^{\circ}$ to $39.1^{\circ}$ and from $29.0^{\circ}$ to $36.1^{\circ}$, respectively. Conclusions: The prototype three-wheel riding cultivator showed a wide range of travel and PTO speeds, high minimum ground clearance, small minimum radius of turning, and easy control of the rear wheel tread. Further, the easy observation of cultivating operations by mid-mounting the implements can improve quality of work. Therefore, the prototype is expected to contribute to the riding mechanization of cultivating operations for various upland crops in Korea.

Change of Dose Exposure and Improvement of Image Quality by Additional Filtration in Mammography (유방촬영용장치 부가필터에 따른 선량변화 및 화질개선)

  • Cho, Woo Il;Kim, Young Kuen;Lee, Gil Dong
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.78-90
    • /
    • 2013
  • Recently, the interest on exposure to radiation is rising. The radiation exposure of mammography is higher in absorbed dose than of X-ray, therefore unnecessary exposure needs to be reduced, and higher image quality is needed. Generally, ray quality of the radiation imaging is an important factor that determines image quality and the amount of ray exposure, and they are affected by tube voltage and added filter. The X-ray energy that is exposed from mammography device is generally a continuous spectrum, which includes low energy that has minute influence on the image quality, and high energy that hinders contrast on image. Currently, molybdenum (Mo) and rhodium (Rh) are the most used added filters for mammography device, and they are used differently according to the energy region of X-ray. This study aims to find out the degree of reduction in exposure dose according to the thickness of aluminum (Al), and to study the changes in image quality and dose when the added filter plates that are made with niobium (Nb) or zirconium (Zr) are used, other than molybdenum (Mo) and rhodium (Rh), the two most used added filters that have similar atomic number and K-absorption regions as Nb and Zr. In this study, single-added filters of molybdenum (Mo), niobium (Nb), and zirconium (Zr) are used, and in some cases, Aluminum (Al) is combined with the single filters. In this case, image quality is considered to be improved depending on the type of added filters, and by using Aluminum (Al) filter together with the others, unnecessary X-ray of low energy would be absorbed, therefore the dose is expected to decrease without any influence when the concentration level becomes identical.

Initial Experience of the Emergency Bypass System ($EBS^{(R)}$) for the Patients with Cardiogenic Shock due to an Acute Myocardial Infarction (급성 심근경색으로 인한 심인성 쇼크 환자에 대한 경피적 순환 보조장치($EBS^{(R)}$) 적용의 초기경험)

  • Ryu, Kyoung-Min;Kim, Sam-Hyun;Seo, Pil-Won;Ryu, Jae-Wook;Kim, Seok-Kon;Kim, Young-Hwa;Park, Seong-Sik
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.329-334
    • /
    • 2008
  • Background: Percutaneous cardiopulmonary support. (PCPS) has the potential to rescue patients in cardiogenic shock who might otherwise die. PCPS has been a therapeutic option in a variety of the clinical settings such as for patients with myocardial Infarction, high-risk coronary intervention and postcardiotomy cardiogenic shock, and the PCPS device is easy to install. We report our early experience with PCPS as a life saving procedure in cardiogenic shock patients due to acute myocardial infarction. Material and Method: From January 2005 to December 2006, eight patients in cardiogenic shock with acute myocardial infarction underwent PCPS using the CAPIOX emergency bypass system($EBS^{(R)}$, Terumo, Tokyo, Japan). Uptake cannulae were inserted deep into the femoral vein up to the right atrium and return cannulae were inserted into the femoral artery with Seldinger techniques using 20 and 16-French cannulae, respectively. Simultaneously, autopriming was performed at the $EBS^{(R)}$ circuit. The $EBS^{(R)}$ flow rate was maintained between $2.5{\sim}3.0L/min/m^2$ and anticoagulation was performed using intravenous heparin with an ACT level above 200 seconds. Result: The mean age of patients was $61.1{\pm}14.2$ years (range, 39 to 77 years). Three patients were under control of the $EBS^{(R)}$ before percutaneous coronary intervention (PCI), three patients were under control of the $EBS^{(R)}$ during PCI, one patient was under control of the $EBS^{(R)}$ after PCI, and one patient was under control of the $EBS^{(R)}$ after coronary bypass surgery. The mean support time was $47.5{\pm}27.9$ hours (range, 8 to 76 hours). Five patients (62.5%) could be weaned from the $EBS^{(R)}$ after $53.6{\pm}27.2$ hours. (range, 12 to 68 hours) of support. All of the patients who could successfully be weaned from support were discharged from the hospital. There were three complications: one case of gastrointestinal bleeding and two cases of acute renal failure. Two of the three mortality cases were under cardiac arrest before $EBS^{(R)}$ support, and one patient had an intractable ventricular arrhythmia during the support. All of the discharged patients are still surviving at $16.8{\pm}3.1$ months (range, 12 to 20 months) of follow-up. Conclusion: The use of $EBS^{(R)}$ for cardiogenic shock caused by an acute myocardial infarction could rescue patients who might otherwise have died. Successfully recovered patients after $EBS^{(R)}$ treatment have survived without severe complications. More experience and additional clinical investigations are necessary to elucidate the proper installation timing and management protocol of the $EBS^{(R)}$ in the future.

