• 제목/요약/키워드: M2M (Machine to Machine)

검색결과 1,080건 처리시간 0.038초

X-선(線) 조사(照射)가 Ehrlich 암세포(癌細胞)의 용적(容積), 단백양(蛋白量) 및 수종(數種) Sulfhydryl 기(基)에 미치는 영향(影響)에 관(關)하여 (Effect of X-Irradiation on the Levels of some Sulfhydryl Groups, Protein and Cell Volume of Ehrlich Ascites Tumour Cells)

  • 유춘식;주영은
    • The Korean Journal of Physiology
    • /
    • 제3권2호
    • /
    • pp.9-16
    • /
    • 1969
  • It is well known that a number of -SH and -SS containing substances afford a certain measure of protection against radiation effects in many biological systems, and it is conceivable that inherent -SH levels in Ehrlich ascites tumour (ELD)cells may be of decisive improtance with respect to the development of cellular radiation injury. So far, little effort has been directed to elucidate the changes in levels of different -SH and -SS groups in ELD cells when the tumour-bearing whole animal was subjected to the sublethal dose of X-irradiation. The present study was designed to bring some lights in the possible changes of and relationship between various sulfhydryl levels, such as P-SH, NP-SH and NP-SS, as well as the content of protein and cell volume of ELD cells, after subjecting the ELD mice to 1,200 r of X-irradiation. The animals used in this experiment were all mixed bred mice of $20{\sim}25\;gm$ in body weight (approximately 2 months old) irrespective of sex. 12 mice in one experiment were inoculated intraperitoneally with 0.2 ml of ascites tumour cells $(2{\times}10^6\;cells)$, and on the 7th day of the tumour growth, they were X-irradiated with 1,200 r, using the conventional X-ray machine under the following conditions: 200 Kv at 15 mA, 0.5 mm Cu filter, target-skin distance: 50 cm. Radiation dose was measured with the the Philip integrating dosimeter. At 24, 36, 48 and 60 hours after the X-irradiation, the mice were killed by cervical dislocation, and the tumours were taken out. Freshly withdrawn ascites tumours were placed in ice, and immediately the cell concentration was measured with the Coulter Cell Counter (Model B), and the hematocrit of the tumour cells were also determined. Cell volume was thus calculated by the cell concentration and hematocrit value. P-SH content of ELD cells was measured potentiometrically according to the method of Calcutt & Doxey, and NP-SH and NP-SS contents were measured spectrophotometrically by the method described by Ellman. Protein content of ELD cells was determined with the Folin phenol reagent by Lowry et al. Altogether, 48 experimental mice were used, and 12 mice with the only exception of X-irradiation were used as the control. Results obtained indicate that the contents of all the cellular sulfhydryl groups as well as cell volume and protein content of the ELD cells increase significantly as time progresses after the sub-lethal X-ray dose of 1,200 r was given and that all the increase is in a lineal fashion. The regression lines of the relative values, (i. e., taking each control value as 1) of all the values obtained, and the regression lines of cell volume, protein and NP-SH are identical, whereas those of NP-SS and P-SH appear to be widely seperated. However, the difference of those two lines (NP-SS & P-SH) were found to be not significant statistically (p>0.05). Therefore, it can be concluded from the above results that all the values examined increase in a lineal fashion with no statistically significant difference among them. Also, with the radiation dose of 1,200 r, the ELD cell becomes enlarged and swollen progressively up to 60 hours post-irradiation and it becomes more than two times of the original normal size at 60 hours after the irradiation, and up to this stage, it seems apparent that the cell division has been slow due to the X-irradiation applied in this experiment. It is well understandable that the contents of NP-SH, NP-SS, P-SH and protein of the ELD cells increase in parallel with the increase of the cell volume by the X-ray does used, but it also seems interesting to note that all the cellular substances tested show no appreciable difference in the pattern of increase.

