• 제목/요약/키워드: M2 polarization

검색결과 643건 처리시간 0.04초

Acid Treatments of Carbon Nanotubes and Their Application as Pt-Ru/CNT Anode Catalysts for Proton Exchange Membrane Fuel Cell

  • Kim, Min-Sik;Lim, Sin-Muk;Song, Min-Young;Cho, Hyun-Jin;Choi, Yun-Ho;Yu, Jong-Sung
    • Carbon letters
    • /
    • 제11권4호
    • /
    • pp.336-342
    • /
    • 2010
  • Different oxidation treatments on CNTs using diluted 4.0 M $H_2SO_4$ solution at room temperature and or at $90^{\circ}C$ reflux conditions were investigated to elucidate the physical and chemical changes occurring on the treated CNTs, which might have significant effects on their performance as catalyst supports in PEM fuel cells. Raman spectroscopy, X-ray diffraction and transmission electron microscope analyses were made for the acid treated CNTs to determine the particle size and distribution of the CNT-supported Pt-Ru nanoparticles. These CNT-supported Pt-based nanoparticles were then employed as anode catalysts in PEMFC to investigate their catalytic activity and single-cell performance towards $H_2$ oxidation. Based on PEMFC performance results, refluxed Pt-Ru/CNT catalysts prepared using CNTs treated at $90^{\circ}C$ for 0.5 h as anode have shown better catalytic activity and PEMFC polarization performance than those of the commercially available Pt-Ru/C catalyst from ETEK and other Pt-Ru/CNT catalysts developed using raw CNT, thus demonstrating the importance of acid treatment in improving and optimizing the surface properties of catalyst support.

TiN 이온 플레이팅한 강판의 내식성에 관한 연구(III)-Ni 및 Ti 하지코팅두께의 영향- (Corrosion Behavior of TiN Ion Plated Steel Plate(III)-Effects of Ni and Ti interlayer thickness-)

  • 한전건;연윤모
    • 한국표면공학회지
    • /
    • 제26권2호
    • /
    • pp.55-62
    • /
    • 1993
  • The effect of interlayer coating thickness of Ni and Ti on corrosion behavior was studied for TiN ion plat-ed steel plate. Interlayer coating was carried out in a single and bi-layer to a various thickness combination prior to final TiN coating. Corrosion behavior was evaluated by anodic polarization test in 1N H2SO4 as well as salt spray test. Ni interlayer coating was effectived in reducing corrosion current density of active region and Ti interlayer coating over Ni coating reduced the anodic corrosion current density by an order of 4 with increasing the thickness of Ti up to$ 3\mu\textrm{m}$. The improvement of corrosion resistance by Ni/Ti interlayer coating was attributed to the effective prevention of penetration of active corrosion agent resulting from the inherent corrosion resistance of Ni and Ti. Putting corrosion behavior was observed from salt spray test result for all specimens and corrosion resistance at salt atmosphere was enhanced with increasing Ni and Ti thickness, Cor-lay TiN coating was spalled out by the generation of corrosion products.

  • PDF

LiNbO$_3$를 이용한 MFSFET의 제작 및 특성 (Fabrication and Properties of MFSFET′s using LiNbO$_3$ film)

  • 정순원;김채규;이상우;김광호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.63-66
    • /
    • 1998
  • Prototype MFSFET′s using ferroelectric oxide LiNbO$_3$ as a gate insulator have been successfully fabricated with the help of 2 sheets of metal masks and demonstrated nonvolatile memory operations of the MFSFET′s. The estimated field-effect electron mobility and transconductance on a linear region of the fabricated FET were 600 $\textrm{cm}^2$/V.s and 0.16 mS/mm, respectively. The drain current of the "on" state was more than 4 orders of magnitude larger than the "off" state current at the same "read" gate voltage of 0.5 V, which means the memory operation of the MFSFET. A write voltage as low as $\pm$3 V, which is applicable to low power integrate circuits, was used for polarization reversal.