The Actual State and the Utilization for Dental Radiography in Korea (국내 치과방사선의 현황 및 이용 실태)

  • Shin, Gwi-Soon;Kim, You-Hyun;Lee, Bo-Ram;Kim, Se-Young;Lee, Gui-Won;Park, Chang-Seo;Park, Hyok;Chang, Kye-Yong
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.109-120
    • /
    • 2010
  • The purpose of this study was first to analyze the utilization of dental examination through questionnaire to develop a diagnostic reference level of patient doses for dental radiography in korea. 77 dental institutions were classified into three groups: A group for the dental hospitals of the college of dentistry (11 institutions), B group for dental hospitals (30 institutions) and C group for dental clinics (36 institutions). The results were as follows : The mean numbers of unit chairs and medical staffs were 140.2, 15.3 and 5.8 sets, 112.6, 7.3 and 1.7 dentists, 3.1, 0.5 and no one radiologic technologists, and 19.7, 12.5 and 3.3 dental hygienists in A, B and C groups, respectively. The mean numbers of dental X-ray equipments were 14.64, 3.21 and 2.19 in A, B and C groups, respectively. Intraoral dental X-ray unit was used the most, the following equipments were panoramic, cephalometric, and cone-beam CT units. The most used X-ray imaging system was also digital system (above 50%) in all three groups. Insight dental film (Kodak, USA) having high sensitivity was routinely used for periapical radiography. The automatic processor was not used in many dental institutions, but the film-holding device was used in many dental institutions. The utilization rates of PACS in A, B and C groups were 90.9%, 83.3% and 16.7% respectively, and the PACS software program was used the most PiView STAR (Infinitt, Korea). The annual mean number of radiographic cases in one dental institution in 2008 for A group was 6.8 times and 21.2 times more than those for B and C groups, and periapical and panoramic radiographs were taken mostly. Tube voltage (kVp) and tube current (mA) for periapical radiography were similar in all three groups, but exposure time in C group was 12.0 times and 3.5 times longer than those in B and C groups. The amount of radiation exposure in C group, in which dental hygienists take dental radiographs, was more than those in other groups. The exposure parameters for panoramic radiography were similar in all three groups. In conclusion, the exposure parameters in dental radiography should be determined with reference level, not past experiences. Use of automatic processor and film-holding devices reduces the radiation exposure in film system. The quality assurance of dental equipments are necessary for the reduction of the patient dose and the improvement of X-ray image quality.

TREATMENT OF MALOCCLUSION, AS RELATED TO FINGER SUCKING : CASE REPORT (손가락 빨기로 인한 부정교합의 치험례)

  • Moon, Sang-Jin;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • The habit of finger sucking is a reflex occurring in the oral stage, due to nutritive and psychological desire. The habit of finger sucking is considered to be normal till 3 years of age. Dento-skeletal effect on maxillo-mandibular complex including occlusion is naturally correction, when habit stopped before 3 years. If finger sucking continues till $3{\sim}4$ years, Finger sucking leads to severe malocclusion and remarkable discrepancy maxillo-mandibular complex, which is difficult in expectation of natural correction. It is necessary to positive treatment. Treatment of malocclusion, as related to finger sucking is classified two methods. (psychological approach and orthodontic appliance) To stop a habit and to correct severe skeletal discrepancy and malocclusion, $fr\ddot{a}nkel$ appliance is very effective device. This study is to report two cases of treatment of malocclusion, as related to finger sucking. 2 years 10 months old girl with severe overjet, maxillo-mandibular skeletal discrepancy and severe convex facial profile was treated with a FR-II appliance. Finger sucking habit stopped immediately After 16 months, severe overjet, maxillo-mandibular skeletal discrepancy and severe convex facial profile was corrected. 4 years 2 months old girl with midline deviation, mandibular right shift, collateral posterior crossbite and facial asymmetry was treated with a FR-III appliance. Finger sucking habit stopped immediately. After 10 month, Midline deviation, mandibular right shift, collateral posterior crossbite and facial asymmetry were corrected. FR-appliance is a recommendable appliance for a habit breaker and correction of skeletal discrepancy.

  • PDF