  • PDF

식도암 치료에 있어 관내근접치료의 역할 (The Role of Intraluminal Brachytherapy in Management of Esophageal Cancer)

  • 이창걸;서창옥;김귀언;추성실;정은지;김우철
    • Radiation Oncology Journal
    • /
    • 제13권4호
    • /
    • pp.331-338
    • /
    • 1995
  • 목적 : 식도암의 치료는 진단당시 국소적으로 진행된 예가 대부분으로 방사선치료 단독 혹은 유도화학 및 방사선병행요법 등이 주로 시행되고 있다. 그러나 이들 치료에도 불구하고 5년 생존율은 $5-10{\%}$로 극히 저조한 결과를 보고하고 있다. 이처럼 치유율이 저조한 것은 $50{\%}$이상의 원격전이율외에 궁극적으로 원발병소의 재발율이 약 $80{\%}$에 달하는 까닭이다. 최근 동시 화학방사선 병행요법으로 생존율 향상을 보고하고 있으나 이역시 약 $50{\%}$의 높은 국소재발율을 보고하고 있어서 식도암의 치료에 있어 국소제어의 중요성은 아무리 강조해도 지나치지 않다. 이에 저자들은 방사선치료 단독 혹은 화학 방사선 병행치료후 관내근접치료를 시행하여 반응률, 치료에 따른 합병증, 국소제어율 그리고 궁극적으로 생존율 향상에 기여할 수 있는지 보고자 하였다. 방법 : 1989년 11원부터 1993년 3월까지 식도암으로 진단받고 연세암센터 방사선종양학과에서 근치적목적으로 방사선치료 단독(7예) 혹은 유도화학 및 방사선병행치료(13예)후 관내근접치료를 시행받은 환자 20명을 대상으로 하였다. 전 환자는 남자였고, 연령은 48세에서 82세(median 60.5세), 전신수행도 H1(ECOG)이상 그리고 편평상피세포암의 조직소견을 나타내었다. 발생부위별로는 경부 4예($20{\%}$), 상흉부 6예($30{\%}$), 중흉부 6예($30{\%}$) 그리고 하흉부 4예($20{\%}$)였다. 병기(AJCC)별로 11기 4예($20{\%}$), III기 15예($75{\%}$), IV기 1예($5{\%}$)였다. 방사선치료는 180-200cGy/fraction으로 원발병소를 포함하여 종격동 및 국소림프절 영역에 총 5900-6400cGy/6-7주(median 5940cGy) 조사하였고 2-8주후 관내 근접치료를 시행하였다. 관내방사선 근접치료는 고선량률 Iridium-192 동위원소를 이용한 Gamma-Med 12i를 사용하였고 지름이 5-6mm의 nasogastric tube를 식도내 삽입한후 원발병소부위에 고정시키고 원격조정으로 치료하였다. 방사선량은 300-500cGy/ fraction를 식도점막하 5mm에 조사하였고 1-4 fraction/1-3주, 총 500-1200cGy 조사하였다. 유도화학요법은 5-FU(1g/m2,d1-5), cis-platinum (80mg/m2,d6)을 1-6회(median 3회) 4주간격으로 시행하였다. 전환자에서 사망시까지 추적관찰되었으며 생존환자의 최소 추적기간은 13개월이었다. 결과 : 전체 환자의 정중앙 생존기간은 13.5개월, 1년 및 2년 생존율은 $65{\%},\;15.8{\%}$였다. 관내치료후 반응률은 완전관해 5예($25{\%}$), 부분관해a 7예($35{\%}$), 부분관해b 7예($35{\%}$), 무반응 3예($15{\%}$)였다. 외부방사선치료후 반응률이 부분관해a + 완전관해의 경우 관내근접치료의 부가로 $50{\%}$(4/8)의 국소제어율을 보였고 관내근접 치료후 완전관해가 유도된 환자에서는 $80{\%}$(4/5)의 높은 국소제어율을 나타냈다. 치료 실패양상은 국소재발이 $65{\%}$(13/20), 원격전이 $0{\%}$ 그리고 국소및 원격 동시재발 $15{\%}$(3/20)로 궁극적인 국소재발율이 $75{\%}$였다. 치료에 따른 합병증은 경미한 식도염 $55{\%}$(11예), 중증의 식도염 $10{\%}$(2예), 식도궤양 $10{\%}$(2예) 등이었으나 보조적인 치료후 모두 회복되었고 그리고 식도협착의 경우가 1예 있었다. 정중앙 생존기간을 치료군별(방사선 단독 vs. 화학방사선 : 13개월, 15개월), 병기별(II vs III : 15개월, 13.5개월), 병소의 길이(<5cm VS ${\geq}$ 5cm : 18개월, 13개월), T병기(T1-2 VS