  • PDF

Dielectric Properties of PZT(20/80)/PZT(80/20) Heterolayered Thick Films Fabricated by Screen-printing Method

  • Lee, Sung-Gap;Lee, Young-Hie
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권3호
    • /
    • pp.129-133
    • /
    • 2006
  • Ferroelectric PZT heterolayered thick films were fabricated by the alkoxide-based sol-gel method. PZT(20/80) and PZT(80/20) paste were made and alternately screen-printed on the alumina substrates. The coating and drying procedure was repeated 4 times to form the heterolayered thick films. The thickness of the PZT heterolayered thick films was approximately $60{\mu}m$. All PZT thick films showed the typical XRD patterns of a polycrystalline rhombohedral structure. And in the PZT thick films sintered at $1100^{\circ}C$, the pyrochlore phase was observed due to the evaporation of PbO. The relative dielectric constant and the dielectric loss of the PZT thick films sintered at $1050^{\circ}C$ were 445.2 and 1.90 % at 1 kHz, respectively. The remanent polarization and coercive field of the PZT thick films sintered at $1050^{\circ}C$ were $14.15{\mu}C/cm^2$ and 19.13 kV/cm, respectively.

OH MASERS TOWARDS THE W49A STAR-FORMING REGION WITH MERLIN AND e-MERLN OBSERVATIONS

  • ASANOK, KITIYANEE;ETOKA, SANDRA;GRAY, MALCOLM D.;RICHARDS, ANITA M.S.;KRAMER, BUSABA H.;GASIPRONG, NIPON
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.125-127
    • /
    • 2015
  • We present preliminary results from OH ground state phase referenced observations carried out with the Multi Element Radio Linked Interferometer Network (MERLIN) and e-MERLIN towards the massive star forming region W49A. There are three active SFRs within this complex: W49 North (W49 N), W49 South (W49 S) and W49 South West (W49 SW). The first epoch of observations was obtained in 2005 with MERLIN while the second epoch was obtained in 2013 with the e-MERLIN upgraded system. In this paper, we present 1665 and 1720 MHz maser emission towards W49 S and W49 SW. Overall, both epochs show good agreement with the previous observations of Argon et al. (2000) carried out with the Very Large Array (VLA). The better sensitivity and wider velocity coverage of the MERLIN/e-MERLIN observations allowed us to discover a new 1720 MHz OH maser site in W49 S.

염화물의 농도가 전기아연도금에 미치는 영향 (Effects of Chloride Concentration on Zinc Electroplating)

  • 김재민;이정훈;김용환;김영하;홍문희;정훤우;정원섭
    • 한국표면공학회지
    • /
    • 제43권2호
    • /
    • pp.51-56
    • /
    • 2010
  • The zinc electroplating with respect to the chloride concentration was investigated by X-ray diffraction(XRD), scanning electron microscope (SEM), and cathodic polarization measurement. The cathodic overpotential during electroplating was first decreased and then increased with increase of chloride concentration in electrolyte. The decreased cathodic overpotential leads to preferred orientation of (002) plane, high current efficiency and satisfactory zinc deposits. The increased cathodic overpotential causes random orientation, low current efficiency and edge burning. The cathodic overpotential was affected by chloride concentration in electrolyte, not by the kind of chloride, such as NaCl and KCl. An optimized chloride concentration was 3 M for zinc electroplating. Also, it is considered that NaCl can be a alternation for KCl as a main salt of zinc electroplating bath.

양극산화 처리된 5083 알루미늄 합금의 해수 내 유속변화에 따른 전기화학적 손상 특성 (Electrochemical Damage Characteristics of Anodized 5083 Aluminum Alloy with Flow Rate in Seawater)

  • 박일초;김성종
    • 한국표면공학회지
    • /
    • 제49권4호
    • /
    • pp.349-356
    • /
    • 2016
  • In this study, electrochemical damage behaviors with flow rate were investigated for anodized 5083 aluminum alloy in seawater. As the results of anodic polarization experiments and potentiostatic experiments at +1.0 V (vs. SSCE), the non-flow condition presented largely damaged surface resulting from a tendency of local pitting damage. Under various flow rate conditions, however, less surface damages under the application of anodic potential was obtained which is attributed to no accumulation of $H^+$ and $Cl^-$ ions on the surface. On the other hand, the results of the potentiostatic experiments at -1.0 V (vs. SSCE) with flow rate showed that anodized 5083 aluminum alloys could achieve the effective cathodic protection by low cathodic protection current density less than $2.61{\times}10^{-7}A/cm^2$ even under high flow rate of 1 m/s.