  • PDF

완전 자동화된 액체배양법과 기존의 고체배양법을 이용한 객담 내 mycobacterium의 신속검출에 대한 비교 (Fully Automated Liquid Culture System Compared with Lowenstein-Jensen Solid Medium for Rapid Recovery of Mycobacteria in Sputums)

  • 박승규;김승철;김득미;이창운;김영;조상래
    • Tuberculosis and Respiratory Diseases
    • /
    • 제53권6호
    • /
    • pp.635-643
    • /
    • 2002
  • 연구배경 : 완전 자동화된 액체배양법과 기존의 고체배양법을 이용하여 폐결핵환자의 객담내 mycobacterium의 신속검출율 및 양성판정시까지의 시간을 비교하고자 하였다. 방 법 : 2002년 1월 1일부터 2002년 6월 30일 사이에 본원에 입원 혹은 외래에서 폐결핵으로 치료중인 환자 127명의 객담검체를 이용하였으며, 배양 중 오염된 28개의 검체(MB/BacT system 18개, L-J배지 14개, 4검체는 두 배양법 모두에서 오염)를 제외한 99명의 객담검체를 대상으로 하였다. 검체는 4% NaOH로 전처치한 후 4300rpm으로 20분간 원심분리한 후 멸균된 phosphate buffer(pH 6.8)를 첨가하여 2ml로 만들어 MB/BacT bottle에 0.5ml, Lowenstein-Jensen배지에 0.25ml를 접종한 후 $35-37^{\circ}C$에 6-12주간 배양하면서 균검출율과 양성판정시까지의 시간을 비교하였다. 결 과 : MB/Bact system과 L-J배양볍 중 어느 한 방법에서 균성장이 발견된 검제는 677B (67.7%) 였다. 두배양법 모두에서 균성장이 발견된 겸체는 5252.5%) 개였으며, MB/BacT에서만 발견된 검체는 15개 (15.2%) 였으나 L-J배양법에서만 발견된 경우는 없었다. 객담검체의 ZN염색법으로 항산균 집균도말겸사상 양성인 검체는 58개, 음성인 검체는 41개였다. 58개의 도말양성 검체 가운데 MB/BacT system에 양성을 보인 검체는 %개 (96.6%), L-J배지양성은 467B (79.3%) 였으며, 균성장 평균 발견시간은 각각 11.0일과 23.5일이었다. 41개의 도말음성검체 가운데 MB/BacT system에 양성을 보인 검체는 11개 (26.8%), L-J배지양성은 6개 (14.6%)였으며, 균성장 평균 발견시간은 각각 13.7일과 27.6일 이었다. 전체적으로 MB/BacT system과 L-J배양법에서 균성장 발견시 간은 각각 $13.3{\pm}8.3$일, $27.2{\pm}0.9$일이었다. 결 론 : 완전 자동화된 MB/BacT system은 L-J배지에 비해 mycobacterium의 검출율이 높고 발견시간이 단축되었다. MB/BacT는 방사성 물질을 사용하지 않는 장점이 있으므로 모든 검사실에 사용하기에 적당할 것으로 보이며, 균동정을 위하여 특이한 DNA probe와 병용하면 CDC가 권고한 결과보고 시간에 근접할 수 있을 것으로 생각되었다.

Self-etching primer/adhesive를 사용한 교정용 브라켓의 접착시 오염이 전단결합강도에 미치는 영향 (The effect of contamination on bonding of orthodontic brackets with a self-etching prirneriadhesive)

  • 김유신;이형순;이현정;전영미;김정기
    • 대한치과교정학회지
    • /
    • 제34권5호
    • /
    • pp.439-447
    • /
    • 2004
  • 이 연구는 self-etching primer와 adhesive를 사용하여 법랑질 표면에 교정용 브라켓을 접착할 때 수분과 타액, 그리고 혈액에 의한 오염이 브라켓의 전단결합강도에 어떤 영향을 미치는지 알아보고자 시행되었다. 96개의 발거된 치아를 4개의 군으로 나누어서 self-etching primer와 adhesive를 사용하여 다음의 4가지 방법에 따라 교정용 브라켓을 접착하였다 첫 번째 군은 치면을 건조시킨 상태에서 부착하였고 두 번째, 세 번째, 네 번째 군은 각각 증류수, 인공타액. 혈액을 적용한 후 브라켓을 접착하였다 각 시편의 전단결합강도를 측정하였고 debonding 후에 브라켓과 치아 표면은 stereomicroscope을 사용하여 관찰하였다. 각 군에서 4개씩의 시편을 선택하여 표면처리된 법랑질 표면과 접착계면을 주사전자 현미경으로 관찰하여 다음과 같은 결과를 얻었다. 건조군과 증류수군의 전단결합강도는 각각 $15.22{\pm}2.86$ MPa과 $160.20{\pm}3.85MPa$로 혈액군의 전단결합강도$(12.50{\pm}2.94MPa)$보다 높았다.(P<0.05). 건조군과 증류수군, 그리고 인공타액군간에는 전단결합강도에 통계적 차이가 없었다(p>0.05). 혈액군은 다른군에 비해서 debonding 후 법랑질 표면에 잔류한 레진의 양이 더 적었다.(p<0.06). self-etching primer로 처리된 치면의 주사전자현미경 소견에서 건조군과 증류수군의 치면에서는 인공타액군과 혈액군에 비해서 더욱 뚜렷한 산부식 구조를 볼 수 있었다. 이상의 결과로서 self-etching primer/adhesive를 사용한 교정용 브라켓의 접착시 수분이나 타액의 오염은 결합력에 거의 영향을 미치지 않음을 알 수 있으며. 혈액으로 오염시에는 결합력에 영향을 미치지만. 임상적으로 유용한 최소 결합강도(5.9-7.8 MPa) 이상을 보이고 있음을 알 수 있었다.

잡초경합에 관한 연구 제1보 수도 재배양식에 따른 잡초 경합 구조 해석 (Studies on the Weed Competition 1. Interpretation of Weed Competition of Paddy Rice Under Various Cultural Patterns)