주조 방식 및 압연에 따른 연축전지용 납 합금 기판의 부식 특성 (Effects of Casting Method and Rolling on the Corrosion Behaviors of Pb Alloys for a Lead Acid Battery)

  • 오꽃님;이규혁;장희진
    • Corrosion Science and Technology
    • /
    • 제20권5호
    • /
    • pp.315-323
    • /
    • 2021
  • In this study, we examined corrosion behaviors of two types of Pb alloys for a lead acid battery comparatively. One containing 6.6 wt% Sn, 36 mg/kg Bi, and 612.4 mg/kg Ca was prepared by twin-roll continuous casting. The other containing 5.2 wt% Sn, 30.5 mg/kg Ag, and 557 mg/kg Ca was made by twin-belt continuous casting. Potentiodynamic polarization tests were performed to evaluate corrosion resistance. Cyclic voltammetry was done to examine oxidation and reduction reactions occurring on the surface of each alloy in 4.8 M H2SO4 solution. Electrochemical test results implied that the Pb alloy prepared with the twin-belt casting method was less stable than that cast with the twin-roll method. Such results might be due to precipitations formed during the casting process. Rolling did not appear to affect the corrosion behavior of the twin-roll samples with Ag < 10 mg/kg, while it reduced the anodic reaction of Ag on the surface of the twin-belt sample with 30.5 mg/kg Ag.

플라즈마 산질화처리된 AISI 420 마르텐사이트 스테인레스 강재의 표면 경도 및 부식 거동 (Surface Hardness and Corrosion Behavior of AISI 420 Martensitic Stainless Steels Treated by Plasma Oxy-Nitriding Processing)

  • 김진한;이광민
    • 한국재료학회지
    • /
    • 제33권7호
    • /
    • pp.309-314
    • /
    • 2023
  • This study aimed to address the limitations of traditional plasma nitriding methods by implementing a short-term plasma oxy-nitriding treatment on the surface of AISI 420 martensitic stainless steel. This treatment involved the sequential formation of nitride and oxide layers, to enhance surface hardness and corrosion resistance, respectively. The process resulted in the formation of a 20 ㎛-thick nitride layer and a 3 ㎛-thick oxide layer on the steel surface. Initially, the hardness increased by 2.2 times after nitriding, followed by a subsequent decrease of approximately 31 % after oxidation. While the nitriding process reduced corrosion resistance, the subsequent oxidation process led to the formation of a passive oxide film, effectively resolving this issue. The pitting corrosion of the oxide passive film started at 82.6 mVssc, providing better corrosion resistance characteristics than the nitride layer. Consequently, the trade-off between surface hardness and corrosion resistance in plasma oxy-nitrided AISI 420 martensitic stainless steel is anticipated to be recognized as an innovative and comprehensive surface treatment process for biomedical components.

리튬이온 이차전지용 고로딩 LiCoO2 양극의 전극설계에 따른 전기화학적 성능연구 (Effect of Electrode Design on Electrochemical Performance of Highly Loaded LiCoO2 Positive Electrode in Lithium-ion Batteries)

  • 김해빈;류지헌
    • 전기화학회지
    • /
    • 제23권2호
    • /
    • pp.47-55
    • /
    • 2020
  • 고에너지 밀도의 리튬이온 이차전지를 구성하기 위하여 고로딩 LiCoO2 양극을 구성하였으며, 이의 전극설계를 다르게 하며 전기화학적 특성을 비교하였다. 기준로딩을 적용한 전극의 경우 약 2.2 mAh/㎠의 로딩값을 가지도록 하고, 고로딩 전극의 경우 약 4.4 mAh/㎠의 로딩값을 가지도록 전극을 제조하였다. 이때 도전재인 카본블랙의 함량과 전극의 기공도를 다르게 구성하여 전극 내의 전자전도도와 이온전도도가 고로딩 전극의 성능에 주는 영향을 비교하였다. 도전재의 함량이 증가할수록 전기화학적 성능이 향상될 것으로 기대하였으나, 도전재의 함량이 7.5 질량%까지 증가하게 되면 오히려 성능의 저하가 발생하였다. 이는 도전재가 충분히 제공된 경우에는, 동일한 로딩의 전극구성에서 활물질인 LiCoO2 구성비의 감소로 인해 전극두께가 증가하기 때문에 이로 인한 분극증가가 원인으로 판단된다. 그리고 전극의 기공도를 증가시키게 되면 이온전달의 경로는 확장될 수 있으나, 입자들 간의 접촉이 저하되고 전극의 두께가 증가하기 때문에 전극 내 전자전달은 불리하게 된다. 따라서, 전극의 압착을 강하게 하여 기공도를 낮출수록 전자전달이 개선되어 전지의 성능이 향상되었다. 고로딩 전극의 제조에 있어서는 전자전달의 경로를 충분히 확보하면서 전극두께를 감소시키는 전극설계가 필요하다.