  • 구자옥;정순주;정봉현
    • 한국작물학회지
    • /
    • 제25권1호
    • /
    • pp.77-86
    • /
    • 1980
  • 성력화 요구에 따른 수도재배양식 변화에 기인되는 작물 및 잡초의 경합 구조 진전 양상을 조사한 결과 다음의 결론을 얻었다. 1. 수도의 초기생육 중 초고에 대한 잡초경합(서광 영향)은 직파에서 크고 이앙재배에서 작았다. 특히 직파산파와 직파조파에서 사초과와 화본과의 경합이 초기부터 후기까지 컸으며 기계이앙구에서는 사초과에 의하여 그리고 관행이앙구에서는 출수기 전후에 약관의 영향을 받는 경향이었다. 2. 면적(군집밀도)당의 잡초에 대한 경합은 직파에서 크고 이앙재배에서 작았는데 직파에서는 조파구가 사초과와 광엽류에 대한 경합정도가 산파구보다 컸으며 이앙재배에서는 기계이앙구가 전반생육기에 약간의 영향을 받는 반면 관행이앙구에서는 생육 중.후기부터 영향을 받는 경향이었다. 3. 수도재배양식에 따른 발생잡초종의 우점도 차이는 없었다(사초과: 일년생 방동관이, 광엽 : 물달개비. 화본과: 피.계풀). 4. 수도 지상부 생체중의 변화는 직파의 경우 logistic curve 모양을 그리고, 이앙재배에서는 linear curve 모양을 보이는데 이는 잡초발생량에 따른 면적부 균등한 Net product의 보합 때문인 것으로 판단됨. 5. 잡초경합 결과에 따른 수도 수양성 차리는 직파의 경우 $m^2$당 수수와 영화수 및 등숙률의 감소가 현저한 만딘 이앙재배에서는 등숙률과 천립중의 확보가 확실한 경향이었다. 즉, 기계이앙은 영화수 감소, 관행이앙은 소수의 감소가 문제되었다. 6. 적절한 제초로 잡초경합을 제거한 결과, 직파재배의 수양성은 크게 확보하는 경향이였다. 따라서 성력화요구에 따른 기계이앙재배는 잡초의 문제가 특별하지 않는 반면 직파재배의 경우에는 적절한 제초법 구현이 선결문제인 것으로 판단되었다.차를 보면 포화지방산에서는 숙기별 차이가 거의 없으나 불포화지방산중 Oleic acid는 조숙에서 만숙으로 갈수록 함량이 감소하는데 반해서 Linoleic acid는 만숙일수록 함량이 증가하는 경향이었다. 특히 조숙종에서는 Oleic acid 함량이 Linoleic acid 함량보다 약간 더 높아서 중ㆍ만숙종과 조성 패턴이 다름을 보여 주었다. 7 착과습성에 따른 지방산조성 차이에서는 1과성은 포화지방산이 높고 3과성은 불포화지방산중 Linoleic acid 함량이 1과성보다 월등히 높았으나 Oleic acid 함량은 1과성보다 약관 낮은 편이었다. 8. 실방수 차이에서는 3과성 2실4수이 불포화지방산이 가장 높았고 포화지방산에서는 1과성 2실4수이 가장 높았다. 4실8수에서는 일정한 영향이 보이지 않았다. 9. 지방산 간의 상관관계를 보면 불포화지방산과 포화지방산 간에는 r =-0.955**의 높은 부의 상관을 보여 지방산 개량육종의 전망을 밝게 해주며 O1eic과 Linoleic acid간에도 에우 높은 부상관을 나타내고 있어 필수지방산 함량을 높이는 개량 육종도 가능하다.이외의 처방을 요구하고 있다. 위생 및 보건장비의 구비 상환은 완전치 못하였고 소독을 전혀 실시하지 않는 양계장도 다소 있었다. 소독약의 이용량도 높은 편이 아니었다. 백신접종에 있어서 산란계의 경우 ND와 계두백신을 97.6%이용하고 있으나 육계의 경우 ND 백신은 43.6%, 계두의 경우 5.1%만 이용하고 있어 백신의 황용에 있어서 육계의 경우 아주 저조하였다. 백신 효과에 대한 신뢰도에 있어서는 85.3% 이상이 효과가 있다고 응답하였으며 백신의 선택에 있어서는 특성 제품을 요구하는 율이 26.7%나 되고 있다. 그리고 백신접종의 시술에 있어서

  • PDF

유구치 I급 와동에서 와동벽 위치와 중합광원에 따른 Microtensile Bond Strength 비교 연구 (MICROTENSILE BOND STRENGTH ACCORDING TO DIFFERENT DENTIN WALL POSITIONS AND CURING LIGHTS IN CLASS I CAVITY OF PRIMARY MOLAR)

  • 이현헌;장철호;김영재;김정욱;장기택
    • 대한소아치과학회지
    • /
    • 제34권1호
    • /
    • pp.62-72
    • /
    • 2007
  • 이번 실험에서는 중합수축 응력이 가장 크게 나타나는 유구치 I급 와동에서 와동벽의 위치와 중합광원의 변화에 의해 다르게 나타나는 응력의 차이를 microtensile bond strength (MTBS)를 이용하여 알아보는 것을 목적으로 하였다. 교합면 법랑질을 제거한 하악 제 2유구치 30개를 준비하여 I급 와동을 형성하였다. 제조사의 지시에 따라 상아질 접착제를 도포 후 3가지 중합광원: 할로겐 램프, 플라즈마, 발광다이오드를 이용하여 10개씩 광중합하였다. 복합레진을 한꺼번에 충전 후 각각의 중합기로 광중합하였다. 동일 치아에서 각각 치수벽과 축벽의 MTBS 측정용 시편을 제작하고 각 군을 중합광원과 와동벽 위치에 따라 할로겐 램프 - 축벽군, 할로겐 램프 - 치수벽군, 플라즈마 - 축벽군, 플라즈마 - 치수벽군, 발광다이오드 - 축벽군, 발광다이오드-치수벽군의 6개 군으로 분류하였다. 만능시험기에서 MTBS를 측정하고 파절편과 와동의 단면을 SEM을 이용하여 관찰하였다. 동일 중합광원에서 와동벽 간 비교는 T-test, 동일 와동벽에서 중합광원 간 비교는 One-way ANOVA와 Tukey's post hoc test를 이용하였고 Weibull 분포분석을 하였다. 동일 중합광원 군간 비교에서 모두 치수벽 시편의 접착강도가 축벽 시편에 비해 유의하게 높았으며 동일 와동벽 군간 비교에서 모두 중합광원에 따른 접착강도가 유의한 차이를 보이지 않았다. 축벽 시편이 치수벽 시편보다 낮은 Weibull 변수(m)를 나타내었고 SEM 관찰 결과 축벽 시편에서 보다 더 불균일한 접착이 이루어진 것을 알 수 있었다.

  • PDF

PET/CT 검사에서 매개변수 입력오류에 따른 표준섭취계수 평가 (The Evaluation of SUV Variations According to the Errors of Entering Parameters in the PET-CT Examinations)

  • 김지아;홍건철;이혁;최성욱
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.43-48
    • /
    • 2014
  • PET/CT검사에서 표준섭취계수(standardized uptake value, SUV)는 병소의 악성 여부를 판별하는 지표로서 인체내 각 장기의 생리적인 변화에 대한 정량분석을 가능하게 한다. 따라서 그 결과에 영향을 줄 수 있는 매개변수를 올바르게 입력하는 것이 매우 중요하다. 본 연구에서는 그 매개변수 중 방사능량, 체중, 방사성 동위원소 섭취시간의 입력오류에 따른 결과의 차이를 측정하여 수용 가능한 결과의 오차범위를 평가하고자 한다. 1994 NEMA 모형 내부에 열소, 테프론, 그리고 공기 3개의 삽입물을 위치시켰다. 총 27.3 MBq의 $^{18}F$를 열소와 배후 방사능 비율이 4:1로 되도록 채우고 GE Discovery STE 16(GE Healthcare, Milwaukee, USA)로 촬영하였다. 촬영 후 입력된 방사능량, 체중, 섭취 시간의 값을 기준 값에서 ${\pm}5%$, 10%, 15%, 30%, 50% 만큼 오차를 발생시킨 후 영상을 다시 재구성하였다. 재구성된 영상에서 각 삽입물 부위에 한 개, 배후방사능 부위에 총 네 개의 관심영역을 그린 후 $SUV_{mean}$과 백분율오차를 측정하여 비교 평가하였다. 기준 영상의 열소, 테프론 그리고 공기와 배후방사능에서의 $SUV_{mean}$은 각각 4.5, 0.02, 0.1 그리고 1.0이였다. 방사능량 오차 변화에 따른 $SUV_{mean}$의 최대값과 최소값은 열소에서 9.0, 3.0, 테프론에서 0.04, 0.01, 공기에서 0.3, 0.1, 배후 방사능에서 2.0, 0.6로 변화된 값을 보였다. 이 때 백분율오차는 모두 동일하게 최대 100%에서 최소 -33%로 나타났다. 체중 오차 변화의 경우 열소에서 2.2, 6.7, 테프론에서 0.01, 0.03, 공기에서 0.09. 0.28, 배후방사능에서 0.5, 1.5로 변화된 값을 보였다. 이 때 백분율오차는 테프론의 최소 -50%, 최대 52%를 제외하고 모두 최소 -50%에서 최대 50% 로 동일하게 나타났다. 섭취시간 오차의 경우 열소에서 3.8, 5.3, 테프론에서 0.01, 0.02, 공기에서 0.1, 0.2, 배후방사능에서 0.8에서 1.2로 변화된 값을 보였다. 백분율오차는 열소와 배후방사능은 최소 -14%에서 최대 17%로 동일하게 나타났으며 테프론의 경우 최소 -11%에서 최대 21%, 공기의 경우 최소 -12%에서 최대 20%로 나타났다. 일반적으로 수용 가능한 오차의 범위를 5%로 설정할 경우, 본 실험 결과에서 방사능량과 체중의 오차가 ${\pm}5%$ 이내 일 때 $SUV_{mean}$의 오차가 5% 범위에 포함되었다. 이러한 결과들을 고려해 볼 때 검사장비에 입력되는 방사능량과 체중에 직접적인 영향을 줄 수 있는 선량검량계와 체중계의 검교정은 오차범위 5% 이내로 이루어져야 한다. 섭취 시간의 경우 삽입물의 종류에 따라 서로 다른 오차 범위를 보였으며 열소와 배후방사능에서 오차가 ${\pm}15%$ 이내일 때 $SUV_{mean}$에 5% 내의 오차가 발생하였다. 따라서 검사 시 촬영용 스캐너를 포함하여 두 개 이상의 시계를 사용할 경우 각각의 시간 오차들도 함께 고려되어야 할 것이다.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

호흡주기에 따른 방사선입체조형치료법의 개발 (Development of Conformal Radiotherapy with Respiratory Gate Device)

  • 추성실;조광환;이창걸;서창옥
    • Radiation Oncology Journal
    • /
    • 제20권1호
    • /
    • pp.41-52
    • /
    • 2002
  • 목적 : 호흡주기에 따른 위치변동 감지센서를 이용하여 종양의 위치가 일정워치에 있을 때만 방사선을 치료하는 호흡 동기치료기구를 제작하고 일정한 호흡주기 상태에서 수행된 CT simulation과 3차원 입체조형치료계획에 따라 방사선을 치료하는 시스템을 개발하고자 하였다. 호흡유무에 따른 종양의 치료 마진(margin)을 측정하고 계획용표적체적(planning target volume:PTV)의 크기에 따른 선량체적표(dose volume histogram:DVH)와 종양억제확률(tumor control probability:NTCP), 건강조직손상확률(normal tissue complication probability:NTCP) 및 선량 통계자료를 통하여 치료성과를 평가하고 선량증강 범위를 예측하고자 하였다. 대상 및 방법 : 종양이 비교적 작고 전이가 없는(T1N0M0) 5명의 폐암환자를 선택하여 X-선 조준장치를 이용하여 횡격막의 이동거리를 측정하는 방법으로 내부장기의 운동을 평가하였다. 호흡동기치료기구는 끌어당김 센서가 부착된 허리띠 모양으로 구성되었으며 이를 흉곽 또는 복부에 부착하여 호흡주기에 의한 흉곽의 크기변동에 따라 센서의 회로가 개폐되고 이것을 선형가속기의 조종간에 연결하는 간단한 기구로서 감도와 재현성이 높았다. 호흡을 배기한 후 일시적 호흡이 정지된 상태에서 Spiral-CT (PQ-5000)로 3차원 영상을 획득하고 Virtual CT-simulator (AcQ-SIM)에 의하여 종양의 위치와 주위 장기들을 확인 도시하였으며 3차원 치료계획장치(Pinnacle, ADAC Co.)를 이용하여 3차원 입체조형치료를 계획하였다. 치료계획의 평가는 호흡동기치료기구의 사용유무에 따른 PTV의 크기에 따라 최적 선량분포를 구사하였으며 각각의 DVH, TCP, NTCP 및 선량통계자료를 도출 비교 검토하였다. 결과 : X-선 simulation에서 폐암환자의 횡격막 이동은 약 1 cm에서 2.5 cm로서 평균 1.5 cm로 측정되었고 자유호흡시 PTV는 CTV (clinical target volume)에 약 2 cm 마진을 주었으며 호흡동기치료기구를 사용하였을 때는 0.5 cm 마진이 적당한 것으로 측정되었다. 종양의 PTV는 연장 마진의 거의 자승비로 증가하였으며 TCP의 값은 마진 범위 $(0.5\~2.0\;cm)$에 관계없이 거의 일정하였고 NTCP의 값은 마진 크기에 따라 평균 $65\%$로 급속히 증가하였다. 결론 : 호흡주기에 따른 위치변동 감지센서를 이용한 호흡동기치료기구는 종양의 위치가 일정할 때만 방사선이 조사되는 간단하고 정확한 장치로서 3차원 입체조형치료 및 강도변조방사선치료에서 매우 유용한 장치임을 확인할 수 있었다. 또한 호흡조절 방사선입체조형치료방법의 기술과 시술절차를 확립시키고 정량적인 선량평가를 위하여 DVH, TCP, NTCP 등의 정량분석과 종양의 투여 선량 증가량(dose escalation)을 예측하는 기초자료를 제공할 수 있었다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF